Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “performance envelope”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Hygrothermal Performance of Bio-Based Materials in Residential Building Wall Envelope Systems

In the United States, building envelope systems contribute approximately 28% of building energy consumption, with walls being a primary factor. As the construction industry explores new approaches to lower the energy intensity needed to manufacture materials and, in turn, reduce energy consumption, bio-based materials are gaining attention as a promising alternative. While prior studies have demonstrated that bio-based materials can decrease material energy intensity, their long-term hygrothermal behavior within a whole residential wall system is not yet fully understood. This study aims to evaluate the potential of replacing Oriented Strand Board (OSB) and drywall in residential wall systems with bio-based alternatives. The research focuses on two bio-based materials, assessing their hygrothermal performance under Chicago climate condition (Climate Zone 5). To achieve that, a series of laboratory experiments were conducted to measure key properties of the bio-based materials such as thickness, dimensions, density, thermal conductivity (as a function of temperature and humidity), moisture-dependent permeance and water vapor permeability (WVP), and sorption isotherms. These properties were then used in WUFI® simulations to predict the moisture durability of a standard residential wall system in Climate Zone 5. Results show that substituting OSB and drywall with bio-based materials can achieve acceptable moisture durability, effectively mitigating risks of mold growth and structural damage over time.

Palani, Hevar [ORNL] (ORCID:0000000220211994)↗

High Performance Commercial Fenestration Framing Systems

A major objective of the U.S. Department of Energy is to have a zero energy commercial building by the year 2025. Windows have a major influence on the energy performance of the building envelope as they control over 55% of building energy load, and represent one important area where technologies can be developed to save energy. Aluminum framing systems are used in over 80% of commercial fenestration products (i.e. windows, curtain walls, store fronts, etc.). Aluminum framing systems are often required in commercial buildings because of their inherent good structural properties and long service life, which is required from commercial and architectural frames. At the same time, they are lightweight and durable, requiring very little maintenance, and offer design flexibility. An additional benefit of aluminum framing systems is their relatively low cost and easy manufacturability. Aluminum, being an easily recyclable material, also offers sustainable features. However, from energy efficiency point of view, aluminum frames have lower thermal performance due to the very high thermal conductivity of aluminum. Fenestration systems constructed of aluminum alloys therefore have lower performance in terms of being effective barrier to energy transfer (heat loss or gain). Despite the lower energy performance, aluminum is the choice material for commercial framing systems and dominates the commercial/architectural fenestration market because of the reasons mentioned above. In addition, there is no other cost effective and energy efficient replacement material available to take place of aluminum in the commercial/architectural market. Hence it is imperative to improve the performance of aluminum framing system to improve the energy performance of commercial fenestration system and in turn reduce the energy consumption of commercial building and achieve zero energy building by 2025. The objective of this project was to develop high performance, energy efficient commercial fenestration framing systems, by investigating new technologies that would improve the thermal performance of aluminum frames, while maintaining their structural and life-cycle performance. The project targeted an improvement of over 30% (whole window performance) over conventional commercial framing technology by improving the performance of commercial framing systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Renewable Energy Requirements for Future Building Codes: Options for Compliance

