Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “outage analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Thermodynamic Cloud Phase Classifications Using Machine Learning at NSA and ANX

Vertically resolved thermodynamic cloud phase classifications are essential for studies of atmospheric cloud and precipitation processes. The Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) THERMOCLDPHASE Value-Added Product (VAP) uses a multi-sensor approach to classify thermodynamic cloud phase by combining lidar backscatter and depolarization, radar reflectivity, Doppler velocity, spectral width, microwave radiometer-derived liquid water path, and radiosonde temperature measurements. The measured voxels are classified as ice, snow, mixed-phase, liquid (cloud water), drizzle, rain, and liq_driz (liquid+drizzle). We use this product as the ground truth to train three machine learning (ML) models to predict the thermodynamic cloud phase from multi-sensor remote sensing measurements taken at the ARM North Slope of Alaska (NSA) observatory: a random forest (RF), a multilayer perceptron (MLP), and a convolutional neural network (CNN) with a U-Net architecture. Evaluations against the outputs of the THERMOCLDPHASE VAP with one year of data show that the CNN outperforms the other two models, achieving the highest test accuracy, F1-score, and mean Intersection over Union (IOU). Analysis of ML confidence scores shows ice, rain, and snow have higher confidence scores, followed by liquid, while mixed, drizzle, and liq_driz have lower scores. Feature importance analysis reveals that the mean Doppler velocity and vertically resolved temperature are the most influential datastreams for ML thermodynamic cloud phase predictions. The ML models’ generalization capacity is further evaluated by applying them at another Arctic ARM site in Norway using data taken during the ARM Cold-Air Outbreaks in the Marine Boundary Layer Experiment (COMBLE) field campaign. Finally, we evaluate the ML models’ response to simulated instrument outages and signal degradation.

54 ENVIRONMENTAL SCIENCES↗

High-Burnup BWR LOCA Burst Analysis Framework Development and Demonstration

Nuclear power currently contributes approximately 20% of total electricity generation in the United States and more than 10% globally. Given the increasing reliance on nuclear energy to achieve our nation’s goal of reaching net-zero carbon emissions by 2050, there is significant pressure on the existing nuclear industry to extend plant operational licenses and improve efficiency. This is crucial as the existing nuclear fleet serves as a vital bridge until new light water and advanced reactors can be developed and deployed, bolstering the supply of carbon-free energy to meet domestic demands. Operational costs primarily consist of plant operation and maintenance and fuel costs, influenced by materials and reactor core designs. These factors, coupled with heavily subsidized renewable energy markets, create a challenging economic environment for the existing light water reactor fleet, as well as for new build projects. To address these economic challenges, the nuclear industry has developed a strategic blueprint aimed at enhancing nuclear power’s economic sustainability. Past initiatives, such as efforts to eliminate fuel failures by 2010 and reduce operating costs by 30% before 2020, have laid the groundwork. Optimizing core design parameters, including burnup limits and enrichment levels, can lengthen cycles, reduce outages, reduce batch reload batch fractions and spent fuel storage requirements, and lower maintenance and operating expenses, thereby enhancing economic viability. In the United States, boiling water reactors (BWRs) comprise approximately one-third of the fleet, although much of the research and development focus has traditionally been on pressurized water reactors (PWRs). Advances in modeling and simulation, particularly through the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program, are crucial to the long-term viability of BWRs, just as they are for PWRs. A key research area of the high burnup/increased enriched fuel initiative is focused on addressing loss-of-coolant-accident (LOCA)-related issues. NEAMS has dedicated significant effort to enhancing tools to better support BWRs, with a current focus on showcasing the BWR framework for high-burnup LOCA analysis. This high-fidelity work will demonstrate a best estimate pin-by-pin high-burnup BWR LOCA analysis to assess full-core cladding rupture behavior. This modeling capability will help with better understanding and realistic evaluation of fuel fragmentation, relocation, and dispersal (FFRD) phenomena at BWRs, which then could be used to prevent FFRD at BWRs without penalizing operational parameters. In addition, the results of this work will help identify strategies to identify additional margins or to potentially limit cladding rupture through core design optimizations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Impact assessment of geomagnetic induced current neutral blocking devices with power electronics sources on distance relay for 230 kV transmission lines

