Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “performance test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Thermodynamic Vent System Performance Testing with Subcooled Liquid Methane and Gaseous Helium Pressurant

Due to its high specific impulse and favorable thermal properties for storage, liquid methane (LCH4) is being considered as a candidate propellant for exploration architectures. In order to gain an -understanding of any unique considerations involving micro-gravity pressure control with LCH4, testing was conducted at the Marshall Space Flight Center using the Multipurpose Hydrogen Test Bed (MHTB) to evaluate the performance of a spray-bar thermodynamic vent system (TVS) with subcooled LCH4 and gaseous helium (GHe) pressurant. Thirteen days of testing were performed in November 2006, with total tank heat leak conditions of about 715 W and 420 W at a fill level of approximately 90%. The TVS system was used to subcool the LCH4 to a liquid saturation pressure of approximately 55.2 kPa before the tank was pressurized with GHe to a total pressure of 165.5 kPa. A total of 23 TVS cycles were completed. The TVS successfully controlled the ullage pressure within a prescribed control band but did not maintain a stable liquid saturation pressure. This was likely. due to a TVS design not optimized for this particular propellant and test conditions, and possibly due to a large artificially induced heat input directly into the liquid. The capability to reduce liquid saturation pressure as well as maintain it within a prescribed control band, demonstrated that the TVS could be used to seek and maintain a desired liquid inlet temperature for an engine (at a cost of propellant lost through the TVS vent). One special test was conducted at the conclusion of the planned test activities. Reduction of the tank ullage pressure by opening the Joule-Thomson valve (JT) without operating the pump was attempted. The JT remained open for over 9300 seconds, resulting in an ullage pressure reduction of 30 kPa. The special test demonstrated the feasibility of using the JT valve for limited ullage pressure reduction in the event of a pump failure.

Flachbart, R. H.↗

Performance Testing of Yardney Li-Ion Cells and Batteries in Support of JPL's 2009 Mars Science Laboratory Mission

In 2009, JPL is planning to launch an unmanned rover mission to the planet Mars. This mission, referred to as the Mars Science Laboratory (MSL), will involve the use of a rover that is much larger than the previously developed Spirit and Opportunity Rovers for the 2003 Mars Exploration Rover (MER) mission, that are currently still in operation on the surface of the planet after more than three years. Part of the reason that the MER rovers have operated so successfully, far exceeding the required mission duration of 90 sols, is that they possess robust Li-ion batteries, manufactured by Yardney Technical Products, which have demonstrated excellent life characteristics. Given the excellent performance characteristics displayed, similar lithium-ion batteries have been projected to successfully meet the mission requirements of the up-coming MSL mission. Although comparable in many facets, such as being required to operate over a wide temperature range (-20 to 40 C), the MSL mission has more demanding performance requirements compared to the MER mission, including much longer mission duration (approx. 687 sols vs. 90 sols), higher power capability, and the need to withstand higher temperature excursions. In addition, due to the larger rover size, the MSL mission necessitates the use of a much larger battery to meet the energy, life, and power requirements. In order to determine the viability of meeting these requirements, a number of performance verification tests were performed on 10 Ah Yardney lithium-ion cells (MER design) under MSL-relevant conditions, including mission surface operation simulation testing. In addition, the performance of on-going ground life testing of 10 Ah MER cells and 8-cell batteries will be discussed in the context of capacity loss and impedance growth predictions.

MSL Rover↗

Performance tests of a thermionic converter with an oxygenated cesium reservoir

Cesium oxide/cesium solutions as a possible source of oxygen and cesium are investigated. A converter-reservoir system which allows multiple additions of oxygen with intervening thermionic performance tests was developed. The experimental data cover the cesium oxide mole fraction range of 0 to 0.018 with thermionic performance measurements in the emitter temperature range of 1600 to 1900 K. The data showed that the thermionic performance was unaffected by the presence of cesium oxide in this mole fraction range and higher mole fractions appear to be required for the proper oxygen arrival rate at the emitter surface.

Gunther, B.↗

Heavy Duty Hydrogen: Reference Station, Fueling Performance Test Device Concepts, and Station Capacity Model (CRADA Final Report)

This project will provide valuable information on (1) reference station design, (2) exploration of design concepts for a fueling performance test device, and (3) modeling of station capacity. The work applies to heavy-duty (HD) hydrogen fueling stations with large dispensing capacity and high flowrates servicing HD hydrogen trucks such as class 8 trucks in long haul applications. Additionally, a 4th area will provide near-real-time verification of fuel quality with on-site hydrogen contaminant detectors (HCDs) for use at both light-duty (LD) and HD stations. The work leverages national lab capabilities including staff and equipment at SNL, NLR, and ANL with collaboration and funding cost share from California agencies (CEC, SCAQMD, and GO-Biz). This project will provide tools and information that lead to more efficient design, acceptance, and commissioning of these larger capacity, higher flowrate stations serving HD applications. The HCD work will benefit both LD and HD stations. Note: The 4th area (HCD) mentioned above continued outside of this CRADA and will not be included in this report. There are no tasks included in this CRADA for HCD and the summary text for it should have been removed prior to this CRADA contract execution but remained in error and is included here for completeness.

