Pulsed source for driving non-linear current dependent loads

A pulsed current source comprises a power source, a discharge capacitor, and an inductive element. The discharge capacitor is selectively coupled to either of the power source or the inductive element. When coupled to the power source, the discharge capacitor is charged. The inductive element can be connected to a load. The load can have a current-dependent impedance. When the discharge capacitor is coupled to the inductive element, the discharge capacitor discharges through the inductive element and the load. The discharge capacitor and the inductive element are configured so that the current through the load exhibits a substantially linear rise in a linear operational region. The inductive element is configured to saturate during discharge of the capacitor through the load, so that the saturation of the inductive element causes the current through the load to continue to rise in a substantially linear fashion.

Curtis, III, William C.↗

Image Characterization of Reactions Generated by an Aeroengine Micromixing Injector for Lean Direct Injection of Hydrogen and Hydrogen/Natural Gas Blend

An aeroengine micromixing injector, originally designed for lean direct injection of jet fuel, was adapted to work with hydrogen, natural gas, and any blend in between. The ultimate goal of the design was to achieve low NOx emissions when operated on pure hydrogen; to better characterize its performance, flame imaging diagnostics was implemented. Three types of cameras mounted parallel to the injector base and pointing towards the quartz combustor cylinder with the same angle were operated simultaneously: Nikon D90, Dynacolor FB-N9-U, and Phantom v7.1, to capture the visible spectrum, OH* chemiluminescence, and dynamic behavior of the flames, respectively. The current work also includes the overlapping of visible spectrum and OH* chemiluminescence, as an effort to qualitatively define the heat release over the flame area, i.e., UV over visible domain. Additionally, a z-type schlieren configuration was employed to reinforce the presence of some small-scale details occurring near the injector outlet ports. Using the airbox pressure drop, preheat temperature, fuel composition and flame temperature as the factors of study, a Box Behnken model was designed yielding into a 16-points matrix for the operability region, at atmospheric pressure. The main responses were extracted from the OH* images, because of its correlation with the flame heat release, these being the flame area and its average brightness, the heat release area and its center of gravity and leading edge. To assess the importance of the main factors and their interactions, an analysis of variance (ANOVA) was performed for each response, considering as significant each contributor with a p-value below 0.05. For these five responses it was found that all four main factors need to be included into the model (most of them because its own significance, others to ensure the model hierarchy), as well as some common interactions as the preheat and flame temperatures or pressure drop and fuel composition, and quadratic terms from fuel composition or flame temperature. Three of the five models presented R2 and coefficient of variance (C.V.) indicators around 0.97 and 5%, respectively; the leading edge ANOVA yielded into R2=0.78 and C.V.=18.88%; and the heat release area showed R2=0.91 and C.V.=24.13%. Lastly, the confinement ratio effect of the combustor over the flame structure was quantified, for three different conditions: the original 80 mm inner diameter and 200 mm length cylinder was compared against a shorter 150 mm tube (same inner diameter) and a narrower 47 mm inner diameter one (same 200 mm length). The length had a smaller effect than the inner diameter, even though both factors were not strong enough to make a significant deviation on most of the flame parameters: the difference was within the repeatability margin of error for the brightness, flame area, and center of gravity and leading edge of the heat release area.

