Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “plant effluent”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Treatment of antibiotic-manufacturing wastewater enriches for Aeromonas veronii, a zoonotic antibiotic-resistant emerging pathogen

Antibiotic-manufacturing wastewater treatment plants primarily target chemical pollutants, but their processes may select for antibiotic-resistant pathogens and antibiotic resistance genes. Leveraging the combined strengths of deep metagenomic sequencing, 16S rRNA gene sequencing, quantitative polymerase chain reaction, and bacterial culturing, we investigated bacterial communities and antibiotic resistomes across eleven treatment units in a full-scale antibiotic-manufacturing wastewater treatment plant processing wastewater from a β-lactam manufacturing facility. Both bacterial communities and antibiotic resistance gene compositions varied across the treatment units, but were associated. Certain antibiotic resistance gene persisted through treatment, either carried by identical bacterial species, or linked to mobile genetic elements in different species. Despite the satisfactory performance in chemical removal, this plant continuously enriched zoonotic antibiotic-resistant Aeromonas veronii (an emerging pathogen responsible for substantial economic losses in aquaculture and human health) from influent to effluent, probably due to prolonged β-lactam selection pressure and aquatic nature of A. veronii. This enrichment resulted in a significantly higher abundance of A. veronii than other aquatic samples worldwide. Furthermore, the closest evolutionary relative to the retrieved A. veronii was an isolate obtained from the stool of a local diarrhea patient. These findings highlighted a substantial public health risk posed by antibiotic-manufacturing wastewater treatment, underlining its potential role in enriching and disseminating zoonotic antibiotic-resistant pathogens. Beyond chemical monitoring, enhanced surveillance of antibiotic-resistant pathogens and antibiotic resistance genes is needed in effluent discharge standard for antibiotic-manufacturing wastewater treatment plants.

Wang, Xingshuo↗

Comparison of aerobically-treated and untreated crop residue as a source of recycled nutrients in a recirculating hydroponic system

This study compared the growth of potato plants on nutrients recycled from inedible potato biomass. Plants were grown for 105 days in recirculating, thin-film hydroponic systems containing four separate nutrient solution treatments: (1) modified half-strength Hoagland's (control), 2) liquid effluent from a bioreactor containing inedible potato biomass, 3) filtered (0.2 micrometer) effluent, and 4) the water soluble fraction of inedible potato biomass (leachate). Approximately 50% of the total nutrient requirement in treatments 2-4 were provided (recycled) from the potato biomass. Leachate had an inhibitory effect on leaf conductance, photosynthetic rate, and growth (50% reduction in plant height and 60% reduction in tuber yield). Plants grown on bioreactor effluent (filtered or unfiltered) were similar to the control plants. These results indicated that rapidly degraded, water soluble organic material contained in the inedible biomass, i.e., material in leachate, brought about phytotoxicity in the hydroponic culture of potato. Recalcitrant, water soluble organic material accumulated in all nutrient recycling treatments (650% increase after 105 days), but no increase in rhizosphere microbial numbers was observed.

NASA Discipline Life Support Systems↗

Fate of cellulose in primary and secondary treatment at municipal water resource recovery facilities

Abstract Cellulose from toilet paper is a significant fraction of particulate organics, which is recoverable. For the first time, comprehensive mapping and tracking the fate of cellulose across various unit processes at full‐scale in two water resource recovery facilities located in North America and Europe was undertaken. The influent cellulose content accounted for approximately one‐third of the total suspended solids (TSS). Although about 80% of the raw wastewater cellulose was removed in primary treatment, the type of primary treatment process (rotating belt filter [RBF] vs. primary clarification [PC]) had a significant impact on cellulose capture and diversion. The high cellulose content of the RBF sludge accounting for 35% of the TSS facilitates cellulose recovery. For the North American plant, with a conventional activated sludge process (SRT of 6–7 days, preceded by PC), cellulose biodegradation efficiencies of 70%–90% of the PC effluent were observed in summer and winter. For the European plant, with a modified University of Cape Town process (SRT of 14 days, without primary treatment in train 2, or preceded by RBF in train 1), comparable cellulose biodegradation efficiencies were also observed. Results from laboratory SBRs indicated that cellulose biodegradation efficiency at room temperature was 86% of the influent cellulose. Practitioner points Cellulose fate was tracked across two different WWTPs in two different geographies. Cellulose in the influent wastewater accounted for 1/3 of the total suspended solids. Primary treatments were able to capture more than 80% of the influent cellulose. Cellulose was biodegraded in secondary treatment, resulting an effluent of 2–3 mg/L.

