Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “multiple sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

An analysis pipeline for the inference of protein-protein interaction networks

An analysis pipeline has been created for deployment of a novel algorithm, the Bayesian Estimator of Protein-Protein Association Probabilities (BEPro), for use in the reconstruction of protein-protein interaction networks. We have combined the Software Environment for BIological Network Inference (SEBINI), an interactive environment for the deployment and testing of network inference algorithms that use high-throughput data, and the Collective Analysis of Biological Interaction Networks (CABIN), software that allows integration and analysis of protein-protein interaction and gene-to-gene regulatory evidence obtained from multiple sources, to allow interactions computed by BEPro to be stored, visualized, and further analyzed. Incorporating BEPro into SEBINI and automatically feeding the resulting inferred network into CABIN, we have created a structured workflow for protein-protein network inference and supplemental analysis from sets of mass spectrometry bait-prey experiment data. SEBINI demo site: https://www.emsl.pnl.gov /SEBINI/ Contact: ronald.taylor@pnl.gov. BEPro is available at http://www.pnl.gov/statistics/BEPro3/index.htm. Contact: ds.daly@pnl.gov. CABIN is available at http://www.sysbio.org/dataresources/cabin.stm. Contact: mudita.singhal@pnl.gov.

59 BASIC BIOLOGICAL SCIENCES↗

DISK AND ENVELOPE STRUCTURE IN CLASS 0 PROTOSTARS. II. HIGH-RESOLUTION MILLIMETER MAPPING OF THE SERPENS SAMPLE

We present high-resolution CARMA 230 GHz continuum imaging of nine deeply embedded protostars in the Serpens Molecular Cloud, including six of the nine known Class 0 protostars in Serpens. This work is part of a program to characterize disk and envelope properties for a complete sample of Class 0 protostars in nearby low-mass star-forming regions. Here, we present CARMA maps and visibility amplitudes as a function of uv-distance for the Serpens sample. Observations are made in the B, C, D, and E antenna configurations, with B configuration observations utilizing the CARMA Paired Antenna Calibration System. Combining data from multiple configurations provides excellent uv-coverage (4-500 k{lambda}), allowing us to trace spatial scales from 10{sup 2} to 10{sup 4} AU. We find evidence for compact disk components in all of the observed Class 0 protostars, suggesting that disks form at very early times (t < 0.2 Myr) in Serpens. We make a first estimate of disk masses using the flux at 50 k{lambda}, where the contribution from the envelope should be negligible, assuming an unresolved disk. The resulting disk masses range from 0.04 M{sub sun} to 1.7 M{sub sun}, with a mean of approximately 0.2 M{sub sun}. Our high-resolution maps are also sensitive to binary or multiple sources with separations {approx}> 250 AU, but significant evidence of multiplicity on scales <2000 AU is seen in only one source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New multiple systems in molecular clouds

Twenty-micron searches of the dense cores of the molecular clouds S140, S255, and Cepheus A have revealed the existence of multiple sources of infrared radiation which seem to be precursors to Trapezium-like clusters of OB stars. Two of the new sources are extended with unusually low color temperatures, less than 100 K. Observations with the Very Large Array with 1 mJy sensitivity have shown that three and possibly four of the infrared sources are associated with small H II regions. Multiple systems appear to be the rule rather than the exception in molecular clouds.

Beichman, C. A.↗

A Roadmap for using Agile Development in a Traditional System

I. Ensemble Development Group: a) Produces activity planning software for in spacecraft; b) Built on Eclipse Rich Client Platform (open source development and runtime software); c) Funded by multiple sources including the Mars Technology Program; d) Incorporated the use of Agile Development. II. Next Generation Uplink Planning System: a) Researches the Activity Planning and Sequencing Subsystem for Mars Science Laboratory (APSS); b) APSS includes Ensemble, Activity Modeling, Constraint Checking, Command Editing and Sequencing tools plus other uplink generation utilities; c) Funded by the Mars Technology Program; d) Integrates all of the tools for APSS.

uplink planning systems↗

Single Quadrupole Multiple Fragment Ion Monitoring Quantitative Mass Spectrometry

