Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “multiplexing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Multiplexed Predictive Control of a Large Commercial Turbofan Engine

Model predictive control is a strategy well-suited to handle the highly complex, nonlinear, uncertain, and constrained dynamics involved in aircraft engine control problems. However, it has thus far been infeasible to implement model predictive control in engine control applications, because of the combination of model complexity and the time allotted for the control update calculation. In this paper, a multiplexed implementation is proposed that dramatically reduces the computational burden of the quadratic programming optimization that must be solved online as part of the model-predictive-control algorithm. Actuator updates are calculated sequentially and cyclically in a multiplexed implementation, as opposed to the simultaneous optimization taking place in conventional model predictive control. Theoretical aspects are discussed based on a nominal model, and actual computational savings are demonstrated using a realistic commercial engine model.

Richter, hanz↗

Downlink data multiplexer

A data multiplexer that accommodates both industry standard CCSDS data packets and bits streams and standard IEEE 1394 data is described. The multiplexer provides a statistical allotment of bandwidth to the channels in turn, preferably four, but expandable in increments of four up to sixteen. A microcontroller determines bandwidth requested by the plurality of channels, as well as the bandwidth available, and meters out the available bandwidth on a statistical basis employing flow control to the input channels.

Holland, S. Douglas↗

Multiplexed Colorimetric Solid-Phase Extraction

Multiplexed colorimetric solid-phase extraction (MC-SPE) is an extension of colorimetric solid-phase extraction (C-SPE) an analytical platform that combines colorimetric reagents, solid phase extraction, and diffuse reflectance spectroscopy to quantify trace analytes in water. In CSPE, analytes are extracted and complexed on the surface of an extraction membrane impregnated with a colorimetric reagent. The analytes are then quantified directly on the membrane surface using a handheld diffuse reflectance spectrophotometer. Importantly, the use of solid-phase extraction membranes as the matrix for impregnation of the colorimetric reagents creates a concentration factor that enables the detection of low concentrations of analytes in small sample volumes. In extending C-SPE to a multiplexed format, a filter holder that incorporates discrete analysis channels and a jig that facilitates the concurrent operation of multiple sample syringes have been designed, enabling the simultaneous determination of multiple analytes. Separate, single analyte membranes, placed in a readout cartridge create unique, analyte-specific addresses at the exit of each channel. Following sample exposure, the diffuse reflectance spectrum of each address is collected serially and the Kubelka-Munk function is used to quantify each water quality parameter via calibration curves. In a demonstration, MC-SPE was used to measure the pH of a sample and quantitate Ag(I) and Ni(II).

Gazda, Daniel B.↗

Multiplexed Energy Coupler for Rotating Equipment

A multiplexing antenna assembly can efficiently couple AC signal/energy into, or out of, rotating equipment. The unit only passes AC energy while blocking DC energy. Concentric tubes that are sliced into multiple pieces are assembled together so that, when a piece from an outer tube aligns well with an inner tube piece, efficient energy coupling is achieved through a capacitive scheme. With N outer pieces and M inner pieces, an effective N x M combination can be achieved in a multiplexed manner. The energy coupler is non-contact, which is useful if isolation from rotating and stationary parts is required. Additionally, the innovation can operate in high temperatures. Applications include rotating structure sensing, non-contact energy transmission, etc.