Ahmed, Ahmed Shawki↗

NEWTS EPA Ash Dataset

Data from the US EPA Ash Database containing Ash pond effluent data from selected U.S. coal power plants. Original data from: Nguyen, Dan-Tam, Eastern Research Group. Sep 29, 2015. Analytical Database for the Steam Electric Rulemaking - DCN SE05359. https://www.regulations.gov/document/EPA-HQ-OW-2009-0819-5640

Ash Pond↗

NEWTS EPA Gasification Dataset and Case Studies

Data from the US EPA Gasification Database containing gasification effluent data from selected U.S. coal power plants. Original data from: Nguyen, Dan-Tam, Eastern Research Group. Sep 29, 2015. Analytical Database for the Steam Electric Rulemaking - DCN SE05359. https://www.regulations.gov/document/EPA-HQ-OW-2009-0819-5640 Files include: Original data tab, processed data and charge balance information in "NEWTS_EPA_Gasification_Effluent_Dataset_all_tabs.xlsx" Individual .csv files for data in format for input into aqueous chemistry modeling software (OLI Systems and Geochemist's Workbench) Data input templates for modeling streams in OLI Systems and Geochemist's Workbench Case studies for selected solved streams modeled in OLI Systems and Geochemist's Workbench

gasification↗

Analysis of microplastics in bivalves along Fourmile Branch

Microplastics are commonly found near wastewater treatment facilities with the source originating typically from fibers associated with laundry detergents. Fourmile branch would have limited laundry associated effluent and does not receive any input from water originating from upstream industry sources, therefore microplastics would have originated from Site operations or through atmospheric deposition which are both unexplored pathways. In order to assess environmental inventory effects on the biota, water samples were collected from sampling locations along Fourmile Branch on the Savannah River Site using plankton nets and grab samples at Fourmile Branch locations (i.e., FM-2B, FM-A7, and FM6). Fourmile Branch has a long history of receiving industrial effluents from site operations as well effluent from the site’s wastewater treatment plant. Water samples and the debris collected in the nets were rinsed with deionized water and sieved to remove the larger fractions of plastics (4000-2000 µm) and retain fractions <500 µm. The water samples were analyzed for the type and size of plastics by μ-Raman, mass spectrometry, and Fourier Transform Infrared Spectroscopy (FTIR) methods. Previously collected bivalves were prepared into thin sections and analyzed using microscopy.

54 ENVIRONMENTAL SCIENCES↗

Tritium issues in commercial pressurized water reactors

Tritium has become an important radionuclide in commercial Pressurized Water Reactors because of its mobility and tendency to concentrate in plant systems as tritiated water during the recycling of reactor coolant. Small quantities of tritium are released in routine regulated effluents as liquid water and as water vapor. Tritium has become a focus of attention at commercial nuclear power plants in recent years due to inadvertent, low-level, chronic releases arising from routine maintenance operations and from component failures. Tritium has been observed in groundwater in the vicinity of stations. The nuclear industry has undertaken strong proactive corrective measures to prevent recurrence, and continues to eliminate emission sources through its singular focus on public safety and environmental stewardship. This paper will discuss: production mechanisms for tritium, transport mechanisms from the reactor through plant, systems to the environment, examples of routine effluent releases, offsite doses, basic groundwater transport and geological issues, and recent nuclear industry environmental and legal ramifications. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The development and initial testing of the Ice Pig cleaning method for nuclear reprocessing plants - 15363

