Frequency stability requirements for two way range rate tracking
Accuracy limitations to two way range rate Doppler tracking due to master (reference) oscillator frequency instabilities are discussed. Theory is developed to treat both the effects of random and nonrandom oscillator instabilities. The nonrandom instabilities treated are drift, environmental effects, and coherent phase modulation. The effects of random instabilities on range rate accuracy are shown to be describable in terms of sigma y (2, T, tau). For the typical noise processes encountered in precision oscillators, range rate error is related to the more familiar sigma y (tau) and script L (f). Three examples are discussed to show how to determine range rate error from given sigma y (tau) or script L (f) curves, and approximations are developed to simplify the treatment of complex systems. An error analysis of range determined from rate data is also given.