Zhao, Xiaoliang↗

Multiplexing Transducers Based on Tunnel-Diode Oscillators

Multiplexing and differential transducers based on tunnel-diode oscillators (TDOs) would be developed, according to a proposal, for operation at very low and/or widely varying temperatures in applications that involve requirements to minimize the power and mass of transducer electronic circuitry. It has been known since 1975 that TDOs are useful for making high-resolution (of the order of 10(exp -9)) measurements at low temperatures. Since that time, TDO transducers have been found to offer the following additional advantages, which the present proposal is intended to exploit: TDO transducers can operate at temperatures ranging from 1 K to about 400 K. Most electronic components other than tunnel diodes do not operate over such a wide temperature range. TDO transducers can be made to operate at very low power - typically, <1 mW. Inasmuch as the response of a TDO transducer is a small change in an arbitrarily set oscillation frequency, the outputs of many TDOs operating at sufficiently different set frequencies can be multiplexed through a single wire. Inasmuch as frequencies can be easily subtracted by means of mixing circuitry, one can easily use two TDOs to make differential measurements. Differential measurements are generally more precise and less susceptible to environmental variations than are absolute measurements. TDO transducers are tolerant to ionizing radiation. Ultimately, the response of a TDO transducer is measured by use of a frequency counter. Because frequency counting can be easily implemented by use of clock signals available from most microprocessors, it is not necessary to incorporate additional readout circuitry that would, if included, add to the mass and power consumption of the transducer circuitry. In one example of many potential variations on the basic theme of the proposal, the figure schematically depicts a conceptual differential-pressure transducer containing a symmetrical pair of TDOs. The differential pressure would be exerted on an electrically conductive and grounded diaphragm, which, at zero differential pressure, would nominally be sprung to a middle position between two capacitor plates that would be parts of the two TDOs. The frequencies of the two TDOs would vary in opposite directions as variations in differential pressure bent the diaphragm away from one capacitor plate and toward the other. The outputs of the TDOs would be mixed and lowpass filtered to obtain a signal at the difference between the frequencies of the two TDOs. The difference frequency would be measured by a frequency counter and converted to differential pressure by a computer.

Chui, Talso↗

Method and Apparatus of Multiplexing and Acquiring Data from Multiple Optical Fibers Using a Single Data Channel of an Optical Frequency-Domain Reflectometry (OFDR) System

A method and system for multiplexing a network of parallel fiber Bragg grating (FBG) sensor-fibers to a single acquisition channel of a closed Michelson interferometer system via a fiber splitter by distinguishing each branch of fiber sensors in the spatial domain. On each branch of the splitter, the fibers have a specific pre-determined length, effectively separating each branch of fiber sensors spatially. In the spatial domain the fiber branches are seen as part of one acquisition channel on the interrogation system. However, the FBG-reference arm beat frequency information for each fiber is retained. Since the beat frequency is generated between the reference arm, the effective fiber length of each successive branch includes the entire length of the preceding branch. The multiple branches are seen as one fiber having three segments where the segments can be resolved. This greatly simplifies optical, electronic and computational complexity, and is especially suited for use in multiplexed or branched OFS networks for SHM of large and/or distributed structures which need a lot of measurement points.

Parker, Jr., Allen R↗

Multiplexing of Hot-Electron Nanobolometers Using Microwave SQUIDs

We have obtained the first data on the multiplexed operation of titanium hot-electron bolometers (HEB). Because of their low thermal conductance and small electron heat capacity nanobolometers are particularly interesting as sensors for far-infrared spectroscopy and mid- and near-IR calorimetry. However, the short time constant of these devices (approximately microseconds at 300-400 mK) makes time domain or audio-frequency domain multiplexing impractical. The Microwave SQUID (MSQUID) approach pursued in this work uses dc SQUIDs coupled to X-band microresonators which are, in turn, coupled to a transmission line. We used a 4-element array of Ti HEBs operated at 415 mK in a He3 dewar with an optical fiber access. The microwave signal exhibited 10-MHz wide resonances at individual MSQUD frequencies between 9 GHz and 10 GHz. The resonance depth is modulated by the current through the bolometer via a change of the SQUID flux state. The transmitted signal was amplified by a cryogenic amplifier and downconverted to baseband using an IQ mixer. A 1-dB per ??/2 responsivity was sufficient for keeping the system noise at the level of ~ 2 pA/Hz1/2. This is more than an order of magnitude smaller than phonon noise in the HEB. The devices were able to detect single near- IR photons (1550 nm) with a time constant of 3.5 ?s. Follow-on work will scale the array to larger size and will address the microwave frequency signal generation and processing using a digital transceiver.

microwave readout↗

Dynamic Time Multiplexing Fabrication of Holographic Polymer Dispersed Liquid Crystals for Increased Wavelength Sensitivity