Imaging diagnostics, flame characterization, OH* c↗

AMS National Reachback Capability - New Tools for Helping Emergency Responders

The Remote Sensing Laboratory’s (RSL) Aerial Measuring System (AMS) is one of the emergency response assets belonging to the U.S. Department of Energy (DOE) National Nuclear Security Administration (NNSA). The AMS is used to detect, measure, and track radioactive material before and during emergencies to locate sources or determine contamination levels. Since September 11, 2001, increasing numbers of local, state, and federal entities have developed aerial radiation detection capabilities. NNSA has recognized a need by these entities for an AMS Reachback Center that would provide training and assistance on all aspects of AMS. The Center will assist local, state, and federal agencies in establishing the skills, resources, and training needed for a successful AMS regional operation. Beginning in January 2008, and continuing through April 2008, a pilot program was created in collaboration between NNSA and the U.S. Department of Homeland Security’s Domestic Nuclear Detection Office (DNDO). The purpose of this collaboration was to provide aerial radiological surveillance and equipment technique training to local law enforcement offices in four major U.S. cities: Chicago, Washington DC, New York, and Los Angeles. The Mobile Aerial Radiological Surveillance (MARS) training curriculum was jointly developed by NNSA and DNDO headquarters and NNSA support teams. A total of 44 students participated in the training events held during this period. The positive reaction to this program has led to the establishment of the RSL as the headquarters for the National Aerial Measuring System Reachback (NAMSR) Center. The NAMSR Center will provide an AMS Home Team stand-by duty team for local, state, and federal agencies to discuss, plan, and analyze available data for aerial responses. An additional role of the Center will be to serve as the source of subject matter experts (SME) for the training of newly established aerial radiological monitoring assets. The purpose of this paper is to review the history, success, and future plans of the National AMS Reachback Center.

61 RADIATION PROTECTION AND DOSIMETRY↗

The Impacts on California of Expanded Regional Cooperation to Operate the Western Grid (Final Report)

Policy makers in California and other western states are exploring options for greater regional cooperation in managing the western power grid to better achieve public policy goals. This report, requested by the California State Assembly and commissioned by the California Independent System Operator (CAISO), reviews and summarizes recent proposals, studies, and papers addressing various modes of regional cooperation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multi-operator Production Cost Modeling

As contiguous power systems are often operated by several regional system operators, optimization models have traditionally been designed to generate optimal system-wide scheduling decisions. This report introduces an approach to reflect the existence of multiple system operators making scheduling decisions within an interconnected power system. The approach is explicitly designed to reflect each operator's limited knowledge about other regions when making scheduling decisions. Detailed analysis using a modified IEEE Reliability Test System reveals that the approach mimics real system operations by providing imperfect information to each operator about external operations and external constraints. The approach scales to a 78,000-bus model of the Eastern Interconnection, where a regression analysis provides quantitative insight into which constraints cause inefficiencies when improperly managed in a multi-operator simulation. Because the approach generates distinct regional scheduling problems, unit commitment and economic dispatch simulations can be applied to individual regions and solved in parallel, enabling production cost simulations at a previously intractable scale.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Emissions Impacts of Varied Energy Storage Operational Objectives Across Regions

The emissions consequences of smart grid technologies can be significant but are not always intuitive. This is particularly true in the implementation of energy storage (ES) systems that are being increasingly adopted to integrate more intermittent renewable generation, to reduce peak demand, and to participate in energy markets. Both the location of the ES system within the grid and the way it is operated will dictate its resulting impacts. The Grid Project Impact Quantification tool can provide insight into some of the emissions implications of hypothetical ES systems for a variety of operational objectives in diverse locations within the United States.

