Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “particulate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Assessing Uncertainties of a Geophysical Approach to Estimate Surface Fine Particulate Matter Distributions from Satellite-Observed Aerosol Optical Depth

Health impact analyses are increasingly tapping the broad spatial coverage of satellite aerosol optical depth (AOD) products to estimate human exposure to fine particulate matter (PM2.5). We use a forward geophysical approach to derive ground-level PM2.5 distributions from satellite AOD at 1 km2(exp) resolution for 2011 over the northeastern US by applying relationships between surface PM2.5 and column AOD (calculated offline from speciated mass distributions) from a regional air quality model (CMAQ; 12×12 km2(exp) horizontal resolution). Seasonal average satellite-derived PM2.5 reveals more spatial detail and best captures observed surface PM2.5 levels during summer. At the daily scale, however, satellite-derived PM2.5 is not only subject to measurement uncertainties from satellite instruments, but more importantly to uncertainties in the relationship between surface PM2.5 and column AOD. Using 11 ground-based AOD measurements within 10 km of surface PM2.5 monitors, we show that uncertainties in modeled PM2.5∕AOD can explain more than 70 % of the spatial and temporal variance in the total uncertainty in daily satellite-derived PM2.5 evaluated at PM2.5 monitors. This finding implies that a successful geophysical approach to deriving daily PM2.5 from satellite AOD requires model skill at capturing day-to-day variations in PM2.5∕AOD relationships. Overall, we estimate that uncertainties in the modeled PM2.5∕AOD lead to an error of 11 µg m−3(exp) in daily satellite-derived PM2.5, and uncertainties in satellite AOD lead to an error of 8 µg m−3(exp). Using multi-platform ground, airborne, and radiosonde measurements, we show that uncertainties of modeled PM2.5∕AOD are mainly driven by model uncertainties in aerosol column mass and speciation, while model representation of relative humidity and aerosol vertical profile shape contributes some systematic biases. The parameterization of aerosol optical properties, which determines the mass extinction efficiency, also contributes to random uncertainty, with the size distribution being the largest source of uncertainty and hygroscopicity of inorganic salt the second largest. Future efforts to reduce uncertainty in geophysical approaches to derive surface PM2.5 from satellite AOD would thus benefit from improving model representation of aerosol vertical distribution and aerosol optical properties, to narrow uncertainty in satellite-derived PM2.5.

aerosol optical depth↗

From Low-Cost Sensors to High-Quality Data: A Review of Challenges and Summary of Best Practices for Effectively Using Low-Cost Particulate Matter Mass Sensors

Low-cost sensors for particulate matter mass (PM) enable spatially dense, high temporal resolution measurements of air quality that traditional reference monitoring cannot. Low-cost PM sensors are especially beneficial in low and middle-income countries where few, if any, reference grade measurements exist and in areas where the concentration fields of air pollutants have significant spatial gradients. Unfortunately, low-cost PM sensors also come with a number of challenges that must be addressed if their data products are to be used for anything more than a qualitative characterization of air quality. The various PM sensors used in low-cost monitors are all subject to biases and calibration dependencies, corrections for which range from relatively straightforward(e.g. meteorology, age of sensor) to complex (e.g. aerosol source, composition, refractive index). The methods for correcting and calibrating these biases and dependencies that have been used in the literature likewise range from simple linear and quadratic models to complex machine learning algorithms. Here we review the needs and challenges when trying to get high-quality data from low-cost sensors. We also present a set of best practices to follow to obtain high-quality data from these low-cost sensors.

low-cost sensors↗

Spatial Variation of Fine Particulate Matter Levels in Nairobi Before and During the COVID-19 Curfew: Implications for Environmental Justice

The temporary decrease of fine particulate matter (PM(sub 2.5)) concentrations in many parts of the world due to the COVID-19 lockdown spurred discussions on urban air pollution and health. However there has been little focus on sub-Saharan Africa, as few African cities have air quality monitors and if they do, these data are often not publicly available. Spatial differentials of changes in PM(sub 2.5) concentrations as a result of COVID also remain largely unstudied. To address this gap, we use a serendipitous mobile air quality monitoring deployment of eight Sensirion SPS 30 sensors on motorbikes in the city of Nairobi starting on 16 March 2020, before a COVID-19 curfew was imposed on 25 March and continuing until 5 May 2020. We developed a random-forest model to estimate PM(sub 2.5) surfaces for the entire city of Nairobi before and during the COVID-19 curfew. The highest PM(sub 2.5) concentrations during both periods were observed in the poor neighborhoods of Kariobangi, Mathare, Umoja, and Dandora, located to the east of the city center. Changes in PM(sub 2.5) were heterogeneous over space. PM(sub 2.5) concentrations increased during the curfew in rapidly urbanizing, the lower-middle-class neighborhoods of Kahawa, Kasarani, and Ruaraka, likely because residents switched from LPG to biomass fuels due to loss of income. Our results indicate that COVID-19 and policies to address it may have exacerbated existing air pollution inequalities in the city of Nairobi. The quantitative results are preliminary, due to sampling limitations and measurement uncertainties, as the available data came exclusively from low-cost sensors. This research serves to highlight that spatial data that is essential for understanding structural inequalities reflected in uneven air pollution burdens and differential impacts of events like the COVID pandemic. With the help of carefully deployed low cost sensors with improved spatial sampling and at least one reference-quality monitor for calibration, we can collect data that is critical for developing targeted interventions that address environmental injustice in the African context.

Environmental justice↗

Analysis of microsize particulates

Unique methods for analyzing individual particles ranging in size from 0.01 to 1000 micrometers have been developed for investigation of nature of cosmic dust. Methods are applicable to particulate aerosols and contaminants characteristically encountered in studies of air pollution and in experiments designed to abate pollution.

Blanchard, M. B.↗

Exploratory development and services for preparing and examining ultrathin polished sections of lunar rocks and particulates, part 2

General principles and details of the actual procedure are presented for the preparator. Some background information is given on why certain lapping, polishing, and gluing procedures are needed. It is directed toward the innovative preparator who wishes to further refine procedures or to use some of his own techniques for some steps in the processing sequence. Specific details on the single procedure found to be most successful for lunar dense rocks, breccias, and particulates are outlined. A complete listing of equipment and supplies is appended.

Beauchamp, R. H.↗

Exploratory development and services for preparing and examining ultrathin polished sections of lunar rocks and particulates, part 1

Development of improved procedures is reported for three classes of lunar materials: dense rocks, breccias, and particulates. High quality ultrathin sections of these materials are obtained. Lists of equipment and supplies, procedures, photomicrographic documentation, and training are provided. Advantages of ultrathin polished sections for conventional and unconventional optical microscopy methods are described. Recommendations are provided for use of ultrathin sections in lunar rock studies, for further refinement of ultrathinning procedures, and for additional training efforts to establish a capability at the Manned Space Center. For Part 2, See N72-50754.

Beauchamp, R. H.↗