Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “office”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Experimentally-Derived Bidirectional Reflectance Distribution Function Data in Support of the Orbital Debris Program Office

The NASA Orbital Debris Program Office (ODPO) has used various optical assets to acquire photometric data of Earth-orbiting objects to define the orbital debris environment. To better characterize and model optical data acquired from ground-based telescopes, the Optical Measurements Center (OMC) at NASA Johnson Space Center emulates illumination conditions seen in space by using equipment and techniques that parallel telescopic observations and source-target-sensor orientations. One of the OMC goals is to improve the size calculation used for optical data by developing an optical-based Size Estimation Model. The current size estimation requires applying a Lambertian phase function, a set albedo value, and range to the observed magnitude. The first step to improving the sampled brightness of laboratory targets is to remove aspect-angle dependencies. Then, the volume of possible object viewing angles is sampled at 21 combinations of azimuth and zenith angles for each solar phase angle. Finally, the acquired images are input into an image processing program that generates approximations for the object’s Bidirectional Reflectance Distribution Function (BRDF) and phase function. The BRDF is a radiometric concept that identifies an object’s material composition by matching a BRDF approximated with photometric data collected by ground-based telescopes with a BRDF generated experimentally from a known object in the laboratory. This paper discusses the validation of experimental BRDF and phase function approximations produced in the OMC and how the findings will be incorporated into ODPO models. A Lambertian sphere is imaged and the subsequent experimental functions are scrutinized to confirm that they correspond to an object that has an isotropic luminance. With the image processing algorithm validated, test objects with varying optical properties are then imaged to confirm that the produced photometric functions are both unique and repeatable. Once the validation is complete, the OMC will be used to evaluate a subset of fragments from a hypervelocity impact test of a mock-up satellite and assess the appropriate phase function and size estimates using BRDF measurements for a large volume of targets composed of various shapes, sizes, and materials.

Orbital Debris Program Office (ODPO)↗

Simulation and power quality analysis of a Loose-Coupled bipolar DC microgrid in an office building

With distributed generation and battery storage technologies thriving in microgrids, the use of direct current (DC) microgrids in the building sector offers multiple advantages in energy efficiency and power quality compared with alternating current (AC) systems. This study developed a new concept of a loose-coupled bipolar DC building power system. In this work, the concept was used to design a real-world office building in Shenzhen, China. A power system model was developed to study the stability and control of the DC power system and to verify DC power quality. The design and modeling of the DC power control system is discussed in detail. The study developed a few common fault scenarios in DC building microgrids that were simulated in the MATLAB-Simulink environment to validate the design of a loose-coupled bipolar DC system. The results indicate that the proposed loose-coupled bipolar DC system schema, when implemented with proper control algorithms, can achieve good fault-tolerant performance with reliable power quality, even during disruptive system events.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field demonstration and implementation analysis of model predictive control in an office HVAC system

Model Predictive Control (MPC) is a promising technique to address growing needs for heating, ventilation, and air-conditioning (HVAC) systems to operate more efficiently and with greater flexibility. However, due to a number of factors, including the required implementation expertise, lack of high quality data, and a risk-adverse industry, MPC has yet to gain widespread adoption. While many previous studies have shown the advantages of MPC, few analyzed the implementation effort and associated practical challenges. In addition, previous work has developed an open-source, Modelica-based tool-chain that automatically generates optimal control, parameter estimation, and state estimation problems aimed at facilitating MPC implementation. Therefore, this study demonstrates usage of this tool-chain to implement MPC in a real office building, discusses practical challenges of implementing MPC, and estimates the implementation effort associated with various tasks in order to inform the development of future workflows and serve as an initial benchmark for their impact on reducing implementation effort. This study finds that the implemented MPC saves approximately 40% of HVAC energy over the existing control during a two-month trial period and that tasks related to data collection and controller deployment activities can each require as much effort as model generation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Deep reinforcement learning control for co-optimizing energy consumption, thermal comfort, and indoor air quality in an office building