Described herein is a new holographic polymer dispersed liquid crystal (HPDLC) medium with broadband reflective properties, and a new technique for fabrication of broadband HPDLC mediums. The new technique involves dynamic variation of the holography setup during HPDLC formation, enabling the broadening of the HPDLC medium's wavelength response. Dynamic variation of the holography setup may include the rotation and/or translation of one or more motorized stages, allowing for time and spatial, or angular, multiplexing through variation of the incident angles of one or more laser beams on a pre-polymer mixture during manufacture. An HPDLC medium manufactured using these techniques exhibits improved optical response by reflecting a broadband spectrum of wavelengths. A new broadband holographic polymer dispersed liquid crystal thin film polymeric mirror stack with electrically-switchable beam steering capability is disclosed. XXXX Described herein is a new holographic polymer dispersed liquid crystal (HPDLC) medium with broadband reflective properties, and a new technique for fabrication of broadband 10 HPDLC mediums. The new technique involves dynamic variation of the holography setup during HPDLC formation, enabling the broadening of the HPDLC medium's wavelength response. Dynamic variation of the holography setup may include the rotation and/or translation of one or more 15 motorized stages, allowing for time and spatial, or angular, multiplexing through variation of the incident angles of one or more laser beams on a pre-polymer mixture during manufacture. An HPDLC medium manufactured using these techniques exhibits improved optical response by reflecting 20 a broadband spectrum of wavelengths. A new broadband holographic polymer dispersed liquid crystal thin film polymeric mirror stack with electrically switchable beam steering capability is disclosed.

Fontecchio, Adam K.↗

Toward Large FOV High-Resolution X-Ray Imaging Spectrometer: Microwave Multiplexed Readout of 32 TES Microcalorimeters

We performed a small-scale demonstration at GSFC of high-resolution x-ray TES microcalorimeters read out using a microwave SQUID multiplexer. This work is part of our effort to develop detector and readout technologies for future space based x-ray instruments such as the microcalorimeter spectrometer envisaged for Lynx, a large mission concept under development for the Astro 2020 Decadal Survey. In this paper we describe our experiment, including details of a recently designed, microwave-optimized low-temperature setup that is thermally anchored to the 50 mK stage of our laboratory ADR. Using a ROACH2 FPGA at room temperature, we simultaneously read out 32 pixels of a GSFC-built detector array via a NIST-built multiplexer chip with Nb coplanar waveguide resonators coupled to RF SQUIDs. The resonators are spaced 6 MHz apart (at approx. 5.9 GHz) and have quality factors of approximately 15,000. Using flux-ramp modulation frequencies of 160 kHz we have achieved spectral resolutions of 3 eV FWHM on each pixel at 6 keV. We will present the measured system-level noise and maximum slew rates, and briefly describe the implications for future detector and readout design.

Yoon, Wonsik↗

Frequency Multiplexed Radio Frequency Identification

A radio frequency identification (RFID) system for frequency multiplexing includes, in an exemplary embodiment, an RFID interrogator configured for generating an RFID signal, wherein a channel frequency of the RFID signal changes over time within an operating bandwidth; and one or more electromagnetic transmissive elements each extending between a first end thereof and a second end thereof, each of the electromagnetic transmissive elements electrically coupled with the RFID interrogator at the first end thereof, each of the electromagnetic transmissive elements comprising a frequency dependent load at the second end thereof and configured for transmitting the RFID signal from the RFID interrogator to the frequency dependent load, wherein the frequency dependent load presents different electromagnetic characteristics to the RFID signal transmitted to the frequency dependent load depending on the channel frequency of the RFID signal. Other embodiments include a method for frequency multiplexing including similar components.

Fink, Patrick W.↗

Toward Large Field-Of-View High-Resolution X-Ray Imaging Spectrometers: Microwave Multiplexed Readout of 28 TES Microcalorimeters

We performed small-scale demonstrations at GSFC of high-resolution Xray TES microcalorimeters read out using a microwave SQUID multiplexer. This work is part of our effort to develop detector and readout technologies for future space-based X-ray instruments such as the microcalorimeter spectrometer envisaged for Lynx, a large mission concept under development for the Astro 2020 Decadal Survey. In this paper we describe our experiment, including details of a recently designed, microwave-optimized low-temperature setup that is thermally anchored to the 55mKstage of our laboratory ADR. Using aROACH2 FPGA at room temperature, we read out pixels of a GSFC-built detector array via a NIST-built multiplexer chip with Nb coplanar waveguide resonators coupled to rf-SQUIDs. The resonators are spaced 6 MHz apart (at ∼ 5.9 GHz) and have quality factors of ∼ 15,000. In our initial demonstration, we used flux-ramp modulation frequencies of 125 kHz to read out 5 pixels simultaneously and achieved spectral resolutions of 2.8-3.1 eV FWHM at 5.9 keV. Our subsequent work is ongoing: to-date we have achieved a median spectral resolution of 3.4 eV FWHM at 5.9 keV while reading out 28 pixels simultaneously with flux-ramp frequencies of 160 kHz. We present the measured system-level noise and maximum slew rates and briefly describe our future development work.

