Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “operating conditions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Universal correlation for falling film evaporation on a horizontal plain tube

Falling film evaporators are widely used in many industrial sectors, such as desalination, refrigeration & air-conditioning, and chemical processes. The heat transfer correlations suitable for wider operating conditions and various refrigerants are useful for designing falling film evaporators. Although many researchers developed the correlation for their own experimental data, there is a limited universal correlation for falling film evaporators. In addition, the dry-out effects were not considered in the available universal correlations. Here, therefore, this study proposes a new correlation for falling film evaporation on a single horizontal plain tube, which includes nucleate boiling, film evaporation, and dry-out effects. The proposed correlation covers a wider range of operating conditions (Heat flux is of 2.5–168kWm -2 , and film Reynolds number is up to 3500), various refrigerants (R134a, R245fa, R1234ze(E), R123, R32, R410A, R290, and R600a), and the large number of experimental data (1101 data in total). The proposed correlation is validated against the available standard correlation with regard to mean absolute deviation (MAD) and R 2 values. The MAD of the new correlation is about 10%, respectively, which is the lowest among other correlations. Similarly, the R 2 showed a value of 0.92, which is the highest compared to the existing correlations. A simplified correlation is also proposed.

42 ENGINEERING↗

Assessing Fuel Cycle Options for Elysium Molten Chloride Salt Fast Reactor from Spent Nuclear Fuel, Plutonium, and Depleted Uranium (Final CRADA Report)

Argonne National Laboratory performed calculations in order to determine the viability of various mode of operation and operating conditions for the reactor designed by Elysium Industry. The reactor description, operating conditions, startup fuel composition, and other relevant information were provided by Elysium to Argonne. The tools currently available at Argonne were used to perform the calculations and provide an assessment for the various cases agreed upon. The results were shared with Elysium.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Liquid Piston with Spray Cooling Near-Isothermal Compressor

