Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “microchannel plate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

A low-energy gamma-ray imaging detector

We describe a hard-X-ray/soft-gamma-ray imaging detector, incorporating a microchannel-plate (MCP) electron multiplier for possible use in future telescopes. In contrast to previous attempts using MCP's this approach promises to achieve high quantum detection efficiencies in addition to high spatial and temporal resolution. Preliminary results indicate not only the capability of simultaneous imaging and single-photon counting, but also coarse energy resolution.

Yin, L. I.↗

A rocket-borne faint object spectrograph with a codacon detector

A rocket payload, consisting of a Rowland circle spectrograph with a multi-anode, microchannel plate detector, located at the focus of a 40 cm mirror, has been constructed to observe faint astronomical objects in the 900 to 1800 A spectral region. It can obtain the spectrum of an unreddened, V = 10m OB star with 3 A resolution and + or 3% precision in a 60 second observation.

Lillie, C. F.↗

Low-distortion resistive anodes for two-dimensional position-sensitive MCP systems

Microchannel plates (MCPs) are frequently used with resistive anodes to detect charged particles or photons and yield analog signals from which event positions can be decoded. The paper discusses a four-corner concave circular arc terminated resistive anode that permits theoretically distortionless encoding of Cartesian event positions into pulse charge ratios. The theory of the circular arc terminated anode is discussed along with anode design and performance. Electron beam images obtained by using such an anode are presented to confirm the usefulness of the approach.

Lampton, M.↗

Crossed-grid charge locator

Circuit locates center of cloud of charge on wire grid to within 6.5 micrometers. Wires in vicinity of charge cloud develop voltages that are processed by priority encoders to develop coarse and fine position codes. Device is used with microchannel plate amplifier in X-ray photon detectors, electron microscopes, and closed-circuit television.

Harrison, D. C.↗

Dosimetric considerations in dental applications

The integration of the Lixiscope into dental procedures was studied and compared with conventional dental radiographic techniques. It was found that through the use of intraoral sealed sources in conjunction with microchannel plate technology, the Lixiscope gives increased diagnostic information with decreased radiation dosage.

Goble, J. C.↗

A real-time electronic imaging system for solar X-ray observations from sounding rockets

A real-time imaging system for displaying the solar coronal soft X-ray emission, focussed by a grazing incidence telescope, is described. The design parameters of the system, which is to be used primarily as part of a real-time control system for a sounding rocket experiment, are identified. Their achievement with a system consisting of a microchannel plate, for the conversion of X-rays into visible light, and a slow-scan vidicon, for recording and transmission of the integrated images, is described in detail. The system has a quantum efficiency better than 8 deg above 8 A, a dynamic range of 1000 coupled with a sensitivity to single photoelectrons, and provides a spatial resolution of 15 arc seconds over a field of view of 40 x 40 square arc minutes. The incident radiation is filtered to eliminate wavelengths longer than 100 A. Each image contains 3.93 x 10 to the 5th bits of information and is transmitted to the ground where it is processed by a mini-computer and displayed in real-time on a standard TV monitor.

Davis, J. M.↗

Rocket instrument for far-UV spectrophotometry of faint astronomical objects

A sensitive sounding rocket instrument for moderate (about 10-A) resolution far-UV (1160-1750-A) spectrophotometry of faint astronomical objects has been developed. The instrument employes a photon-counting microchannel plate imaging detector and a concave grating spectrograph behind a 40-cm Dall-Kirkham telescope. A unique remote-control pointing system, incorporating an SIT vidicon aspect camera, two star trackers, and a tone-encoded command telemetry link, permits the telescope to be oriented to within 5 arc sec of any target for which suitable guide stars can be found. The design, construction, calibration, and flight performance of the instrument are discussed.

