Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “microfluidic cell”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Aggregation‐Induced Stimulated Emission of 100% Dye Microspheres

Dyes with aggregation-induced emission (AIE) properties have gained interest due to their bright luminescence in solid-state aggregates. While fluorescence from AIE dyes is widely exploited, relatively little is known about aggregation-induced stimulated emission. Here, stimulated emission of tetraphenylethene (TPE)-based organoboron AIE dyes, TPEQBN, in thin films and in microcavity lasers is investigated. Using femtosecond pump–probe spectroscopy, gain coefficients up to 230 cm -1 at 500 nm are measured. Using rate equations, concentration- and pump-dependent gain dynamics as well as laser build-up dynamics are analyzed. During laser oscillation, radiative stimulated emission allows high instantaneous quantum yield greater than 90% to be achieved. Solid-state microspheres made of 100% AIE dyes are fabricated via microfluidic emulsion and solvent evaporation method. Coupled with high gain and high refractive index of 1.76, microspheres as small as 2 µm in diameter show lasing by nanosecond pumping with a threshold of ≈10 pJ µm –2 . Polymer coated, but not bare, microspheres are internalized by live cells and generate narrowband cavity-mode emission from within the cytoplasm. This work shows the potential of AIE dyes as laser materials.

36 MATERIALS SCIENCE↗

Beyond BioSentinel: Iterative Development of Automated Microfluidics

NASA Ames has flown a series of Bio-CubeSats that performed biology experiments supported by automated fluidic systems. Since Genesat-1 in 2006, these payloads have increased in complexity and functionality, building upon previous successes, and applying lessons learned. BioSentinel was the most recent of this series, launched into heliocentric orbit onboard Artemis-1 in 2022. This presentation will discuss how the fluidic technology developed for these Bio-CubeSat missions, including the multi-layer polycarbonate manifolds at the heart of the BioSentinel BioSensor, have spurred the development of several additional projects. Most directly is the modified BioSensor that will be a part of LEIA, which will perform its Lunar biology experiment onboard a Commercial Lunar Payload Services lander. Several search-for-life manifolds have been designed to prepare samples from icy moons for downstream analyses. Two early career Polaris projects are developing fluidics to perform genetic sequencing on samples from multigenerational cell culture and to extract and quantify target miRNAs to support astronaut radiation health assessment. Improving the readiness of these systems has been accelerated by adopting the established flight heritage and microgravity-compatibility of the Bio-CubeSat fluidic hardware and designs, while focusing development efforts on the integration of novel functionalities and components.

microfluidics↗

Sharp front tracking with geometric interface reconstruction

Here, this paper presents a novel sharp front-tracking method designed to address limitations in classical front-tracking approaches, specifically their reliance on smooth interpolation kernels and extended stencils for coupling the front and fluid mesh. In contrast, the proposed method employs exclusively sharp, localized interpolation and spreading kernels, restricting the coupling to the interfacial fluid cells–those containing the interface/front. This localized coupling is achieved by integrating a divergence-preserving velocity interpolation method with a piecewise parabolic interface calculation (PPIC) and a polyhedron intersection algorithm to compute the indicator function and local interface curvature. Surface tension is computed using the Continuum Surface Force (CSF) method, maintaining consistency with the sharp representation. Additionally, we propose an efficient local roughness smoothing implementation to account for surface mesh undulations, which is easily applicable to any triangulated surface mesh. Building on our previous work, the primary innovation of this study lies in the localization of the coupling for both the indicator function and surface tension calculations. By reducing the interface thickness on the fluid mesh to a single cell, as opposed to the 4–5 cell spans typical in classical methods, the proposed sharp front-tracking method achieves a highly localized and accurate representation of the interface. This sharper representation mitigates parasitic currents and improves force balancing, making it particularly suitable for scenarios where the interface plays a critical role, such as microfluidics, fluid-fluid interactions, and fluid-structure interactions. The proposed method is comprehensively validated and tested on canonical interfacial flow problems, including stationary and translating Laplace equilibria, oscillating droplets, and rising bubbles. The presented results demonstrate that the sharp front-tracking method significantly outperforms the classical approach in terms of accuracy, stability, and computational efficiency. Notably, parasitic currents are reduced by approximately two orders of magnitude and stable results are obtained for parameter ranges where classical front tracking fails to converge.