The goal of this project was to prototype and characterize the performance of a liquid-piston spray-cooled gas compressor. The working principle of the compressor enables optimized high-efficiency operation over a very wide range of operating conditions, unlike conventional compressors that are optimized for a narrow range of operating conditions. The compressor technology is suitable for many applications, such as gas pipeline transport, gas storage, and commercial and residential heat pumps. Both physical testing and computational fluid dynamics (CFD) modeling of the processes using the Oak Ridge National Laboratory high-performance computing center were completed. The experimental and CFD studies focused on a near-isothermal liquid-piston compressor (LPC) that uses propylene glycol to compress CO 2 . The first prototype demonstrated isothermal operation during several sequentially executed cycles of CO 2 compression and raised the temperature of the compressed CO 2 by only 2 K, compared with approximately 6 K when the gas was compressed non-isothermally. Isothermal operation was demonstrated at CO 2 flow rates of up to 2 L/min. The second prototype was designed with two compression chambers to allow continuous flow of high-pressure CO 2 . However, the design of the valve train to direct flow between the compression chambers was not sufficient to allow demonstration of CO 2 compression. Numerical simulations of the LPC in which the compression chamber was filled with propylene glycol injected from the bottom inlet were performed using large eddy simulation (LES) with the wall-adapting local eddy-viscosity subgrid-scale model coupled with the multiphase volume of fluid (VOF) model to simulate the transient interface between gas and liquid and to capture the heat and mass transfers within the compression chamber. In this effort, the effects of boundary conditions applied to the LES-VOF calculations (i.e., no wall, an adiabatic wall, and a wall with a heat flux subscribed) on the overall pressure and temperature of the CO 2 gas as well as the transient evolution of flow and heat transfer within the compression chamber were investigated and are discussed in this report. The LES calculation with no wall showed no dynamical flow patterns, and the volume-averaged temperature of CO 2 increased from 305 to 392.7 K, whereas LES calculations with a constant wall temperature or a wall heat flux had similar increases of CO 2 temperatures. The results of the LES simulation using a wall heat flux showed different stages in the compression process and revealed dynamical formation and interaction of CO 2 gas layers and circulation flow patterns within the chamber that contributed to the overall heat transfer between the solid wall, gas, and liquid surface in the compressor. Though an industrial partnership for commercializing the compressor was not secured, the technology was attractive for an industrial partner to use in two research proposals in response to US Department of Energy funding opportunity announcements.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hanford Waste Treatment Plant LAB Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Waste Treatment Plant laboratory (LAB) facility stack monitor locations were qualified using scale model stacks to mitigate the risk of identifying that sampling locations do not meet the qualification criteria on the full-scale stack. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack, and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAB stacks were performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing, determines the range of conditions for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. A practical range for the full-scale stack qualification uses the average DV through 6 DV from the scale model tests to compute the corresponding flow rates. Table S1 lists the operating flow rates along with the average and maximum qualified stack flow rates for each of the LAB facility stacks. For each stack, the operating flow is below the maximum qualified stack flow, which means that the scale model test results are acceptable for stack qualification. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be ≤20°. Second, the velocity uniformity at the full-scale stack must be ≤20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack tests at the LAB facility. Flow angle results were primarily less than 10°, except for the LB-C2 Fan A results, which were an average of 13.7°; all flow angle results were within the ≤20° criterion. The velocity uniformity results for each test condition averaged between 1.5 and 4.1% COV, which were all within the range of the target percent coefficient of variation values from the scale model tests. Based on these stack verification test results, the three LAB filtered exhaust stack sampling locations meet the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes single-fan as well as dual-fan operations for LB-C2, each of the dual-fan operating conditions for LB-S1, and each single-fan operating condition for LB-S2. Further changes to the system configuration or operating conditions that are outside the bounds described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Waste Treatment Plant LAB Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Waste Treatment Plant laboratory (LAB) facility stack monitor locations were qualified using scale model stacks to mitigate the risk of identifying that sampling locations do not meet the qualification criteria on the full-scale stack. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAB stacks were performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing determines the range of conditions for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. Based on these DV values, the corresponding stack flow rates for each of the LAB stacks are 625 to 47,237 scfm for LB-C2, 1,704 to 103,131 scfm for LB-S1, and 467 to 18,088 scfm for LB-S2. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be =20°. Second, the velocity uniformity at the full-scale stack must be =20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack tests at the LAB facility. Flow angle results were primarily less than 10 degrees, except for the LB-C2 Fan A results, which were an average of 17.6 degrees; all flow angle results were within the =20° criterion. The velocity uniformity results for each test condition averaged between 1.5 and 3.5% COV, which were all within the range of the target %COV values from the scale model tests. Based on these stack verification test results, the three LAB filtered exhaust stack sampling locations meet the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes single-fan as well as dual-fan operations for LB-C2, each of the dual-fan operating conditions for LB-S1, and each single-fan operating condition for LB-S2. Further changes to the system configuration or operating conditions that are outside the bounds described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Gear Test Assembly - Experimental Testing and Analysis of Gears and Bearings - FY2026