08 HYDROGEN↗

Performance tests of a cryogenic hybrid magnetic bearing for turbopumps

Experiments were performed on a Hybrid Magnetic Bearing designed for cryogenic applications such as turbopumps. This bearing is considerably smaller and lighter than conventional magnetic bearings and is more efficient because it uses a permanent magnet to provide a bias flux. The tests were performed in a test rig that used liquid nitrogen to simulate cryogenic turbopump temperatures. The bearing was tested at room temperature and at liquid nitrogen temperature (-320 F). The maximum speed for the test rig was 14000 rpm. For a magnetic bearing stiffness of 20000 lb/in, the flexible rotor had two critical speeds. A static (nonrotating) bearing stiffness of 85000 lb/in was achieved. Magnetic bearing stiffness, permanent magnet stiffness, actuator gain, and actuator force interaction between two axes were evaluated, and controller/power amplifier characteristics were determined. The tests revealed that it is feasible to use this bearing in the cryogenic environment and to control the rotor dynamics of flexible rotors when passing through bending critical speeds. The tests also revealed that more effort should be placed on enhancing the controller to achieve higher bearing stiffness and on developing displacement sensors that reduce drift caused by temperature and reduce sensor electrical noise.

Dirusso, Eliseo↗

Performance Testing of the Engineering Model Astro-H 3-stage ADR

The Japanese Astro-H mission will include the Soft X-ray Spectrometer (SXS) instrument provided by NASA/GSFC. The SXS will perform imaging spectroscopy in the soft x-ray band using a 6x6 array of silicon microcalorimeters operated at 50 mK. The detectors are cooled by a 3-stage adiabatic demagnetization refrigerator (ADR), which is configured to use either a 1.3 K superfluid helium tank or a 4.5 K Joule-Thomson cryocooler as a heat sink. At present, the engineering model SXS, including the detectors and ADR, has been performance tested at GSFC and integrated with the EM dewar in Japan. The flight model SXS is currently being fabricated. This paper presents test results of the EM ADR and changes that will be implemented in the flight version.

Shirron, Peter J.↗

Results of data base management system parameterized performance testing related to GSFC scientific applications

The results of a variety of tests designed to demonstrate and evaluate the performance of several commercially available data base management system (DBMS) products compatible with the Digital Equipment Corporation VAX 11/780 computer system are summarized. The tests were performed on the INGRES, ORACLE, and SEED DBMS products employing applications that were similar to scientific applications under development by NASA. The objectives of this testing included determining the strength and weaknesses of the candidate systems, performance trade-offs of various design alternatives and the impact of some installation and environmental (computer related) influences.

Carchedi, C. H.↗

Non-Contacting Finger Seals Static Performance Test Results at Ambient and High Temperatures

The non-contacting finger seal is an advanced seal concept with potential to reduce specific fuel consumption in gas turbine engines by 2 to 3 with little to no wear of the seal or rotor. Static performance tests and bind-up tests of eight different non-contacting finger seal configurations were conducted in air at pressure differentials up to 689.4 kPa and temperatures up to 922 K. Four of the seals tested were designed to have lift pads concentric to a herringbone-grooved rotor which generates hydrodynamic lift when rotating. The remaining seals were tested with a smooth rotor; one seal had a circumferential taper and one had an axial taper on the lift pad inner diameter to create hydrodynamic lift during rotation. The effects of the aft finger axial thickness and of the forward finger inner diameter on leakage performance were investigated as well and compared to analytical predictions.

rotors↗

Non-Contacting Finger Seals Static Performance Test Results at Ambient and High Temperatures

The non-contacting finger seal is an advanced seal concept with potential to reduce specific fuel consumption in gas turbine engines by 2 to 3 percent with little to no wear of the seal or rotor. Static performance tests and bind-up tests of eight different non-contacting finger seal configurations were conducted in air at pressure differentials up to 689.4 kPa and temperatures up to 922 K. Four of the seals tested were designed to have lift pads concentric to a herringbone-grooved rotor which generates hydrodynamic lift when rotating. The remaining seals were tested with a smooth rotor; one seal had a circumferential taper and one had an axial taper on the lift pad inner diameter to create hydrodynamic lift during rotation. The effects of the aft finger axial thickness and of the forward finger inner diameter on leakage performance were investigated as well and compared to analytical predictions.

static tests↗

Development of a standardized battery of performance tests for the assessment of noise stress effects

A set of 36 relatively independent categories of human performance were identified. These categories encompass human performance in the cognitive, perceptual, and psychomotor areas, and include diagnostic measures and sensitive performance metrics. Then a prototype standardized test battery was constructed, and research was conducted to obtain information on the sensitivity of the tests to stress, the sensitivity of selected categories of performance degradation, the time course of stress effects on each of the selected tests, and the learning curves associated with each test. A research project utilizing a three factor partially repeated analysis of covariance design was conducted in which 60 male subjects were exposed to variations in noise level and quality during performance testing. Effects of randomly intermittent noise on performance of the reaction time tests were observed, but most of the other performance tests showed consistent stability. The results of 14 analyses of covariance of the data taken from the performance of the 60 subjects on the prototype standardized test battery provided information which will enable the final development and test of a standardized test battery and the associated development of differential sensitivity metrics and diagnostic classificatory system.