Hartig, G. F.↗

Atmospheric Emission Photometric Imaging on Spacelab (AEPI)

Two parallel detector systems are used for atmospheric emission photometric emission. The top system is a TV system using the image intensified S.E.C. tube as the detector. The bottom system, the photon counting array (P.C.A.), uses a microchannel plate intensified anode array tube and is equivalent to a 100 channel photomultiplier. For the television, the filters are selected by means of a filter wheel set. The field of view of the is interchangeable between 20 and 6 degrees, by means of a moveable prism. The quartz window mu channel plate intensifier is fiber optically coupled to a 40-25 demagnifying tube which is in turn coupled to the S.E.C. tube. The PCA channel has a fixed field of view of 4 deg and a remote control interchangeable photometric converter optics which converts the imaging array into a multichannel photometer. The mu channel plate array tube amplifies the photons into detectable counts for the PCA electronics. The entire system is pointed by a two axis gimbal. The flight equipment to be acquired consists of a gyro package and an interactive flight control unit panel. The gyro package is necessary because of the inadequate attitude reference supplied by the current Spacelab systems.

Mende, S. B.↗

Measurements of mass flow in the transition region and inner corona

A solar rocket experiment launched on June 5, 1979 is described which provides high spectral resolution line profiles across the solar disk. The instrument consists of a small telescope with moderate spatial resolution and a spectrograph with stability and high spectroscopic resolution (about 0.028 A at 600 A). The detector system uses a microchannel plate array to provide 1,024 simultaneous measurements spanning approximately 30 A of the solar spectrum. The spectrograph uses a 3600 l/mm grating, and the spectral range 609-634 A is recorded in second order overlapping 1218-1268 A in first order. The position of the emission lines is determined by a center-of-mass routine and velocity shifts are evident. The qualitative results are in general agreement with the results of Cushman and Rense (1976).

Rottman, G. J.↗

Nuclear Science Symposium, 27th, and Symposium on Nuclear Power Systems, 12th, Orlando, Fla., November 5-7, 1980, Proceedings

Advances in instrumentation for use in nuclear-science studies are described. Consideration is given to medical instrumentation, computerized fluoroscopy, environmental instrumentation, data acquisition techniques, semiconductor detectors, microchannel plates and photomultiplier tubes, reactor instrumentation, neutron detectors and proportional counters, and space instrumentation.

Martini, M.↗

Atmospheric emissions photometric imaging experiment /AEPT/ for Spacelab 1

The atmospheric emissions photometric imaging experiment (AEPI) to be flown on Spacelab 1 is designed to study faint natural and artificial atmospheric emission phenomena. Optical emissions are imaged in the region 2150 A to 7320 A using a television system consisting of two optical channels, one wide-angle and one telephoto. The detection system is an image-enhanced SEC vidicon. A third optical channel images onto the photocathode of a microchannel plate photomultiplier tube that has 100 discrete anodes. Photons are counted for each discrete anode, providing a direct measure of the luminosity of an object viewed by the TV telephoto lens, albeit with low spatial resolution. The AEPI detector is mounted on a two-axis gimbal comprised of a Modified Apollo Telescope Mount Star Tracker (MAST), which provides experiment pointing over a 40-deg x 80-deg range, exclusive of restrictions due to the proximity of other experiments. The pointing stability is 1 arcmin with respect to the spacecraft coordinate system for an exposure of 1 second. The tracking capability is 3.5 deg/s with a stability of 1 arcmin. The detector and pointing system are located on the Spacelab pallet. The experiment is controlled by stored programs resident in the Dedicated Experiment Processor located in the Spacelab module.

Sandie, W. G.↗

The Johns Hopkins Ultraviolet Telescope for Shuttle astronomy

The Hopkins Ultraviolet Telescope (HUT) is a 90-cm f/2 prime focus telescope and spectrometer with a photon-counting microchannel plate detector designed to obtain moderate resolution (wavelength interval, approximately 4 A) spectrophotometry of faint (visual magnitude, less than approximately 17) objects in the far-ultraviolet spectral region (approximately 900-1700 A). The HUT will be mounted on the Spacelab Instrument Pointing System and will be operated by a Payload Specialist using a field acquisition TV system to assist in locating targets. The initial flight of the HUT, expected in 1984 or 1985, will be devoted primarily to the study of quasars and active galactic nuclei, emphasizing the 900-1200 A spectral region which is inaccessible with other existing or currently planned orbiting instruments.