With the recent demand for decarbonization and energy efficiency, advanced HVAC control using Deep Reinforcement Learning (DRL) becomes a promising solution. Due to its flexible structures, DRL has been successful in energy reduction for many HVAC systems. However, only a few researches applied DRL agents to manage the entire central HVAC system and control multiple components in both the water loop and the air loop, owing to its complex system structures. Moreover, those researches have not extended their applications by incorporating the indoor air quality, especially both CO2 and PM2.5concentrations, on top of energy saving and thermal comfort, as achieving those objectives simultaneously can cause multiple control conflicts. What's more, DRL agents are usually trained on the simulation environment before deployment, so another challenge is to develop an accurate but relatively simple simulator. Therefore, we propose a DRL algorithm for a central HVAC system to co-optimize energy consumption, thermal comfort, indoor CO2 level, and indoor PM2.5 level in an office building. To train the controller, we also developed a hybrid simulator that decoupled the complex system into multiple simulation models, which are calibrated separately using laboratory test data. The hybrid simulator combined the dynamics of the HVAC system, the building envelope, as well as moisture, CO2, and particulate matter transfer. Three control algorithms (rule-based, MPC, and DRL) are developed, and their performances are evaluated on the hybrid simulator environment with a realistic scenario (i.e., with stochastic noises). The test results showed that, the DRL controller can save 21.4 % of energy compared to a rule-based controller, and has improved thermal comfort, reduced indoor CO2 concentration. The MPC controller showed an 18.6 % energy saving compared to the DRL controller, mainly due to savings from comfort and indoor air quality boundary violations caused by unmeasured disturbances, and it also highlights computational challenges in real-time control due to non-linear optimization. Finally, we provide the practical considerations for designing and implementing the DRL and MPC controllers based on their respective pros and cons.

Guo, Fangzhou↗

Investigation of HVAC operation strategies for office buildings during COVID-19 pandemic

To minimize the indoor transmission of contaminants, such as the virus that can lead to COVID-19, buildings must provide the best indoor air quality possible. Improving indoor air quality can be achieved through the building's HVAC system to decrease any concentration of indoor contaminants by dilution and/or by source removal. However, doing so has practical downsides on the HVAC operation that are not always quantified in the literature. This paper develops a temporal simulation capability that is used to investigate the indoor virus concentration and operational cost of an HVAC system for two mitigation strategies: (1) supplying 100% outdoor air into the building and (2) using different HVAC filters, including MERV 10, MERV 13, and HEPA filters. These strategies are applied to a hypothetical medium office building consisting of five occupied zones and located in a cold and dry climate. We modeled the building using the Modelica Buildings library and developed new models for HVAC filtration and virus transmission to evaluate COVID-19 scenarios. We show that the ASHRAE-recommended MERV 13 filtration reduces the average virus concentration by about 10% when compared to MERV 10 filtration, with an increase in site energy consumption of about 3%. In contrast, the use of 100% outdoor air reduces the average indoor concentration by about an additional 1% compared to MERV 13 filtration, but significantly increases heating energy consumption. Use of HEPA filtration increases the average indoor concentration and energy consumption compared to MERV 13 filtration due to the high resistance of the HEPA filter.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Tradeoffs among indoor air quality, financial costs, and CO 2 emissions for HVAC operation strategies to mitigate indoor virus in U.S. office buildings

