Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “measurement protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Comparison Between Continuous and Intermittent Actigraphy Outcomes During Long-Duration Missions

INTRODUCTION Historically, astronauts have worn actigraphy watches continuously throughout their missions. This has enabled reliable sleep estimation and comparisons between sleep and other outcomes and mission activities such as the arrival of a visiting vehicle. However in late 2020, astronauts were scheduled to wear an actiwatch for one 2-week period every two months, substantially decreasing availability of data. Our aim was to compare sleep and mission events between data collected continuously and data collected intermittently to identify any differences. METHODS Crewmembers (n = 19) who volunteered for the NASA Standard Measures protocol between January 2019 and March 2022 were provided with actiwatches (Phillips, Respironics, Bend OR) that they wore either continuously (C; n = 9) or for two weeks every two months while in space (2W; n = 10). We used crew schedules to identify mission events that were asynchronous with actigraphy. We further compared sleep outcomes (sleep duration, wake after sleep onset [WASO], sleep efficiency) between the C and 2W actigraphy collection. RESULTS In the 2W group, sleep data was not available for 52% of EVAs, 67% of visiting vehicle events, and 67% of commander turnovers. Average sleep duration for the 2W group (M = 6.91, ± 1.24 SD) was significantly lower compared to the C group (7.51 ± 1.08, p < .01). Sleep efficiency was better for those in the C group (90.56 ± 5.19) than for those in the 2W group (87.02 ± 6.47 p < .01). There were no significant differences in WASO (C = 26.66 ±12.99; 2W = 32.38 ± 18.83). DISCUSSION Continuous actigraphy data collection yields different sleep outcomes compared to intermittent data collection. In addition, many mission events were not captured with intermittent data collection. Our findings support the use of continuous actigraphy data collection.

fatigue↗

Astronaut Sleep Duration Varies by Timing of Scheduled Sleep

INTRODUCTION: Studies find that humans average approximately six hours of sleep per night in space, which is less than they sleep on Earth. Such short sleep duration has been associated with reduced alertness and performance in space. It is unclear whether this sleep loss is related to modifiable factors, such as irregular scheduling, poor sleep environment, and excessive workload or due to features of spaceflight that alter physiology (e.g., microgravity). Recent missions have afforded crew better, more stable sleep and work schedules, and an improved sleep environment. Despite these improvements, schedules do still vary enough to cause decrements in sleep duration. METHODS: Crewmembers (n = 19) who volunteered for the NASA Standard Measures protocol between January 2019 and March 2022 were provided with actiwatches (Phillips, Respironics, Bend OR) that they wore for two bouts of data collection lasting two weeks each before flight (at approximately L-270 and L-180), either continuously (n = 9) or for two weeks every two months while in space (n = 10), and for seven days postflight, immediately upon return to Earth (R+0). A regularly scheduled (or “nominal”) sleep episode would take place between the hours of 9:30pm and 6:00am. We looked at sleep outcomes (sleep duration, wake after sleep onset [WASO], sleep efficiency) depending on the distance from nominal sleep offset to see whether scheduled sleep period affected sleep durations and other metrics of sleep quality. RESULTS: Crewmembers provided data from 402 nights preflight, 2,137 nights inflight, and 275 nights postflight. They averaged 7.33 hours of sleep per night (± 1.16, SD) in space. Though this was significantly less sleep than they achieved preflight (7.87 ± 1.10) or postflight (7.75 ± 1.43, p < .01), this duration of sleep meets the recommended amount for optimal human health and well-being. For every hour after the nominal sleep period a crewmember woke up, their total sleep increased by 25 minutes (up to 5 hours). CONCLUSIONS: We conclude that humans are capable of achieving sufficient sleep in space, especially when their schedules afford adequate sleep (namely, schedules that phase delay rather than advance). Future studies are needed to determine whether microgravity impacts sleep architecture and sleep quality. Going forward, it is imperative that crewmembers are provided with stable schedules, with moderate workload, and environments that are conducive to sleep.

fatigue↗

Field Emission Analysis in SRF Cavities for PIP-II Using GEANT4

Field emission (FE) remains a significant hurdle for achieving optimal performance and reliability in super-conducting radiofrequency (SRF) cavities used in accelerator cryomodules. A thorough understanding of the generation and propagation of FE-induced radiation is therefore essential to mitigate this problem. The absence of standardized measurement protocols further complicates the comparison of radiation data across different testing phases and facilities. This highlights the need for a precise quantitative method to diagnose and analyze FE-induced radiation. Such efforts could prove beneficial for improving cavity preparation and cleanroom assembly techniques during the prototype and production stages of Fermilab's Proton Improvement Plan-II (PIP-II) project. This study presents the initial steps of detailed Geant4 simulations aimed at analyzing FE-induced radiation in the low-beta 650 MHz 5-cell elliptical (LB650) cavity. Our goal is to combine these results with radiation diagnostics to enhance diagnostic accuracy and optimize detector positioning. This integrated approach ultimately aims to improve the preparation, assembly, and testing procedures for PIP-II SRF cavities, ensuring the delivery of FE-free cryomodules.