The Gear Test Assembly (GTA) is an experimental test apparatus built and installed in the Mechanisms and Engineering Test Loop (METL) at Argonne National Laboratory (ANL). While designed to accommodate a variety of components intended for use in advanced compact in-vessel transfer machine, the focus of GTA been the testing of large radial spur gears. The performance of the components used in GTA motivates the choices made in the design, components, and material choices for the forthcoming METL test articles; the Gripper Test Assembly (GrTA), and the Bearing Test Assembly (BTA). To date, GTA has completed nine experimental testing campaigns and achieved over 21 million revolutions under prototypic sodium fast reactor loads and operating conditions. This report provides an overview and results for the two most recent experiments Campaign #8 and Campaign #9. `Campaign #8 was the first campaign to make use of a set of nickel alloy radial spur gears, made from Hastelloy C-22HS, and combined with heat-treated tapered roller bearings. The bearings and torque profile used allowed Campaign #8 to be directly compared with Campaign #1 where Inconel 718 gears were used instead. Campaign #8 attained 1,058,880 shaft revolutions within 23% of the 1,314,855 revolutions achieved in Campaign #1. These results demonstrate that the heat-treated tapered roller bearings show consistent increased lifetimes, approximately three times longer than for non heat-treated taper rollers, and that the particular material of the gear does not play a substantial role in performance. Similar to Campaign #7 where bearing failure resulted in fragmentation and transport of bearing material into the gear teeth led to tooth damage in the Inconel gears, a similar process led to the damage of the Hastelloy gears. Subsequent NDE analysis showed that the damage was only limited to the tooth surface and does not extend into the gear interiors. Based on the NDE reports, the Hastelloy gears can be reconditioned and put back into service for future campaigns as was done for the Inconel gears. Reconditioned Inconel 718 gears damaged in Campaign #7 were returned to service in Campaign #9 and paired with non heat-treated tapered roller bearings. In Campaign #9 a novel set of operating conditions were implemented whereby the gears and bearings were cycled between hot, submerged refueling conditions where fuel handling operations occurred and cold, dry, and inert conditions where the sodium was drained and the vessel was allowed to cool simulating long, ex-vessel storage of the fuel handling machine. A total of eight of these operating cycles were achieved before a bearing failure occurred after the accumulation of 475,692 shaft revolutions were achieved. During Campaign #9, one of the drive motors was damaged and over the course of a 240 day standby period, the entire GTA drive system was upgraded from a 480VAC system to a 240VAC system that provided the opportunity to consolidate wall-space in the METL facility and provide more space for additional test articles being installed in the coming year. The over 475,000 shaft revolutions achieved in Campaign #9 eclipses the previous record for lifetime of non heat-treated tapered roller bearings held by Campaign #3 of 392,000 shaft revolutions. Further analysis and future campaigns hope to shed light on the cause of this approximately 17% increase in lifetime.

42 ENGINEERING↗

Scaling up carboxylic acid production from cheese whey and brewery wastewater via methane-arrested anaerobic digestion

In a circular economy, organic waste streams are valuable resources for sustainably producing chemicals and fuels. This study investigates a new methane-arrested anaerobic digestion (MAAD) process that converts high-strength cheese whey and brewery wastewater into carboxylic acids. The process was developed and optimized under various bench-scale semi-continuous (fed-batch) operating conditions (e.g., retention time, organic loading rate, pH, and feed/harvest frequency). The MAAD responses to various control-failure scenarios were also systematically investigated. The highest total acid productivity was 26g/(L liq ·d) with a substrate conversion of 0.79g COD digested /g COD fed at a hydraulic retention time (HRT) of approximately 2 d in a 14-L digester. The most stable conditions for digester operation (HRT 3 d at pH 6.0 and 40°C) were selected for process scale-up to 100gal (~380 L). Semi-continuous, pilot-scale MAAD successfully produced a total acid concentration of 40.6+/-1.1 g/L with 8.1% acetic acid, 45.1% butyric acid, and 44.5% lactic acid. The links between wastewater characteristics, operation mode, digester scale, and microbial community structure were statistically analyzed. The results show genera Sporolactobacillus and Clostridium positively correlate with butyric acid production (Pearson correlation coefficient>0.5). Moreover, four kinetic models were developed and fit to batch MAAD experimental datasets (R 2 >95%) and were successfully applied to predict the total acid production in both bench-and pilot-scale semi-continuous MAADs. In conclusion, this study shows MAAD has the potential for industrial-scale applications and is a robust platform to valorize low- or negative-value waste streams into high-value bioproducts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Performance of sweeping gas membrane distillation for treating produced water: Modeling and experiments

Membrane distillation (MD) has shown promise for desalination of produced water (PW), but there are very few studies reported on the performance of MD with real PW and the characteristics of the fouling and scaling in MD. Among different MD configurations, sweeping gas MD (SGMD) is the least studied configuration. Here we report the application of SGMD for treating high-salinity PW (123 g L -1 ). The SGMD operating conditions were first carefully optimized through pure water MD experiments by varying operating conditions. The flux evaluation was accompanied by a detailed Aspen Custom Modeler simulation based on the electrolyte-NRTL thermodynamic model to better understand the heat and mass transfer in the feed and permeate channel. Supported by experiments, modeling results confirmed the partial condensation of the vapor in the permeate channel. Furthermore, it was concluded that the saturation of the sweeping gas is controlling the overall mass transfer through the membrane. Selected membranes and optimized conditions were then used to conduct short-term and long-term performance tests with PW. In long-term MD test, the concentration of the PW increased by a factor of two (50% water recovery), while the membrane exhibited small flux decline. Elemental analysis showed that strontium and sodium were the major scalant compounds.