Yoon, W.↗

Frequency Multiplexed Radio Frequency Identification

A radio frequency identification (RFID) system for frequency multiplexing includes, in one exemplary embodiment, and RFID interrogator configured for generating an RFID signal, wherein a channel frequency of the RFID signal changes over time; a first narrow band antenna, characterized by a first passband, the first passband corresponding to a first range of frequencies; a second narrow band antenna, characterized by a second passband, the second passband corresponding to a second range of frequencies, wherein the second range of frequencies differs from the first range of frequencies, whereby the second passband differs from the first passband; and first and second feed lines configured for feeding the RFID signal to each of the first and second narrow band antennas, respectively. Other embodiments include systems and methods including similar and different RFID components and aspects for frequency multiplexing.

Fink, Patrick W.↗

Method Development for Multiplex, In-Situ, and Real-Time Detection of Herpesvirus Reactivation in Spaceflight Crews using Nanopore Sequencing

Reactivation of latent herpesviruses in crews onboard the International Space Station (ISS) is a well-established spaceflight-associated phenomenon and has been linked to overall immune stress. Beyond an indicator of an altered immune state, this stress-induced reactivation of viruses such as herpesvirus simplex virus 1 (HSV-1), Epstein-Barr virus (EBV), and Varicella-Zoster virus (VZV) may cause clinical symptoms in crew. There is currently no established protocol for in-flight monitoring, and samples are analyzed post-flight using ground-based assays. A real-time, in-flight method for herpesvirus detection followed by stress-mitigation strategies would be a significant advance. In this study, we developed a real-time assay for the multiplex detection of HSV-1, EBV, and VZV from saliva that could be implemented for in-situ monitoring of ISS crew. This method builds on previously validated spaceflight-compatible portable molecular protocols and platforms, such as the miniPCR thermal cycler and the MinION sequencer. Since a metagenomic approach is not currently permitted for crew samples (NASA policy), we employed multiplexing-ready primers directed toward targeted regions within the HSV-1, EBV, and VZV genomes. We also used primers for the human gene, Statherin (STATH), as an internal control. These primers were validated using spiked-in, positive control HSV-1, EBV, and VZV from virus-negative saliva extracted using the Zymo-Research Quick-DNA/RNA Viral MagBead Kit. The PCR Barcoding Kit was used to prepare DNA libraries that were then sequenced on the MK1C and analyzed against known reference genomes using minimap2. Following validation of this method with spiked saliva samples, suspected herpesvirus-positive clinical saliva samples were successfully tested. Prior to use onboard the ISS, this method will be deployed to an analog environment during overwintering at Palmer Station, Antarctica in 2023. This work represents the successful application of molecular technologies currently onboard the ISS for the real-time monitoring of latent herpesvirus reactivation from saliva samples. This assay, in combination with stress-reduction strategies, holds the potential to manage herpesvirus reactivation in ISS crew, thereby improving health outcomes and overall immunity.

Patrick M. Rydzak↗

Multiplex RNA-guided genome engineering

Methods of multiplex genome engineering in cells using Cas9 is provided which includes a cycle of steps of introducing into the cell a first foreign nucleic acid encoding one or more RNAs complementary to the target DNA and which guide the enzyme to the target DNA, wherein the one or more RNAs and the enzyme are members of a co-localization complex for the target DNA, and introducing into the cell a second foreign nucleic acid encoding one or more donor nucleic acid sequences, and wherein the cycle is repeated a desired number of times to multiplex DNA engineering in cells.