42 ENGINEERING↗

Proteomic Profiling of Intra-Islet Features Reveals Substructure-Specific Protein Signatures

Despite their diminutive size, islets of Langerhans play a large role in maintaining systemic energy balance in the body. New technologies have enabled us to go from studying the whole pancreas, to isolated whole islets, to partial islet sections, and now to islet substructures isolated from within the islet. Using a microfluidic nanodroplet-based proteomics platform coupled with laser capture microdissection (LCM), we present an in-depth investigation of protein profiles specific to regions within the islet. These regions studied include the vascular tissue containing interface boundary, micro-vascular tissue internal to the islet, isolated endocrine cells, islet sections with vasculature intact, and finally acinar tissue from around the islet. Unique protein signatures observed in the inner vasculature potentially indicate increased innervation and intra-islet neuron-like crosstalk compared to external vasculature. We also demonstrate the utility of these data for isolating localized structure-specific drug-target interactions using existing protein/drug binding databases.

59 BASIC BIOLOGICAL SCIENCES↗

Development of an Autonomous, Dual Chamber Bioreactor for the Growth of 3-Dimensional Epithelial-Stromal Tissues in Microgravity

We are developing a novel, autonomous bioreactor that can provide for the growth and maintenance in microgravity of 3‐D organotypic epithelial‐stromal cultures that require an air‐liquid interface. These complex 3‐D tissue models accurately represent the morphological features, differentiation markers, and growth characteristics observed in normal human epithelial tissues, including the skin, esophagus, lung, breast, pancreas, and colon. However, because of their precise and complex culture requirements, including that of an air‐liquid interface, these 3‐D models have yet to be utilized for life sciences research aboard the International Space Station. The development of a bioreactor for these cultures will provide the capability to perform biological research on the ISS using these realistic, tissue‐like human epithelial‐stromal cell models and will contribute significantly to advances in fundamental space biology research on questions regarding microgravity effects on normal tissue development, aging, cancer, and other disease processes. It will also allow for the study of how combined stressors, such as microgravity with radiation and nutritional deficiencies, affect multiple biological processes and will provide a platform for conducting countermeasure investigations on the ISS without the use of animal models. The technology will be autonomous and consist of a cell culture chamber that provides for air‐liquid, liquid‐liquid, and liquid‐air exchanges within the chambers while maintaining the growth and development of the biological samples. The bioreactor will support multiple tissue types and its modular design will provide for incorporation of add‐on capabilities such as microfluidics drug delivery, media sampling, and in situ biomarker analysis. Preliminary flight testing of the hardware will be conducted on a parabolic platform through NASA's Flight Opportunities Program.

Patel, Zarana S.↗

Coupling Microdroplet-Based Sample Preparation, Multiplexed Isobaric Labeling, and Nanoflow Peptide Fractionation for Deep Proteome Profiling of the Tissue Microenvironment

There is increasing interest in developing in-depth proteomic approaches for mapping tissue heterogeneity in a cell-type-specific manner to better understand and predict the function of complex biological systems such as human organs. Existing spatially resolved proteomics technologies cannot provide deep proteome coverage due to limited sensitivity and poor sample recovery. Herein, we seamlessly combined laser capture microdissection with a low-volume sample processing technology that includes a microfluidic device named microPOTS (microdroplet processing in one pot for trace samples), multiplexed isobaric labeling, and a nanoflow peptide fractionation approach. The integrated workflow allowed us to maximize proteome coverage of laser-isolated tissue samples containing nanogram levels of proteins. We demonstrated that the deep spatial proteomics platform can quantify more than 5000 unique proteins from a small-sized human pancreatic tissue pixel (∼60,000 μm2) and differentiate unique protein abundance patterns in pancreas. Furthermore, the use of the microPOTS chip eliminated the requirement for advanced microfabrication capabilities and specialized nanoliter liquid handling equipment, making it more accessible to proteomic laboratories.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Kinetics and Mechanism of Ce(IV) Phase Transfer by the Neutral Extractants Tributyl Phosphate and N,N -Di(2-ethylhexyl)isobutyramide

