Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “microwave oscillators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

QCD axion: Some like it hot

We compare the quantum chromodynamics (QCD) axion phase-space distribution from unitarized next-to-leading order chiral perturbation theory with the one extracted from pion-scattering data. We derive a robust bound by confronting momentum-dependent Boltzmann equations against up-to-date observations of the cosmic microwave background, of the baryonic acoustic oscillations and of primordial abundances. These datasets imply 𝑚 𝑎 ≤ 0.16 eV for the 95% credible interval, i.e., ∼ 30% stronger bound than what previously found. We present forecasts using dedicated likelihoods for future cosmological surveys and the sphaleron rate from unquenched lattice QCD.

79 ASTRONOMY AND ASTROPHYSICS↗

Resonant-tunnelling diode oscillator using a slot-coupled quasioptical open resonator

A resonant-tunneling diode has oscillated at X-band frequencies in a microwave circuit consisting of a slot antenna coupled to a semiconfocal open resonator. Coupling between the open resonator and the slot oscillator improves the noise-to-carrier ratio by about 36 dB relative to that of the slot oscillator alone in the 100-200 kHz range. A circuit operating near 10 GHz has been designed as a scale model for millimeter- and submillimeter-wave applications.

Stephan, K. D.↗

Cool dark sector, concordance, and a low σ 8

We investigate a cosmological model in which a fraction of the dark matter is atomic dark matter (ADM). This ADM consists of dark versions of the electron and of the proton, interacting with each other and with dark photons just as their light sector versions do, but interacting with everything else only gravitationally. We find constraints given current cosmic microwave background (CMB) and baryon acoustic oscillation (BAO) data, with and without an H 0 prior, and with and without enforcing a big bang nucleosynthesis consistent helium abundance. We find that, at low dark photon temperature, one can have consistency with BAO and CMB data, with a fraction of dark matter that is ADM (f adm ) as large as ~0.1 . Such a large f adm leads to a suppression of density fluctuations today on scales below about 60 Mpc that may be of relevance to the σ 8 tension. Our work motivates calculation of nonlinear corrections to matter power spectrum predictions in the ADM model. Here, we forecast parameter constraints to come from future ground-based CMB surveys, and find that if ADM is indeed the cause of the σ 8 tension, the influence of the ADM, primarily on CMB lensing, will likely be detectable at high significance.

79 ASTRONOMY AND ASTROPHYSICS↗

SPT-3G D1: Axion early dark energy with CMB experiments and DESI observations

We present the most up-to-date constraints on axion early dark energy (AEDE) from cosmic microwave background (CMB) and baryon acoustic oscillation (BAO) measurements. In particular, we assess the impact of data from ground-based CMB experiments, the South Pole Telescope (SPT) and the Atacama Cosmology Telescope (ACT)—both with and without Planck—on constraints on AEDE. We also highlight the impact that BAO information from the Dark Energy Spectroscopic Instrument (DESI) has on these constraints. From CMB data alone, we do not find statistically significant evidence for the presence of AEDE, and we find only moderate reduction in the Hubble tension. From the latest SPT data alone, we find the maximal fractional contribution of AEDE to the cosmic energy budget is f EDE < 0.12 at 95% confidence level (CL), and the Hubble tension between the SPT and Supernovae, H0, for the Equation of State of Dark Energy (SH0ES) results is reduced to the 2.3 σ level. When combining the latest SPT, ACT, and Planck datasets, we find f EDE < 0.070 at 95% CL and the Hubble tension at the 3.6 σ level. In contrast, adding DESI data to the CMB datasets results in mild preference for AEDE and, in some cases, non-negligible reduction in the Hubble tension. From SPT + DESI , we find f EDE = 0.08 1 - 0.052 + 0.037 at 68% CL, and the Hubble tension reduces to 1.5 σ . From the combination of DESI with all three CMB experiments, we get f EDE = 0.05 5 - 0.047 + 0.024 at 68% CL and a weak preference for AEDE over Λ CDM . This data combination, in turn, reduces the Hubble tension to 2.6 σ . We highlight that this shift in parameters when adding the DESI dataset is a manifestation of the discrepancy currently present between DESI and CMB experiments in the concordance model Λ CDM .