Theologus, G. C.↗

The XRS Low Temperature Cryogenic System: Ground Performance Test Results

The X-Ray Spectrometer (XRS) instrument is part of the Astro-E mission scheduled to launch early in 2000. Its cryogenic system is required to cool a 32-element square array of x-ray microcalorimeters to 60-65 mK over a mission lifetime of at least 2 years. This is accomplished using an adiabatic demagnetization refrigerator (ADR) contained within a two-stage superfluid helium/solid neon cooler. Goddard Space Flight Center is providing the ADR and helium dewar. The flight system was assembled in Sept. 1997 and subjected to extensive thermal performance tests. This paper presents test results at both the system and component levels. In addition, results of the low temperature topoff performed in Japan with the engineering unit neon and helium dewars are discussed.

Breon, Susan↗

Performance Testing of a Moving-Bed Gasifier Using Coal, Biomass, and Waste Plastic Blends to Generate White Hydrogen

The objective of this DOE-funded project by the Electric Power Research Institute, Inc. (EPRI), Hamilton Maurer International (HMI) and Sotacarbo S.p.A. (Sotacarbo), is to qualify coal, biomass, and plastic waste blends based on performance testing of selected pellet recipes in a pilot-scale updraft moving-bed gasifier. The testing provides relevant data to advance the commercial-scale design of the moving-bed gasifier to be able to successfully use these feedstocks to produce hydrogen. In particular, the effects of the waste plastics on feedstock development (i.e., blending and pelletizing) and the resulting products (i.e., syngas compositions, organic condensate production, and ash characteristics) are a focus. The gasifier is Hamilton Mauer International, Inc. (HMI)’s moving-bed gasifier, which has been proven capable of gasifying nearly all coal ranks. It has also shown the ability in prior testing work to gasify wood chips. However, mixtures of these fuels with plastic wastes had not yet been prepared and gasified together. The feedstocks were prepared by California Pellet Mill (CPM) under contract to HMI.

01 COAL, LIGNITE, AND PEAT↗

Annual Performance Testing of Tracer Gas and Tracer Aerosol Detectors for use in Radionuclide NESHAP Compliance Testing

Los Alamos National Laboratory’s (LANL’s) compliance with Radionuclide NESHAP 1 regulations is managed by the Radionuclide Air Emissions Management (RAEM) team, part of LANL’s Compliance Programs group (EPC-CP). One area of the Radionuclide NESHAP addresses requirements for siting a stack sample system. This memo documents the most recent performance tests of the sulfur hexafluoride detectors for use in stack gas mixing tests, as well as the functional trending test on a pair of optical particle counters, comparing results from a non-calibrated instrument to a calibrated instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance Testing of a Photocatalytic Oxidation Module for Spacecraft Cabin Atmosphere Revitalization

Photocatalytic oxidation (PCO) is a candidate process technology for use in high volumetric flow rate trace contaminant control applications in sealed environments. The targeted application for PCO as applied to crewed spacecraft life support system architectures is summarized. Technical challenges characteristic of PCO are considered. Performance testing of a breadboard PCO reactor design for mineralizing polar organic compounds in a spacecraft cabin atmosphere is described. Test results are analyzed and compared to results reported in the literature for comparable PCO reactor designs.

Perry, Jay L.↗

Performance tests of a gas blending system based on mass-flow controllers

The system provides many of the gas mixtures required for calibrating analytical instruments used in engine exhaust gas analysis and is capable of blending from one to four additive gases with either of two carrier gases in concentrations from 20 ppm to 50%. Two mixtures can be flowing simultaneously. Performance tests were made to determine the stability accuracy of the system while it was in limited use for a period of 2 years. The accuracy of the blender was measured by comparing binary mixtures from the blender with National Bureau of Standards standard reference materials. Analytical instruments were used to make these comparisons. The expected accuracy of 2% was obtained in some of the tests, by the majority showed a systematic biAs of -5%. Although these tests revealed subtle instabilities in the flow controllers that contributed to the random scatter of data, the accuracy of wet test meters and bubble flowmeters used for calibration is marginal for this purpose. A simple procedure is recommended that should enable the full potential of the system to be realized.

Evans, A., Jr.↗