Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “microwave sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Hg-201 (+) CO-Magnetometer for HG-199(+) Trapped Ion Space Atomic Clocks

Local magnetic field strength in a trapped ion atomic clock is measured in real time, with high accuracy and without degrading clock performance, and the measurement is used to compensate for ambient magnetic field perturbations. First and second isotopes of an element are co-located within the linear ion trap. The first isotope has a resonant microwave transition between two hyperfine energy states, and the second isotope has a resonant Zeeman transition. Optical sources emit ultraviolet light that optically pump both isotopes. A microwave radiation source simultaneously emits microwave fields resonant with the first isotope's clock transition and the second isotope's Zeeman transition, and an optical detector measures the fluorescence from optically pumping both isotopes. The second isotope's Zeeman transition provides the measure of magnetic field strength, and the measurement is used to compensate the first isotope's clock transition or to adjust the applied C-field to reduce the effects of ambient magnetic field perturbations.

Burt, Eric A.↗

Theory of microwave and X-ray emission

The behaviour of the nonthermal electrons created at the impulsive phase of flares has been deduced from the microwave impulsive bursts and hard X-ray burst by many researchers. There is almost no doubt of the emission mechanisms that radio emissions are due to gyrosynchrotron emission and hard X-rays are collisional bremsstrahlung. However, there remain three controversial problems. One is whether the emission sources of the microwave impulsive burst and hard X-ray burst are common or not. Another is whether the injection of the nonthermal electrons into the source is impulsive or continuous. The other is the relation among the nonthermal electrons, soft X-rays, EUV flash, H-alpha kernels, and white light flares. These three problems are not independent of each other.

Takakura, T.↗

Electron-cyclotron maser emission during flares: Emission in various modes and temporal variations

Absorption of radiation at the electron-cyclotron frequency, OMEGA sub e, generated by the electron-cyclotron maser instability was proposed as a possible mechanism for transporting energy and heating of the corona during flares. Radiation from the same instability but at harmonics of OMEGA sub e is believed to be the source of solar microwave spike bursts. The actual mode and frequency of the dominant emission from the maser instability is shown to be dependent on: (1) the plasma temperature, (2) the form of the energetic electron distribution, and (3) on the ratio of the plasma frequency omega sub p to OMEGA sub e. As a result, the emission along a flux tube can vary, with emission at harmonics being favored in regions where omega sub p/OMEGA sub e approx. equal to or greater than 1. Changes in the plasma density and temperature in the source region associated with the flare can also cause the characteristics of the emission to change in time.

Winglee, R. M.↗

Microwave-driven synthesis and modification of nanocarbons and hybrids in liquid and solid phases

Over the past 20 years, nanocarbons have become more significant as nanostructured fillers in composites and, more recently, as functional elements in a brand-new class of hybrid materials. Microwave-assisted synthesis and processing is a burgeoning subject matter in materials research with significant strides in the realm of nanocarbon during the last decade. Here, the review examines recent approaches to producing various nanocarbons using microwaves as energy sources, the characterization of such materials for various applications, and their results. The underlying factors supporting the increased performance of such materials or their composites are analyzed and reaction mechanisms are presented wherever necessary. In particular, the recently developed and verified approaches to produce porous carbon materials, CNTs and fibers, carbon nanospheres, carbon dots, CQDs, reduced graphene oxide, nanocarbon hybrid materials, and the purification and modification of CNTs are discussed. The reduction of graphene oxide and the preparation of graphene derivative hybrids using solid-state and liquid-state routes such as polyopl, mixed solvents, ionic liquids, and microwave-assisted hydrothermal/solvothermal methods are analyzed in detail. In addition, the principles of microwave heating in liquid and solid states, the use of metals particles as arcing agents or catalysts, and carbonaceous materials as internal or external susceptors during synthesis and modifications are presented in detail.

25 ENERGY STORAGE↗

A comparison of the cosmic microwave and cosmic X-ray backgrounds - Constraints on local sources of the fluctuations observed by COBE

It has been suggested by Hogan (1992) that the microwave background anisotropy detected by the COBE DMR experiment (Smoot et al., 1992) might be produced by inverse Compton scattering from hot diffuse clouds of electrons in nearby superclusters. If the COBE fluctuations are due to this mechanism, then the absence of anticorrelations between maps of the cosmic microwave and cosmic X-ray backgrounds constrains the temperature (16 keV) and density (less than 2 x 10 exp -6/cu cm) of the ionized supercluster gas. Since the COBE limits on spectral distortion indicate that the temperature of the intergalactic medium is less than 10 keV, we conclude that the fluctuations observed by COBE are probably not produced by this mechanism.