42 ENGINEERING↗

Adaptive critic design-based reinforcement learning approach in controlling virtual inertia-based grid-connected inverters

In this report, an adaptive critic design (ACD) approach is proposed to control the phase and voltage of a grid-connected virtual synchronous generator (VSG). The penetration of fast responding inertia-less power converters significantly affect the stability of the power system, especially weak systems such as micro grids. The concept of virtual inertia addresses this concern by virtually emulating the behavior of a synchronous generator. However, the conventional VSG is designed based on two conditions: (i) fixed operating point and (ii) inductive grid connections. The performance of VSGs in low-voltage semi-resistive microgrids is far from optimal. To overcome the aforementioned concerns, a heuristic dynamic programing (HDP) approach is proposed to optimally control grid-connected VSGs. The neural-network-based inherence of the HDP enables the proposed technique to adapt to any impedance angle. The HDP controller includes two subnetworks: (i) the action network that controls the system optimally and (ii) the critic network, which evaluates the effectiveness of the action network. The simulation and experimental results are provided to evaluate the effectiveness of the proposed technique. As shown, the HDP-based approach illustrates a better performance in comparison with the conventional PI-based VSG in various operating conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dynamic Modelling and Performance Evaluation of a Chemisorption Heat Pump for Cold Climate

Space heating is a significant contributor to the energy consumption in residential buildings, especially in cold climates where electric-driven heat pumps lose the advantage of high efficiency and conventional gas-combustion furnaces have limited efficiency. Chemical adsorption (chemisorption) heat pumps (CSHP) have the potential for producing heating with high energy efficiency under cold operating conditions. A CSHP operates intermittently between desorption and adsorption modes, and their performance is affected by system design and transient system control. This study developed a dynamic model and used it to evaluate the daily system performance under different designs and controls, particularly the buffer tank size and the controlled minimum heating power. The simulation results revealed the effects of these parameters on the system performance and helped identify the optimal design and control for the highest coefficient of performance and heating capacity.

Yang, Zhiyao↗

Rejection of low-molecular weight neutral organics is highly sensitive to reverse osmosis system design and operation

A computational model was developed to investigate the significance of system design and operating conditions on the rejection of neutral, low-MW organics by reverse osmosis for potable reuse. Here, the model demonstrated that the decrease in local rejection as net driving pressure decreases is substantially greater for moderately rejected compounds than for highly rejected compounds. At recovery values less than 70%, the local permeate concentration can exceed the pressure vessel feed concentration for moderately rejected compounds. System-level rejection of moderately rejected compounds is likewise substantially more sensitive to operating conditions than highly rejected compounds. The findings highlight a drawback of relying on rejection results from bench-scale testing that operates at low recovery, which invariably has higher rejection than full-scale systems operating at similar pressure. The analysis demonstrates a trade-off in which the low-pressure, high-recovery operation desired for potable reuse systems can be detrimental to the removal of low-MW neutral organics. The removal of low-MW neutral organics can be improved if organics rejection is explicitly evaluated during the design process.

42 ENGINEERING↗

In Operando Angle‐Resolved Photoemission Spectroscopy with Nanoscale Spatial Resolution: Spatial Mapping of the Electronic Structure of Twisted Bilayer Graphene

To pinpoint the electronic and structural mechanisms that affect intrinsic and extrinsic performance limits of 2D material devices, it is of critical importance to resolve the electronic properties on the mesoscopic length scale of such devices under operating conditions. Herein, angle‐resolved photoemission spectroscopy with nanoscale spatial resolution (nanoARPES) is used to map the quasiparticle electronic structure of a twisted bilayer graphene device. The dispersion and linewidth of the Dirac cones associated with top and bottom graphene layers are determined as a function of spatial position on the device under both static and operating conditions. The analysis reveals that microscopic rotational domains in the two graphene layers establish a range of twist angles from 9.8° to 12.7°. Application of current and electrostatic gating lead to strong electric fields with peak strengths of 0.75 V/μm at the rotational domain boundaries in the device. These proof‐of‐principle results demonstrate the potential of nanoARPES to link mesoscale structural variations with electronic states in operating device conditions and to disentangle such extrinsic factors from the intrinsic quasiparticle dispersion.

