Sensitivity of thermodynamic profiles retrieved from ground-based microwave and infrared observations to additional input data from active remote sensing instruments and numerical weather prediction models

Accurate and continuous estimates of the thermodynamic structure of the lower atmosphere are highly beneficial to meteorological process understanding and its applications, such as weather forecasting. In this study, the Tropospheric Remotely Observed Profiling via Optimal Estimation (TROPoe) physical retrieval is used to retrieve temperature and humidity profiles from various combinations of input data collected by passive and active remote sensing instruments, in situ surface platforms, and numerical weather prediction models. Among the employed instruments are microwave radiometers (MWRs), infrared spectrometers (IRSs), radio acoustic sounding systems (RASSs), ceilometers, and surface sensors. TROPoe uses brightness temperatures and/or radiances from MWRs and IRSs, as well as other observational inputs (virtual temperature from the RASS, cloud-base height from the ceilometer, pressure, temperature, and humidity from the surface sensors) in a physical iterative retrieval approach. This starts from a climatologically reasonable profile of temperature and water vapor, with the radiative transfer model iteratively adjusting the assumed temperature and humidity profiles until the derived brightness temperatures and radiances match those observed by the MWR and/or IRS instruments within a specified uncertainty, as well as within the uncertainties of the other observations, if used as input. In this study, due to the uniqueness of the dataset that includes all the above-mentioned sensors, TROPoe is tested with different observational input combinations, some of which also include information higher than 4 km above ground level (a.g.l.) from the operational Rapid Refresh numerical weather prediction model. These temperature and humidity retrievals are assessed against independent collocated radiosonde profiles under non-cloudy conditions to assess the sensitivity of the TROPoe retrievals to different input combinations.

54 ENVIRONMENTAL SCIENCES↗

Emergent properties of magnons coupled to microwave photons (Final Technical Report)

Studying the emergent properties of hybrid quantum material platforms holds great promise for advancing quantum technologies and transforming our ability to control quantum mechanical interactions. A key development in recent years is the recognition that magnons – the elementary quanta of spin waves – can serve as fundamental building blocks in quantum systems. Understanding the mechanisms behind the generation and control of hybrid quasiparticles based on magnons could pave the way for engineering new materials for quantum coherent processing and quantum computing. This research project focused on the precise control of light-matter interactions in magnetic hybrid systems and nanostructures, where light is carried by microwave photons and matter by magnons in engineered magnetic metamaterials. Furthermore, we investigated hybridized magnon interactions in magnetic nanostructures and devices. To this end, the project has developed new measurement techniques and systematically studied novel material systems for efficient magnon-photon coupling. A key focus was uncovering the fundamental mechanisms governing magnon-photon and magnon-phonon interactions – critical for utilizing magnons as coherent information transducers between carriers. Specifically, this research addressed: 1. Investigate the dispersion and collective properties of magnon hybrid systems in new material systems. 2. Develop magnonic hybrids with non-zero wavevectors and achieve effective control of magnon-polariton properties through engineered magnonic behaviors. 3. Determine how spin-orbit torques interact with electromagnetic fields in the strong coupling regime. This work generated new insights into the physics of magnonic hybrid systems and their emergent properties by broadening the range of material platforms and measurement techniques used to study magnon-photon and magnon-magnon coupling. The findings deepen our understanding of magnon-polaritons and lay the groundwork for novel spintronic devices with potential applications in quantum information science.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High frequency gravitational wave sensing with superconducting microwave cavities

A promising way to probe physics beyond the Standard Model is to search for gravitational wave (GW) signals at high frequencies where known astrophysical sources can not obscure the signal. Similar to the search for dark matter, microwave cavity resonators can be used to detect faint effects from GWs. We will report on the progress of our project to operate such a detector and highlight improvements we are planning in the future. This includes quantum enhancement techniques like vacuum squeezing which will allow future detectors to operate beyond the standard quantum limit.

Marconato, Giovanni [Hamburg U.]↗

Frequency-Selectable Laser Source for Cosmic Microwave Background Experiments

Cosmic Microwave Background (CMB) experiments measure remnant radiation from the early universe and use that data to determine fundamental properties of the universe. We can constrain key parameters, such as \textit{r}, the cosmic tensor-to-scalar ratio, and $N_\text{eff}$, the effective number of relativistic species, by analyzing the CMB power spectra. Improving our measurements of the CMB requires improving our instrument systematics, one of the most important of which is detector bandpass. Current experiments use a Fourier Transform Spectrometer (FTS) to measure bandpass. However, the FTS is systematics limited, and cannot achieve the accuracy needed to make improved CMB measurements. For this reason, we are developing a new instrument, the Frequency-Selectable Laser Source (FLS) to decrease the uncertainty in bandpass by an order of magnitude. In this paper, we describe work completed to support the version 2 upgrade to the FLS. Using ray-tracing software, we modeled the FLS optics to set physical tolerances for the new design. We also discuss the laser calibration, and future work to be completed in further development of the FLS upgrade.