Tributyl phosphate and N,N-di(2-ethylhexyl)isobutyramide (DEHiBA) are uranium-selective extractants that could be used to recover low-enriched uranium from commercial used nuclear fuel. The economic viability of liquid-liquid extraction processes for chemical separations depends on both thermodynamic and kinetic considerations. Here we used microfluidic droplet extraction to measure interfacial phase transfer rate constants for the extraction and stripping of Ce(IV), a non-radioactive actinide surrogate. The Damkohler numbers for each system were calculated and the phase transfer processes were determined to be diffusion-limited under all conditions, contrary to prior studies using constant interface stirred cells and single drop methods. A well-extracted 2:1 DEHiBA/Ce(IV) complex in the organic phase was determined from batch distribution studies, suggesting a different extraction mechanism for Ce(IV) compared with poorly extracted Pu(IV). Finally, phase disengagement rates were found to be rapid in both systems, in agreement with other studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Capillary-Driven Flow in Liquid Filaments Connecting Orthogonal Channels

Capillary phenomena plays an important role in the management of product water in PEM fuel cells because of the length scales associated with the porous layers and the gas flow channels. The distribution of liquid water within the network of gas flow channels can be dramatically altered by capillary flow. We experimentally demonstrate the rapid movement of significant volumes of liquid via capillarity through thin liquid films which connect orthogonal channels. The microfluidic experiments discussed provide a good benchmark against which the proper modeling of capillarity by computational models may be tested. The effect of surface wettability, as expressed through the contact angle, on capillary flow will also be discussed.

Allen, Jeffrey S.↗

Overcoming the sensitivity vs. throughput tradeoff in Coulter counters: A novel side counter design

We report microfabricated Coulter counters are attractive for point of care (POC) applications since they are label free and compact. However, these approaches inherently suffer from a trade off between sample throughput and sensitivity. The counter measures a change in impedance due to displaced fluid volume by passing cells, and thus the counter's signal increases with the fraction of the sensing volume displaced. Reducing the size of the sensing region requires reductions in volumetric throughput in the absence of increased hydraulic pressure and sensor bandwidth. The risk of mechanical clog formation, rendering the counter inoperable, increases markedly with reductions in the size of the constriction aperture. We present here a microfluidic coplanar Coulter counter device design that overcomes the problem of constriction clogging while capable of operating in microfluidic channels filled entirely with highly conductive sample. The device utilizes microfabricated planar electrodes projecting into one side of the microfluidic channel and is easily integrated with upstream electronic, hydrodynamic, or other focusing units to produce efficient counting which could allow for dramatically increased volumetric and sample throughput. The design lends itself to simple, cost effective POC applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

BioSentinel ISS Control Experiment Final Investigation Summary Form

Each payload has 18 fluidic cards and each fluidic card has 16 microfluidic wells, for a total of 288 wells. Card activation occurs at different time points throughout the 6-month mission and following ground commands. At each timepoint, two fluidic cards are filled with growth medium containing nutrients and a metabolic indicator dye. In addition to card filling, the temperature of the cards increases from ~4°C (stasis mode) to 23°C to allow for cell growth. The metabolic dye changes color from blue to pink, then pink to clearin the presence of metabolically active yeast cells. The colorimetric changes and cell growth are monitored using a 3-light-emitting diode(LED)optical detection system. The optical data determines how fast the cells are able to recover after accumulating radiation damage over time.After ground command initiation, all the fluidics, thermal and optical detection steps in BioSentinel are fully automated.The biosensor response data is compared to physical dosimetry data collected onboard the same payload. This dosimeter or linear energy transfer (LET)spectrometer is based on TimePix chip technology. This chip measures the total ionizing radiation dose in addition to calculating the LET of each particle that traverses its sensor, thus allowing researchers to characterize the radiation environment around the payload.The biological response (and physical dosimetry) on ISS over time is compared to the deep space mission and to data obtained on the ground.This analysis provides insight on the biological effects of the space radiation exposure in preparation for future long-duration missions to space and inhabitation beyond low-Earth orbit (LEO).