Electrical grids increased the integration of power electronics sources onto transmission lines. In addition, recent reports show a significant rise in geomagnetic storms occurring in 2024. These geomagnetic storms can affect transmission lines by inducing electrical currents within them, potentially causing power outages due to overloaded power transformers. Geomagnetic induced current neutral blocking devices (GIC-NBDs) are capacitors on the ground of wye power transformers, to avoid damage caused by geomagnetic storms. The integration of distance relays and transmission lines with power electronics sources and GIC-NBDs needs to be studied to observe if GIC-NBDs and power electronics sources could adversely affect operation of the electrical grid. In this analysis, the effect of 2 MW power electronics sources and GIC-NBDs on distance relays is assessed for different 230 kV transmission line lengths in radial and nonradial power systems. The simulations measured the apparent impedances, with different electrical faults. Results for a typical 2,650 μF GIC-NBD application were presented on impedance plots, and the distance relay model operations were assessed. In conclusion, the tests for radial and nonradial power systems showed the behavior of the distance elements and source impedance ratios, assessing the effect of power electronics sources and GIC-NBDs on 230 kV transmission lines.

Distance relays↗

Physics-Based Feature Extraction from Bulk Time-Series PMU Datasets for Event Detection

In this work, two physics-based feature extraction techniques are developed for bulk time-series phasor measurement unit (PMU) datasets collected from the field to train the machine learning model for anomaly detection. Two approaches have been developed to extract useful features for different types of events. An admittance-based feature extraction technique is developed to detect events that involve line outages and system topology variations. The developed algorithm extracts the system equivalent admittance variation. Additionally, Fielder’s Theory is utilized to further reduce the potential computation burden by sectionalizing large-scale grids and datasets into smaller areas. Second, an oscillation-based feature extraction technique is developed to detect low-frequency oscillations in power grids. The dominant oscillation modes in the grids are extracted using energy-sorted Prony analysis. The extracted dominant oscillation modes by the developed work exhibit a high fitting resolution. Finally, the developed techniques have been validated using large-scale and real-world datasets.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Wildfire and power grid nexus in a changing climate

Global wildfire events have had increasingly severe impacts in recent years, particularly in the western USA, driven by extreme fire-weather conditions, fuel accumulation and multiple ignition sources. Wildfires sparked by power lines tend to be larger and more destructive, as they often occur during high winds, which accelerate the spread of fires. Moreover, efforts to contain wildfires frequently result in power outages, causing considerable economic disruption. Here, in this Review, we examine wildfire risks related to power-line-induced ignitions, infrastructure damage, climate-induced environmental impacts, grid operational risks, real-time grid management risks, vegetation management risks, and financial and funding risks in the context of a changing climate and their interdependence with power grid infrastructures. We then explore the resilience of power grids under wildfire threats, looking at risk analysis, prediction and mitigation strategies. The Review also shares practical insights and experiences in the USA to inform researchers, policymakers and industry professionals.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dispatch analysis of flexible power operation with multi-unit small modular reactors

The relevance of nuclear power plant flexible power operation (FPO) is rising due to increased penetration of variable renewables. Small Modular Reactors (SMRs) such as NuScale are envisaged to have multiple units on one site. This provides opportunities for coordinating FPO between units, but also introduces challenges as common services (e.g., refueling equipment) must be shared between units and fuel loadings may be standardized. It is therefore important to quantify whether FPO with SMRs is economically beneficial. Here, this paper quantifies the economics of FPO on different timescales to analyze refueling outages of such multi-unit SMRs. A 24-h price-taker profit maximization of SMR operation is first solved considering revenues from wholesale power and ancillary service (AS) markets. The results are then used to find the most profitable operation strategy over several years for multiple units at the site accounting for the physics and materials limits on NPP operation, including refueling outages. Results show a small but appreciable participation of nuclear into AS, contributing 4% of revenues. Due to the longer fuel cycle, over a decade of operation the units’ refueling outages drifted by 3 months, ultimately leading to refueling during summer.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

MPC4CLR (Model-Predictive-Control-for-Critical-Load-Restoration-in-Power-Distribution-Systems) [SWR-22-24]

