Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “outage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Probabilistic Resilience of DER Systems - A Simulation Assisted Optimization Approach

Energy systems resilience is becoming increasingly important as the frequency of major grid outages increases. In this work, we present a methodology to optimize a behind-the-meter distributed energy resource system to sustain a site's critical loads during a pre-defined outage period. With the fixed system design, we then propose an outage simulation approach to estimate the resilience potential of the DER system to sustain loads beyond the fixed outage period - a yearlong resilience performance analysis. We apply statistical analysis to assess the system's resilience performance over a broader parametric problem space on an hourly, monthly, and yearly basis. We demonstrate the impact of the pre-defined outage period on the resilience performance through a case study. Results show that the probability of surviving a random outage of a given duration changes from 20% to 95% when the outage is modeled for a weekday instead of a weekend for the given load-profile.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Oak Ridge National Laboratory EAGLE-I TM : Modeling Electric Utility County Customers for Situational Awareness

During natural hazard events (hurricanes, wildfires, earthquakes, etc.) and recent man-made events (e.g., cyber attacks), the exchange of near real-time, spatially refined data within the response community is critical. The EAGLE-I$^{TM}$ platform is one tool that facilitates this data for decision makers within the energy sector. While much information can be collected and integrated into the system directly, other pertinent data must be augmented by other derived data products to enhance the information and allow for a consistent evaluation of on-the-ground conditions. One such data set that requires the addition of other derived data is the electric utility customer outage data that is aggregated to the county level within the EAGLE-I application. Without a county customer data set, outages can only be compared on total counts, which gives greater importance to higher population outages. Including an electric utility customer data set at the county level allows for these outage counts to be converted to percent outages and brings a consistent classification of outages and equal importance to all outages. To achieve this, several available data sets were combined and spatial disaggregation techniques were employed to model customer estimates at the county scale. This paper presents the approach to produce this data for the United States and lessons learned from working with these disparate data sets. Data validation is provided, where possible, and limitations of the model and possible improvements are discussed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Designing an Alternate Mission Operations Control Room

The Huntsville Operations Support Center (HOSC) is a multi-project facility that is responsible for 24x7 real-time International Space Station (ISS) payload operations management, integration, and control and has the capability to support small satellite projects and will provide real-time support for SLS launches. The HOSC is a serviceoriented/ highly available operations center for ISS payloads-directly supporting science teams across the world responsible for the payloads. The HOSC is required to endure an annual 2-day power outage event for facility preventive maintenance and safety inspection of the core electro-mechanical systems. While complete system shut-downs are against the grain of a highly available sub-system, the entire facility must be powered down for a weekend for environmental and safety purposes. The consequence of this ground system outage is far reaching: any science performed on ISS during this outage weekend is lost. Engineering efforts were focused to maximize the ISS investment by engineering a suitable solution capable of continuing HOSC services while supporting safety requirements. The HOSC Power Outage Contingency (HPOC) System is a physically diversified compliment of systems capable of providing identified real-time services for the duration of a planned power outage condition from an alternate control room. HPOC was designed to maintain ISS payload operations for approximately three continuous days during planned HOSC power outages and support a local Payload Operations Team, International Partners, as well as remote users from the alternate control room located in another building. This paper presents the HPOC architecture and lessons learned during testing and the planned maiden operational commissioning. Additionally, this paper documents the necessity of an HPOC capability given the unplanned HOSC Facility power outage on April 27th, 2011, as a result of the tornado outbreak that damaged the electrical grid to such a degree that significantly inhibited the Tennessee Valley Authority's ability to transmit electricity throughout the North Alabama region.