Adapting building operation during the COVID-19 pandemic to improve indoor air quality (IAQ) while ensuring sustainable solutions in terms of costs and CO 2 emissions is challenging and limited in literature. Our previous study investigated different HVAC operation strategies, including increased filtration using MERV 10, MERV 13, or HEPA filters, as well as supplying 100% outdoor air into buildings for a system initially sized for MERV 10 filtration. This paper significantly extends that research by systematically analyzing the potential financial and environmental impact for different locations in the U.S. The previous medium office building system model is improved to account for operation in different climates. New evaluation metrics are created to consider the comprehensive impact of improving IAQ on costs and CO 2 emissions, using dynamic emission factors for electricity generation depending on the location. HVAC operation strategies are studied in five different locations across the United States, with distinct climates and electricity sources. In four of the five locations, MERV 13 filtration offers the best improvement in IAQ per increase in costs and emissions relative to MERV 10. The exception is the mildest climate of San Diego, where use of 100% outdoor air provides the best IAQ with a limited increase in costs and emissions. Finally, a system not sized for HEPA filtration can lead to increased costs and emissions without much improvement in IAQ.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The economic impacts of carbon emission trading scheme on building retrofits: A case study with U.S. medium office buildings

As a popular emission reduction tool, the carbon emission trading scheme (ETS) can potentially add an economic incentive for building owners to retrofit buildings in addition to the cost savings in energy. However, the additional economic benefits of building retrofits brought by ETS has not been quantitively investigated yet. Here, in order to fill this gap, this study proposed a systematic economic evaluation method to investigate the economic impacts of ETS on building retrofits. The reduction of the payback period and the increase of the return on investment are adopted as evaluation metrics. Using medium office buildings as an example, this study predicted the economic impacts of ETS on building retrofits at four locations in the U.S., and three different carbon prices were investigated. The results show that carbon prices have significant economic impacts on building retrofits. With the relatively low forecasted time-variant carbon prices (around 10 USD per ton), the economic impacts of ETS on building retrofits are small. When carbon prices increase, the impacts of ETS would be up to 25% for 50 USD per ton (current prices in European Union) and 51% for 100 USD per ton. Furthermore, locations with more fossil energy have higher relative changes in the payback period and ROI but are more sensitive to carbon prices.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Comprehensive Analysis of Model Parameter Uncertainty Influence on Evaluation of HVAC Operation to Mitigate Indoor Virus: A Case Study for an Office Building in a Cold and Dry Climate

Simulation-based studies of HVAC operation to mitigate indoor virus have been conducted to understand tradeoffs between indoor air quality (IAQ) and energy consumption. However, the influence of model parameter uncertainty in these studies has not been systematically quantified, which is critical when providing guidance to building operators. To address this gap, we identify 20 model parameters for a typical medium office building system in a cold and dry climate that can influence IAQ and energy consumption for indoor virus scenarios. Next, the distributions of the parameter values are estimated from literature and a set of simulation samples for three representative days is generated that simultaneously sample all of the parameters from their distributions. Two HVAC virus mitigation strategies are studied: increased filtration using MERV 13 filters and increased ventilation, via supply of 100% outdoor air into buildings. The model parameter uncertainty leads to significant variability in the results, particularly for the IAQ because of the highly uncertain virus generation rate. Use of 100% outdoor air can be beneficial for some uncertain scenarios on the hot day, but shows less IAQ improvement and/or significant energy increases on the other days. The virus removal efficiency and pressure drop of the HVAC filter, fan efficiency, and internal heat gain are the most important parameters to determining the tradeoffs of the two strategies. Our results demonstrate how this model parameter uncertainty analysis methodology can provide practical guidance to building operators.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

How Do Electricity Pricing Programs Impact the Selection of Energy Efficiency Measures? - A Case Study with U.S. Medium Office Buildings

Building owners usually select energy efficiency measures (EEMs) by referring to return on investment (ROI). Current studies tend to apply static energy price to estimate ROI. However, more and more buildings are adopting dynamic electricity pricing programs. To understand how electricity pricing programs impact the selection of EEMs, this paper presents an analysis of the ROIs of EEMs under different pricing programs using U.S. medium office buildings as an example. Eight EEMs in four typical cities are selected as case studies. Considering five electricity pricing programs scenarios (one static program and four dynamic programs), EEMs are selected based on their ROIs. The main findings are: (1) The ROIs of EEMs change under different pricing programs. (2) In Honolulu, Buffalo, and Denver, replacing interior fixtures with higher-efficiency fixtures has a significantly higher ROI than the rest EEMs under all five pricing programs. However, the ROI of this EEM in Honolulu ranges from 28% to 47% for different pricing programs. (3) Similarly, in Fairbanks, replace heating coil with higher-efficiency coil produce higher ROI than the rest under all five pricing programs. (4) For other EEMs, their ROI rankings vary according to electricity pricing programs.