As the model energy codes are improved to reach efficiency levels 50 percent greater than current codes, use of on-site renewable energy generation is likely to become a code requirement. This requirement will be needed because traditional mechanisms for code improvement, including envelope, mechanical and lighting, have been pressed to the end of reasonable limits. Research has been conducted to determine the mechanism for implementing this requirement (Kaufman 2011). Kaufmann et al. determined that the most appropriate way to structure an on-site renewable requirement for commercial buildings is to define the requirement in terms of an installed power density per unit of roof area. This provides a mechanism that is suitable for the installation of photovoltaic (PV) systems on future buildings to offset electricity and reduce the total building energy load. Kaufmann et al. suggested that an appropriate maximum for the requirement in the commercial sector would be 4 W/ft 2 of roof area or 0.5 W/ft 2 of conditioned floor area. As with all code requirements, there must be an alternative compliance path for buildings that may not reasonably meet the renewables requirement. This might include conditions like shading (which makes rooftop PV arrays less effective), unusual architecture, undesirable roof pitch, unsuitable building orientation, or other issues. In the short term, alternative compliance paths including high performance mechanical equipment, dramatic envelope changes, or controls changes may be feasible. These options may be less expensive than many renewable systems, which will require careful balance of energy measures when setting the code requirement levels. As the stringency of the code continues to increase however, efficiency trade-offs will be maximized, requiring alternative compliance options to be focused solely on renewable electricity trade-offs or equivalent programs. One alternate compliance path includes purchase of Renewable Energy Credits (RECs). Each REC represents a specified amount of renewable electricity production and provides an offset of environmental externalities associated with non-renewable electricity production. The purpose of this paper is to explore the possible issues with RECs and comparable alternative compliance options. Existing codes have been examined to determine energy equivalence between the energy generation requirement and the RECs alternative over the life of the building. The price equivalence of the requirement and the alternative are determined to consider the economic drivers for a market decision. This research includes case studies that review how the few existing codes have incorporated RECs and some of the issues inherent with REC markets. Section 1 of the report reviews compliance options including RECs, green energy purchase programs, shared solar agreements and leases, and other options. Section 2 provides detailed case studies on codes that include RECs and community based alternative compliance methods. The methods the existing code requirements structure alternative compliance options like RECs are the focus of the case studies. Section 3 explores the possible structure of the renewable energy generation requirement in the context of energy and price equivalence. The price of RECs have shown high variation by market and over time which makes it critical to for code language to be updated frequently for a renewable energy generation requirement or the requirement will not remain price-equivalent over time. Section 4 of the report provides a maximum case estimate for impact to the PV market and the REC market based on the Kaufmann et al. proposed requirement levels. If all new buildings in the commercial sector complied with the requirement to install rooftop PV arrays, nearly 4,700 MW of solar would be installed in 2012, a major increase from EIA estimates of 640 MW of solar generation capacity installed in 2009. The residential sector could contribute roughly an additional 2,300 MW based on the same code requirement levels of 4 W/ft 2 of roof area. Section 5 of the report provides a basic framework for draft code language recommendations based on the analysis of the alternative compliance levels.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

X-ray computed tomography-based porosity analysis: Algorithms and application for porous woody biomass

The properties of lignocellulosic biomass, such as bulk physical, thermal, and mechanical properties, as well as the mobility of enzymes or catalysts, are largely affected by porosity, pore structures, and pore size distribution. While X-ray computed tomography (CT) has been introduced to effectively produce 3D volumetric images of material microstructure, a quantitative porosity analysis from the 3D images has never been done. This work introduces a first-of-its-kind X-ray CT-based quantitative porosity analysis method and applies the developed toolkit to characterize the internal porosity distribution of loblolly pine. A sample loblolly pine chip was scanned by a nano-resolution X-ray CT system and digitally reconstructed after a sequence of image processing operations. Here, a comprehensive porosity analysis was then performed to quantify the envelope porosity, the spatial distribution of local porosity, and the directional porosity. Solutions to the various challenges in image processing, porosity calculation, and large data handling are provided.

42 ENGINEERING↗

Seismoacoustic Analysis of Chemical Explosions at the Nevada National Security Site