Khalife, A. R. [Paris, Inst. Astrophys.] (ORCID:00↗

The Pantheon+ Analysis: Cosmological Constraints

We present constraints on cosmological parameters from the Pantheon+ analysis of 1701 light curves of 1550 distinct Type Ia supernovae (SNe Ia) ranging in redshift from z = 0.001 to 2.26. This work features an increased sample size from the addition of multiple cross-calibrated photometric systems of SNe covering an increased redshift span, and improved treatments of systematic uncertainties in comparison to the original Pantheon analysis, which together result in a factor of 2 improvement in cosmological constraining power. For a flat ΛCDM model, we find Ω M = 0.334 ± 0.018 from SNe Ia alone. For a flat w 0 CDM model, we measure w 0 = –0.90 ± 0.14 from SNe Ia alone, H 0 = 73.5 ± 1.1 km s –1 Mpc –1 when including the Cepheid host distances and covariance (SH0ES), and w 0 = $-{0.978}_{-0.031}^{+0.024}$ when combining the SN likelihood with Planck constraints from the cosmic microwave background (CMB) and baryon acoustic oscillations (BAO); both w 0 values are consistent with a cosmological constant. We also present the most precise measurements to date on the evolution of dark energy in a flat w 0 w a CDM universe, and measure w a = $-{0.1}_{-2.0}^{+0.9}$ from Pantheon+ SNe Ia alone, H 0 = 73.3 ± 1.1 km s –1 Mpc –1 when including SH0ES Cepheid distances, and w a = $-{0.65}_{-0.32}^{+0.28}$ when combining Pantheon+ SNe Ia with CMB and BAO data. Finally, we find that systematic uncertainties in the use of SNe Ia along the distance ladder comprise less than one-third of the total uncertainty in the measurement of H 0 and cannot explain the present "Hubble tension" between local measurements and early universe predictions from the cosmological model.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Tuning Concept for Resonant Cavities

Deviations from resonance detected by sampling phases. Automatic tuner feedback control system derives error signal from E and H plane probe signals. Control objective to maintain phase difference between E and H at 90 degrees. Technique estimated to sensitive to fractional frequency deviation of about 5 X 10-16 and applicable not only to masers but also other microwave elements, including klystrons, general purpose oscillators, and frequency standards.

Sydnor, R. L.↗

Limits to the Stability of Phase Transfer from Ground to Space

An alternative to having a primary frequency standard on board a spacecraft is to phase lock a simple oscillator on the spacecraft to a microwave tone transmitted from the ground. The received tone is transponded and rebroadcast to the ground. The round trip phase is measured, and used to correct for effects on time scales longer than the round trip light travel time. This method is used with the TDRSS relay satellites, and will be used for the Japanese space VLBI mission VSOP. There are several sources of error introduced by this process. The most important error source is a loss of the on board standard for all times that the satellite is out of contact with a ground tracking station. The fractional loss will be greater than 10% for almost any orbit, even with a network of several ground tracking stations, and it will be considerably worse for a low earth orbit. Only a geostationary orbit can eliminate this problem. Another error source is connected to the previous one. Round trip phase tracking can remove, after the fact, link effects during a tracking pass on time scales greater than the round trip light travel time. However, there will be a jump in the spacecraft clock when multiple passes are connected (e.g. when the spacecraft is reacquired after passing out of sight). These jumps will be equal in magnitude (except for a geometrical factor) to the accuracy with which the spacecraft orbit is known. With a GPS receiver and GPS-like beacon on a spacecraft, the orbit can be known to a few cm, giving timing jumps on the order of 100 picoseconds. Even with a geostationary orbit, these jumps would occur any time the link was interrupted due to mechanical or electrical problems.