Barrett, Emily L.↗

Survey of U.S. Ancillary Services Markets

In addition to providing energy to end-consumers, power system operators are also responsible for ensuring system reliability. To this end, power markets maintain an array of ancillary services to ensure that it is always possible to balance the supply and demand for energy in real-time. A subset of these ancillary services are commonly procured through market-based mechanisms: namely, Regulation, Spinning, and Non-spinning Reserves. Regulation Reserves are maintained to respond to supply/demand imbalances over short time frames, typically on the order of several seconds to one minute. Resources that provide Regulation Reserves adjust their generation or load levels in response to automatic generation control (AGC) signals provided by the system operator. Contingency reserves are maintained to provide additional generation capacity in the event that load increases substantially or supply side resources reduce their output or are taken offline. The reserves are typically segmented into two categories, 1) Spinning or Synchronized Reserves that are provided by generation units that are actively generating and have the ability to increase or decrease their output, 2) Non-spinning or Non-synchronized Reserves that are provided by generation resources that are not actively generating, but are able to start up and provide generation within a specified timeframe. Contingency reserves typically have response times on the order of ten to 30 minutes and can also be provided by demand-side resources that are capable of reducing their load. There are seven distinct power markets in the United States, each operated by a Regional Transmission Operator (RTO) or Independent System Operator (ISO) that operates the transmission system in its territory, operates markets for energy and ancillary services, and maintains system reliability. Each power market offers its own set of ancillary services, and precise definitions, requirements, and market mechanisms differ between markets. Despite the differences between markets, both in terms of services offered and system requirements, some broad trends generally apply. Regulation Reserves typically have the highest market prices, followed by Spinning Reserves and Non-spinning Reserves. Prices for Regulation Reserves have been the highest in the PJM market, since it opened in October 2012. This is partially because PJM experienced large price spikes during the period of extreme weather conditions in early 2014. ERCOT has traditionally had the highest prices for Spinning Reserves (called Responsive Reserves in ERCOT), including several periods of sustained high prices between 2010 and 2012. This can be explained in part by the relatively high penetration of variable wind resources and a similarly high requirement relative to peak load. ERCOT has also traditionally had the highest price for Non-spinning Reserves, followed by the NYISO East region. Both have experienced several periods of prolonged high prices since their inception, an occurrence that has not been regularly seen in other markets. In ISO-NE and PJM for example, the market clearing price for Non-spinning Reserves is typically $0/MWh more than 95% of the time. Market volume (in terms of the average amount of capacity of each service that is provided to a system) typically follows the reverse order of prices, as systems maintain the most Non-spinning Reserves capacity followed by Spinning Reserves and Regulation Reserves. PJM generally has the largest market for Regulation Reserves both in terms of capacity. The size of most Regulation Reserves markets in terms of capacity stay relatively constant year-to-year, as this is dictated largely by system requirements. PJM also generally has the largest Spinning Reserves market in terms of capacity. SPP, MISO, ISO-NE and SPP (beginning in 2014) all have Spinning Reserve markets with similar average capacity levels. When combined, the markets for Non-spinning and Operating reserves in ISO-NE have a comparable capacity to the market for Primary Reserves 1 in PJM. SPP, MISO, and CAISO all have smaller markets for their respective Non-spinning Reserves products that are roughly the same size as each other in terms of capacity.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Proactive Operations and Investment Planning via Stochastic Optimization to Enhance Power Systems Extreme Weather Resilience

We present novel stochastic optimization models to improve power systems resilience to extreme weather events. We consider proactive redispatch, transmission line hardening, and transmission line capacity increases as alternatives for mitigating expected load shed due to extreme weather. Our model is based on linearized or "DC" optimal power flow, similar to models in widespread use by independent system operators (ISOs) and regional transmission operators (RTOs). Our computational experiments indicate that proactive redispatch alone can reduce the expected load shed by as much as 25% relative to standard economic dispatch. This resiliency enhancement strategy requires no capital investments and is implementable by ISOs and RTOs solely through operational adjustments. We additionally demonstrate that transmission line hardening and increases in transmission capacity can, in limited quantities, be effective strategies to further enhance power grid resiliency, although at significant capital investment cost. We perform a cross validation analysis to demonstrate the robustness of proposed recommendations. Our proposed model can be augmented to incorporate a variety of other operational and investment resilience strategies, or combination of such strategies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Measurement of distributed strain and temperature based on higher order and higher mode Bragg conditions

A Bragg grating sensor for measuring distributed strain and temperature at the same time comprises an optical fiber having a single mode operating wavelength region and below a cutoff wavelength of the fiber having a multimode operating wavelength region. A saturated, higher order Bragg grating having first and second order Bragg conditions is fabricated in the optical fiber. The first order of Bragg resonance wavelength of the Bragg grating is within the single mode operating wavelength region of the optical fiber and the second order of Bragg resonance wavelength is below the cutoff wavelength of the fiber within the multimode operating wavelength region. The reflectivities of the saturated Bragg grating at the first and second order Bragg conditions are less than two orders of magnitude of one another. In use, the first and second order Bragg conditions are simultaneously created in the sensor at the respective wavelengths and a signal from the sensor is demodulated with respect to each of the wavelengths corresponding to the first and second order Bragg conditions. Two Bragg conditions have different responsivities to strain and temperature, thus allowing two equations for axial strain and temperature to be found in terms of the measure shifts in the primary and second order Bragg wavelengths. This system of equations can be solved for strain and temperature.

