Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “polyimides”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Flexible Quasi-Two-Dimensional CoFe 2 O 4 Epitaxial Thin Films for Continuous Strain Tuning of Magnetic Properties

Epitaxial thin films of CoFe 2 O 4 (CFO) have successfully been transferred from a SrTiO 3 substrate onto a flexible polyimide substrate. By bending the flexible polyimide, different levels of uniaxial strain are continuously introduced into the CFO epitaxial thin films. Unlike traditional epitaxial strain induced by substrates, the strain from bending will not suffer from critical thickness limitation, crystalline quality variation, and substrate clamping, and more importantly, it provides a more intrinsic and reliable way to study strain-controlled behaviors in functional oxide systems. It is found that both the saturation magnetization and coercivity of the transferred films can be changed over the bending status and show a high accord with the movement of the curvature bending radius of the polyimide substrate. Lastly, this reveals that the mechanical strain plays a critical role in tuning the magnetic properties of CFO thin films parallel and perpendicular to the film plane direction.

36 MATERIALS SCIENCE↗

Femtosecond laser driven high-flux highly collimated MeV-proton beam

Highlly collimated energetic protons whose energies are up to 4 MeV are generated by an intense femtosecond Titanium Sappheire laser pulse interacting with a 7.5, 12.5, and 25 {mu}m-thick Polyimide tape target and 5 {mu}m-thick copper target. We find no clear difference on the proton spectra from 7.5, 12.5, and 25 {mu}m Polyimide tape target. The highest conversion efficiency from laser energy into protons of {approx}3% is observed with a 7.5 {mu}m thick Polyimide target. The quality of the proton beam is good enough to obtain a clear projection image of a mesh having 10 {mu}m line and space structure, installed into the passage of the beam. We obtain clear vertical lines on the proton intensity profiles from the copper target, which are considered to be transferred from the surface of the copper target. From it, we can restrict the size of the proton emitting region to be {approx}20 {mu}m.

43 PARTICLE ACCELERATORS↗

VERY LOW FREQUENCY BREAKDOWN PROPERTIES OF ELECTRICAL INSULATION MATERIALS AT CRYOGENIC TEMPERATURES

For long cables or equipment with large capacitance it is not always possible to conduct high voltage withstand at tests at 60 Hz due to limitations in charging currents of the power supply. Very low frequency (typically at a frequency of 0.1 Hz) has been used for conventional cables as a way of getting around the charging current limitation. For superconducting grid applications the same issues apply. However there is very little data at cryogenic temperatures on how materials perform at low frequency compared to 60 Hz and whether higher voltages should be applied when performing a high voltage acceptability test. Various materials including G10 (fiberglass reinforced plastic or FRP), Cryoflex™ (a tape insulation used in some high temperature superconducting cables), kapton (commonly used polyimide), polycarbonate, and polyetherimide, and in liquid nitrogen alone have been tested using a step method for frequencies of 60 Hz, 0.1 Hz, and dc. The dwell time at each step was chosen so that the aging factor would be the same in both the 60 Hz and 0.1 Hz tests. The data indicated that, while there is a small frequency dependence for liquid nitrogen, there are significant differences for the solid materials studied. Breakdown data for these materials and for model cables will be shown and discussed.

cryogenic dielectric↗

A high-transparency, micro-patternable chip for X-ray diffraction analysis of microcrystals under native growth conditions

A highly X-ray-transparent, silicon nitride-based device has been designed and fabricated to harvest protein microcrystals for high-resolution X-ray diffraction data collection using microfocus beamlines and XFELs. Microcrystals present a significant impediment to the determination of macromolecular structures by X-ray diffraction methods. Although microfocus synchrotron beamlines and X-ray free-electron lasers (XFELs) can enable the collection of interpretable diffraction data from microcrystals, there is a need for efficient methods of harvesting small volumes (<2 µl) of microcrystals grown under common laboratory formats and delivering them to an X-ray beam source under native growth conditions. One approach that shows promise in overcoming the challenges intrinsic to microcrystal analysis is to pair so-called ‘fixed-target’ sample-delivery devices with microbeam-based X-ray diffraction methods. However, to record weak diffraction patterns it is necessary to fabricate devices from X-ray-transparent materials that minimize background scattering. Presented here is the design of a new micro-diffraction device consisting of three layers fabricated from silicon nitride, photoresist and polyimide film. The chip features low X-ray scattering and X-ray absorption properties, and uses a customizable blend of hydrophobic and hydrophilic surface patterns to help localize microcrystals to defined regions. Microcrystals in their native growth conditions can be loaded into the chips with a standard pipette, allowing data collection at room temperature. Diffraction data collected from hen egg-white lysozyme microcrystals (10–15 µm) loaded into the chips yielded a complete, high-resolution (<1.6 Å) data set sufficient to determine a high-quality structure by molecular replacement. The features of the chip allow the rapid and user-friendly analysis of microcrystals grown under virtually any laboratory format at microfocus synchrotron beamlines and XFELs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Multimaterial Aerosol Jet Printed Magnetic Nanocomposites for Microwave Circuits