Linfield, Roger P.↗

Narrow-Band WGM Optical Filters With Tunable FSRs

Optical resonators of the whispering-gallery-mode (WGM) type featuring DC-tunable free spectral ranges (FSRs) have been demonstrated. By making the FSR tunable, one makes it possible to adjust, during operation, the frequency of a microwave signal generated by an optoelectronic oscillator in which an WGM optical resonator is utilized as a narrow-band filter.

Mohageg, Makan↗

Nine-Year Wilkinson Microwave Anisotropy Probe (WMAP) Observations: Cosmological Parameter Results

We present cosmological parameter constraints based on the final nine-year Wilkinson Microwave Anisotropy Probe (WMAP) data, in conjunction with a number of additional cosmological data sets. The WMAP data alone, and in combination, continue to be remarkably well fit by a six-parameter Lambda-CDM model. When WMAP data are combined with measurements of the high-l cosmic microwave background anisotropy, the baryon acoustic oscillation scale, and the Hubble constant, the matter and energy densities Omega(sub b)h(exp 2), Omega(sub c)h(exp 2)and Omega(sub Lambda), are each determined to a precision of approx. 1.5%. The amplitude of the primordial spectrum is measured to within 3%, and there is now evidence for a tilt in the primordial spectrum at the 5 sigma level, confirming the first detection of tilt based on the five-year WMAP data. At the end of the WMAP mission, the nine-year data decrease the allowable volume of the six-dimensional Lambda-CDM parameter space by a factor of 68,000 relative to pre-WMAP measurements. We investigate a number of data combinations and show that their Lambda-CDM parameter fits are consistent. New limits on deviations from the six-parameter model are presented, for example: the fractional contribution of tensor modes is limited to r < 0.13 (95% CL); the spatial curvature parameter is limited to Omega(sub kappa) = (0.0027 (sub +0.0039) (sup −0.0038;) the summed mass of neutrinos is limited to Sigma M(sub nu) < 0.44 eV (95% CL); and the number of relativistic species is found to lie within N(sub eff) = 3.84 +/- 0+/-40, when the full data are analyzed. The joint constraint on N(sub eff) and the primordial helium abundance, Y(sub He), agrees with the prediction of standard big bang nucleosynthesis. We compare recent Planck measurements of the Sunyaev-Zel'dovich effect with our seven-year measurements, and show their mutual agreement. Our analysis of the polarization pattern around temperature extrema is updated. This confirms a fundamental prediction of the standard cosmological model and provides a striking illustration of acoustic oscillations and adiabatic initial conditions in the early universe.

cosmology↗

Recent progress in opto-electronic oscillator

The optoelectronic oscillator (OEO) is a unique device based on photonics techniques to generate highly spectrally pure microwave signals [1]. The development of the OEO was motivated by the need for high performance oscillators in the frequency range larger than 10 GHz, where conventional electronic oscillators have a number of limitations. These limitations typically stem from the product of fQ, where f is the oscillator frequency and Q is the quality factor of the resonator in the oscillator. In conventional resonators, whether electromagnetic or piezoelectric, this product is usually a constant. Thus, as the oscillator frequency is pushed higher, the quality factor degrades, resulting in degradation of the phase noise of the oscillator. An approach to mitigate the problem is to start with a very high quality signal in the 5 to 100 MHz range generated by a quartz oscillator and multiply the frequency to achieve the desired microwave signal. Here again, frequency multiplication also results in an increase of the phase noise by a factor of 2010gN, where N is the multiplication factor.