Model predictive control (MPC) is a system or process control technique for making decisions under uncertainty via rolling look-ahead optimizations at each control step where only the current step decisions are applied, and the rest are discarded. In this work, we developed an MPC for a critical load restoration (CLR) in power distribution systems to recover system service (electricity delivery) following an extreme event-triggered substation outage. The method considers the problem of controlling distributed energy resources (DERs) of the distribution system with the objective of achieving maximum load pick up while satisfying distribution network flow and voltage constraints. A linearized optimal power flow (OPF) model is employed to represent the physics of the network. The problem formulation is augmented with a ramping (up) reserve product for the DERs to ensure improved and upward monotonic load restoration as time evolves. Simulation analysis and performance tests are performed using a modified IEEE 13-bus test feeder integrated with wind, solar, microturbine, and energy storage battery. The software is developed using various software packages in Julia and Python. The MPC model is implemented using the JuMP optimization language in Julia while the data analytics including renewable generation and load demand forecasts, running the MPC simulation and visualizations is performed in Python.

Eseye, Abinet Tesfaye↗

PowerModelsGAT-AI: Physics-Informed Graph Attention for Multi-System Power Flow With Continual Learning

Solving the alternating current power flow equations in real time is essential for secure grid operation, yet classical Newton–Raphson solvers can be slow under stressed conditions. Existing graph neural networks for power flow are typically trained on a single system and often degrade on different systems. We present PowerModelsGAT-AI, a physics-informed graph attention network that predicts bus voltages and generator injections. The model uses bus-type-aware masking to handle different bus types and balances multiple loss terms, including a power-mismatch penalty, using learned weights. We evaluate the model on 14 benchmark systems (4 to 6,470 buses) and train a unified model on 13 of these under contingency conditions with up to two branch outages, achieving an average normalized mean absolute error of 0.89% for voltage magnitudes and R 2 >0.99 for voltage angles. We also show continual learning: when adapting a base model to a new 1,354-bus system, standard fine-tuning causes severe forgetting with error increases exceeding 1000% on base systems, while our experience replay and elastic weight consolidation strategy keeps error increases below 2% and in some cases improves base-system performance. Interpretability analysis shows that learned attention weights correlate with physical branch parameters (susceptance: r=0.38 ; thermal limits: r=0.22 ), and feature importance analysis supports that the model captures established power flow relationships.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Large Scale Bilevel Optimization for N-K SCOPF Using Adversarial Robustness

Ensuring a secure dispatch against multiple simultaneous outages has long been desired to maintain grid security in the presence of severe events, such as extreme weather phenomena. Traditionally denoted as N-k security constrained optimal power flow (N-k SCOPF), this problem is intractable to solve due to its size being combinatorial in the number of simultaneous outages and due to the non-convex nature of the AC network constraints. This hinders the use of N-k SCOPF for operating realistic-scale systems. In this paper, we introduce a methodology to scalably solve an AC-feasible dispatch that improves security over k simultaneous outages. Our methodology poses N-k SCOPF as a bilevel optimization problem and solves it using an adversarial robustness approach. We develop new efficient methods to solve each level of the bilevel optimization by employing knowledge of the physics of the underlying system. This yields significant improvements in speed and convergence that enable us to address the N-k SCOPF problem at scale. We demonstrate the effectiveness of our method by conducting a comprehensive analysis of an N-3 SCOPF for a 500-bus network. Furthermore, we emphasize the ability of our physics-driven techniques to handle larger systems by successfully scaling up to 12,000 buses.

24 POWER TRANSMISSION AND DISTRIBUTION↗

WISP: Watching grid Infrastructure Stealthily through Proxies (Final Technical Report)