Here this article demonstrates the process and characterization of additively manufactured polymer-matrix magnetic nanocomposites. These nanocomposites are composed of nickel-zinc ferrite (Ni 0.5 Zn 0.5 Fe 2 O 4 ) nanoparticles in a polyimide matrix. These materials are printed using multimaterial aerosol jet printing where aerosols of nickel-zinc ferrite and polyimide inks are mixed in place to fabricate structures with nonunity relative permeability. To characterize these materials, we use energy-dispersive X-ray spectroscopy to estimate the content of ferrite in the composite, fitted simulation models, and ring resonator measurements to estimate the permeability. In fully aerosol jet printed 1-mm 2 inductors, we demonstrate an increase in inductance density of 40% in a 4.5-turn microstrip spiral inductor using this printed composite. These fully printed inductors demonstrate an inductance density of 4.2-nH/mm 2 . EDS analysis shows films with 18 wt.% Ni 0.5 Zn 0.5 Fe 2 O 4 . Finally, we show microstrip transmission lines on printed composite compared to the same on polyimide subjected to a dc magnetic bias, displaying a magnetic resonance behavior.

42 ENGINEERING↗

Insulation Resistance of Flat Flexible Circuit Boards

The insulation resistance (R I ) between parallel copper traces embedded on flexible, polyimide-based circuit boards was measured as a function of temperature, substrate type, copper thickness, and feature size. The results show a strong dependency on temperature: the measured R I decreases nearly seven-orders of magnitude upon a 90degC change. Also measured was R I as a function of the trace and space of parallel copper circuits. This dependency is less obvious but a correlation showing narrower spacing leads to lower R I is evident. The thickness/width of the copper traces has less of an effect on the measured R I . The thickness of the polyimide-based substrate, or core of the circuit boards, was also varied. Measurements of the R I versus substrate thickness were inconclusive. The height of the copper traces was changed and shows that heavier (or taller traces) result in a lower measured R I . Lastly, it was shown that the adhesive found between the copper traces and the polyimide core on so-called "LF" Pyralux (R) boards significantly reduces the measured R I compared to "AP" Pyralux (R) boards of the same dimensions. The presences of this adhesive in all LF materials, including LF coverlays should be avoided if high R I is desired for narrowly spaced copper traces. Alternative materials like AP Pyralux (R) or HT Pyralux (R) available from DuPont TM should be investigated when designing copper-based flat-flex circuit boards that require a demanding environmental specifications.

42 ENGINEERING↗

CO2 Separation Using Thermally Optimized Membranes: A Comprehensive Project Report (2000 - 2007)

This is a complete (Fiscal Years 2000–2006) collection of the Idaho National Laboratory’s (INL) research and development contributions to the project, “CO2 Separation Using Thermally Optimized Membranes.” The INL scientific contribution to the project has varied due to the fluctuations in funding from year to year. The focus of the project was polybenzimidazole (PBI) membranes and developing PBI compounds (both substitution and blends) that provide good film formation and gas separation membranes. The underlying problem with PBI is its poor solubility in common solvents. Typically, PBI is dissolved in “aggressive” solvents, like N,N-dimethylacetamide (DMAc) and N methylpyrrolidone (NMP). The INL FY-03 research was directed toward making soluble N-substituted PBI polymers, where INL was very successful. Many different types of modified PBI polymers were synthesized; however, film formation proved to be a big problem with both unsubstituted and N-substituted PBIs. Therefore, INL researchers directed their attention to using plasticizers or additives to make the membranes more stable and workable. During the course of these studies, other high-performance polymers (like polyamides and polyimides) were found to be better materials, which could be used either by themselves or blends with PBI. These alternative high-performance polymers provided the best pathway forward for soluble high-temperature polymers with good stable film formation properties. At present, the VTEC polyimides (product of RBI, Inc.) are the best film formers that exhibit high-temperature resistance. INL’s gas testing results show VTEC polyimides have very good gas selectivities for both H2/CO2 and CO2/CH4. Overall, these high-performance polymers pointed towards new research areas where INL has gained a greater understanding of polymer film formation and gas separation. These studies are making possible a direct approach to stable polymer-based high-temperature gas separation membranes. This report is separated into several sections due to the complexity of the research and the variation with the development of better high-temperature, gas separation membranes. Several fiscal years are combined because the research and development efforts within those areas crossed fiscal year boundaries.