Majchrzak, Paulina↗

Coupling of CTF and TRANSFORM using the Functional Mockup Interface

An in-memory coupling between the sub-channel thermal hydraulics code COBRA-TF (CTF), which is included in the Virtual Environment for Reactor Applications (VERA), and the systems code Transient Simulation Framework of Reconfigurable Models (TRANSFORM) was developed in this work. Data exchange is accomplished by using the Functional Mock-Up Interface (FMI), an open standard for coupling dynamic systems models together. The FMI-based coupling necessitated the development of a novel FORTRAN wrapper for communicating with Functional Mock-Up Units. This wrapper will facilitate future FMI-based code couplings with other FORTRAN-based programs. CTF-TRANSFORM is exercised on a simplified Molten Salt Reactor Experiment (MSRE) model in steady-state and transient configurations. The coupled CTF-TRANSFORM model is shown to predict core temperature deltas similar to those available in historical MSRE operational data and is shown to be robust to fast power transients.The coupling paves the way to performing sensitivity and design studies impossible with VERA/CTF alone, in which secondary and tertiary loop operating conditions and design parameters may be perturbed and their impact on the core operating conditions studied.

97 MATHEMATICS AND COMPUTING↗

Produced Water Desalination via Pervaporative Distillation

Herein, we report on the performance of a hybrid organic-ceramic hydrophilic pervaporation membrane applied in a vacuum membrane distillation operating mode to desalinate laboratory prepared saline waters and a hypersaline water modeled after a real oil and gas produced water. The rational for performing “pervaporative distillation” is that highly contaminated waters like produced water, reverse osmosis concentrates and industrial have high potential to foul and scale membranes, and for traditional porous membrane distillation membranes they can suffer pore-wetting and complete salt passage. In most of these processes, the hard to treat feed water is commonly softened and filtered prior to a desalination process. This study evaluates pervaporative distillation performance treating: (1) NaCl solutions from 10 to 240 g/L at crossflow Reynolds numbers from 300 to 4800 and feed-temperatures from 60 to 85 °C and (2) a real produced water composition chemically softened to reduce its high-scale forming mineral content. The pervaporative distillation process proved highly-effective at desalting all feed streams, consistently delivering <10 mg/L of dissolved solids in product water under all operating condition tested with reasonably high permeate fluxes (up to 23 LMH) at optimized operating conditions.

54 ENVIRONMENTAL SCIENCES↗

Computationally efficient evaluation of optimum homogeneous charge compression ignition operating range with accelerated multizone engine cycle simulation

The very intensive calculations necessary to define a performance map requiring evaluation of over a hundred individual operating points can be efficiently conducted with accelerated multizone for engine cycle simulation, leading to a definition of regions of acceptable and optimum homogeneous charge compression ignition operation. Accelerated multizone for engine cycle simulation has the virtue of enabling accurate evaluation of many operating conditions based on thermal stratification data from a single fluid mechanics run at motored conditions. This is possible because thermal stratification is more sensitive to engine geometry than to operating conditions. In this article, accuracy of accelerated multizone for engine cycle simulation is demonstrated by comparison with experimental data for iso-octane homogeneous charge compression ignition operation over a broad range of lean equivalence ratios (0.14–0.28). The validated accelerated multizone for engine cycle simulation model is then applied to generating a performance map for an engine controlled by appropriately adjusting equivalence ratio and internal exhaust gas recirculation. Regions of acceptable and optimum combustion are identified. It is finally demonstrated that while indicated mean effective pressure remains low for optimum homogeneous charge compression ignition operation (1–4 bar), this is sufficient for a large fraction of typical driving in light-duty vehicles. Much driving including idle can therefore be done in homogeneous charge compression ignition mode at high efficiency and low (essentially zero) NOx and particulate matter emissions.