Montgomery, Patty↗

Establishing nationwide power system vulnerability index across US counties using interpretable machine learning

Power outages have become increasingly frequent, intense, and prolonged in the US due to climate change, aging electrical grids, and rising energy demand. However, largely due to the absence of granular spatiotemporal outage data, we lack data-driven evidence and analytics-based metrics to quantify power system vulnerability. This limitation has hindered the ability to effectively evaluate and address vulnerability to power outages in US communities. Here, in this work, we collected ∼179 million power outage records at 15-min intervals across 3022 US contiguous counties (96.15 % of the area) from 2014 to 2023. We developed a power system vulnerability assessment framework based on three dimensions (intensity, frequency, and duration) and applied interpretable machine learning models (XGBoost and SHAP) to compute Power System Vulnerability Index (PSVI) at the county level. Our analysis reveals a consistent increase in power system vulnerability across the US counties over the past decade. We identified 318 counties across 45 states as hotspots for high power system vulnerability, particularly in the West Coast (California and Washington), the East Coast (Florida and the Northeast area), the Great Lakes megalopolis (Chicago-Detroit metropolitan areas), and the Gulf of Mexico (Texas). Our heterogeneity analysis indicates that urban counties and those located along regional transmission boundaries tend to exhibit significantly higher vulnerability. Our results highlight the significance of the proposed PSVI for evaluating the vulnerability of communities to power outages. The findings underscore the widespread and pervasive impact of power outages across the country and offer crucial insights to support infrastructure operators, policymakers, and emergency managers in formulating policies and programs aimed at enhancing the resilience of the US power infrastructure.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hybrid power plants: An effective way of decreasing loss-of-load expectation

Diversifying variable renewable resources by combining wind, solar photovoltaic, and battery assets in a hybrid power plant can increase renewable energy usage efficiency and improve system flexibility, particularly in distributed energy systems. However, the resilience impact of these systems, particularly outage mitigation, can be difficult to quantify due to uncertainty in resource, energy demand, and outage occurrence. Here, this study outlines a framework to quantify the incremental benefit of hybrid power plant assets for reducing loss-of-load expectation during random outage events. Hybrid power plant performance during outages (considering varying duration and severity) is simulated using a Monte Carlo methodology to reflect uncertainty associated with renewable resource, load demand, and outage timing. Results demonstrate the additional incremental value from increasingly hybrid designs, in which relative capacities of wind, solar photovoltaic, and storage assets contribute to lower loss-of-load expectation than the constituent technologies would alone. The value of added wind or solar capacity increases as the plant composition approaches an equal split. The value of added battery capacity depends on the outage duration and severity, but the first 50 MWh of added storage capacity is the most valuable for reducing the loss-of-load expectation for all plant designs.

14 SOLAR ENERGY↗

Integration of equitable resilience metrics into climate-informed electric utility planning processes: phase one

Working together, Sandia National Laboratories, Southern California Edison (SCE) - an Investor-Owned Utility (IOU) - and the California Public Utilities Commission (CPUC) are studying how electric utilities can use equity and resilience metrics to help inform the prioritization and sequencing of resilience-driven infrastructure investments. To this end, this project evaluated “Social Burden,” an equitable resilience metric which measures the potential impact of disruptions in access to non-electric critical services on people and estimates community resilience to these disruptions. The Social Burden was expanded to incorporate SCE’s existing equity metric and applied to evaluate the potential impacts from a range of climate-informed hypothetical outage scenarios developed under SCE’s 2022 Climate Adaptation Vulnerability Assessment. One baseline (“blue-sky”) state and eight different outage scenarios were evaluated to measure the potential impacts of the outages on non-electric infrastructure, critical services, and people. Key findings include: 1) the Social Burden framework is flexible enough to adapt to and build upon existing utility equity and/or resilience metrics, 2) Social Burden results highlight the high degree of non-electric service redundancy within the SCE service area with most (6/8) hypothetical outage scenarios predicted to increase people’s Social Burden by less than 10%; however, 3) access to critical services and people’s ability to obtain them is unequal and spatially clustered, meaning that there are some hypothetical outage scenarios (2/8) that will exert a higher toll on communities directly experiencing the outage as well as some nearby communities with pre-existing vulnerabilities. The report concludes with recommendations for potential use cases of the expanded Social Burden metric and identifies priority follow-on work. Potential use cases may include incorporating equity into IOU’s prioritization of climate resilience investments. Additionally, Social Burden analysis may provide additional data and insights to augment grid planning, potentially by identifying additional needs and/or prioritizing previously identified needs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Designing an Alternate Mission Operations Control Room