36 MATERIALS SCIENCE↗

CO2 Separation Using Thermally Optimized Membranes: A Comprehensive Project Report (2000 - 2007)

This is a complete (Fiscal Years 2000–2006) collection of the Idaho National Laboratory’s (INL) research and development contributions to the project, “CO2 Separation Using Thermally Optimized Membranes.” The INL scientific contribution to the project has varied due to the fluctuations in funding from year to year. The focus of the project was polybenzimidazole (PBI) membranes and developing PBI compounds (both substitution and blends) that provide good film formation and gas separation membranes. The underlying problem with PBI is its poor solubility in common solvents. Typically, PBI is dissolved in “aggressive” solvents, like N,N-dimethylacetamide (DMAc) and N methylpyrrolidone (NMP). The INL FY-03 research was directed toward making soluble N-substituted PBI polymers, where INL was very successful. Many different types of modified PBI polymers were synthesized; however, film formation proved to be a big problem with both unsubstituted and N-substituted PBIs. Therefore, INL researchers directed their attention to using plasticizers or additives to make the membranes more stable and workable. During the course of these studies, other high-performance polymers (like polyamides and polyimides) were found to be better materials, which could be used either by themselves or blends with PBI. These alternative high-performance polymers provided the best pathway forward for soluble high-temperature polymers with good stable film formation properties. At present, the VTEC polyimides (product of RBI, Inc.) are the best film formers that exhibit high-temperature resistance. INL’s gas testing results show VTEC polyimides have very good gas selectivities for both H2/CO2 and CO2/CH4. Overall, these high-performance polymers pointed towards new research areas where INL has gained a greater understanding of polymer film formation and gas separation. These studies are making possible a direct approach to stable polymer-based high-temperature gas separation membranes. This report is separated into several sections due to the complexity of the research and the variation with the development of better high-temperature, gas separation membranes. Several fiscal years are combined because the research and development efforts within those areas crossed fiscal year boundaries.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Flexible Copper Metal Circuits via Desktop Laser Printed Masks

A novel process is demonstrated that produces patterns of electrically conductive copper on a flexible polyimide film substrate using standard desktop laser printed toner and near room temperature aqueous chemistry. The laser toner acts as a mask to selectively block the ion exchange self-metallization (IESM) reduction reaction that forms nanoscale silver or palladium coatings at the polyimide surface. The silver or palladium IESM coating is then used as a catalyst for electroless deposition of copper. Under appropriate conditions, the copper is deposited selectively on top of the catalyst layer. The resulting copper layer has a measured sheet resistance as low as 0.3 Ohms/sq. Electrical isolation was measured between copper traces spaced as close as 300 microns, and high conductivity was measured along traces with widths as low as 200 microns. The minimum pattern size appears to be limited primarily by the resolution of the laser toner pattern, as the IESM metal layer was observed to follow the contours of individual toner particles. Here, the process avoids the use of high temperature, vacuum, and organic solvents and is thus suitable for very low cost prototyping or distributed manufacturing of simple electronic devices.

36 MATERIALS SCIENCE↗

Competitive adsorption within electrode slurries and impact on cell fabrication and performance

We ask why do battery researchers use 10-20 wt% binder in research cells when commercial chemistries use much less? This report seeks to explore this question by understanding the ordering and structure of polyimide binder with a silicon/pitch-carbon black electrode system. Correlating the effect of binder concentration on electrode architecture and electrochemical properties is vital to enhancing silicon anode cycle and calendar life. Using ultra-small angle neutron scattering (USANS) and binder adsorption isotherms an optimal region of polyimide (PI) binder coverage was found. Further, there is a preferential adsorption of PI to carbon black that has to be completed before PI binds to the silicon. Optimizing the concentration of binder leads to a 50% increase in capacity due to the optimization of binder-silicon-carbon interactions.