There are numerous situations throughout the nuclear industry where it would be advantageous to clean out enclosed systems, e.g. ducts and pipes, to remove sediments and radioactive contamination. However, conventional flushing methods result in the production of significant volumes of contaminated liquor. The wall Shear achieved with water flushing is insufficient to remove and carry dense deposits often found in nuclear facilities. Conventional mechanical pigs can be propelled through the duct by application of a driving medium such as compressed air or water. These are able to achieve very high wall shears, but can also get physically stuck where there is variation in the pipe / duct diameter or small radius bends. The field of application is best suited to straight constant diameter systems with no discontinuities such as Tee pieces, valves and in-pipe instrumentation. Driven by the desire to clean and displace radioactive materials from complex topology ducts and pipes, without the risk of having conventional pigs becoming lodged in a plant and coupled with the need to minimize effluent volumes, the UK Nuclear Industry led by Sellafield Limited (on behalf of the UK Nuclear Decommissioning Authority), has worked to demonstrate and underpin the use of the ice pigging technology for the nuclear industry. It is found that high ice fraction slurries flow as viscous liquids that exhibit a number of mechanical properties that offer much higher shear rates. The 'Ice Pig' exerts shear rates on pipe walls which are typically 1000 times greater than those achieved with water flowing at the same velocity. The 'Ice Pig' is able to negotiate almost any topology, flow through pipe networks of vastly differing diameter, through heat exchangers and in-line instrumentation etc. Experimental data and operational experience from other industries demonstrates that whilst there is high shear, the 'Ice Pig' does not damage the surface of the pipe wall. A further attractive characteristic of the 'Ice Pig' is that it eventually melts rendering it a simple effluent for processing by downstream processes. Due to the special nature of ice slurry, its unique rheological and physical characteristics, together with the complementary underpinning experimental work undertaken by Sellafield Limited enables the Ice Pigging process to move from an 'interesting' technology to one suitable for use by the nuclear industry for operations, Post Operational Clean Out (POCO) and decommissioning. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cesium Isotope Ratios as Indicators of Nuclear Power Plant Operations

There are multiple paths by which radioactive cesium can reach the effluent from reactor operations. The radioactive 135Cs/137Cs ratios are controlled by these paths. In an effort to better understand the origin of this radiation, these 135Cs/137Cs ratios in effluents from three power reactor sites have been measured in offsite samples. These ratios are different from global fallout by up to six fold and as such cannot have a significant component from this source. A cesium ratio for a sample collected outside of the plant boundary provides integration over the operating life of the reactor. A sample collected inside the plant at any given time can be much different from this lifetime ratio. The measured cesium ratios vary significantly for the three reactors and indicate that the multiple paths have widely varying levels of contributions. There are too many ways these isotopes can fractionate to be useful for quantitative evaluations of operating parameters in an offsite sample, although it may be possible to obtain limited qualitative information for an onsite sample.

137Cs↗

Decontamination of industrial cyanide-containing water in a solar CPC pilot plant

The aim of this work was to improve the quality of wastewater effluent coming from an Integrated Gasification Combined-Cycle (IGCC) power station to meet with future environmental legislation. This study examined a homogeneous photocatalytic oxidation process using concentrated solar UV energy (UV/Fe(II)/H{sub 2}O{sub 2}) in a Solar Compound Parabolic Collector (CPC) pilot plant. The efficiency of the process was evaluated by analysis of the oxidation of cyanides and Total Organic Carbon (TOC). A factorial experimental design allowed the determination of the influences of operating variables (initial concentration of H{sub 2}O{sub 2}, oxalic acid and Fe(II) and pH) on the degradation kinetics. Temperature and UV-A solar power were also included in the Neural Network fittings. The pH was maintained at a value >9.5 during cyanide oxidation to avoid the formation of gaseous HCN and later lowered to enhance mineralization. Under the optimum conditions ([H{sub 2}O{sub 2}] = 2000 ppm, [Fe(II)] = 8 ppm, pH = 3.3 after cyanide oxidation, and [(COOH){sub 2}] = 60 ppm), it was possible to degrade 100% of the cyanides and up to 92% of Total Organic Carbon. (author)