In recent years, two sets of chemical explosions have been conducted at the Nevada National Security Site (NNSS): 6 explosions from Phase I of the Source Physics Experiment (SPE) and 4 explosions from the Forensics Surface Events (FSE). We have estimated the explosive yield and depth-of-burial/height-of-burst of both from the synthesis of seismic and low-frequency acoustic data. Analysis of the seismic signal is performed using a waveform envelope technique. Using seismic data only, however, there is a tradeoff between the yield and depth or height of the explosion, which becomes especially acute for near-surface events. This tradeoff between yield and depth/height can be broken by including complementary analysis of the acoustic signal using the acoustic waveform inversion method. The acoustic signal also has a strong tradeoff between a yield and depth/height, but the slope is opposite that of the seismic for near-surface events. We use a likelihood function to combine the seismic and acoustic analysis and improve our estimates of yield and depth/height for these sets of explosions. The results are generally consistent with the known parameters, but can be improved upon by higher-frequency seismic analysis and improved acoustic impulse scaling for large scaled depths-of-burial. These events serve as prime examples of data fusion from multiple data streams. The challenge will be to apply the method to events at longer regional distances where the seismic signals will include phases traveling in the upper mantle, and the acoustic signals will be recorded as infrasound signals, which are subject to atmospheric variability.

58 GEOSCIENCES↗

Field Evaluation of Highly Insulating Windows in the Lab Homes: Winter Experiment

This field evaluation of highly insulating windows was undertaken in a matched pair of 'Lab Homes' located on the Pacific Northwest National Laboratory (PNNL) campus during the 2012 winter heating season. Improving the insulation and solar heat gain characteristics of a home's windows has the potential to significantly improve the home's building envelope and overall thermal performance by reducing heat loss (in the winter), and cooling loss and solar heat gain (in the summer) through the windows. A high quality installation and/or window retrofit will also minimize or reduce air leakage through the window cavity and thus also contribute to reduced heat loss in the winter and cooling loss in the summer. These improvements all contribute to decreasing overall annual home energy use. Occupant comfort (non-quantifiable) can also be increased by minimizing or eliminating the cold 'draft' (temperature) many residents experience at or near window surfaces that are at a noticeably lower temperature than the room air temperature. Lastly, although not measured in this experiment, highly insulating windows (triple-pane in this experiment) also have the potential to significantly reduce the noise transmittance through windows compared to standard double-pane windows. The metered data taken in the Lab Homes and data analysis presented here represent 70 days of data taken during the 2012 heating season. As such, the savings from highly insulating windows in the experimental home (Lab Home B) compared to the standard double-pane clear glass windows in the baseline home (Lab Home A) are only a portion of the energy savings expected from a year-long experiment that would include a cooling season. The cooling season experiment will take place in the homes in the summer of 2012, and results of that experiment will be reported in a subsequent report available to all stakeholders.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field Trial of an Aerosol-Based Enclosure Sealing Technology

This report presents the results from several demonstrations of a new method for sealing building envelope air leaks using an aerosol sealing process developed by the Western Cooling Efficiency Center at UC Davis. The process involves pressurizing a building while applying an aerosol sealant to the interior. As air escapes through leaks in the building envelope, the aerosol particles are transported to the leaks where they collect and form a seal that blocks the leak. Standard blower door technology is used to facilitate the building pressurization, which allows the installer to track the sealing progress during the installation and automatically verify the final building tightness. Each aerosol envelope sealing installation was performed after drywall was installed and taped, and the process did not appear to interrupt the construction schedule or interfere with other trades working in the homes. The labor needed to physically seal bulk air leaks in typical construction will not be replaced by this technology.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Corrosion Testing of Bubbler Materials for LAW Vitrification (Rev. 0)

This work involved crucible-scale corrosion tests using coupons of selected materials in the baseline glass formulations for the seven LAW Sub-Envelopes. The tests were performed with Inconel 690 and MA 758; per the Test Plan, selected tests were also performed with a proprietary high temperature alloy supplied by SRTC. Coupons of these materials were tested for their corrosion resistance to LAW baseline glasses in two test series: the first series was with a baseline glass only, the second series was with a baseline glass and an added salt layer.