Boughn, S. P.↗

Enhanced tensor polarization in solid-state targets

In this work, we report measurements of enhanced tensor polarization on solid-state targets. The results here represent an increase in tensor polarization over that previously achieved in high energy and nuclear scattering experiments that focused on the measurement of tensor polarized observables. Enhancement techniques are used which require RF produced close to the Larmor frequency of the target spins and use selective semi-saturation resulting from two sources of irradiation, microwave for the DNP process and the additional RF used to manipulate the population of the energy levels in the target material. The spin dynamics of the solid target are used to align the spins enhancing the ensemble average to improve the figure of merit of the scattering experiment. Target rotation at an optimized rate can lead to additional enhancement by applying selective semi-saturation in polycrystalline materials that possess a Pake doublet in their NMR signal.

47 OTHER INSTRUMENTATION↗

Multispin Clifford codes for angular momentum errors in spin systems

The physical symmetries of a system play a central role in quantum error correction. Here, in this work we encode a qubit in a collection of systems with angular momentum symmetry (spins), extending the tools developed by Gross for single large spins. By considering large spins present in atomic systems and focusing on their collective symmetric subspace, we develop codes with octahedral symmetry capable of correcting errors up to second order in angular momentum operators. These errors include the most physically relevant noise sources such as microwave control errors and optical pumping. We additionally explore qubit codes that exhibit distance scaling commensurate with the surface code while permitting transversal single-qubit Clifford operations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Rapidly changing radio images

Kinematic illusions in connection with retardation effects involving extragalactic sources with varying microwave output, noting occurrence in quasar 3C 279

Cavaliere, A.↗

Lensless Image Scanner

Image scanner uses moving and stationary parallel slits to produce pictures of visible, infrared, X-ray microwave, or acoustic sources. No lenses or mirrors required. Single detector views all parts of image simultaneously rather than raster making relatively-short exposure times possible. Potential applications of system include medical x-ray imaging.

Schindler, R. A.↗

Temperature Crosstalk Sensitivity of the Kummerow Rainfall Algorithm

Even though the signal source for passive microwave retrievals is thermal emission, retrievals of non-temperature geophysical parameters typically do not explicitly take into account the effects of temperature change on the retrievals. For global change research, changes in geophysical parameters (e.g. water vapor, rainfall, etc.) are referenced to the accompanying changes in temperature. If the retrieval of a certain parameter has a cross-talk response from temperature change alone, the retrievals might not be very useful for climate research. We investigated the sensitivity of the Kummerow rainfall retrieval algorithm to changes in air temperature. It was found that there was little net change in total rainfall with air temperature change. However, there were non-negligible changes within individual rain rate categories.

Spencer, Roy W.↗

Low Ozone over Europe Doesn't Mean the Sky Is Falling, Its Actually Rising

Data Sources: NASA Aura Microwave Limb Sounder (MLS) (O3 profiles and columns), NASA Global Modeling Initiative (GMI) Chemistry and Transport Model (calculated O3depletion), and MERRA Tropopause Heights. Technical Description of Figures: The left graphics show MLS northern hemisphere stratospheric column ozone on Feb. 1, 2016. Very low columns are seen over the UK and Europe (<225 DU, inside dashed circle). The lower graphic shows the GMI-calculated O3 depletion. It's very small, suggesting the low O3 does not indicate significant depletion. The right graphics show how the high tropopause height in this region explains the observed low ozone. The lower panel shows that the high tropopause on Feb. 1 lifts the O3 profile compared to a typical profile found earlier in winter. This motion lifts the profile to lower pressures thus reducing the total column. The GMI Model shows only 4 Dobson Units (DU) of O3 depletion even though the column is more than 100 DU lower than one month earlier. Scientific significant and societal relevance: To quantitatively understand anthropogenic impacts to the stratospheric ozone layer, we must be able to distinguish between low ozone caused by ozone depleting substances and that caused by natural dynamical variability in the atmosphere. Observations and realistic simulations of atmospheric composition are both required in order to separate natural and anthropogenic ozone variability.

Stratospheric↗

HYDRAFloods Near Real-Time Mapping of Flood Events Using Multiple Satellite Sensors

Information about inundated areas is critical for distributing aid and resources in flood emergency response operations. Conventional methods of monitoring floods, like gauge based observations and reports from local authorities, provide very detailed and accurate information about flood depth and location. However, the geographic coverage of these point-based observations is limited and delays are common. Satellite-based images can help address these challenges, providing near real-time flood extent information over large areas of coverage. The Hydrological Remote Sensing Analysis of Floods (HYDRAFloods) tool, currently being developed by SERVIR-Mekong in collaboration with the Myanmar Department of Disaster Management, is one such example. Generating flood maps, even from satellite imagery, is challenging, given the many disparate sources of information. HYDRAFloods leverages the most recently available remotely sensed data acquired by multiple satellite platforms to automate the creation of daily flood maps. Through combining multiple satellite sources, including optical, microwave, and synthetic aperture radar datasets, near real-time flood maps with reduced cloud impact and increased satellite observations can be generated for use by disaster managers.