Sirkis, James S.↗

Nimbus 4 IRIS spectra in the 750-1250 wavelengths/cm atmospheric window region

Present operational schemes for infrared remote sounding measurements of surface temperature use the 899 wavelengths/cm atmospheric window region. Spectra from the Nimbus 4 IRIS in the 750 to 1250 wavelengths/cm region are analyzed. Comparison of the actual surface temperature and the observed brightness temperature at 10 wavelengths/cm resolution shows that the clearest windows were at 936 and 960 wavelengths/cm. Although there is a small amount of CO2 absorption in these regions, this is compensated for by a decrease in water vapor continuum absorption. Atmospheric absorption was 0.5 K less than experienced by the 899 wavelengths/cm window.

Kunde, V. G.↗

A Concept for Flexible Operations and Optimized Traffic into Metroplex Regions

A "Flexible Flight Operations" concept for airport metroplexes was studied. A flexible flight is one whose destination airport is not assigned until a threshold is reached near the arrival area at which time the runway which reduces overall delay is assigned. The concept seeks to increase throughput by exploiting flexibility. The quantification of best-case benefits from the concept was pursued to establish whether concept research is warranted. Findings indicate that indeed the concept has potential for significant reductions in delay (and cost due to delay) in the N90 (NY/NJ) and SCT (Southern California) metroplexes. Delay reductions of nearly 26% are possible in N90 when 30% of the commercial airline flights are flexible (smartly selected by their low probability of connecting passengers); nearly 40% delay reduction is found when 50% of the flights are flexible. In the SCT metroplex, delay reductions estimates are greater. Greater reductions result at SCT since it is less constrained currently than N90, providing "more room" to take advantage of flexibility. Using the flexible operations concept for on-demand/air taxi and General Aviation flights were found to be beneficial at NY/NJ, indicating the flexible operations concepts may be useful to wide variety of users..

DeLaurentis, Daniel↗

Evolving Competitive Markets in SAPP: Leveraging Competitive Wholesale Electricity Markets to Drive Renewable Generation Capacity in the Southern African Power Pool (SAPP)

The SADC region has significant natural resource potential to increase renewable energy generation, improve electricity reliability, and support economic development. This research finds an apparent lack of confidence from electricity infrastructure investors in SAPP wholesale electricity markets, which increases risk perception and lowers the likelihood of capital deployment. With respect to free market fundamentals, competitive market obstacles and renewable energy development obstacles are characterized. Stakeholders identified the top obstacles to well-functioning competitive markets as insufficient transmission infrastructure for interconnection and regional movement of electricity, dominance of national single-buyer markets, and lack of or weak nation-state regulatory frameworks. Stakeholders prioritized the top three obstacles for renewable energy development as a lack of viable commercial arrangements for variable renewable energy (VRE) balancing, lack of functional and consistent nation-level regulations, and higher project costs related to reliance on imported equipment. With respect to potential solution options, stakeholders prioritized the development of new cost allocation and finance methods to facilitate new transmission expansion, training to educate new or potential new market entrants on SAPP processes, as well as modeling and analysis of regional SAPP participation benefits disaggregated to the nation-state level. From these perspectives, this research identified strategy options for consideration including transitioning SAPP to a regional transmission operator (RTO) for operation and planning of cross-border transmission facilities and market administration, shifting operations of SAPP member transmission systems to Independent System Operators (ISOs), establishing a regional regulatory authority and enhancing market data transparency. Implementing these reforms is expected to be challenging, but not insurmountable, given the domestic political, legal, and jurisdictional complexities of the SADC region.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