36 MATERIALS SCIENCE↗

Impact of Space Heating Options on Electricity Rates and Affordability

Electricity prices have increased in many regions of the U.S., with a national average of 18 cents/kWh projected for 2026, up from 16 cents/kWh in 2020. While the increases can be attributed to a number of factors, increasing electricity use in an efficient and strategic manner - with energy efficient building envelope upgrades and high performance HVAC systems - has the potential to increase revenue for utilities without significantly increasing electricity demand, and therefore could help moderate rate increases. This effect has been studied for electric vehicle charging[1] and dual-fuel heat pumps in Minnesota[2]. Leveraging a recently developed system cost methodology and FERC data on utility revenue, spending, and profits, this poster will present the direction and relative magnitude of rate impacts for efficient space heating upgrades in utility balancing areas across the contiguous U.S., using current prices and showing how the rate impacts would evolve under future grid scenarios.

15 GEOTHERMAL ENERGY↗

Development of a Variable-Speed Residential Air-Source Integrated Heat Pump

A residential air-source integrated heat pump (AS-IHP) is under development in partnership with a U.S. manufacturer. A nominal 10.6 kW (3-ton) cooling capacity variable-speed unit, the system provides both space conditioning and water heating. This multi-functional unit can provide domestic water heating (DWH) in either full condensing (FC) (dedicated water heating or simultaneous space cooling and water heating) or desuperheating (DS) operation modes. Laboratory test data were used to calibrate a vapor-compression simulation model for each mode of operation. The model was used to optimize the internal control options for efficiency while maintaining acceptable comfort conditions and refrigerant-side pressures and temperatures within allowable operating envelopes. Annual simulations were performed with the AS-IHP installed in a well-insulated house in five U.S. climate zones. The AS-IHP is predicted to use 45 to 60% less energy than a DOE minimum efficiency baseline system while meeting total annual space conditioning and water heating loads. Water heating energy use is lowered by 60 to 75% in cold to warmer climates, respectively. Plans are to field test the unit in Knoxville, TN.

dual function↗

THE SOLAR ABUNDANCE PROBLEM: THE EFFECT OF THE TURBULENT KINETIC FLUX ON THE SOLAR ENVELOPE MODEL

Recent three-dimensional (3D) simulations have shown that the turbulent kinetic flux (TKF) is significant. We discuss the effects of TKF on the size of the convection zone and find that the TKF may help solve the solar abundance problem. The solar abundance problem is that, with new abundances, the solar convection zone depth, the sound speed in the radiative interior, the helium abundance, and the density in the convective envelope are not in agreement with helioseismic inversions. We have performed Monte Carlo simulations on solar convective envelope models with different profiles of TKF to test its effects. The solar abundance problem is revealed in the standard solar convective envelope model with AGSS09 composition, which shows significant differences (∼10)) in density from the helioseismic inversions, but the differences in the model with the old composition GN93 is small (∼0.5)). In the testing models with a different TKF imposed, it is found that the density profile is sensitive to the value of TKF at the base of the convective envelope and insensitive to the structure of TKF in the convection zone. The required value of turbulent kinetic luminosity at the base is about –13% to – 19% L {sub ☉}. Comparing with the 3D simulations, this value is plausible. This study is for the solar convective envelope only. Evolutionary solar models with TKF are required to investigat the effects of TKF on the solar interior structure below the convection zone and the whole solar abundance problem, but the profile of the TKF in the overshoot region is necessary.

79 ASTRONOMY AND ASTROPHYSICS↗

Three-dimensional radiation-hydrodynamics calculations of the envelopes of young planets embedded in protoplanetary disks