Wijethunga, S. A.K. [Fermilab] (ORCID:000000028765↗

Ocean Optics Protocols for Satellite Ocean Color Sensor Validation: Inherent Optical Properties: Instruments, Characterizations, Field Measurements and Data Analysis Protocols - Volume 4

This document stipulates protocols for measuring bio-optical and radiometric data for the Sensor Intercomparison and Merger for Biological and Interdisciplinary Oceanic Studies (SIMBIOS) Project activities and algorithm development. The document is organized into 6 separate volumes as Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Revision 4. Volume I: Introduction, Background and Conventions; Volume II: Instrument Specifications, Characterization and Calibration; Volume III: Radiometric Measurements and Data Analysis Methods; Volume IV: Inherent Optical Properties: Instruments, Characterization, Field Measurements and Data Analysis Protocols; Volume V: Biogeochemical and Bio-Optical Measurements and Data Analysis Methods; Volume VI: Special Topics in Ocean Optics Protocols and Appendices. The earlier version of Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Revision 3 (Mueller and Fargion 2002, Volumes 1 and 2) is entirely superseded by the six volumes of Revision 4 listed above.

Mueller, J. L.↗

Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Revision 4, Volume IV: Inherent Optical Properties: Instruments, Characterizations, Field Measurements and Data Analysis Protocols

This document stipulates protocols for measuring bio-optical and radiometric data for the Sensor Intercomparision and Merger for Biological and Interdisciplinary Oceanic Studies (SIMBIOS) Project activities and algorithm development. The document is organized into 6 separate volumes as Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Revision 4. Volume I: Introduction, Background, and Conventions; Volume II: Instrument Specifications, Characterization and Calibration; Volume III: Radiometric Measurements and Data Analysis Methods; Volume IV: Inherent Optical Properties: Instruments, Characterization, Field Measurements and Data Analysis Protocols; Volume V: Biogeochemical and Bio-Optical Measurements and Data Analysis Methods; Volume VI: Special Topics in Ocean Optics Protocols and Appendices. The earlier version of Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Revision 3 is entirely superseded by the six volumes of Revision 4 listed above.

Mueller, J. L.↗

Demonstration and Concept of Operations for a Zero-Knowledge Protocol Passive Imaging Measurement for Arms Control

Here, we present an imaging system that employs zero-knowledge protocols to protect sensitive geometrical information, along with procedures to increase confidence in the result. The goal of this work is to enable the inclusion of warhead confirmation measurements in future arms control treaties. We present a demonstration of both true positive and true negative measurements that validate models and establish authenticating procedures toward meeting acceptance requirements for use in nuclear facilities. We use a two-dimensional time-encoded fast neutron imaging system with an anti-symmetric mask pattern; the fast neutron count values exceeding minimum or maximum thresholds indicate that two measured items are not identical. Laboratory measurements over twenty trials show that alarm rates for negative confirmation measurements are within uncertainties of model predictions. Positive confirmation measurements indicate that alarm rates are large enough to encourage treaty compliance.

Sweany, Melinda Dominique [Sandia National Laborat↗

Protocol for Uniformly Measuring and Expressing the Performance of Energy Storage Systems

The U.S. Department of Energy’s Energy Storage Systems (ESS) Program, through the support of Pacific Northwest National Laboratory (PNNL) and Sandia National Laboratories (SNL), facilitated the development of the protocol provided in this report. The focus of the protocol is to provide a uniform way of measuring, quantifying, and reporting the performance of EESs in various applications; something that does not exist today and, as such, is hampering the consideration and use of this technology in the market. The availability of an application-specific protocol for use in measuring and expressing performance-related metrics of ESSs will allow technology developers, power-grid operators and other end-users to evaluate the performance of energy storage technologies on a uniform and comparable basis. This will help differentiate technologies and products for specific application(s) and provide transparency in how performance is measured. It also will assist utilities and other consumers of ESSs make more informed decisions as they consider the potential application and use of ESSs, as well as form the basis for documentation that might be required to justify utility investment in such technologies.

Bray, Kathryn L.↗

Protocol for uniformly measuring and expressing the performance of energy storage systems.