opto-electronic oscillators↗

Electro-optic transduction in silicon via gigahertz-frequency nanomechanics

Interfacing electronics with optical fiber networks is key to the long-distance transfer of classical and quantum information. Piezo-optomechanical transducers enable such interfaces by using gigahertz-frequency acoustic vibrations as mediators for converting microwave photons to optical photons via the combination of optomechanical and piezoelectric interactions. However, despite successful demonstrations, efficient quantum transduction remains out of reach due to the challenges associated with hybrid material integration and increased loss from piezoelectric materials when operating in the quantum regime. Here, we demonstrate an alternative approach in which we actuate 5-GHz phonons in a conventional silicon-on-insulator platform. In our experiment, microwave photons resonantly drive a phononic crystal oscillator via the electrostatic force realized in a charge-biased narrow-gap capacitor. The mechanical vibrations are subsequently transferred via a phonon waveguide to an optomechanical cavity, where they transform into optical photons in the sideband of a pump laser field. Operating at room temperature and atmospheric pressure, we measure a microwave-to-optical photon conversion efficiency of 1.72±0.14×10 −7 in a 3.3 MHz bandwidth. Our results mark a stepping stone towards quantum transduction with integrated devices made from crystalline silicon, which promise efficient high-bandwidth operation and integration with superconducting qubits. Additionally, the lack of need for piezoelectricity or other intrinsic nonlinearities makes our approach applicable to a wide range of materials for potential applications beyond quantum technologies.

42 ENGINEERING↗

High-Temperature Superconducting/Ferroelectric Structures for Tunable Microwave Components

At the NASA Lewis Research Center, ferroelectric films, such as SrTiO3 and Ba(x)Sr(1-x)TiO3, are being used in conjunction with YBa2Cu3O(7-delta) high-temperature superconducting (HTS) thin films to fabricate tunable microwave components, such as filters, varactors, and local oscillators. These structures capitalize on the variation of the dielectric constant of the ferroelectric film upon the application of a dc electric field as well as on the low microwave losses exhibited by the high-temperature superconducting films relative to their conventional conductor counterparts. (For example, the surface resistance for a YBa2Cu3O(7-delta) thin film at 10 GHz and 77 K is more than two orders of magnitude lower than that of copper at the same frequency and temperature.) SrTiO3 and Ba(x)Sr(1-x)TiO3 films are used because their crystal structure and lattice parameters are similar to those of YBa2Cu3O(7-delta), thus enabling the growth of highly textured YBa2Cu3O(7-delta) films with high critical current densities on the underlying ferroelectric film, or alternatively, of highly textured ferroelectric film on the underlying YBa2Cu3O(7-delta) film. Our efforts have been concentrated so far in determining the deposition parameters required for optimal ferroelectric thin-film growth (i.e., maximum tunability and lowest loss) and in investigating different varactor configurations to determine which geometry is the most advantageous in terms of tunability, losses, and required bias for a given communication application. For example, we have observed that for optimized SrTiO3 films in a parallel plate capacitor, tunabilities of up to 47 percent and dissipation losses (tan d) of 0.05 are attainable at 1 MHz , 80 K, and within the 0- to 5-V bias range. In contrast, for an interdigital configuration, tunabilities of up to 70 percent and tan d ranging from 0.015 to 0.001 (depending on bias) have been observed at 1 MHz and 77 K within the 0- to 100-V bias range. Efforts are underway to use these results in developing tunable receiver front-end preselect filters as well as in low-phase noise, tunable local oscillators for K-band applications. These components represent a hitherto unavailable technology to meet the stringent performance requirements of foreseeable satellite and wireless communication systems (e.g., bandwidth, in-band insertion losses, out-of-band rejection, and noise, amongst others) in a more advantageous fashion than with currently available technology (e.g., dielectric-filled cavity and waveguide filters, and dielectric resonator oscillators). Prototypes of high-temperature superconducting/ferroelectric tunable components such as a low-phase noise K-band local oscillator, a preselect C-band filter, and a low-loss K-band phase shifter are under development at NASA Lewis.