14 SOLAR ENERGY↗

Plant maintenance and plant life extension issue, 2009

The focus of the March-April issue is on plant maintenance and plant life extension. Major articles include the following: Application of modeling and simulation to nuclear power plants, by Berry Gibson, IBM, and Rolf Gibbels, Dassault Systems; Steam generators with tight manufacturing procedures, by Ei Kadokami, Mitsubishi Heavy Industries; SG design based on operational experience and R and D, by Jun Tang, Babcock and Wilcox Canada; Confident to deliver reliable performance, by Bruce Bevilacqua, Westinghouse Nuclear; An evolutionary plant design, by Martin Parece, AREVA NP, Inc.; and, Designed for optimum production, by Danny Roderick, GE Hitachi Nuclear Energy. Industry Innovation articles include: Controlling alloy 600 degradation, by John Wilson, Exelon Nuclear Corporation; Condensate polishing innovation, by Lewis Crone, Dominion Millstone Power Station; Reducing deposits in steam generators, by the Electric Power Research Institute; and, Minimizing Radiological effluent releases, by the Electric Power Research Institute. The plant profile article is titled 2008 - a year of 'firsts' for AmerenUE's Callaway plant, by Rick Eastman, AmerenUE.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Peroxide Decomposer Module Catalyst Testing to Support Preparations for Increased Demand - 19052

The Hanford Site Effluent Treatment Facility's (ETF) mission is to receive, treat, and dispose of liquid effluents from on-site programs and projects. Its roles in the management and mitigation of tank waste volume is integral to the overall Hanford tank farms mission, as tank space is limited. ETF's role will become even more essential as the Direct-Feed Low Activity Waste process comes online at the Waste Treatment and Immobilization Plant (WTP). In order to accommodate the additional liquid effluent streams, the ETF will undergo a number of facility and equipment upgrades. Included in this is the reinstatement of the Peroxide Decomposer Module (PDM) into the ETF's main treatment train. The PDM is used to remove any residual hydrogen peroxide not fully consumed in the preceding ultraviolet/oxidation (UV/OX) treatment stage for organic destruction. Future waste stream estimates have been shown to contain organic content requiring excess hydrogen peroxide addition. Restoration of the PDM will ensure the ETF can accommodate the higher anticipated levels of organic content in these new influent streams. Due to low organic content levels in the current influents and some operability issues with the PDM, it has not been in operation since 1998. One aspect of the repair and upgrade of the PDM is the usability of manganese dioxide on alumina catalyst, Sud-Chemie T-2525, which was purchased in 2008 but has remained in storage since. The manufacturer of the catalyst states there is no known shelf life for the product and no current data to indicate the catalyst's performance after long-term storage. To determine the usability of the stored catalyst, a laboratory test was developed. The testing of this stored catalyst was based on testing methods and information collected from initial catalyst product testing performed in 2008. This test involved spiking the catalyst with 200 ppm hydrogen peroxide and then testing the resulting solution to determine the extent of peroxide destruction. Initial testing results of the Sud-Chemie T-2525 catalyst indicated reduced performance, so additional catalyst materials were selected for inclusion in the testing. These materials included Carulite{sup R} 200 catalyst, LayneOx{sup R}, natural manganese ore - pyrolusite (Pro-Ox{sup R}), and EnviCat{sup R} 2531 SPH 4-6. With the expansion of the test scope, fines generation testing was added to provide additional data for product selection, as excessive fines cause plugging in the PDM. The resulting test data are compared to the 2008 catalyst product testing data in order to evaluate performance of each product to determine whether the Sud-Chemie T-2525 is still viable and to determine the best candidate for its replacement. This testing provides essential information to the engineering and operations organizations managing the facility and equipment upgrades for the ETF. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Rinsing Effluent Evaporator for Dismantling Operations - 13271