demand response↗

Sequence-to-sequence neural networks for short-term electrical load forecasting in commercial office buildings

The U.S. power grid is transforming to become smarter, cleaner, and more effi- cient. This is leading to the addition of significant distributed variable renew- able generation. Due to the variable nature of renewable generation, the short- and long-term supply-demand imbalances are less predictable, and conventional approaches to mitigating the imbalance will not be efficient or cost-effective. To address this challenge, transactive control technologies have been proposed which balance energy generation and consumption with market activity and in- frastructural limitations. Transactive control requires the ability of individual end-use loads to express flexibility as a function of a transactive signal (e.g., price). Empirical gray- and black-box models have been widely used to express flexibility, and although these approaches are generally easy to construct and simple to use, they do not capture the non-linear behavior that some end-use loads represent . Machine learning approaches have been proposed to address this limitation. Although deep learning approaches for forecasting end-use loads have been explored, certain aspects of the application of deep models to load forecasting are not well understood. These aspects include how much training data is required, and how models should be structured and trained. To that end, this work explores how to approach applying deep recurrent neural networks to short-term electrical load forecasting with a case study of four commercial office buildings. We identify data requirements for training accurate models of whole building electricity use conditioned on outdoor temperature, provide insight into model hyperparameter sensitivity, and demonstrate how readily models can be generalized to unseen buildings.

Skomski, Elliott↗

Energy impact of human health and wellness lighting recommendations for office and classroom applications

The goal of this investigation was to evaluate potential energy impacts of circadian lighting design recommendations gaining attention in a variety of common applications such as offices and classrooms. The renewed focus on health along with advances in SSL technology capabilities has underscored that there is still much to learn regarding the relationship between light and human physiology. The energy implications of designing to address these possible physiological effects are not yet fully understood. Beyond the fact that the basic metric of luminous efficacy (lumens per watt) does not cover these other effects, the emerging science seems to indicate that addressing a holistic view of the human needs in most applications may mean a need for increased light and associated energy use by electric lighting systems. Within the two applications considered, lumen output, spectral characteristics, surface reflectance distribution and desk orientation were varied to explore the magnitude of potential effects. Meeting current IES illuminance recommendations did not satisfy existing EML and CS recommendations for any of the simulations. In some cases, satisfying circadian metric recommendations required average illuminance that was more than double IES recommendations, which may negatively impact lighting quality as well. Using results from 45 unique simulation conditions, it was estimated that lighting energy use may increase between 10% and 100% due to increased luminaire light levels used to meet circadian lighting design recommendations listed in current building standards such as WELL v2 Q2 2019, UL Design Guideline 24480, and CHPS Core Criteria 3.0.

circadian lighting, lighting simulation, solid sta↗

A zone-level occupancy counting system for commercial office spaces using low-resolution time-of-flight sensors

Understanding the locations of occupants in a commercial built environment is critical for realizing energy savings by delivering lighting, heating, and cooling only where it is needed. In this paper, we present an indoor occupancy counting system using a sparse array of inexpensive, low-resolution, and privacy-preserving time-of-flight sensors. We develop and validate an algorithm for zonal occupancy counting that can deal with multiple people walking underneath the sensors in arbitrary directions, and evaluate the system both in realistic simulations of office spaces and in a real-world installation. Finally, we found that our system has an error rate of around 0.4%, resulting in highly accurate person localization and zone counting using only a few sensors per space.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An experimental study on round-trip efficiency of a preheating control with a medium office building