Davidson, A. F.↗

Imaging X-ray spectrophotometers

A new instrument which combines the good energy resolution of the gas scintillation proportional counter with the high position resolution of the microchannel plate is proposed. A study of the factors which determine the combined energy and position resolution of the new instrument is discussed. Submillimeter position resolution along with good energy resolution (8% fwhm at 6 keV) should be achievable.

Hailey, C. J.↗

Wedge-and-strip anodes for centroid-finding position-sensitive photon and particle detectors

The paper examines geometries employing position-dependent charge partitioning to obtain a two-dimensional position signal from each detected photon or particle. Requiring three or four anode electrodes and signal paths, images have little distortion and resolution is not limited by thermal noise. An analysis of the geometrical image nonlinearity between event centroid location and the charge partition ratios is presented. In addition, fabrication and testing of two wedge-and-strip anode systems are discussed. Images obtained with EUV radiation and microchannel plates verify the predicted performance, with further resolution improvements achieved by adopting low noise signal circuitry. Also discussed are the designs of practical X-ray, EUV, and charged particle image systems.

Martin, C.↗

Real-time observation of X-ray diffraction patterns with the Lixiscope

The feasibility of the Lixiscope (Low Intensity X-ray Imaging Scope) is demonstrated for real-time observation of transmission Laue patterns. Making use of the high-gain capability of microchannel plate (MCP) visible-light image intensifier tubes, X-ray images are converted to visible-light images by a scintillator. Pb discs are taped to the center of the Lixiscope input face, and crystal samples are held on a goniometer stage with modeling clay. With a compact size to facilitate off axis viewing, and real-time viewing to allow instantaneous response, the Lixiscope may prove useful in dynamic studies of the effects of plastic flows, stresses, high pressures, and low temperatures.

Chung, D. Y.↗

A systematic program of cometary spectroscopy

Some early results of a systematic program of observing the spectroscopic behavior of comets as a function of heliocentric distance are presented. An ultraviolet sensitive microchannel plate intensifier spectrograph was used to record the 3000-5000A spectrum of comets brighter than magnitude 17 with a spectral resolution of 8 or 16A, followed by direct image for better interpretation of the spatial distribution of spectral features. Although the goals of the program require much more time and data, some interesting results from Comets Schwassmann-Wachmann, 1, Bradfield and Bowell were obtained.

Larson, S. M.↗

Spectroscopic observations of comets

Development of a spectrograph using a microchannel plate intensifier for observing faint comets is described. The spectrograph is capable of obtaining useful spectra of objects as faint as M(2) = 18. The increased guiding efficiency achieved by the optical coupling of the ISIT vidicon of the 154 cm telescope has resulted in a better signal to noise ratio. The ability to take a direct image of the comet aids in the interpretation of the spatial profile of the emissions. Spectra of comets Schwassmann-Wachmann 1, Bradfield, Encke, Tuttle, and Stephen-Oterma are discussed.

Source record↗

A wide-field soft X-ray camera

A wide-field soft X-ray camera (WFSXC) sensitive in the 50 to 250 eV band is described. The camera features Wolter-Schwarzschild optics with an 8 degree field of view and 300 cu cu collecting area. The focal plane instrument is a microchannel plate detector. Broad-band energy discrimination is provided by thin-film filters mounted immediately in front of the focal plane. The WFSXC is capable of detecting sources with intensities greater than 5 percent of HZ 43 during typical sounding rocket exposures, and it would approach the same sensitivity range as EUVE during a typical exposure from the Shuttle.

Petre, R.↗