BioSentinel↗

Developing Autonomous Technologies for Biological Missions to Deep Space

In upcoming biological missions beyond low Earth orbit (LEO), the use of autonomous instrumentation will allow scientists to perform a variety of experiments, including the characterization of the response to different space environments (Moon, Mars, interplanetary space) using biological models like microbes, plants, organoids, and tissue chips. BioSentinel is an ongoing deep space mission, currently at over 50 million kilometers from Earth and the first instrument developed to perform biological experiments beyond LEO. Even though the primary objective of this CubeSat mission was to investigate the effects of the deep space radiation environment on budding yeast, the spacecraft bus (i.e., all the subsystems that support the biological payload like power, thermal, data telemetry, navigation, etc.) can accommodate a variety of biological (and physical) experiments and model organisms. LEIA, an upcoming CLPS mission to the lunar surface, uses a microfluidic and optical instrument based on BioSentinel to study the effects of the lunar environment on different cellular processes and on bioproduction of antioxidants. A new series of science mission concepts are being proposed to be accommodated into platforms like BioSentinel. These missions will investigate the response of a variety of organisms to the deep space environment, including but not limited to single-cell eukaryotes, cyanobacteria, plants (including crops), organoids, and tissue chips. In addition to optical absorbance measurements like the ones performed in BioSentinel (and LEIA), we are investigating the use of fluorescence detection, microscopy, sequencing devices, etc. Thus, instruments like the ones proposed here can be adapted to a variety of platforms like free-flyers, deployable payloads, landers, rovers, and the lunar Gateway. These technologies can be used as steppingstones for establishing a sustained human presence on the Moon and in deep space while providing knowledge for the development of potential countermeasures.

Sergio R Santa Maria↗

Biosentinel: Improving Desiccation Tolerance of Yeast Biosensors for Deep-Space Missions

BioSentinel is one of 13 secondary payloads to be deployed on Exploration Mission 1 (EM-1) in 2019. We will use the budding yeast Saccharomyces cerevisiae as a biosensor to determine how deep-space radiation affects living organisms and to potentially quantify radiation levels through radiation damage analysis. Radiation can damage DNA through double strand breaks (DSBs), which can normally be repaired by homologous recombination. Two yeast strains will be air-dried and stored in microfluidic cards within the payload: a wild-type control strain and a radiation sensitive rad51 mutant that is deficient in DSB repairs. Throughout the mission, the microfluidic cards will be rehydrated with growth medium and an indicator dye. Growth rates of each strain will be measured through LED detection of the reduction of the indicator dye, which correlates with DNA repair and the amount of radiation damage accumulated. Results from BioSentinel will be compared to analog experiments on the ISS and on Earth. It is well known that desiccation can damage yeast cells and decrease viability over time. We performed a screen for desiccation-tolerant rad51 strains. We selected 20 re-isolates of rad51 and ran a weekly screen for desiccation-tolerant mutants for five weeks. Our data shows that viability decreases over time, confirming previous research findings. Isolates L2, L5 and L14 indicate desiccation tolerance and are candidates for whole-genome sequencing. More time is needed to determine whether a specific strain is truly desiccation tolerant. Furthermore, we conducted an intracellular trehalose assay to test how intracellular trehalose concentrations affect or protect the mutant strains against desiccation stress. S. cerevisiae cell and reagent concentrations from a previously established intracellular trehalose protocol did not yield significant absorbance measurements, so we tested varying cell and reagent concentrations and determined proper concentrations for successful protocol use.