The complex interdependencies of cyber systems (sensors and communications), physical grids and associated electricity market operations make protecting electric power grids a significant challenge. The energy sector is constantly under new, targeted, advanced and dangerous cyber-attacks that have the potential to result in the loss of human life. These threats are further exacerbated by our need to modernize the grid. One focus of cyber security research in smart grids is the securing of the SCADA system through advanced intrusion detection systems (IDS) and bad data detection algorithms in state estimation. These methods either require full knowledge of the system topology and parameters or fail to understand the physical behaviors under attack. WISP (Watching grid Infrastructure Stealthily through Proxies) is designed to provide additional protection to the power grid using only publicly available data. In particular, WISP exploits the spatio-temporal nature of the real time locational marginal prices (LMPs), in conjunction with other information such as bids, weather, outages and load data to analyze anomalous power pricing behaviors and then correlate those observations to localize regions of interest and identify potential cyber events. WISP is non-intrusive as the tool is deployed as a service in the Cloud or on premise and provides reliable information to system operators for enhanced situational awareness, without impeding energy delivery functions. The WISP technology comprises three modules: the data-driven anomaly detection core, the vulnerability and risk analysis and the root cause analysis. The data-driven anomaly detection core performs the tasks of feature selection, anomaly detection and attack region localization. The vulnerability and risk analysis module provides system level information of the vulnerable variables and times, assisting the operators in selecting monitoring and protection nodes. The root cause analysis module takes the detection results and identifies potential operational conditions that contribute to the detected anomalies. In Phase I, we have demonstrated the feasibility and effectiveness of WISP. We developed a realistic electricity market simulator capable of generating normal and attack market data under various operational conditions. We developed a series of cyber-attack detection and analysis algorithms and evaluated them under multiple data sources. Finally, we integrated all modules into an end-to-end software, providing functions for data management, data analytics and visualization. Specifically, we have achieved: (i) real-time data acceptance from external utility interfaces with >99% acceptance rate; (ii) high performance anomaly detection algorithms with >98% detection accuracy and <0.1% false alarm rate; and (iii) ultra-low computing delay <50 milliseconds. Additionally, our team developed algorithms to identify the vulnerable variables in electricity market operations and root cause analysis functions to identify major contributors to the price spikes. These ancillary modules are necessary when deploying WISP in real world industry environment. In Phase II, we have demonstrated the effectiveness of WISP software on realistic largescale power systems. We performed red team testing for the Phase I WISP software and identified software vulnerabilities and implemented corresponding mitigation solutions. We adapted the electricity market simulator for the Texas synthetic 2000-bus system and generated datasets for the false data injection attacks. We created database and visualization interfaces for the Texas system and the ISO New England system. We performed software optimization in terms of operation efficiency, computing speed and detection accuracy. Finally, we tested the software on the Texas system and the ISO New England system and evaluated the detection performance. Overall, we achieved above 89% detection rate, below 3% false alarm rate and below 37 seconds of end-to-end detection delay.

24 POWER TRANSMISSION AND DISTRIBUTION↗

AGGREGATE: dAta-driven modelinG preservinG contRollable dEr for outaGe mAnagemenT and rEsiliency (Final Report)