Single quadrupole mass spectrometry (MS) with enhanced in-source multiple fragment ion monitoring was designed to perform high sensitivity quantitative mass analyses. Enhanced in-source fragmentation amplifies fragmentation from traditional soft electrospray ionization producing fragment ions that have been found to be identical to those generated in tandem MS. We have combined enhanced in-source fragmentation data with criteria established by the European Union Commission Directive 2002/657/EC for electron ionization single quadrupole quantitative analysis to perform quantitative analyses. These experiments were performed on multiple types of complex samples that included a mixture of 50 standards, as well as cell and plasma extracts. The dynamic range for these quantitative analyses was comparable to triple quadrupole multiple reaction monitoring (MRM) analyses at up to 5 orders of magnitude with the cell and plasma extracts showing similar matrix effects across both platforms. Amino acid and fatty acid measurements performed from certified NIST 1950 plasma with isotopically labeled standards demonstrated accuracy in the range of 91–110% for the amino acids, 76–129% for the fatty acids, and good precision (coefficient of variation <10%). To enhance specificity, a newly developed correlated ion monitoring algorithm was designed to facilitate these analyses. This algorithm autonomously processes, aligns, filters, and compiles multiple ions within one chromatogram enabling both precursor and in-source fragment ions to be correlated within a single chromatogram, also enabling the detection of coeluting species based on precursor and fragment ion ratios. Single quadrupole instrumentation can provide MRM level quantitative performance by monitoring/correlating precursor and fragment ions facilitating high sensitivity analysis on existing single quadrupole instrumentation that are generally inexpensive, easy to operate, and technically less complex.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Lead Isotope Fingerprinting of Nanoscale Mineral Particles via Single Particle Inductively Coupled Plasma Mass Spectrometry

Determining lead (Pb) isotopic ratios is of broad interest across chemical disciplines for source tracing and age determinations, but the technique is inherently limited when multiple sources of Pb are present in a single sample. Single particle methods offer a solution to directly resolve multiple distinct isotopic ratios within individual samples. In this study, single particle inductively coupled plasma-mass spectrometry (spICP-MS) was performed using time-of-flight (TOF) and multicollector (MC)-based platforms to measure the Pb isotopic composition of individual nanoscale particles. Distinct Pb isotope ratios were measured in particles from four powdered galena samples of different origins (average single-particle 206Pb/207Pb ratios ranging from 0.91 to 1.28) using both the TOF and the MC-based platforms. Differentiation of galena particles in a mixture (liberated grains and those hosted in a silicate matrix) was possible due to detecting their unique multielemental fingerprints. The differing behavior of the two galena samples during digestion was investigated; undigested galena particles trapped within silicate minerals were detected using spICP-MS, which has implications for Pb recovery in bulk-scale isotopic analysis. The multinuclide detection capability of the ICP-TOF-MS instrument allowed for the simultaneous detection of secondary constituent elements within the nanoparticles and the identification of multiple populations of isotopically distinct Pb-bearing particles in a copper ore sample, whereas the increased sensitivity of the MC instrument enabled quantification of 204Pb, allowing differentiation using multiple isotopic ratios. A single particle isotope ratio analysis module was developed within an open-source spICP-TOF-MS data processing platform, enabling its adoption across chemical disciplines.

Goodman, Aaron J. [University of Montreal, Quebec,↗

Fourth Annual International Acquisitions Workshop: Access to Multiple Media Worldwide

Topics discussed during the workshop include: (1) Multinational-Multiple media collections and activities spanning many countries; (2) Multiple media in North American trade and commerce; (3) African spotlight; (4) Europe-Multiple media in national libraries and services; (5) Scandinavian spotlight; (6) Internet update; (7) Multiple media in US federal agencies; (8) Open-source multiple media in US federal agencies; and (9) Multiple media at US federal technical agencies-NIST and NOAA.

Source record↗

Time Domain Boundary Element Method Prediction of Noise Shielding by a NACA 0012 Airfoil

As aircraft noise constraints become more stringent and the number/mixture of aircraft configurations grows, it becomes more important to understand the interaction of individual aircraft noise sources with nearby aircraft structures. Understanding these interactions and exploring possible approaches to mitigate or exploit their acoustic impact is essential for overcoming key noise barriers. This paper describes the further validation of a time domain boundary element approach for the prediction of the interactions between incident noise sources and nearby aircraft structures. Predictions were completed for multiple source locations and comparisons of these results with measured data are presented. Overall, very good agreement between the predicted and measured quantities was obtained in both the pressure time histories and pressure spectra. The effects of surface mesh resolution and source waveform are also presented. The very promising results demonstrate the capabilities of the time domain methodology employed in this study and provide further confidence in its continued development and application in future studies.