The interactions between building energy efficiency and demand response (DR) with buildings may complicate their impacts on the electricity grid and buildings, yet those interactions are not well understood. This work fills this gap by presenting an experimental study that quantifies the effects of DR on building energy efficiency. Unlike existing studies, this work 1) investigates the uncertainty levels when assessing the effects of DR; 2) studies the impact of rooftop heat pumps with direct expansion refrigerant-to-air coils on the round-trip efficiency. Specifically, we considered a medium office building (~1860 m 2 ), which is served by rooftop units, located in eastern Washington State. We performed preheating control tests during typical heating days in the year 2022 and compared the building’s energy consumption during the testing days to that during normal operation days under similar weather conditions. To understand how well those normal operation days represent the baseline for the assessment, the relationship between the energy performance of this building and weather conditions was also studied. Experimental results reveal that the round-trip efficiency (i.e., the ratio of discharging energy output from the building to charging energy input into the building) was between 0.16 and 0.92. The results show that significant energy loss may occur during the preheating process. Finally, it also suggests a significant correlation between the energy efficiency of the studied building under the preheating control and the outdoor temperature; and a highly nonlinear relationship between the zone temperature changing rate and the weather condition.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy characteristics of multi-chiller load distribution algorithms in a large office building

Here, this study evaluates the energy efficiency of multi-chiller systems in large office buildings, focusing on their optimization across various climate zones as defined by ASHRAE. Using EnergyPlus for simulations, the research examines five different load distribution algorithms in multi-chiller systems that range from one to ten chillers, aiming to understand their effectiveness in 15 distinct climate zones. The primary objectives of the study include identifying the energy efficiency of multi-chiller systems in each climate zone, determining the appropriate number of chillers for each zone, and evaluating the performance of the load distribution algorithms. Based on the U.S. Department of Energy’s commercial building model, the results suggest that multi-chiller systems can significantly reduce cooling energy consumption in various climates. Among the algorithms evaluated, the Sequential Uniform Part Load Ratio (SUPLR) algorithm demonstrates notable efficiency, especially in the 4A climate zone (Baltimore), where it achieves substantial energy savings. Applying the SUPLR algorithm in a multi-chiller setup with four chillers in this zone leads to an estimated 24.5 % reduction in energy usage, equivalent to 183 MW annually. The research indicates that a range of 3 to 5 chillers is typically optimal for most climate zones. In-depth analysis in the 4A climate zone highlights the importance of minimizing operation hours at low Part Load Ratios (PLR) to ensure that chillers operate at a high Coefficient of Performance (COP). This strategy underscores the potential of well-designed multi-chiller systems to reduce cooling energy demand, particularly in climates with transitional seasons. This study provides an overview of the energy-saving potential of multi-chiller systems, applicable across a variety of climatic scenarios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ice storage model-predictive control in an office building with PV: scenario, error and sensitivity analysis

Thermal energy storage (TES) can enable more building-sited renewable electricity generation and lower utility bill costs for buildings owners and occupants, especially when there are high demand and variable time-of-use (TOU) charges. A model predictive control (MPC) strategy can offer additional savings over a schedule-based control with added complexity and reliance on forecasts. Here, this study examines savings for medium office buildings with chiller plants in three locations with building-installed solar photovoltaics (PV) to understand the impact of MPC. Control setpoints are fixed by a schedule-based control or optimized by nonlinear MPC. These control setpoints are actuated within EnergyPlus building models to simulate the utility cost of the chiller plant. NLP solutions can be unstable or unrealistic, but our results show that by regularizing the NLP, the solutions can be reasonably followed by the building model. MPC models make simplifications that lead to errors once the controller is participating in and changing the operation of the building. These errors average 9 % across the cases, showing that the most important parts of the system are represented. The no-thermal load costs are computed to show that the optimization can in some cases achieve both the minimum TOU and minimum monthly demand costs by demand management while reducing TOU energy costs by energy arbitrage. The MPC saves 35–66 % in the annual chiller plant operating costs, which is an additional savings above the schedule by 1–33 %. PV and TES are complementary and mostly independent, but a load with PV often results in better performance for the schedule. Our case study and sensitivity analysis show the importance of modeling and optimization for complex rates, but also the circumstances wherein a simpler strategy achieves the same performance with less potential for error.