Nauman, Claire↗

120-GHz HEMT Oscillator With Surface-Wave-Assisted Antenna

Two monolithic microwave integrated circuits (MMICs) have been designed and built to function together as a source of electromagnetic radiation at a frequency of 120 GHz. One of the MMICs is an oscillator and is the highest-power 120-GHz oscillator reported thus far in the literature. The other MMIC is an end-fire antenna that radiates the oscillator signal. Although these MMICs were constructed as separate units and electrically connected with wire bonds, future oscillator/ antenna combinations could readily be fabricated as monolithic integrated units. Such units could be used as relatively high-power solid-state microwave sources in diverse applications that include automotive radar, imaging, scientific instrumentation, communications, and radio astronomy. As such, these units would be attractive alternatives to vacuum-tube oscillators, which are still used to obtain acceptably high power in the frequency range of interest. The oscillator (see figure) includes a high-electron-mobility transistor (HEMT), with gate-periphery dimensions of 4 by 37 m, in a common-source configuration. The series feedback element of the oscillator is a grounded coplanar waveguide (CPW) at the source. The HEMT is biased for class-A operation (meaning that current is conducted throughout the oscillation cycle) to maximize the output power of the oscillator. Input and output impedance-matching circuit elements are designed to maximize output power and to establish the conditions needed for oscillation. The design of the antenna takes advantage of surface waves, which, heretofore, have been regarded as highly disadvantageous because they can leak power and degrade the performances of antennas that have not been designed to exploit them. Measures taken to suppress surface waves have included complex machining of circuit substrates and addition of separate substrates. These measures are difficult to implement in standard MMIC fabrication processes. In contrast, because the design of the present antenna eliminates the need to suppress surface waves, the fabrication of the antenna is fully compatible with standard MMIC fabrication processes.

Samoska, Lorene↗

Slotted antenna waveguide plasma source

A high density plasma generated by microwave injection using a windowless electrodeless rectangular slotted antenna waveguide plasma source has been demonstrated. Plasma probe measurements indicate that the source could be applicable for low power ion thruster applications, ion implantation, and related applications. This slotted antenna plasma source invention operates on the principle of electron cyclotron resonance (ECR). It employs no window and it is completely electrodeless and therefore its operation lifetime is long, being limited only by either the microwave generator itself or charged particle extraction grids if used. The high density plasma source can also be used to extract an electron beam that can be used as a plasma cathode neutralizer for ion source beam neutralization applications.

Foster, John↗

Characterization of the Polarization Beam Response of SPT-3G Using Point Sources

Precise measurements of cosmic microwave background (CMB) polarization require rigorous control of instrumental systematics. For the South Pole Telescope's third-generation camera (SPT-3G), which observes in three bands centered near 95, 150, and 220 GHz, accurate beam characterization is critical for interpreting the polarized mm-wave sky. We present direct measurements of SPT-3G's polarized beam response from observations of 100 bright extragalactic point sources. Previous SPT-3G power spectrum analyses introduced a phenomenological parameter, $β_{\rm pol}$, to describe the polarization preserved in beam sidelobes, and found evidence for significant depolarization from the requirement of inter-frequency polarization power spectrum consistency. Our direct measurements yield $β_{\rm pol}=0.89\pm0.10$ at 95 GHz, $1.08\pm0.10$ at 150 GHz, and $0.90\pm0.22$ at 220 GHz, indicating minimal sidelobe depolarization. We validate these results with systematic tests of posterior sampling versus bootstrap resampling, real-space versus Fourier-space analysis, temperature-to-polarization leakage handling, covariance determination, and source selection. Compared to values inferred from previous cosmological analyses, our results differ by an effective $1.3σ$. This apparent discrepancy is model dependent, because the point source analysis derives much of its $β_{\rm pol}$ constraining power from higher multipoles than the power spectrum analysis. These measurements therefore admit three explanations for the frequency-dependent residuals observed in the power spectrum analysis: a statistical fluctuation, the need for more sophisticated polarized beam models, or systematics other than beam depolarization.

de Haan, T. [KEK, Tsukuba]↗

High temperature acoustic and hybrid microwave/acoustic levitators for materials processing

The physical acoustics group at the Jet Propulsion Laboratory developed a single mode acoustic levitator technique for advanced containerless materials processing. The technique was successfully demonstrated in ground based studies to temperatures of about 1000 C in a uniform temperature furnace environment and to temperatures of about 1500 C using laser beams to locally heat the sample. Researchers are evaluating microwaves as a more efficient means than lasers for locally heating a positioned sample. Recent tests of a prototype single mode hybrid microwave/acoustic levitator successfully demonstrated the feasibility of using microwave power as a heating source. The potential advantages of combining acoustic positioning forces and microwave heating for containerless processing investigations are presented in outline form.

Barmatz, Martin↗