TD-FAST↗

Neutron imaging with coded sources: new challenges and the implementation of a simultaneous iterative reconstruction technique

The limitations in neutron flux and resolution (L/D) of current neutron imaging systems can be addressed with a Coded Source Imaging system with magnification (xCSI). More precisely, the multiple sources in an xCSI system can exceed the flux of a single pinhole system for several orders of magnitude, while maintaining a higher L/D with the small sources. Moreover, designing for an xCSI system reduces noise from neutron scattering, because the object is placed away from the detector to achieve magnification. However, xCSI systems are adversely affected by correlated noise such as non-uniform illumination of the neutron source, incorrect sampling of the coded radiograph, misalignment of the coded masks, mask transparency, and the imperfection of the system Point Spread Function (PSF). We argue that a model-based reconstruction algorithm can overcome these problems and describe the implementation of a Simultaneous Iterative Reconstruction Technique algorithm for coded sources. Design pitfalls that preclude a satisfactory reconstruction are documented.

Santos-Villalobos, Hector J↗

Expanding on Successful Concepts, Models, and Organization

In her letter to the editor1 regarding our recent Feature Article “Completing the Link between Exposure Science and Toxicology for Improved Environmental Health Decision Making: The Aggregate Exposure Pathway Framework” 2, Dr. von Göetz expressed several concerns about terminology, and the perception that we propose the replacement of successful approaches and models for exposure assessment with a concept. We are glad to have the opportunity to address these issues here. If the goal of the AEP framework was to replace existing exposure models or databases for organizing exposure data with a concept, we would share Dr. von Göetz concerns. Instead, the outcome we promote is broader use of an organizational framework for exposure science. The framework would support improved generation, organization, and interpretation of data as well as modeling and prediction, not replacement of models. The field of toxicology has seen the benefits of wide use of one or more organizational frameworks (e.g., mode and mechanism of action, adverse outcome pathway). These frameworks influence how experiments are designed, data are collected, curated, stored and interpreted and ultimately how data are used in risk assessment. Exposure science is poised to similarly benefit from broader use of a parallel organizational framework, which Dr. von Göetz correctly points out, is currently used in the exposure modeling community. In our view, the concepts used so effectively in the exposure modeling community, expanded upon in the AEP framework, could see wider adoption by the field as a whole. The value of such a framework was recognized by the National Academy of Sciences.3 Replacement of models, databases, or any application with the AEP framework was not proposed in our article. The positive role broader more consistent use of such a framework might have in enabling and advancing “general activities such as data acquisition, organization…,” and exposure modeling was discussed in some detail. Like Dr. von Göetz, we recognized the challenges associated with acceptance of the terminology, definitions, and structure proposed in the paper. To address these challenges, an expert workshop was held in May, 2016 to consider and revise the “basic elements” outlined in the paper. The attendees produced revisions to the terminology (e.g., key events) that align with terminology currently in use in the field. We were also careful in our paper to acknowledge a point raised by Dr. von Göetz, that the term AEP implies aggregation, providing these clarifications: “The simplest form of an AEP represents a single source and a single pathway and may more commonly be referred to as an exposure pathway,”; and “An aggregate exposure pathway may represent multiple sources and transfer through single pathways to the TSE, single sources and transfer through multiple pathways to the target site exposure (TSE), or any combination of these.” These clarifications address the concern that the AEP term is not accurate or logical, and further expands upon the word “aggregate” in a broader context. Our use of AEP is consistent with the definition for “aggregate exposure”, which refers to the combined exposures to a single chemical across multiple routes and pathways.3 The AEP framework embraces existing methods for collection, prediction, organization, and interpretation of human and ecological exposure data cited by Dr. von Göetz. We remain hopeful that wider recognition and use of an organizing concept for exposure information across the exposure science, toxicology and epidemiology communities advances the development of the kind of infrastructure and models Dr. von Göetz discusses. This outcome would be a step forward, rather than a step backward.

exposure science↗

Einstein Observatory survey of X-ray emission from solar-type stars - The late F and G dwarf stars

Results of a volume-limited X-ray survey of stars of luminosity classes IV and V in the spectral range F7-G9 observed with the Einstein Observatory are presented. Using survival analysis techniques, the stellar X-ray luminosity function in the 0.15-4.0 keV energy band for both single and multiple sources. It is shown that the difference in X-ray luminosity between these two classes of sources is consistent with the superposition of individual components in multiple-component systems, whose X-ray properties are similar to those of the single-component sources. The X-ray emission of the stars in our sample is well correlated with their chromospheric CA II H-K line emission and with their projected equatorial rotational velocity. Comparison of the X-ray luminosity function constructed for the sample of the dG stars of the local population with the corresponding functions derived elsewhere for the Hyades, the Pleiades, and the Orion Ic open cluster confirms that the level of X-ray emission decreases with stellar age.