25 ENERGY STORAGE↗

Ultra-Long-Term Reliable Encapsulation Using an Atomic Layer Deposited HfO 2 /Al 2 O 3 /HfO 2 Triple-Interlayer for Biomedical Implants

Long-term packaging of miniaturized, flexible implantable medical devices is essential for the next generation of medical devices. Polymer materials that are biocompatible and flexible have attracted extensive interest for the packaging of implantable medical devices, however realizing these devices with long-term hermeticity up to several years remains a great challenge. Here, polyimide (PI) based hermetic encapsulation was greatly improved by atomic layer deposition (ALD) of a nanoscale-thin, biocompatible sandwich stack of HfO 2 /Al 2 O 3 /HfO 2 (ALD-3) between two polyimide layers. A thin copper film covered with a PI/ALD-3/PI barrier maintained excellent electrochemical performance over 1028 days (2.8 years) during acceleration tests at 60 &deg;C in phosphate buffered saline solution (PBS). This stability is equivalent to approximately 14 years at 37 &deg;C. The coatings were monitored in situ through electrochemical impedance spectroscopy (EIS), were inspected by microscope, and were further analyzed using equivalent circuit modeling. The failure mode of ALD Al 2 O 3 , ALD-3, and PI soaking in PBS is discussed. Encapsulation using ultrathin ALD-3 combined with PI for the packaging of implantable medical devices is robust at the acceleration temperature condition for more than 2.8 years, showing that it has great potential as reliable packaging for long-term implantable devices.

60 APPLIED LIFE SCIENCES↗

A Universal Organic Cathode for Ultrafast Lithium and Multivalent Metal Batteries

Abstract Low‐cost multivalent battery chemistries (Mg 2+ , Al 3+ ) have been extensively investigated for large‐scale energy storage applications. However, their commercialization is plagued by the poor power density and cycle life of cathodes. A universal polyimides@CNT (PI@CNT) cathode is now presented that can reversibly store various cations with different valences (Li + , Mg 2+ , Al 3+ ) at an extremely fast rate. The ion‐coordination charge storage mechanism of PI@CNT is systemically investigated. Full cells using PI@CNT cathodes and corresponding metal anodes exhibit long cycle life (>10000 cycles), fast kinetics (>20 C), and wide operating temperature range (−40 to 50 °C), making the low‐cost industrial polyimides universal cathodes for different multivalent metal batteries. The stable ion‐coordinated mechanism opens a new foundation for the development of high‐energy and high‐power multivalent batteries.

Fan, Xiulin↗

Synergistic Tuning of Microstructure and Morphology in Carbon Molecular Sieve Hollow Fibers for Propylene/Propane Separation

Abstract Asymmetric carbon molecular sieve (CMS) hollow fiber membranes with tunable micro‐ and macro‐structural morphologies for energy efficient propylene‐propane separation are reported here. A sub‐glass transition temperature (sub‐Tg) thermal oxidative crosslinking strategy enables simultaneous optimization of the intrinsic molecular sieving properties while also reducing the thickness of the CMS “skin” derived from the 6FDA : BPDA/DAM polyimide precursors. Such synergistic tuning of CMS microstructure and macroscopic morphology of CMS hollow fibers enables significantly increased propylene permeance (reaching 186.5 GPU) while maintaining an appealing propylene/propane selectivity of 13.3 for 50/50 propylene/propane mixed gas feeds. Our findings reveal a more refined and versatile tool than available with previous O 2 ‐doping pretreatments. The advanced approach here should be broadly useful to other polyimide precursors and diverse gas pairs.

Liu, Zhongyun [School of Chemical &amp, Biomolecul↗

Synergistic Tuning of Microstructure and Morphology in Carbon Molecular Sieve Hollow Fibers for Propylene/Propane Separation

Abstract Asymmetric carbon molecular sieve (CMS) hollow fiber membranes with tunable micro‐ and macro‐structural morphologies for energy efficient propylene‐propane separation are reported here. A sub‐glass transition temperature (sub‐Tg) thermal oxidative crosslinking strategy enables simultaneous optimization of the intrinsic molecular sieving properties while also reducing the thickness of the CMS “skin” derived from the 6FDA : BPDA/DAM polyimide precursors. Such synergistic tuning of CMS microstructure and macroscopic morphology of CMS hollow fibers enables significantly increased propylene permeance (reaching 186.5 GPU) while maintaining an appealing propylene/propane selectivity of 13.3 for 50/50 propylene/propane mixed gas feeds. Our findings reveal a more refined and versatile tool than available with previous O 2 ‐doping pretreatments. The advanced approach here should be broadly useful to other polyimide precursors and diverse gas pairs.