BioSentinel↗

Biosentinel: Improving Desiccation Tolerance of Yeast Biosensors for Deep-Space Missions

BioSentinel is one of 13 secondary payloads to be deployed on Exploration Mission 1 (EM-1) in 2019. We will use the budding yeast Saccharomyces cerevisiae as a biosensor to determine how deep-space radiation affects living organisms and to potentially quantify radiation levels through radiation damage analysis. Radiation can damage DNA through double strand breaks (DSBs), which can normally be repaired by homologous recombination. Two yeast strains will be air-dried and stored in microfluidic cards within the payload: a wild-type control strain and a radiation sensitive rad51 mutant that is deficient in DSB repairs. Throughout the mission, the microfluidic cards will be rehydrated with growth medium and an indicator dye. Growth rates of each strain will be measured through LED detection of the reduction of the indicator dye, which correlates with DNA repair and the amount of radiation damage accumulated. Results from BioSentinel will be compared to analog experiments on the ISS and on Earth. It is well known that desiccation can damage yeast cells and decrease viability over time. We performed a screen for desiccation-tolerant rad51 strains. We selected 20 re-isolates of rad51 and ran a weekly screen for desiccation-tolerant mutants for five weeks. Our data shows that viability decreases over time, confirming previous research findings. Isolates L2, L5 and L14 indicate desiccation tolerance and are candidates for whole-genome sequencing. More time is needed to determine whether a specific strain is truly desiccation tolerant. Furthermore, we conducted an intracellular trehalose assay to test how intracellular trehalose concentrations affect or protect the mutant strains against desiccation stress. S. cerevisiae cell and reagent concentrations from a previously established intracellular trehalose protocol did not yield significant absorbance measurements, so we tested varying cell and reagent concentrations and determined proper concentrations for successful protocol use.

BioSentinel↗

Advanced Fiber-optic Monitoring System for Space-flight Applications

Researchers at Luna Innovations Inc. and the National Aeronautic and Space Administration s Marshall Space Flight Center (NASA MSFC) have developed an integrated fiber-optic sensor system for real-time monitoring of chemical contaminants and whole-cell bacterial pathogens in water. The system integrates interferometric and evanescent-wave optical fiber-based sensing methodologies with atomic force microscopy (AFM) and long-period grating (LPG) technology to provide versatile measurement capability for both micro- and nano-scale analytes. Sensors can be multiplexed in an array format and embedded in a totally self-contained laboratory card for use with an automated microfluidics platform.

Hull, M. S.↗

Emergent Behavior at the Calcite–Water Interface during Reactive Transport in a Simple Microfluidic Channel

Geochemical reactive transport processes in natural mineral-fluid systems may produce a wide array of emergent phenomena that are difficult to predict from basic principles and to reproduce in model systems. In this study, we present experimental results obtained from a simple microfluidic system with which we explored the consequences of reacting the calcite (104) cleavage surface with an acidic Pb-bearing solution (pH = 3.5, [Pb] total = 5 mM) as a function of flow rate. This system is relevant to passive remediation systems for Pb-rich acid mine drainage. We observed periodic banding in the amounts of Pb sorption at flow velocities ≥ 926 μm s -1 , where the band spacing was spatially correlated with the amount of calcite dissolution and the development of micropyramidal topography on the calcite (104) surface. The equivalent coverage of Pb deposited in these Pb-rich bands was at least several monolayers per unit cell, yet there was no evidence for precipitation of any secondary Pb phase implying incorporation of Pb within the near-surface calcite lattice. We also observed spatial variations in nucleation and growth of euhedral secondary Pb-carbonate minerals hydrocerusite and cerussite at flow rates ≤ 278 μm s -1 ,. These findings demonstrate potential for exploiting the rich phenomenology afforded by the interplay among transport phenomena and chemical kinetics in experimental systems designed to yield deeper insights into geochemical self-organization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rapid Quantification of 237 U Specific Activity for Nuclear Forensics

In the event of an unattributed nuclear explosion, rapid assessment of the short-lived uranium isotope activity and mass can provide valuable information for subsequent forensic analysis. Rapid analysis in the field is enabled by using microfluidic chemistry and deployable instrumentation. Here, this work presents a flow chemistry system, controlled in LabVIEW, that integrates three functionalities: (1) selective extraction of uranium from the sample matrix via a 3D-printed supported liquid membrane module; (2) UV–visible absorbance spectrophotometry to measure the total uranium concentration in the strip flow; and (3) a portable CdTe γ-ray spectrometer coupled to a 3D-printed flow cell to measure 237 U activity concentration in the strip solution. The system was calibrated using standard solutions, and its functionality was demonstrated using a solution of depleted uranium spiked with 237 U. Uranium concentrations of 40–5000 μg/mL were directly quantified online using a 100 mm optical flow cell, while concentrations of 0.5–10 μg/mL were quantified online using a colorimetric reagent. The mass concentration measurement takes approximately 60 min while the activity concentration via γ-ray spectrometry varies depending on the activity of 237 U, with 1 kBq/mL requiring about 30 min of acquisition time to obtain <10% uncertainty at 1σ. This platform provides a fieldable approach for quantifying uranium mass and radioactivity relevant to postdetonation nuclear debris.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