30 DIRECT ENERGY CONVERSION↗

Performance Evaluation of Drain Water Heat Recovery Exchangers for Heat Pump Water Heaters

Water heating constitutes approximately 18% of energy consumption and is the second largest energy expenses in United States homes. Heat pump water heaters (HPWHs) are energy efficient technologies with lower carbon footprints as compared to conventional water heating technologies, such as gas and electrical resistance heaters. The performance of water-source HPWHs can be improved by recovering heat from blackwater using drain heat recovery heat exchangers. Depending on water draw patterns of single family and multifamily residences, the operation and heat transfer performance of these heat exchangers are highly transient. This paper examines the thermo-hydraulic performance of a drain heat recovery heat exchanger during its transient and steady-state operations. The heat recovery performance of the exchanger was evaluated at different inlet temperatures and flow rates ranging from 9°C to 36°C and 0.03 kg/s to 0.28 kg/s, respectively. The obtained effectiveness varies from 45%–85% depending on the operating conditions. The test facility, steady-state and transient experimental procedures are reported in detail. Further, the effect of operating conditions on the effectiveness is discussed. The experimental approach and results of the study will provide insights into the transient operation of drain recovery heat exchangers as well as, guide sizing for various steady state conditions.

Krishnan, Easwaran↗

Advanced Multiscale Microscopy Characterization of High Burnup LWR UO 2 Before and After LOCA Testing

Previous microscopy work within the campaign has observed increased porosity coupled with subgrain formation in the mid-radial region of the fuel. However, examinations of high burnup fuel taken from multiple reactors with different operating conditions have shown that this structure can move radially inward depending on the fuel operating conditions. It is currently theorized that inter- and intragranular fission gas bubble nucleation is precursory to the grain subdivision observed in the mid-radial and central regions of the fuel. Characterization of samples after loss-of-coolant accident (LOCA) testing has revealed that these restructured regions with a high density of bubbles and subgrains pulverize during the transient test. It appears that the increase in fission gas bubbles coupled with grain subdivision renders the fuel mechanically weaker during a LOCA transient and thus susceptible to fuel fragmentation relocation and dispersal (FFRD). Work this past fiscal year has prioritized understanding this behavior by using advanced microscopy to investigate fission gas behavior in the as-irradiated and post-LOCA state. Additional work has been performed to verify the theory described above by analyzing multiple post-LOCA optical micrographs and comparing that to as-irradiated microstructural data. This document reports progress in the post-irradiation characterization of high burnup nuclear fuel with emphasis on the restructured fuel regions, particularly how microstructural features influence FFRD and fission gas release behavior in LOCA conditions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Ducted Fuel Injection versus Conventional Diesel Combustion: An Operating-Parameter Sensitivity Study Conducted in an Optical Engine with a Four-Orifice Fuel Injector

Ducted fuel injection (DFI) has been shown to attenuate engine-out soot emissions from diesel engines. The concept is to inject fuel through a small tube within the combustion chamber to enable lower equivalence ratios at the autoignition zone, relative to conventional diesel combustion. Previous experiments have demonstrated that DFI enables significant soot attenuation relative to conventional diesel combustion for a small set of operating conditions at relatively low engine loads. This is the first study to compare DFI to conventional diesel combustion over a wide range of operating conditions and at higher loads (up to 8.5 bar gross indicated mean effective pressure) with a four-orifice fuel injector. This study compares DFI to conventional diesel combustion through sweeps of intakeoxygen mole fraction (XO 2 ), injection duration, intake pressure, start of combustion (SOC) timing, fuel-injection pressure, and intake temperature. DFI is shown to curtail engine-out soot emissions at all tested conditions. Under certain conditions, DFI can attenuate engine-out soot by over a factor of 100. In addition to producing significantly lower engine-out soot emissions, DFI enables the engine to be operated at low-NO x conditions that are not feasible with conventional diesel combustion due to high soot emissions.

42 ENGINEERING↗