Liu, Zhongyun↗

Surface modification of ZIF ‐90 with triptycene for enhanced interfacial interaction in mixed‐matrix membranes for gas separation

Abstract Zeolite imidazole framework (ZIF‐90) nanoparticles were chemically modified by grafting triptycene moieties. The modified nanoparticles were introduced into a triptycene‐based polyimide as fillers to generate mixed matrix membranes (MMMs) for gas separation. The incorporation of “hook‐like” triptycene moieties in both dispersed and continuous phases led to intimate contact between the two phases and thus defect‐free interfacial morphology, due to the supramolecular interlocking and π–π stacking interaction between triptycene units presented in both phases. The filler/polymer solution showed shear thickening behavior due to such strong interfacial interaction. The separation performance of the prepared composite membranes was investigated as a function of filler loading and particle surface grafting density. Pure‐gas permeation results showed that the gas permeabilities increased expectedly as the filler loading increased, with stable or improved selectivities. The reduced permeability relative to pristine polyimide film is likely due to the pore blockage of ZIF‐90 upon grafting triptycene moieties on the particle surface. Reducing the grafting density of triptycene moieties led to improved permeability and selectivity suggesting good tunability of this series of new composite membranes. Overall, modification of nanofiller with hierarchical triptycene moieties offers a fundamentally new avenue for creation of composite membranes with unique properties in gas separations.

Zhang, Qinnan↗

Simultaneous measurement of x-ray absorption spectra and kinetics : a fixed-bed, plug-flow operando reactor.

An inexpensive fixed-bed, plug-flow operando reactor is described in which X-ray absorbance and kinetic data can be measured simultaneously. Pt L3 (11.56 keV) XANES and EXAFS data were obtained on a 1.5% Pt/silica catalyst in borosilicate glass reactors of different diameters, 3-6 mm, and thicknesses, 0.3-1.2 mm, some of which are capable of operation at pressures up to about 40 atm. Additionally, polyimide tubular reactors with low absorbance can be used for lower energy edges of the 3d transition metals, or fluorescence detection for low concentration or highly absorbing supports. With the polyimide reactor, however, the pressure is limited to {approx}3.5 atm and the reaction temperature to about 300 C. To validate the reactor, the rate and activation energies for the water-gas shift reaction on 2% Pd, 13.7% Zn on Al2O3 catalyst were within 15% of those obtained in a standard laboratory reactor, which is within laboratory reproducibility. In addition, the Pd K edge (24.35 keV) XANES and EXAFS data on pre-reduced catalyst were identical to that previously determined on a regular cell. The EXAFS data show that the degree of Pd-Zn alloy formation changes with reaction temperature demonstrating the importance of characterizing the catalyst under reaction conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

New insights into structural evolution in carbon molecular sieve membranes during pyrolysis

Carbon molecular sieve (CMS) membranes separate penetrants using size and shape-selective pores. Here, we report pyrolysis of a 6FDA:BPDA-DAM polyimide precursor between 500 and 800 °C and measure gas evolution during the CMS structural development. The CMS materials were then characterized using combined transport properties, porosimetry, FTIR, Raman spectroscopy, TGA-FTIR, WARD, and elemental analysis measurements to assess their resulting physical and chemical properties. The results support a previous vision that fragmentation of the polyimide precursor occurs to form aromatic strands that provide building blocks for the overall CMS cell structure. This fact notwithstanding, these new findings determine that constituent strands appear to be more complicated than previously suggested. An ordering process of such strands can generate a bimodal morphology comprising larger micropores with irregular cell walls containing ultramicropores. Permeability and permselectivity of the CMS for the C 2 H 4 /C 2 H 6 pair are also correlated with CMS structures based on the above characterizations. The results of this work suggest that molecular probe-based transport measurements are by far the most useful tools to study these complex, amorphous materials for molecular separation applications.

36 MATERIALS SCIENCE↗