The Huntsville Operations Support Center (HOSC) is a multi-project facility that is responsible for 24x7 real-time International Space Station (ISS) payload operations management, integration, and control and has the capability to support small satellite projects and will provide real-time support for SLS launches. The HOSC is a service-oriented/ highly available operations center for ISS payloads-directly supporting science teams across the world responsible for the payloads. The HOSC is required to endure an annual 2-day power outage event for facility preventive maintenance and safety inspection of the core electro-mechanical systems. While complete system shut-downs are against the grain of a highly available sub-system, the entire facility must be powered down for a weekend for environmental and safety purposes. The consequence of this ground system outage is far reaching: any science performed on ISS during this outage weekend is lost. Engineering efforts were focused to maximize the ISS investment by engineering a suitable solution capable of continuing HOSC services while supporting safety requirements. The HOSC Power Outage Contingency (HPOC) System is a physically diversified compliment of systems capable of providing identified real-time services for the duration of a planned power outage condition from an alternate control room. HPOC was designed to maintain ISS payload operations for approximately three continuous days during planned HOSC power outages and support a local Payload Operations Team, International Partners, as well as remote users from the alternate control room located in another building.

Montgomery, Patty↗

Reliability of emergency and standby diesel generators: Impact on energy resiliency solutions

Emergency diesel generators are the most common form of backup power for critical loads when the grid fails and are most often deployed as stand-alone generators (<2000 kW) tied to individual buildings for hospitals, emergency services, military bases, ports, airports, industries, and commercial facilities. Understanding the finite reliability of emergency diesel generators during continuous operation is critical for energy planners, managers, and end-users. A new analysis of two large non-public emergency diesel generator operational data sets shows that commonly used reliability metrics are inadequate to predict the performance during a grid outage. Additional metrics addressing the likelihood of an emergency diesel generator to be available at the time an outage starts, successfully start and carry load, and constantly run for the duration of the outage are needed to predict the continuous run-time reliability of emergency diesel generators during a grid outage. This is the first analysis of the reliability of modern generators that follow standard maintenance protocols commonly used for backup power and these new metrics are shown to be dependent on the level of emergency diesel generator maintenance with values that can vary by more than an order of magnitude. Even using the new metrics for well-maintained emergency diesel generators, the analysis shows that the single emergency diesel generators configurations are only 80% likely to provide power for the duration of a two-week grid outage.

ENERGY PLANNING, POLICY, AND ECONOMY,POWER TRANSMI↗

Resilience Analytics for Interdependent Power and Water Distribution Systems

The occurrence of large-scale outages in power distribution systems (PDSs) caused, for instance, by extreme weather events has raised concerns on the cascading impact of the power outages on the resilience of other critical infrastructures, including water distribution systems (WDSs), whose healthy operation highly relies on the availability of power from PDSs. Here, this paper proposes an analytics model for quantifying the interdependence between the resilience of power and water distribution systems. The proposed model first performs spatio-temporal outage analysis on the PDS and WDS to determine the PDS power serving capability and the resulting cascading impact on the WDS water serving capability during the occurrence of disruptions. The resilience interdependence is then determined by a proposed set of six metrics calculated using the power and water serving capability profiles, which trace and quantify the cascading impacts of power outages in the operation of WDSs during the degradation and recovery stages. The proposed analytics model is implemented on the IEEE 33-bus power distribution system supplying power for pumping stations of a 15-node test WDS, considering multiple cases of water storage capacity, single and multiple outage scenarios, and availability of distributed generation. The numerical results demonstrate that the proposed metrics track the temporal and spatial interdependence between the resilience of power and water distribution systems, providing a mechanism to identify weak spots, and assess options to enhance the resilience of the critical water infrastructure.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Hybrid Power Plants for Energy Resilience: A Case Study