Maggio, A.↗

DISENTANGLING CONFUSED STARS AT THE GALACTIC CENTER WITH LONG-BASELINE INFRARED INTERFEROMETRY

We present simulations of Keck Interferometer ASTRA and VLTI GRAVITY observations of mock star fields in orbit within {approx}50 mas of Sgr A*. Dual-field phase referencing techniques, as implemented on ASTRA and planned for GRAVITY, will provide the sensitivity to observe Sgr A* with long-baseline infrared interferometers. Our results show an improvement in the confusion noise limit over current astrometric surveys, opening a window to study stellar sources in the region. Since the Keck Interferometer has only a single baseline, the improvement in the confusion limit depends on source position angles. The GRAVITY instrument will yield a more compact and symmetric point-spread function, providing an improvement in confusion noise which will not depend as strongly on position angle. Our Keck results show the ability to characterize the star field as containing zero, few, or many bright stellar sources. We are also able to detect and track a source down to m{sub K} {approx} 18 through the least confused regions of our field of view at a precision of {approx}200 {mu}as along the baseline direction. This level of precision improves with source brightness. Our GRAVITY results show the potential to detect and track multiple sources in the field. GRAVITY will perform {approx}10 {mu}as astrometry on an m{sub K} = 16.3 source and {approx}200 {mu}as astrometry on an m{sub K} = 18.8 source in 6 hr of monitoring a crowded field. Monitoring the orbits of several stars will provide the ability to distinguish between multiple post-Newtonian orbital effects, including those due to an extended mass distribution around Sgr A* and to low-order general relativistic effects. ASTRA and GRAVITY both have the potential to detect and monitor sources very close to Sgr A*. Early characterizations of the field by ASTRA, including the possibility of a precise source detection, could provide valuable information for future GRAVITY implementation and observation.

79 ASTRONOMY AND ASTROPHYSICS↗

Equivalent Fundamental-Mode Source Simulations for Spherical Uranium and Plutonium Systems [Abstract]

The equivalent fundamental-mode source refers to a “source” which is identically distributed in space, energy, and angle as that of a fundamental-mode fission source distribution. It has previously been shown that the system fixed source multiplication ($M_{fs}$) relates to the effective multiplication factor ($\kappa_{eff}$) as $M_{fs} = \frac{g^*}{1-k_{eff}}$ The term $\mathcal{g}$* therefore relates the system source distribution to the system equivalent fundamental-mode source. As previously shown, the $\mathcal{g}$* term is approximately 1 for deeply subcritical systems and then diverges as the system multiplication increases. For a system with a point source located in the center of an assembly (such a sphere), $\mathcal{g}$* will be greater than 1; this happens because there is a higher probability of induced fission when all of the starter neutrons originate from the center of the sphere. For a uniform source, $\mathcal{g}$* is less than 1, but does not diverge from 1 as dramatically as seen by a point source. One reason that $\mathcal{g}$* is an important parameter is that it is used in measurement methods to infer reactor kinetics parameters ($β_{eff}$ being one example). This work will discuss multiple ways to simulate $\mathcal{g}$* using MCNP®6.2, which include use of traditional methods versus a single input file method that was recently published. A discussion related to methods to simulate $M_{fs}$ will be presented. Spherical systems of Highly Enriched Uranium (HEU) will be compared with previous works. In addition, results of plutonium including multiple reflector materials will be investigated. Simulated systems will include both parametric studies as well as configurations used in recent experiments performed at the National Criticality Experiments Research Center (NCERC). These studies will include subtleties associated with system geometry that have not been previously shown. Last, this work will investigate the relationship between $\mathcal{g}$* and reactor kinetics parameters (such as $β_{eff}$).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of the Mobile Systems for Conditioning of Disused Sealed Radioactive Sources in Serbia - 20105