14 SOLAR ENERGY↗

Potential benefits and optimization of cool-coated office buildings: A case study in Chongqing, China

Increasing envelope facet albedos considerably reduces solar heat gain, thus yielding building cooling energy savings. Few studies have explored the potential benefits of utilizing cool coatings on building envelopes (“cool-coated buildings”) based on life-cycle cost analysis. A holistic approach integrating the field testing, building energy simulation, and a 20-year life-cycle-based optimization was developed to explore cool-coated building performance and the maximum net savings of optimal building envelope retrofit and design. Experimental results showed that applying cool coatings to a west wall of an office building in Chongqing, China reduced its exterior surface temperature by up to 9.3 °C in summer. Additionally, simulation results showed that in Chongqing, making the roof and walls cool could reduce annual HVAC electricity use by up to 11.9% in old buildings (with poorly insulated envelopes) and up to 5.9% in new buildings. Retrofitting old buildings with a cool roof provided the net savings per modified area with present values up to 42.8 CNY/m2; retrofitting a new building with a cool roof or cool walls was not cost-effective. Optimizing both envelope insulation and envelope albedo can achieve 5.6 times the net savings of optimizing the insulation only, and 1.6 times that of optimizing albedo only.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization of the indoor far-field aerosol transmission in a model commercial office building

As businesses gradually reopen and employees return to work, the potential spread of SARS-CoV-2 and its variants through airborne transmission via the heating, ventilation, and air-conditioning (HVAC) systems of commercial building raises concerns. Since the general practice in commercial buildings is to use low-efficiency air filters and given that indoor air is generally recycled, the degree to which cross-zone aerosol transmission occurs is of interest. To quantify the cross-zone aerosol transmission, experiments were conducted using a synthetic test aerosol in the five zones on the first floor of a model commercial office building at the Oak Ridge National Laboratory. Because the synthetic aerosol was tagged with fluorescent salt, the aerosol generated from the source zone can be distinguished from the background aerosols due to its unique fluorescent signal. Data from cross-zone campaigns showed that submicron-aerosol transmission was higher than the micron aerosols. In campaigns with doors closed, the submicron aerosol transmission was less than 16% and less than 11% for micron aerosol transmission. Finally, opening the interior doors that connecting different zones can significantly enhance the aerosol transmission for zones at the close proximity to the source, but has less impact on those farther away.

60 APPLIED LIFE SCIENCES↗

Harmonic cancellation within AC low voltage distribution for a realistic office environment

An increase of non-linear loads, primarily from power electronics, has substantially increased current harmonics in commercial buildings, which contributes to decreased transformer efficiency / lifespan and poor power quality. This study uses recorded power consumption data from common miscellaneous electric loads (MELs) seen in offices, combined with detailed characterizations of example MELs, to simulate harmonic cancellation within building circuits. Typically, harmonic cancellation studies assume that AC converters operate across their rated power range. However, this study finds that common MELs operate below 40% of rated power the majority of the time when not quiescent; 89% of sampled devices never operated above 60% of rated power. Simulations using these more realistic power levels indicate current-harmonic cancellation (3rd to 13th harmonic) is significantly lower than that predicted when using full-range power assumptions, resulting in minor errors for low-order harmonics and larger errors for higher order harmonics. Furthermore, increased MELs load diversity increases harmonic cancellation, but insufficiently to eliminate errors. In contrast, blending lighting loads with MELs on the secondaries of distribution transformers improves harmonic cancellation to near those predicted by traditional methods. These results indicate that realistic power levels, as well as better characterization of harmonics from typical MELs, should be used to estimate harmonic cancellation.

24 POWER TRANSMISSION AND DISTRIBUTION↗