PREPARATION OF CLAY-COATED GLASS SURFACES FOR MICROFLUIDICS-BASED STUDY ON CLAY-FLUID INTERACTIONS

Unique characteristics of clay, even though make any clay abundant shales a good source of adsorbed gas, make them equally difficult to produce. The clay-water interaction can cause significant swelling and fines migration in the shale formation, both of which can significantly impair the overall hydrocarbon recovery from shale. Geomaterial micromodels, developed by functionalizing traditional glass or PDMS surface with geomaterials (e.g., calcite, quartz, clay) can represent the physico-chemical properties of the natural porous media and have been used during the last few years to understand and evaluate the solid-fluid physicochemical interactions. This study focuses on developing a clay-coated geomaterial surface and investigates the effect of base fluid's salinity on clay adsorption to the glass surface. Glass capillary tubes and straight channel borosilicate glass micromodels are coated with Illite clay minerals to represent the pore-scale clay chemistry of Caney Shale, a Mississippian unconventional play in Southern Oklahoma, USA. 10 wt.% of Illite clay slurries made with brines of four different salinities are used to coat the glass-capillary tubes to understand the effect of salinity in clay adsorption on the glass surface and overall coating quality. To achieve a stable coating and evaluate the impact of heat treatment on coating's stability, straight channel glass flow cells coated with Illite clay are heat-treated at low (25 °C) and high temperature (125 °C). Dynamic flooding tests were carried out with brines on the coated surface to evaluate the stability of the coating. The experiments' outcome indicated a strong relationship between the brine's salinity and the adsorption of clay particles on the glass surface. An increase in brine concentration resulted in improved adsorption of clay particles on the glass surface. Experiments involving heat treating the glass surface following the coating demonstrated significant improvement in the stability of the coating.

02 PETROLEUM↗

Preparation of illite coated geomaterial microfluidic surfaces: Effect of salinity and heat treatment

Unique characteristics of clay (e.g., high surface area, deficiency in positive charges) make any clay abundant shales a good source of adsorbed gas. However, the presence of clay in porous media can also affect shale rock's producibility. The clay-water interaction can cause significant swelling and fines migration in the formation and impair the overall hydrocarbon recovery from shale. Geomaterial micromodels, developed by functionalizing traditional glass or PDMS surfaces with geomaterials (e.g., calcite, Quartz, clay), can represent the physicochemical properties of the natural porous media and have been used during the last few years to understand and evaluate the solid-fluid physicochemical interactions. Here, this study focuses on developing a clay-coated geomaterial surface and investigates the effect of base fluid's salinity on clay adsorption to the glass surface. Glass capillary tubes and straight channel borosilicate glass micromodels are coated with Illite clay to represent the pore-scale clay chemistry of Caney Shale, a Mississippian unconventional play in Southern Oklahoma, USA. 10 wt% of Illite clay slurries made with brines of four different salinities are used to coat the glass-capillary tubes to understand the effect of salinity in clay adsorption on the glass surface and overall coating quality. To achieve a stable coating and evaluate the impact of heat treatment on coating's stability, straight channel glass flow cells coated with Illite clay are heat-treated at low (25 °C) and high temperature (125 °C), and the results are compared with an untreated coated surface. Flooding tests were carried out with brines of different salinities on the coated surface to evaluate the stability of the coating. The experimental results indicated a strong relationship between the brine's salinity and the adsorption of clay particles on the glass surface. An increase in brine concentration resulted in improved adsorption of clay particles on the glass surface. Experiments involving heat treating the glass surface following the coating demonstrated significant improvement in the stability of the coating.

02 PETROLEUM↗