We perform global three-dimensional (3D) radiation-hydrodynamics calculations of the envelopes surrounding young planetary cores of 5, 10, and 15 Earth masses, located in a protoplanetary disk at 5 and 10 AU from a solar-mass star. We apply a nested-grid technique to resolve the thermodynamics of the disk at the orbital-radius length scale and that of the envelope at the core-radius length scale. The gas is modeled as a solar mixture of molecular and atomic hydrogen, helium, and their ions. The equation of state accounts for both gas and radiation, and gas energy includes contributions from rotational and vibrational states of molecular hydrogen and from ionization of atomic species. Dust opacities are computed from first principles, applying the full Mie theory. One-dimensional (1D) calculations of planet formation are used to supplement the 3D calculations by providing energy deposition rates in the envelope due to solids accretion. We compare 1D and 3D envelopes and find that masses and gas accretion rates agree within factors of 2, and so do envelope temperatures. The trajectories of passive tracers are used to define the size of 3D envelopes, resulting in radii much smaller than the Hill radius and smaller than the Bondi radius. The moments of inertia and angular momentum of the envelopes are determined and the rotation rates are derived from the rigid-body approximation, resulting in slow bulk rotation. We find that the polar flattening is ≲ 0.05. The dynamics of the accretion flow are examined by tracking the motion of tracers that move into the envelope. The anisotropy of this flow is characterized in terms of both its origin and impact site at the envelope surface. Gas merges with the envelope preferentially at mid- to high latitudes.

79 ASTRONOMY AND ASTROPHYSICS↗

Aerogel from Sustainably Grown Bacterial Cellulose Pellicles as a Thermally Insulative Film for Building Envelopes

Improving building energy performance requires the development of new highly insulative materials. An affordable retrofitting solution comprising a thin film could improve the resistance to heat flow in both residential and commercial buildings and reduce overall energy consumption. Here, we propose cellulose aerogel films formed from pellicles produced by the bacteria Gluconacetobacter hansenii as insulation materials. We studied the impact of the density and nanostructure on the aerogels’ thermal properties. A thermal conductivity as low as 13 mW/(K·m) was measured for native pellicle-based aerogels that were dried as-is with minimal post-treatment. The use of waste from the beer brewing industry as a solution to grow the pellicle maintained the cellulose yield obtained with standard Hestrin-Schramm media, making our product more affordable and sustainable. In the future, our work can be extended through further diversification of food wastes as the substrate sources, facilitating higher potential production and larger applications.

36 MATERIALS SCIENCE↗

THREE-DIMENSIONAL EXPLOSION GEOMETRY OF STRIPPED-ENVELOPE CORE-COLLAPSE SUPERNOVAE. I. SPECTROPOLARIMETRIC OBSERVATIONS

We study the multi-dimensional geometry of supernova (SN) explosions by means of spectropolarimetric observations of stripped-envelope SNe, i.e., SNe without a hydrogen-rich layer. We perform spectropolarimetric observations of two stripped-envelope SNe, Type Ib SN 2009jf and Type Ic SN 2009mi. Both objects show non-zero polarization at the wavelength of the strong lines. They also show a loop in the Stokes Q - U diagram, which indicates a non-axisymmetric, three-dimensional ion distribution in the ejecta. We show that five out of six stripped-envelope SNe, which have been observed spectropolarimetrically so far, show such a loop. This implies that a three-dimensional geometry is common in stripped-envelope SNe. We find that stronger lines tend to show higher polarization. This effect is not related to the geometry, and must be corrected for to compare the polarization of different lines or different objects. Even after the correction, however, there remains a dispersion of polarization degree among different objects. Such a dispersion might be caused by three-dimensional clumpy ion distributions viewed from different directions.

79 ASTRONOMY AND ASTROPHYSICS↗

Calibration of urban building energy model using smart meter data for district peak load prediction