As renewable energy technologies are increasingly adopted, they pose an opportunity to improve the sustainability and resilience of distributed grids, especially when their design and operation is coordinated as a hybrid power plant. When included in hybrid power plants, distributed wind turbines in particular have the potential to enhance the resilience of distributed grids in areas with good wind resource, due to their ability to provide more consistent generation and ancillary services as compared to photo-voltaic (PV) solar panels. Despite this benefit, U.S. distributed wind adoption is lower than other comparable renewable energy technologies. In this study, we seek to demonstrate how hybrid power plants that include distributed wind turbines can contribute to distribution grid resilience by meeting loads (especially critical loads) more consistently, increasing reserve capacity, and providing value to customers during outages. To demonstrate these contributions, we integrate three separate frameworks and apply them to a case study in a rural electric cooperative in Iowa. Through this case study, we simulate and compare hybrid power plant design and operation during two hazard events: a tornado that causes a 48-hour distribution outage and a winter weather event that causes a 6-hour generation outage. The inclusion of a hybrid power plant that leverages 1) increased battery duration and 2) advanced forecasting and dispatch strategies that reserve capacity leading up to a hazard event best reduce lost loads as well as diesel consumption that would otherwise be used to meet those loads during short- and long-duration hazard events. Depending on the hybrid power plant capacity and operation, we find that the outage mitigation value of a hybrid power plant (measured in value to customers to avoid an outage and avoided lost revenues for the utility) is significant in both hazard events; adding wind, solar, and battery assets to the existing system adds about $50-$100M in avoided lost load and at least $4-$8k in utility value in the tornado hazard event, and $570k-$2.2M in avoided lost load and at least $220-$650 in utility value in the winter hazard scenario. In both the tornado and winter hazard scenarios, optimizing the operation of the hybrid system for resilience can lend similar value as increasing battery duration by 5 MWh for the lower capacity systems considered.

17 WIND ENERGY↗

Control of Behind-the-Meter Resources for Enhancing the Resilience of Residential Buildings

There is increased concern about the impacts of frequent power outages, caused primarily by extreme weather conditions. With increasing behind-the-meter resources such as solar photovoltaics (PV), battery energy storage, and controllable loads, these resources - if properly coordinated - can meet critical loads even during an outage. Resilience building controls can coordinate and operate these resources to enhance the resiliency of buildings supporting critical loads for longer duration. In this paper, we present two resilience building controls: rule-based control and model predictive control (MPC). We simulated various scenarios considering different locations, seasons, outage types, and times of outages to evaluate the performance of resilience controls. The results show that MPC-based control can enhance resilience up to 65% compared to rule-based control. Similarly, PV self-consumption and occupant thermal comfort both increase during outages with MPC-based control.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Techno-Economic Analysis of Data-Driven and Transactive Approaches for Resilience Enhancement

As extreme weather events lead to more frequent power outages, understanding and enhancing grid resilience is critical to mitigating economic losses and non-energy impacts from service disruptions. Here, this study introduces a novel techno-economic analysis framework for evaluating resilience enhancement mechanisms. The framework combines grid response modeling with a co-simulation approach and valuation methodology to provide a comprehensive assessment. We apply this framework to a realistic case study of the Texas grid during Winter Storm Uri in February 2021. Two advanced resilience strategies are analyzed: a data-driven rolling outage mechanism and a transactive energy (TE) based allocation scheme. The rolling outage scheme selectively serves customers based on real-time curtailment needs, while the TE scheme allows customers to trade energy allocations according to their preferences. Our findings show that both the rolling outage and TE schemes significantly outperform conventional methods (i.e. controlled outages) by reducing the amount of energy not supplied to customers by 41% and 64%, respectively. These approaches also enhance flexibility and customer satisfaction, while improving energy utilization for greater resilience. Additionally, they maintain thermal comfort about 3.5 times better and substantially lower customer risk exposure. A key contribution of this study is addressing both utility and customer perspectives while considering both energy and non-energy impacts. The techno-economic analysis indicates that implementing these resilience enhancement strategies would incur an additional 1.1Bto1.6B in utility costs but has the potential to avoid 17.3Bto18B of customer losses as compared to existing solutions, thereby underscoring the value of investing in advanced resilience, as it provides significant societal benefits to customers.

42 ENGINEERING↗

The L-CAPE Project at FNAL

The controls system at FNAL records data asynchronously from several thousand Linac devices at their respective cadences, ranging from 15Hz down to once per minute. In case of downtimes, current operations are mostly reactive, investigating the cause of an outage and labeling it after the fact. However, as one of the most upstream systems at the FNAL accelerator complex, the Linac’s foreknowledge of an impending downtime as well as its duration could prompt downstream systems to go into standby, potentially leading to energy savings. The goals of the Linac Condition Anomaly Prediction of Emergence (L-CAPE) project that started in late 2020 are (1) to apply data-analytic methods to improve the information that is available to operators in the control room, and (2) to use machine learning to automate the labeling of outage types as they occur and discover patterns in the data that could lead to the prediction of outages. We present an overview of the challenges in dealing with time-series data from 2000+ devices, our approach to developing an ML-based automated outage labeling system, and the status of augmenting operations by identifying the most likely devices predicting an outage.