The AGGREGATE project team successfully developed and validated various modules for outage management. Brief summaries of each module are provided to showcase their strength for outage management and restoration for a distribution system with a high penetration of connected distribution energy resources (DERs). In recent years, inverter-based DERs have been widely deployed in distribution system. A most of behind-the-meter (BTM) solar power generation is not visible to the utility. The data-driven DER and load estimation modules are using machine learning (ML) and artificial intelligence (AI) to manage this issue, which provides an opportunity for distribution system operators (DSOs) to operate systems and make decisions in real-time for a distribution system with a high penetration of DERs deployed. Also, the estimated DER and true load can be further leveraged in network aggregation and cold-load pick up estimation for reducing the computing complexity and providing for fast restoration. After load demand and DER power generations have been estimated, the information will support topology and state estimation (SE). The topology estimation module demonstrated the viability of mixed integer linear programming (MILP) formulation to estimate the most likely operational radial topology and outage sections using power flow measurements, historical/estimated load and DERs data and smart meter ping measurements. Formulation includes continuous (power flow, load and DERs data) and binary measurements (smart meter ping measurements) in a single formulation. Errors in continuous data and binary data are modeled as normal distribution and Bernoulli distribution, respectively. In the future distribution grid, the power injection from controllable DERs will be essential for efficient and resilient grid operation. However, determining the optimal DER injections and restoration actions is dependent on knowledge of the system states. State estimation (SE), already the cornerstone of transmission energy management systems, will become commonplace in distribution management systems as more measurements become available from deployment of automated metering infrastructure (AMI). Observability analysis is the first step in SE, as it determines the sufficiency of the available measurements for accurately estimating the current system states. A new type of pseudo-measurement called a Correlational Measurement (CM) is introduced in this module, to enhance the observability of the system to enable more accurate SE. CMs encapsulate knowledge of correlation between demand patterns for similar classes of loads as well as injection patterns for same-technology renewable DERs. During grid contingency scenarios, DERs have been traditionally disconnected, without any fault ride-through capabilities. However, with new regulations and better technology, it is feasible for these resources to contribute to the grid’s restoration after an adverse event and hence enhance resilience. The controllability module proposes a two-step restoration scheme for the power system restoration process by leveraging additional degrees of freedom in power electronics interfaced DERs for mitigating voltage problems. In a resilience mode without the utility system, the distribution grid relies on DERs to serve critical load. In such a severe event with multiple faults on the distribution feeders, actuation of various protective devices (PDs) divides the distribution system into electrical islands. The undetected actuated PDs due to fault current contributions from DERs can delay the restoration process, thereby reducing the system resilience. The Advanced Outage Management (AOM) and the Advanced Feeder Restoration (AFR) modules developed in this project provide improved system resilience with multiple DERs. AOM identifies the faulted sections and actuated PDs in a distribution system with DERs by incorporating smart meter data. The most credible outage scenario including fault locations, PD actuations, and fault indicator (FI) failures is identified by a set of binary integer linear programming incorporating hypotheses. The AFR module serves to restore a distribution system with available energy resources taking into consideration the availability of utility sources and DERs. By partitioning the system into islands, critical load will be served with the available generation resources within islands based on the solution of a MILP. When the utility systems become available, the optimal path will be determined by a spanning tree search algorithm that reconnects these islands back to substations and restores the remaining load. The transmission and distribution (T&D) co-simulation module was used to validate the effect of a control action performed on the distribution side assets as it propagates to the transmission side. This ensures that the control action performed results in a feasible operating point on both the transmission and the distribution system. In addition to validation, the team used the T&D co-simulation module to demonstrate how distribution system assets can be used to mitigate issues on the transmission system. Specifically, the team demonstrated that appropriate switching operations on the distribution side can alleviate the line overload condition on the transmission side without causing new operational constraint violations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Smart-DS: Synthetic Models for Advanced, Realistic Testing: Distribution Systems and Scenarios

The explosion of new ideas for distributed energy resources and advanced distribution grid algorithms faces a critical challenge: how can one effectively develop and evaluate these breakthrough technologies without an adequate set of power systems network, load, and resource data to test against? Today's open test systems, particularly for distribution systems, are tiny and incomplete; and though with enough effort, obtaining utility data under NDA can overcome scale challenges, the results can't be openly shared, preventing fair comparison. The Smart-DS project-led by NREL in partnership with MIT, Universidad Pontificia Comillas, CYME, and EDD-is working to overcome this gap by generating multiple large-scale, open, synthetic, distribution systems that are realistic but not real. These datasets go beyond a single medium voltage feeder (~1000 customers) to cover entire metropolitan areas and their surrounds with up to hundreds of feeders and millions of customers, complete with low voltage customer connections and high voltage sub-transmission. This scale allows adequate testing and analysis of not just local controls and advanced DERs, but also multiple substation interactions, optimized switching, full-scale distribution-OPF, and more. To accompany these datasets, the project is also building a rich set of scenario generation tools that can be used for distribution and transmission systems alike. This includes automated, spatially aware access to world-class, high-resolution solar, wind, and weather data: forward looking generation mixes: and highly configurable DER, load, climate, outage, control-scheme, and other scenarios. We will also highlight DiTTo, an exciting open-source, multi-way distribution dataset transformation tool for many-to-many format translation with scenario, merge/split, and many other manipulation capabilities.

DERs↗

Application of Mobile Energy Storage for Enhancing Power Grid Resilience: A Review

Natural disasters can lead to large-scale power outages, affecting critical infrastructure and causing social and economic damages. These events are exacerbated by climate change, which increases their frequency and magnitude. Improving power grid resilience can help mitigate the damages caused by these events. Mobile energy storage systems, classified as truck-mounted or towable battery storage systems, have recently been considered to enhance distribution grid resilience by providing localized support to critical loads during an outage. Compared to stationary batteries and other energy storage systems, their mobility provides operational flexibility to support geographically dispersed loads across an outage area. This paper provides a comprehensive and critical review of academic literature on mobile energy storage for power system resilience enhancement. As mobile energy storage is often coupled with mobile emergency generators or electric buses, those technologies are also considered in the review. Allocation of these resources for power grid resilience enhancement requires modeling of both the transportation system constraints and the power grid operational constraints. These aspects are discussed, along with a discussion on the cost–benefit analysis of mobile energy resources. The paper concludes by presenting research gaps, associated challenges, and potential future directions to address these challenges.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Material Selection and Sizing of a Thermoelectric Generator (TEG) for Power Generation in a Self-Powered Heating System