Miranda, Felix A.↗

Local oscillator distribution using a geostationary satellite

A satellite communication system suitable for distribution of local oscillator reference signals for a widely spaced microwave array has been developed and tested experimentally. The system uses a round-trip correction method of the satellite This experiment was carried out using Telstar-5, a commercial Ku-band geostationary satellite. For this initial experiment, both earth stations were located at the same site to facilitate direct comparison of the received signals. The local oscillator reference frequency was chosen to be 300MHz and was sent as the difference between two Ku-band tones. The residual error after applying the round trip correction has been measured to be better than 3psec for integration times ranging from 1 to 2000 seconds. For integration times greater then 500 seconds, the system outperforms a pair of hydrogen masers with the limitation believed to be ground-based equipment phase stability. The idea of distributing local oscillators using a geostationary satellite is not new; several researchers experimented with this technique in the eighties, but the achieved accuracy was 3 to 100 times worse than the present results. Since substantially and the performance of various components has improved. An important factor is the leasing of small amounts of satellite communication bandwidth. We lease three 100kHz bands at approximately one hundredth the cost of a full 36 MHz transponder. Further tests of the system using terminal separated by large distances and comparison tests with two hydrogen masers and radio interferometry is needed.

hydrogen maser↗

Evidence for low-frequency waves of tropical rainfall inferred from microwave brightness temperature

Evidence for the 30-60-day oscillation was found in the rainfall data that were retrieved from Special Sensor Microwave/Imager (SSM/I) brightness temperatures from January to December 1989. Spectral analysis of daily rainfall showed that the strongest rainfall oscillations were located from 5 deg S to 5 deg N and extend from about 60 deg E to 180 deg. The oscillation propagated eastward at a speed of approximately 4 m/s along the equatorial Indian-western Pacific Ocean area. Northward propagation at a speed of about 1.5 m/s was also detected from 15 deg S to 30 deg N over the Indian Ocean between early May and late July.

Hong, YE↗

Latched detection of zeptojoule spin echoes with a kinetic inductance parametric oscillator

When strongly pumped at twice their resonant frequency, nonlinear resonators develop a high-amplitude intracavity field, a phenomenon known as parametric self-oscillations. The boundary over which this instability occurs can be extremely sharp and thereby presents an opportunity for realizing a detector. Here, we operate such a device based on a superconducting microwave resonator whose nonlinearity is engineered from kinetic inductance. The device indicates the absorption of low-power microwave wavepackets by transitioning to a self-oscillating state. Using calibrated pulses, we measure the detection efficiency to zeptojoule energy wavepackets. We then apply it to measurements of electron spin resonance, using an ensemble of 209 Bi donors in silicon that are inductively coupled to the resonator. We achieve a latched readout of the spin signal with an amplitude that is five hundred times greater than the underlying spin echoes.

42 ENGINEERING↗

System-on-Chip approach microwave diagnostics development for burning plasma

System-on-chip (SoC) millimeter wave integrated circuit technology has been developed and employed in chip heterodyne radiometers in Electron Cyclotron Emission Imaging (ECEI) and Microwave Imaging Reflectometer (MIR) on the DIII-D tokamak for 2D electron temperature and density fluctuation diagnostics. The W-band (75-110 GHz) ECEI system has been employed with 20 poloidal horn receiver modules with customized monolithic integrated circuit chips and internal local oscillator coupling path. The new SoC approach demonstrates > 30 dB additional gain on the receiver and 95% electronics noise suppression compared to the previous Schottky diode mixer array . An F-band (110-140 GHz) receiver chip has been developed to measure MHD and turbulence behavior on the DIII-D high-field side, such as Alfven eigenmodes. Furthermore, it can image pedestal structure evolution on fusion facilities with stronger magnetic fields, such as ASDEX-U, EAST, HL-2M, and LHD. The F-band chip performance has been tested in the laboratory. Also, V-band (55-75 GHz) transmitter and receiver modules (55-75 GHz) have been developed for DIII-D and NSTX-U Furthermore, microwave Imaging Reflectometer (MIR) application suitability for 2D density fluctuation imaging on the pedestal region.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