43 PARTICLE ACCELERATORS↗

Estimates of the Economic Impacts of Long-Duration, Widespread Power Disruptions in Puerto Rico

A typical electricity customer in Puerto Rico experienced nearly 27 hours of power interruptions in 2023–with many customers experiencing extremely long duration outages during a single event (i.e., greater than one month). This project involved conducting state-of-the-art surveying to assess the direct costs of power outages occurring across Puerto Rico, developing customer-specific models to estimate future costs over varying outage durations, and comparing these estimates to FEMA’s Value of Unit Service for Electricity. We estimate that a territory-wide power outage may cost customers $\$1$, $\$5$ and $\$29$ billion during one-, 14-, and 30-day interruptions, respectively. However, these are lower-bound estimates because our study focused on direct economic costs and, by necessity, did not fully incorporate (1) indirect impacts to the economy; (2) costs to repair or replace damaged utility infrastructure; and (3) the broader societal consequences including increased morbidity- and mortality-related costs. The information contained in this study can be used to estimate the direct economic value of past or proposed investments in power system resilience. We conclude with a discussion of this study’s limitations and suggest additional research to improve stakeholder understanding of the impacts of power outages across Puerto Rico.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Data-driven Community-centered Resilient Assessment and Planning Toolkit for Nexus of Energy and Water (DCRAPT-NEW)

Urban areas, including Detroit and Pittsburgh, have suffered significant dual outages of the electrical and water infrastructure in the past decade due, in part, to the increasing number of extreme weather events. With increasing temperatures and rainfall intensity, these regions need to prepare for increasing extreme events through community-based energy and water resilience analysis, planning, and enhancement. This project developed a suite of open-source, open-access, community-centered, data-driven assessment and distributed energy resource (DER) and planning tools for energy and water resilience enhancement in urban areas. Through establishing a multi-level community awareness and engagement mechanism and a comprehensive collection of power outage and flooding data, an innovative group of community energy and water resilience assessment and planning tools have been developed for a wide range of users with differing and variable sets of data available to them. The developed tools include (1) DOE EAGLE-I data-driven, deep-learning assisted resilience assessment and DER planning tools at the county level with socioeconomic factors incorporated; (2) Utility annual power outage data-driven tools for long term resilience assessment and DER planning and 15-min power outage data-driven tools for short term resilience assessment and planning; (3) Detailed engineering tools for energy and water systems resilience assessment and planning when the system topology and component fragility curves are available; (4) Alternative Resiliency Metric Calculation that extracts and separates outage and restoration processes; and (5) Co-optimization tools that evaluate the resilience of the power and sewage system and allow users to conduct joint planning with energy and wastewater systems. The developed tools provide planners, decision-makers, and stakeholders with powerful capabilities to systematically evaluate system/community resilience and optimal and actionable guidance for enhancing resilience while prioritizing DER investments. The tools have been used and validated in Detroit and Pittsburgh and can be used in other areas of the nation. In addition, this project will (1) advance the knowledge and applications of machine-learning methods in analyzing and fusing different layers of information and generating meaningful data points such as generating rare weather events; (2) significantly improve the energy and water resilience of the identified communities in Detroit and Pittsburgh and prepare for more frequent and severe weather conditions; (3) help communities assess extreme weather event impacts and address short-term and long-term resilience-related issues The developed tools have been made public via GitHub and demonstrated to community stakeholders and utility companies via the two annual workshops and numerous community engagement meetings. The project outcomes are also disseminated through publications in various journals and conference proceedings, and presentations at top conferences.