Sealed radioactive sources (SRS) are being used worldwide in the field of medicine, agriculture, industry and research. They can be found in mobile as well as stationary devices. SRS contains radioactive material that is (a) permanently sealed in a capsule or (b) closely bounded and in a solid form. The capsule or material of an SRS should be strong enough to maintain leak tightness under the conditions of use and purpose for which the source was designed, also in case of accidents. In this case only emitted radiation is utilized. Firstly, the hazard from external radiation has to be considered, but the possibility of contamination due to fracture of the capsule should not be disregarded. The radioactive sources are composed of the radiating isotope contained in the filling medium, the single or double isotope holder that partially or totally surrounds the filling medium, the outer cover that contains the parts mentioned above and the capsule closed airtightly by welding or using some other method. The capsule must be tested for leakage periodically. If the SRS is no longer needed (e.g. replaced by a different technique) or it becomes useless for the intended application (e.g. the activity becomes too weak, the equipment containing the source works poorly or becomes obsolete, the source is damaged or leaking) it is considered disused. Disused sealed radioactive sources (DSRS) are typically conditioned and disposed if a facility is available. If the disposal option is not available, conditioned DSRS should be stored under proper conditions. In some cases, the radionuclide(s) in DSRS can be recovered/recycled or the DSRS can be repurposed for other applications. Conditioning of DSRS ensures containment of the radioactive material, provides confinement for leaking sources, provides sufficient radiation shielding, reduces storage/disposal volume by allowing consolidation of multiple sources into a single storage/disposal container, facilitates transport operations and contributes to safety and security as well. Typically, conditioning technologies are deployed either as permanently installed stationary systems in centralized or mobile on-site waste processing facilities, or in a mobile configuration. Centralized stationary facilities provide a single processing location for multiple users that requires transport of the waste to the facility. On the other hand, mobile systems may be provided for the selection and application of the optimum technology for a specific waste stream (such as DSRS) by bringing the process to the point where the waste is generated. In addition, mobile systems could offer additional flexibility by sharing equipment among multiple waste generating sites for processing campaigns that vary in duration, from very short periods to several years. The term 'mobile processing system' refers to any radioactive waste processing system or component which is designed to be transportable and which is not considered permanently installed. Two mobile system for conditioning of disused sealed radioactive sources are developed in the Public Company Nuclear Facilities of Serbia. Development of these mobile systems was supported by SRB9005 national project via Technical Cooperation of the IAEA. The first mobile system, built inside the 20 feet ISO container, will be used for conditioning of DSRS category 3 to 5. The second mobile system, built inside the 7 m long vehicle (Iveco Daily Van), will be used for dismantling of ionizing smoke detectors mostly with Am-241 sources. Designs of the mobile systems were defined in cooperation with two companies from Belgium (Belgoprocess and Leniko) and a Croatian company Ekoteh as well as with the support of the IAEA experts. The generic safety assessment and operational procedures for the mobile systems are developed. Based on safety assessment the acceptance criteria and operational limits and conditions are established. Operational procedures include: (a) equipment and material requirements, (b) assembling procedure of the mobile unit, (c) procedure for acceptance of devices for dismantling and conditioning, (d) dismantling procedure for devices to recover the DSRS, (e) characterization of DSRS, (f) encapsulation procedure of DSRS, (g) disassembling procedure of the mobile unit, and (h) keeping records, identification and traceability. In addition, radiation safety, health safety, security and emergency preparedness plans are prepared. The generic safety assessment and operational procedures could be updated with site specific requirements, DSRS inventory, and different needs for future customers. Developed mobile systems could be used in all situations when it is feasible to perform conditioning of DSRS on the spot in the county and worldwide. Development of these mobile units was just the first step to create the Reference Center for Radioactive Waste Treatment and Disused Radioactive Sources Conditioning for Small Facilities which can become a regional training center in the future, and/or as a tool for comprehensive national search and secure programmes. In the next phases development of e-learning platforms and blended learning packages as well as application for the IAEA Qualified Technical Centre (QTC) for the management of DSRS is foreseen. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Learning-Based Inversion-Free Model-Data Integration to Advance Ecosystem Model Prediction