Church, George M.↗

An antibody-free platform for multiplexed, sensitive quantification of protein biomarkers in complex biomatrices

Sensitive, multiplexed protein quantification remains challenging despite recent advancements in LC-MS assays for targeted protein biomarker quantification. High-sensitivity protein biomarker measurements usually require immuno-affinity enrichment of target protein; a process which is highly dependent on capture reagent and limited in capability to measure multiple analytes. Herein, we report a novel antibody-free platform, which measures multiple biomarkers from complex matrices employing a strategically optimized solid-phase extraction cleanup and orthogonal multidimensional LC-MS. Eight human protein biomarkers with different specifications were spiked into canine plasma as a model investigation system. The developed strategy achieved the desired sensitivity, robustness, and throughput via the following steps: (1) post digestion mixed-mode cation exchange-reverse phase SPE enrichment cleaned up the sample initially; (2) rapid, high-pH peptide fractionation further eliminated background components efficiently while selectively enriched signature peptides (SP) to provide sufficient sensitivity for multiple targets; and (3) trapping-micro-LC-MS analysis delivered high sensitivity comparable to a nano-LC-MS method but with much better robustness and throughput for the final analysis. Compared with a conventional LC-MS assay with direct protein digestion and limited clean-up, analysis with this antibody-free platform improved the LLOQ by 1–2 orders of magnitude for the eight protein biomarkers, reaching as low as 5 ng/mL in plasma, with feasible robustness and throughput. In conclusion, this platform was applied for the quantification of biomarkers of respiratory conditions in patients with various lung diseases, demonstrating real-world applicability.

59 BASIC BIOLOGICAL SCIENCES↗

An automated multiplexed turbidometric and data collection system for measuring growth kinetics of anaerobes dependent on gaseous substrates

Standard methods of monitoring the growth kinetics of anaerobic microorganisms are generally impractical when there is a protracted or indeterminate period of active growth, and when high numbers of samples or replications are required. As part of our studies of the adaptive evolution of a simple anaerobic syntrophic mutualism, requiring the characterization of many isolates and alternative syntrophic pairings, here we developed a multiplexed growth monitoring system using a combination of commercially available electronics and custom designed circuitry and materials. This system automatically monitors up to 64 sealed, and as needed pressurized, culture tubes and reports the growth data in real-time through integration with a customized relational database. The utility of this system was demonstrated by resolving minor differences in growth kinetics associated with the adaptive evolution of a simple microbial community comprised of a sulfate reducing bacterium, Desulfovibrio vulgaris, grown in syntrophic association with Methanococcus maripaludis, a hydrogenotrophic methanogen.

59 BASIC BIOLOGICAL SCIENCES↗

Multiplexing and Demultiplexing Signals for Radiography Application Using the Discrete Fourier Transform

Our goal is to develop an X-ray phase-contrast imaging system that can provide excellent soft tissue contrast of phase, attenuation, and small-angle scatter. We propose to replace the common system of G0, G1, and G2 gradings with a biprism array to replace the G1 grading and introduce a novel X-ray tube designed to replace the motion of the phase stepping grading G2. The proposed X-ray tube uses temporal multiplexing to provide simultaneous virtual “electronic phase stepping.” In this work the discrete Fourier transform is used to separate from the composite measurement individual X-ray phase contrast measurements sampled at different frequencies. The method performs a discrete Fourier transform of a composite refence sequence to obtain using the frequency amplitudes calibration factors needed to extract the X-ray phase contrast measurement amplitudes from the composite image. The composite reference sequence is the sum of the individual sequences, at different frequencies, with amplitudes of one. The method takes the discrete Fourier transform of this composite reference sequence; whereby, the amplitude of each frequency component is compared with the total sum of its stand-alone sequence amplitude. A calibration factor is determined so that the amplitude of this composite reference frequency times the calibration factor must equal the total sum of the sequence amplitude—the zero-frequency amplitude of the discrete Fourier transform of its stand-alone sequence. To demultiplex the composite measured signal these calibration factors are multiplied by the amplitudes of the frequency components of the discrete Fourier transform of the composite X-phase-contrast measurement to obtain the amplitude of each frequency encoded measurement. Using these calibration factors, we demonstrate with the discrete Fourier transform in Mathematica the extraction of individual images from a composite image that one would expect obtaining from our proposed new X-ray phase contrast imaging system. We then demonstrate as an example how using images from X-ray phase contrast data one can calculate phase, attenuation and the dark field images using grading phase step data supplied to use from Microworks, GmbH in Karlsruhe, Germany.

42 ENGINEERING↗