Rosen-Turits, Gabriel M. [Fermilab]↗

Mechanical Actuation Mechanism Design for Cryogenic Microwave Cavities in Axion Dark Matter Searches

Resonant Microwave Cavities are placed in a strong magnetic field at cryogenic temperatures (~.1K) in order to try to convert axions into detectable photons. A major challenge is to tune the cavity to allow no interference with the desired environment used for the experiment, which enables the system to operate near absolute zero and maintain superconductivity, thereby reducing noise as much as possible. My project focuses on developing and testing a low-thermal-conductivity gear reduction system with a 1000:1 ratio for cavity tuning. This gear system could significantly improve the thermal and electromagnetic interference of the tuning mechanism, helping ADMX scan for axions more accurately.

Ortega, Giancarlo [Marquette U.; Fermilab]↗

Broad frequency tuning of a Nb$_{3}$Sn superconducting microwave cavity for dark matter searches

We demonstrate a novel broad-frequency tuning mechanism for superconducting microwave cavities designed for dark matter searches. Using a Nb$_3$Sn-coated cigar-shaped cavity operating at approximately 9 GHz, we achieve continuous frequency tuning exceeding 1 GHz by mechanically separating the two cavity halves: a "tuning-by-opening" technique. Finite-element method simulations predict that radiative losses do not degrade the quality factor even for large openings, as a closed cavity with an intrinsic quality factor of $10^7$ maintains this value for apertures up to 9 mm, corresponding to a tuning range from 9.0 to 7.5 GHz. Experimental validation using both copper ring spacers and a continuous sliding mechanism confirms $Q_0$ values exceeding the dark matter quality factor across the entire explored frequency range, despite mechanical imperfections and film non-uniformities. This tuning approach avoids inserting elements into the resonant volume, making it particularly suitable for high-Q superconducting cavities in axion haloscope experiments and readily applicable to REBCO-based implementations capable of operating in multi-tesla magnetic fields.

Maiello, D. [Padua U.; INFN, Padua] (ORCID:0009000↗

Uniform field in microwave cavities through the use of effective magnetic walls

Wire medium (WM) resonators have emerged as a promising realization for plasma haloscopes—devices designed to detect axions, a potential component of dark matter. Key factors influencing the detection probability include cavity volume, resonance quality factor, and form factor. While the form factor has been explored for resonant frequency tuning, its optimization for axion detection remains unexplored. Here, in this work, we present an approach to significantly enhancing the form factor of WM plasma haloscopes. By shifting the metal walls of the resonator by a quarter wavelength, we effectively convert an electric wall boundary condition into a magnetic wall one, allowing for an almost uniform mode. Theoretical analysis and numerical simulations confirm that this modification improves the electric field profile and boosts the form factor, while also slightly enhancing the quality factor. We validate these findings through experimental results from two prototype resonators: one with a standard geometry and another with a quarter-wave air gap between the WM and the walls. Additionally, our method provides a simple way to control the field profile within WM cavities, which can be explored for further applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microwave Catalysis for Process Intensified Modular Production of Carbon Nanomaterials from Natural Gas

The objective of this project was to develop a novel, low-cost process intensified modular process to directly convert flare gas or stranded gas to carbon nanomaterials and co-product hydrogen (H 2 ) with high conversion, selectivity, and stability. The proposed project was based on our exciting exploratory research on a patent pending technology for one-step conversion of natural gas to carbon nanotubes (CNTs) and carbon fibers (CNFs) without emitting CO 2 : CH 4 → H 2 + C (CNT, Carbon Fibers).

03 NATURAL GAS↗

Plasma confinement state classification via FPP relevant microwave diagnostics

We present a parsimonious and robust machine learning approach for identifying plasma confinement states in fusion power plants (FPPs) where reliable identification of the low-confinement and high-confinement regimes is critical for safe and efficient operation. Unlike research-oriented devices, FPPs must operate with a severely constrained set of diagnostics. To address this challenge, we demonstrate that a minimalist model, using only electron cyclotron emission (ECE) signals, can achieve accurate and reliable state classification. ECE provides electron temperature profiles without the engineering or survivability issues of in-vessel probes, making it a primary candidate for FPP-relevant diagnostics. Our framework employs ECE as input, extracts features using radial basis functions, and applies a gradient boosting classifier, achieving a test accuracy of 96% (correct predictions). Robustness analysis and feature importance analyzes confirm the approach’s reliability. These results demonstrate that state-of-the-art performance is attainable from a restricted diagnostic set, paving the way for minimalist yet resilient plasma control architectures for FPPs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