Between 1958 and 1997, the UP1 plant at Marcoule - located in the south of France - reprocessed and recycled nearly 20,000 MT of used fuel from special defense applications reactors, as well as fuel from the first generation of electricity generating reactors in France (natural uranium fuel, CO{sub 2}-cooled, graphite-moderated). Decommissioning and Dismantling of the UP1 plant and its associated units started in 1998. Since 2005, the UP1 facility has been operated by AREVA as the Marcoule Management and Operation contractor for French Atomic Energy Commission (CEA). An important part of this decommissioning program deals with the vitrification facility of Marcoule. This facility includes 20 tanks devoted to interim storage of highly active solutions, prior to vitrification. In 2006, a rinsing program was defined as part of the tank cleanup strategy. The main objective of the rinsing phases was to decrease activity in order to limit the volume of 'long-life active' waste produced during the decommissioning operations, so the tanks can be dismantled without the need of remote operations. To enable this rinsing program, and anticipating large volumes of generated effluent, the construction of an evaporation unit proved to be essential. The main objective of this unit was to concentrate the effluent produced during tank rinsing operations by a factor of approximately 10, prior to it being treated by vitrification. The evaporator design phase was launched in September 2006. The main challenge for the Project team was the installation of this new unit within a nuclear facility still in operation and in existing compartments not initially designed for this purpose. Cold operating tests were completed in 2008, and in May 2009, the final connections to the process were activated to start the hot test phase. During the first hot test operations performed on the first batches of clean-up effluent, the evaporator had a major operating problem. Extremely large quantities of foam were produced, affecting the evaporator operation, and creating the risk of a reduction in its capacity and throughput performance. A task force of AREVA process, operations, and safety experts from Marcoule and the La Hague reprocessing complex was assembled. New operating parameters were defined and tested to improve the process. Since then, the evaporator has performed very satisfactorily. The foam buildup phenomenon has been brought under complete control. All the different types of effluents produced during cleanup operations have been concentrated, and the results obtained in terms of quality and throughput, have ensured a consistent supply to the vitrification unit. The evaporator was operated until the end of April 2012, and enabled the production of 500 cubic meters of very high activity effluent, concentrating the fission products rinsed from the storage tanks. The evaporator will now be deactivated and decommissioned, with the first rinsing and cleanup operations scheduled to begin in 2014. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Cesium Ion Exchange Testing Using Crystalline Silicotitanate with Hanford Tank Waste 241-AP-107

Pacific Northwest National Laboratory has been tasked with demonstrating the unit operations for the Low Activity Waste Pretreatment System with actual Hanford tank waste. Crystalline silicotitanate (CST) ion exchange media is planned to be used to remove cesium (137Cs) from the aqueous phases of the tank wastes. Washington River Protection Solutions requested that Hanford tank waste collected from tank 241-AP-107 be processed using conceived pretreatment steps (suspended solids removal by filtration, Cs removal by ion exchange), then vitrified. Removal of Cs from these wastes is an important processing step in preparing the waste for long-term safe storage. Bench-scale ion exchange testing with approximately 9 L of filtered AP-107 supernate was conducted using CST. Column testing was performed using prototypic LAWPS operations in a lead-lag column arrangement using 10-mL CST beds. Feed was processed until the lag column effluent reached the Hanford Tank Waste Treatment and Immobilization Plant waste acceptance criteria (WAC) for receiving supernatant waste for vitrification (a function of the Na and 137Cs concentrations), at which point, a new lag column was needed to continue processing and the original lag column was moved to the lead position. Greater than 99% of the Cs processed through the ion exchange system was collected on the CST in the columns. The AP-107 feed and column processing effluent underwent extensive characterization to better define waste characteristics and assess fractionation to the CST. Selected lead column samples were analyzed to assess particular metal analyte load characteristics. Results of these analyses will be discussed.

cesium exchange, Hanford tank waste, ion exchange↗

AVANTech's Liquid Radwaste (LRW) Processing System Upgrade at the Farley Nuclear Plant - 20328

This paper looks at the Liquid Radioactive Waste (LRW) processing system configuration at Joseph M. Farley Nuclear Plant (Plant Farley). A combination of factors led the staff at Plant Farley to seek a better way to manage and process liquid waste. These factors were: - Reduce effluent activity; - Reduce waste volume; - Improve cost efficiency. The LRW processing system changes made at Plant Farley are identified and discussed. The information and technologies cited in this paper are directly applicable to other nuclear power plants who might contemplate an upgrade of LRW processing systems or of individual system components. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Preliminary Evaluation of Exchange of Hydrogen Isotopes in the Structure of a Mordenite-Based Sorbent