13 HYDRO ENERGY↗

Supporting Disaster Assessment and Response with the VIIRS Day-Night Band

When meteorological or man‐made disasters occur, first responders often focus on impacts to the affected population and other human activities. Often, these disasters result in significant impacts to local infrastructure and power, resulting in widespread power outages. For minor events, these power outages are often short-lived, but major disasters often include long‐term outages that have a significant impact on wellness, safety, and recovery efforts within the affected areas. Staff at NASA's Short‐term Prediction Research and Transition (SPoRT) Center have been investigating the use of the VIIRS day‐night band for monitoring power outages that result from significant disasters, and developing techniques to identify damaged areas in near real‐time following events. In addition to immediate assessment, the VIIRS DNB can be used to monitor and assess ongoing recovery efforts. In this presentation, we will highlight previous applications of the VIIRS DNB following Superstorm Sandy in 2012, and other applications of the VIIRS DNB to more recent disaster events, including detection of outages following the Moore, Oklahoma tornado of May 2013 and the Chilean earthquake of April 2014. Examples of current products will be shown, along with future work and other goals for supporting disaster assessment and response with VIIRS capabilities.

Schultz, Lori A.↗

Optimizing design and dispatch of a resilient renewable energy microgrid for a South African hospital

Lack of access to reliable energy is a major concern for countries in sub-Saharan Africa. The national grids are unable to consistently satisfy demand. Therefore, users turn to distributed generation systems in the form of back-up generators. However, such systems are usually designed based on a rule of thumb. We employ a mixed-integer linear programming model that considers several options such as renewable energy, combined heat and power, and storage technologies, in addition to those on-site, to provide optimal design and dispatch decisions that minimize total cost. We apply this model to a case study for a hospital in South Africa, considering its need for reliable electricity in light of multiple outages that might occur over the course of a year, as well as its high heating and cooling loads. Our results show that optimal design and dispatch decisions for the distributed generation system address reliability challenges, regardless of the time at which they occur. And, these solutions yield millions of dollars in savings, suggesting that technologies such as the absorption chiller may be overlooked in typical designs; its integration can reduce demand charges even in the absence of combined heat and power. We show that total cost is most sensitive to changes in site electrical demand, followed by capital cost, fuel cost, photovoltaic production, and monthly demand charges; changes in fuel cost primarily affect system sizes of combined heat and power and the absorption chiller, while photovoltaic system size is more sensitive to the changes in capital and fuel costs, photovoltaic resource availability, and hourly electrical demand. Finally, an outage simulator demonstrates the ability of our optimized system to sustain with no interruptions in power five-hour outages with probability 1.0 and ten-hour outages with probability 0.65, significant improvements over 0.5 and 0.0, respectively, under a business-as-usual case.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Wildfire-Power Grid Interactions: Feedback, Impacts, Monitoring, Modeling, and Mitigation Strategies

Wildfires are increasingly interacting with electric power systems through a two-way hazard chain: fires damage grid assets and trigger cascading outages, while grid faults can ignite new fires under hot, dry, and windy conditions. This review synthesizes the state of knowledge across five domains: (i) physical impacts of flames, heat, and smoke on lines, towers, insulators, and substations; (ii) power-infrastructure-initiated ignitions via conductor clash, high-impedance faults, and corona discharge; (iii) widespread blackouts and disproportionate societal impacts; (iv) multi-scale monitoring spanning laboratory tests, in-situ and grid-integrated sensors, and Earth observation; (v) coupled modeling that links fire behavior with grid operations; and (vi) technological and strategic mitigation pathways spanning prevention, response, and recovery. We integrate these domains into a novel 'feedback-aware' socio-technical framework. Through a longitudinal analysis (2005-2025) of global incidents, we identify that while vegetation contact remains the most frequent ignition source, aging infrastructure failure has emerged as a critical driver of catastrophic 'mega-fires'. We further identify persistent gaps, including limited interoperability of high-frequency grid and environmental data, scarce real-time data assimilation, and under-developed equity metrics for outage management. We conclude by outlining a research agenda to (1) deploy interoperable sensing architectures, (2) advance feedback-coupled fire-grid simulations, and (3) evaluate mitigation portfolios through techno-economic and fairness lenses. Recognizing wildfire-grid interactions as coupled socio-technical systems is essential for protecting infrastructure and communities and for ensuring reliable, sustainable electricity in a changing world.

24 POWER TRANSMISSION AND DISTRIBUTION↗