By employing the high temperature heat source to directly generate the electricity needed to power auxiliary systems in a natural gas furnace, boiler or hot water heater, a “self-powered” heating system can provide several benefits. Compared with a traditional furnace, boiler or hot water heater, when overall fuel utilization is kept constant, the self-powered system will have a higher primary energy efficiency, lower operating costs, and dramatically improved building safety and resilience during electric grid outages. Furthermore, a self-powered heating system only has a single utility connection – natural gas, without an electric connection – thus simplifying installation. A thermoelectric generator can be used for direct energy conversion of thermal energy to electricity with no moving parts, which offers a very simple means to provide power for the self-powered heating system, and the operation is without noise or vibration and can thus provide a very long system life. This paper provides an analysis focused on materials selection and the thermal power requirements for a thermoelectric generator (TEG) for use in a self-powered heating system. The dimensionless figure of merit for thermoelectric materials, zT, is used to estimate the optimal efficiency that can be achieved with a TEG to produce the electric power required in such an application. Comparisons of the predicted efficiency, the required heat transfer rate to the TEG and the heat transfer area needed for sustained operation under thermal conditions relevant to the self-powered heating application are made for several potential thermoelectric materials. This analysis was used to develop system requirements for a self-powered hot water heater using a TEG for electric power generation.

Laclair, Tim↗

AI-Enabled Robots for Automated Nondestructive Evaluation and Repair of Power Plant Boilers. Final Report

Boiler failure could cause loss of life and safety issues, cost hundreds of thousands of dollars in equipment repairs, property damage and production losses, and drive up the cost of electric power. Boiler maintenance is challenging and risky for inspectors working on scaffolding in confined hazardous spaces inside of a boiler and sometimes the space is hard to access. The operation is also time-consuming due to the large area of vertical structures for inspection and the tremendous effort needed for scaffolding. Recently, the use of robotics (e.g., drones and crawlers) in power plants for maintenance is growing rapidly. However, the existing robotics solutions show two notable technological gaps: no live repair capability, and no Artificial Intelligence (AI) for smart autonomy. The objective of this project is to develop an integrated autonomous robotic platform that is equipped with compact non-destructive evaluation (NDE) sensors to perform live inspection, operates onboard repair devices to perform live repair, and uses AI for intelligent data fusion and predictive analysis for automated and smart spatiotemporal inspection, analysis and repair of the furnace walls in coal-fired boilers. The approach to achieve the objective includes developing NDE sensors with signal processing techniques, designing and evaluating repair devices for robots based on fusion and solid-state technologies, and an autonomous robotic platform that can attach to and navigate on boiler furnace walls using magnetic drive tracks. The robot is also powered by AI to automate data gathering (e.g., 3D mapping and damage localization) and predictive analysis. This project has advanced the state-of-the-art by providing technological breakthroughs including compact NDE and repair tools for robots, AI capabilities for smart autonomy, and a robotic platform for automated boiler maintenance. This project has great potential to result in significant benefits including limiting or eliminating the need to send operators to assess difficult-to-access or hazardous areas, enabling automated live inspection and repair, avoiding time consuming scaffolding (especially for partial maintenance during unplanned outage), collecting comprehensive and well-organized data smartly, and avoiding or limiting the need for onsite or remote piloting technicians. The impacts can be tremendous in terms of the time and cost savings, reducing the risk for human operators, and increasing boiler reliability, usability, and efficiency. In addition, by developing the new technologies on the autonomous inspection and repair robot, by involving multiple undergraduate and graduate students working together with the faculty members on this project, and by generating knowledge and building up collaborations with industrial partners, this effort will significantly update the education capabilities, support long-term fundamental research, and maintain the leadership of Colorado School of Mines and Michigan State University in energy fields.