Urban building energy modeling (UBEM) is a powerful approach to assessing baseline building energy performance and retrofits with new technologies across building stocks in cities. However, the accuracy of UBEM is often constrained by the limited availability of reliable data about building characteristics and operations, such as envelope efficiency levels, HVAC system performance, and end-use load patterns. Existing research has performed UBEM calibration using annual or monthly energy consumption data, which falls short when higher-resolution time series applications are needed, such as peak load prediction for utility operation planning. This study presents a new framework for calibrating building energy models at urban scale using smart meter data, targeting the accurate prediction of summer peak electricity loads to support robust grid planning. The framework first integrates various data sources to enhance baseline input assumptions for building models, and then calibrates the baseline models through a pattern-matching approach. A case study using CityBES and two years of AMI data from over 9000 residential customers in Portland, Oregon, demonstrated the workflow and its effectiveness. The calibrated models achieved a daily peak load mean absolute percentage error of 2.6 % during the heatwave in the calibration year, and 2.0 % in the validation year using another year of AMI data. Using the calibrated models, we analyzed the demand flexibility potential of the district building stock as an application of UBEM calibration. The findings affirm the appropriate use of UBEM for peak electric load forecasting and demand side management at the utility distribution system level.

AMI data↗

NEXT GENERATION MELTER(S) FOR VITRIFICATION OF HANFORD WASTE STATUS AND DIRECTION

Vitrification technology has been selected to treat high-level waste (HLW) at the Hanford Site, the West Valley Demonstration Project and the Savannah River Site (SRS), and low activity waste (LAW) at Hanford. In addition, it may potentially be applied to other defense waste streams such as sodium bearing tank waste or calcine. Joule-heated melters (already in service at SRS) will initially be used at the Hanford Site's Waste Treatment and Immobilization Plant (WTP) to vitrify tank waste fractions. The glass waste content and melt/production rates at WTP are limited by the current melter technology. Significant reductions in glass volumes and mission life are only possible with advancements in melter technology coupled with new glass formulations. The Next Generation Melter (NGM) program has been established by the U.S. Department of Energy's (DOE's), Environmental Management Office of Waste Processing (EM-31) to develop melters with greater production capacity (absolute glass throughput rate) and the ability to process melts with higher waste fractions. Advanced systems based on Joule-Heated Ceramic Melter (JHCM) and Cold Crucible Induction Melter (CCIM) technologies will be evaluated for HLW and LAW processing. Washington River Protection Solutions (WRPS), DOE's tank waste contractor, is developing and evaluating these systems in cooperation with EM-31, national and university laboratories, and corporate partners. A primary NGM program goal is to develop the systems (and associated flowsheets) to Technology Readiness Level 6 by 2016. Design and testing are being performed to optimize waste glass process envelopes with melter and balance of plant requirements. A structured decision analysis program will be utilized to assess the performance of the competing melter technologies. Criteria selected for the decision analysis program will include physical process operations, melter performance, system compatibility and other parameters.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluating cascaded and tunable phase change materials for enhanced thermal energy storage utilization and effectiveness in building envelopes

The incorporation of phase change materials (PCMs) in envelope is considered an effective thermal energy storage (TES) method for energy savings and load flexibility in buildings. However, an important limitation of PCMs is their fixed and narrow transition temperature range. Because the interior temperature setpoints are typically different in summer versus winter, and the exterior temperature varies substantially above and below the setpoints during the year, PCMs with a fixed transition temperature are utilized only during part of the year. In this paper, we provide an extensive numerical analysis of the performance of a lightweight building envelope containing three different types of PCMs: traditional single-layer PCM with a fixed transition temperature, novel cascaded two-layer PCM with different transition temperatures, and a "futuristic" tunable PCM whose transition temperature can be varied in-situ using external excitation. We compare their performances by evaluating the relationship between the PCM utilization and parameters such as latent heat, transition temperature range, PCM thickness, and PCM location. While traditional PCMs are mostly active during one season, properly designed cascaded and tunable PCMs can be active much longer, thereby allowing load shift and energy savings in both heating and cooling seasons. Under the operating conditions considered in this study, tunable PCMs performed best, providing the highest utilization (about 2 times the traditional PCMs) and enhanced effectiveness (up to 99% peak load reduction in cooling season and 34% peak load reduction in heating season) with the same amount of material as the traditional PCMs; however, cascaded PCMs can be a good alternative while tunable PCMs are unavailable.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