Ecosystem model prediction is important for understanding ecosystem responses to climate change and for management support. Model prediction and quantification of predictive uncertainty of ecosystems have long been investigated. The traditional workflow, which calibrates models to match observations and then uses the calibrated models for predictions, relies heavily on inverse modeling to constrain uncertain parameters in complex forward models. This inversion-based prediction approach is infeasible for complex models with heterogeneous parameter uncertainties and incapable of rapid integration of streaming and multiple sources of data because of the difficulty and computational cost in the model inversion, which is typically ill-posed and can require hundreds of thousands of expensive forward simulations to be performed iteratively. We propose to circumvent inverse modeling by precomputing an ensemble of unconstrained forward simulations and then using machine learning (ML) methods to learn the statistical relationship between simulated observation and prediction quantities. Once the ML model has learned the relationship, it can be used to make predictions of future system behavior with uncertainty quantification based on observations. The proposed learningbased inversion-free model prediction (LIMP) framework is computationally efficient which only requires a few thousands of fully parallelizable forward simulations. Additionally, LIMP can continually update predictions based on streaming observations from multiple locations and sources without necessarily requiring extra model simulations. In this study, we apply LIMP to a regional terrestrial ecosystem model with 47 parameters for testing, refining, and evaluating the approach. We demonstrate that LIMP can be used for efficient model prediction, rapid data assimilation, and cost-effective experimental design for improving robust predictive understanding of ecosystems.

Lu, Dan↗

Investigating Particle Phase State Dependencies during a Historic Pacific Northwest Wildfire Event

The function and lifetime of an atmospheric particle are greatly dependent upon its phase state. Studying particle phase states from specific ambient source types is often challenging due to uncontrolled environmental conditions and multiple source contributions. However, a historic Pacific Northwest wildfire event occurred in September 2020, providing a rare opportunity to study a pseudo-single particle type ambient sample (i.e., wildfire) over time. Sampling was performed in Richland, Washington, capturing aged particles from shifting wildfire sources. In addition to source variability, temporal variation in wildfire particle phase state was observed from single particle analyses. Despite this, single particle elemental compositions were homogenous over time (=87% carbonaceous) with no significant temporal variation in organic functional group abundances within individual particles either (e.g., 4% relative standard deviation in alkene contributions). While particle composition is indeed known to affect phase state, water uptake appeared to be the most significant contributor to phase state variability amongst single particles here, as particle aspect ratios (related to phase state) linearly correlated with ambient relative humidity during sampling (R2 = 0.65). Therefore, while limited to a case study, meteorological considerations are found to convey greater comparative importance than particle composition for aged particle phase state predictions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A TECHNIQUE FOR PRIMARY BEAM CALIBRATION OF DRIFT-SCANNING, WIDE-FIELD ANTENNA ELEMENTS

We present a new technique for calibrating the primary beam of a wide-field, drift-scanning antenna element. Drift-scan observing is not compatible with standard beam calibration routines, and the situation is further complicated by difficult-to-parameterize beam shapes and, at low frequencies, the sparsity of accurate source spectra to use as calibrators. We overcome these challenges by building up an interrelated network of source 'crossing points'-locations where the primary beam is sampled by multiple sources. Using the single assumption that a beam has 180 Degree-Sign rotational symmetry, we can achieve significant beam coverage with only a few tens of sources. The resulting network of crossing points allows us to solve for both a beam model and source flux densities referenced to a single calibrator source, circumventing the need for a large sample of well-characterized calibrators. We illustrate the method with actual and simulated observations from the Precision Array for Probing the Epoch of Reionization.

79 ASTRONOMY AND ASTROPHYSICS↗

Impacts of Microbial Growth on the Air Quality of the International Space Station

An understanding of the various sources of non-methane volatile organic compounds (NMVOCs) is one facet to ensuring the habitability of crewed spacecraft. Even though the International Space Station (ISS) atmosphere is relatively well characterized in terms of what is in the atmosphere and approximately how much, linking the majority of these trace contaminants detected to their source is virtually impossible. Albeit a few of can be associated to a single source, the majority of these trace contaminants have their origins from multiple sources. On crewed spacecraft such as ISS, trace contaminants are broadly categorized as either coming from equipment, which includes systems and payloads, or from the metabolic processes of the crew members. Such widely encompassing categories clearly illustrate the difficulty in linking air contaminants to their source(s). It is well known that microbial growth in ISS can flourish if left unchecked. Although processes are in place to limit microbial growth, in reality, microbial growth has pervaded the habitable environment of ISS. This is simply a consequence of having crewed spacecraft, as humans are the largest contributor to the bioload. As with crew members, microbes also have metabolic processes which, in many ways, are comparable to human metabolism. As such, it can be expected that microbial growth can lead to the release of volatile organic compounds into the ISS atmosphere. Given a large enough microbial population, the impact to the air quality of ISS can be potentially large. A survey of the microbiology found in ISS will be presented as well as the possible types of volatile organic compounds that can result from such organisms. This will be correlated to the observations provided by ground-based analysis of ISS atmosphere samples.

Macatangay, Ariel V.↗