Silver-exchanged sodium mordenite (AgZ) is being evaluated as a sorbent to remove iodine from process effluent streams of used nuclear fuel (UNF) treatment plants. Previous studies have shown that AgZ adsorbs significant quantities of water, in addition to the iodine, from a humidified gas phase. The water within the plant is contaminated with tritiated water, particularly the water arising from the head-end treatment processes. Although methods to reduce or prevent the accumulation of water with the iodine have been devised and demonstrated, a concern arises that contact with tritiated water will permit an exchange of some of the stable hydrogen in the mordenite structure for tritium. The tritium thusly incorporated into the structure will likely remain in the mordenite even after thermal treatment to remove the physisorbed surface water. Subsequent processes that might destroy the structure (e.g., vitrification where the crystal may dissolve in molten glass) have the potential to release the tritium (or tritiated water), thereby representing another potential pathway for release of tritium to the environment. The purpose of the present study is to evaluate the exchange of hydrogen isotopes in the mordenite structure with hydrogen isotopes associated with fluids in contact with the mordenite.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Technoeconomic Optimization of Waste Heat Driven Forward Osmosis for Flue Gas Desulfurization Wastewater Treatment

With the Environmental Protection Agency’s recent Effluent Limitation Guidelines for Steam Electric Generators, power plants are having to install and operate new wastewater technologies. Many plants are evaluating desalination technologies as possible compliance options. However, the desalination technologies under review that can reduce wastewater volume or treat to a zero-liquid discharges standard have a significant energy penalty to the plant. Waste heat, available from the exhaust gas or cooling water from coal-fired power plants, offers an opportunity to drive wastewater treatment using thermal desalination technologies. One such technology is forward osmosis (FO). Forward osmosis utilizes an osmotic pressure gradient to passively pull water from a saline or wastewater stream across a semi-permeable membrane and into a more concentrated draw solution. This diluted draw solution is then fed into a distillation column, where the addition of low temperature waste heat can drive the separation to produce a reconcentrated draw solution and treated water for internal plant reuse. The use of low-temperature waste heat decouples water treatment from electricity production and eliminates the link between reducing water pollution and increasing air emissions from auxiliary electricity generation. In order to evaluate the feasibility of waste heat driven FO, we first build a model of an FO system for flue gas desulfurization (FGD) wastewater treatment at coal-fired power plants. This model includes the FO membrane module, the distillation column for draw solution recovery, and waste heat recovery from the exhaust gas. We then add a costing model to account for capital and operating costs of the forward osmosis system. We use this techno-economic model to optimize waste heat driven FO for the treatment of FGD wastewater. We apply this model to three case studies: the National Energy Technology Laboratory (NETL) 550 MW model coal fired power plant without carbon capture and sequestration, the NETL 550 MW model coal fired power plant with carbon capture and sequestration, and Plant Bowen in Eularhee, Georgia. For each case, we identify the design that minimizes the cost of wastewater treatment given the safely recoverable waste heat. We benchmark the cost minimum waste-heat forward osmosis solutions to two conventional options that rely on electricity, reverse osmosis and mechanical vapor recompression. Furthermore, we quantify the environmental damages from the emissions of carbon dioxide and criteria air pollutants for each treatment option. With this information we can assess the trade-offs between treatment costs, energy consumption, and air emissions between the treatment options.

20 FOSSIL-FUELED POWER PLANTS↗

Enrichments of Anaerobic Selenium Oxyanion Reducers from FGD Wastewater Effluent

Flue gas desulfurization systems (FGD) mitigate air pollutants from coal fired power plants. However, such systems produce wastewater that contains other pollutants such as mercury, arsenic, nitrogen, and selenium that must be removed before the water is released back into the environment. Selenium is of interest because chronic low doses of selenium (ng/L) can cause detrimental ecological consequences. Biological treatment can be utilized to remove selenium from FGD wastewater, but the microorganisms involved in this process and environment within the FGD effluent have not been well studied. This study identifies the microorganisms in selenate-enriched and selenite-enriched FGD effluent that can reduce selenium oxyanions to elemental selenium. Knowing more about these organisms can lead to an eventual optimization in the biological removal of selenium species in these wastewaters.

Sarkar, Preom↗