20 FOSSIL-FUELED POWER PLANTS↗

Powering the Blue Economy Foundational Research & Development Topics Reliability for Marine Energy Power Systems

Ocean observing platforms are deployed across the world’s oceans to collect meteorological and oceanographic data. Current technology makes use of solar panels and battery banks to provide power to these platforms, which can be challenging at high latitudes due to lack of solar insolation and cold temperatures. Marine renewable energy (MRE) generation offers a potential improvement in consistent power generation throughout the year for this use on ocean observation buoys. This report analyzes existing reliability of high latitude coastal weather buoys and tsunami detection buoys to determine performance standards that MRE generation sources must meet to become viable power sources for these remote systems. Using measurements recorded from the U.S. National Data Buoy Center’s coastal weather buoys and tsunami detection buoys, the analysis calculated the historic data availability – or the percentage of time a measurement is recorded – to evaluate the reliability of ocean observation buoys. The results show that coastal weather buoys operate at 74% data availability and the tsunami detection systems operate at an average 72% data availability. The results describe the total reliability of the system, including many different types of failures not associated with the power system such as mooring failures or equipment failures caused by extreme weather. Power system outages may only account for a small portion of the system failures. Reliability is an important design criterion for the power system of ocean observation platforms. Future power systems that would be designed for these buoys, such as an MRE generator, need to have a minimum reliability of 72% and 74% to meet the overall performance of the weather buoys and tsunami buoys, respectively. However, power system reliability likely needs to be much higher than overall system reliability, so that power system outages do not negatively impact the overall performance of the buoy.

42 ENGINEERING↗

A Data Exchange Interface for a Standards Based Data Integration Platform

The modern electrical grid is a complex and a data rich system, requiring several sub-systems to provide the capability and support needed to perform functions such as distributed energy resource management, outage management, and fault location and isolation, to name a few. There is a need to develop software solutions and platforms that provide an integrated infrastructure to allow interoperability between these subsystems, while leveraging the abundant data available from today’s grid. In this paper, we present the development and deployment of an application service to integrate GridAPPS-D which is an open source, standards-based software platform with SurvalentONE, a commonly used DNP3 based ADMS platform that allows operation, monitoring, analysis, restoration, and optimization of network operations. We present details of the integration architecture, including its implementation, and provide results from functional testing of the architecture on a 13 bus IEEE system. The results validate that the integration is successful and is able to provide a two-way exchange of communication and translation between different communication protocols.

Singh, Alka↗

Fitness For Service Assessment of a Corroded Heat Exchanger

Within the Fermi National Accelerator complex, there exist various water systems that support accelerator operations. One of these systems is extremely vital to the operation of the machine; that is the cooling system. The cooling system consists of nine relatively large heat exchangers that take untreated pond water and use it to cool the process fluid that further cools machine components. Over the 30 years these heat exchangers have been in operation, they have undergone significant material loss on the channels. This material loss, due to various forms of corrosion such as galvanic and microbiologically influenced corrosion (MIC) and possibly others, has deteriorated more than 80% of the nominal wall thickness of some of the exchangers and placed them in a questionable state. ASME FFS-1 (API 579) has been applied to address the condition of the heat exchangers due to their noncompliance with the governing code, BPVC Sec. VIII Div. 1. The assessments encompassed ASME FFS-1 parts 4: General Metal Loss and 9: Crack Like Flaw using level 1, 2, and 3 analysis techniques based on inspection data obtained by API 510 inspections. Level 1 and 2 assessments were deemed unfit for the corroded regions due to their location relative to a major structural discontinuity (channel to tube-sheet joint), so a level 3 analysis was conducted according to ASME Sec. VIII Div. 2 (design by analysis) rules for pressure vessels. Supplemental information included pond water tests to determine an accurate future corrosion allowance due to lacking inspection history. A leak before break (LBB) route was chosen to evaluate the possibility of leaking prior to the onset of failure. The analysis of one heat exchanger shows that the possibility the channel will develop a pinhole leak over 2.5 more years of operation should not be overlooked, but burst was unlikely from operation. The use of fracture mechanics show, that if a through-wall crack were to develop, it would not propagate further than the channel geometry and cause a leak not greater than 35 GPM. Using ASME Section XI Code Case N-705-1, allowing us to operate with a leak until the next outage given certain operating conditions and developing a leak mitigation procedure, this heat exchanger is deemed fit-for-service.

Humenik, Alex [Fermilab]↗