The U.S. Department of Energy s Energy Storage Systems (ESS) Program, through the support of Pacific Northwest National Laboratory (PNNL) and Sandia National Laboratories (SNL), facilitated the development of the protocol provided in this report. The focus of the protocol is to provide a uniform way of measuring, quantifying, and reporting the performance of ESSs in various applications; something that does not exist today and, as such, is hampering the consideration and use of this technology in the market. The availability of an application-specific protocol for use in measuring and expressing performance-related metrics of ESSs will allow technology developers, power-grid operators and other end-users to evaluate the performance of energy storage technologies on a uniform and comparable basis. This will help differentiate technologies and products for specific application(s) and provide transparency in how performance is measured. It also will assist utilities and other consumers of ESSs to make more informed decisions as they consider the potential application and use of ESSs, as well as form the basis for documentation that might be required to justify utility investment in such technologies.

Ferreira, Summer Kamal Rhodes↗

Whole Building Cost and Performance Measurement: Data Collection Protocol Revision 2

This protocol was written for the Department of Energy’s Federal Energy Management Program (FEMP) to be used by the public as a tool for assessing building cost and performance measurement. The primary audiences are sustainable design professionals, asset owners, building managers, and research professionals within the Federal sector. The protocol was developed based on the need for measured performance and cost data on sustainable design projects. Historically there has not been a significant driver in the public or private sector to quantify whole building performance in comparable terms. The deployment of sustainable design into the building sector has initiated many questions on the performance and operational cost of these buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Two Experimental Protocols for Accurate Measurement of Gas Component Uptake and Production Rates in Bioconversion Processes

Abstract Bioconversion processes offer many economic, environmental, and societal advantages for production of fuels and chemicals. Successful commercialization of any biotechnology usually requires accurate characterization of cell growth dynamics, substrate conversion and production excretion rates. Despite recent advancements in analytical equipment, obtaining accurate measurement of gas component uptake or production rates remains challenging due to their high sensitivity to system pressure or volume changes. Specifically, the consumption and production of various gases will result in changes in system pressure (for batch operations) or off-gas flow rate (for continuous operations). These changes would cause significant errors in the estimated gas component uptake and production rates if they were not accounted for. In this work, we propose two easy-to-implement experimental protocols and associated calculation procedures to obtain accurate measurements of gas component consumption and production rates; one is for batch operation and one is for continuous operation. For depressurized ( i . e ., system pressure below 1 atm) batch cultures, nitrogen (or other inert gases) is used to repressurize the system to 1 atm before taking sample; while for continuous cultures, He (or other inert gases) is used as an internal tracer to accurately measure off-gas flow rate. The effectiveness and accuracy of the two protocols and associated calculation procedures are demonstrated using several case studies with both abiotic and biotic systems.

59 BASIC BIOLOGICAL SCIENCES↗

Evaluation of similarity measures for use in the intensity-based rigid 2D-3D registration for patient positioning in radiotherapy

Purpose: Rigid 2D-3D registration is an alternative to 3D-3D registration for cases where largely bony anatomy can be used for patient positioning in external beam radiation therapy. In this article, the authors evaluated seven similarity measures for use in the intensity-based rigid 2D-3D registration using a variation in Skerl's similarity measure evaluation protocol. Methods: The seven similarity measures are partitioned intensity uniformity, normalized mutual information (NMI), normalized cross correlation (NCC), entropy of the difference image, pattern intensity (PI), gradient correlation (GC), and gradient difference (GD). In contrast to traditional evaluation methods that rely on visual inspection or registration outcomes, the similarity measure evaluation protocol probes the transform parameter space and computes a number of similarity measure properties, which is objective and optimization method independent. The variation in protocol offers an improved property in the quantification of the capture range. The authors used this protocol to investigate the effects of the downsampling ratio, the region of interest, and the method of the digitally reconstructed radiograph (DRR) calculation [i.e., the incremental ray-tracing method implemented on a central processing unit (CPU) or the 3D texture rendering method implemented on a graphics processing unit (GPU)] on the performance of the similarity measures. The studies were carried out using both the kilovoltage (kV) and the megavoltage (MV) images of an anthropomorphic cranial phantom and the MV images of a head-and-neck cancer patient. Results: Both the phantom and the patient studies showed the 2D-3D registration using the GPU-based DRR calculation yielded better robustness, while providing similar accuracy compared to the CPU-based calculation. The phantom study using kV imaging suggested that NCC has the best accuracy and robustness, but its slow function value change near the global maximum requires a stricter termination condition for an optimization method. The phantom study using MV imaging indicated that PI, GD, and GC have the best accuracy, while NCC and NMI have the best robustness. The clinical study using MV imaging showed that NCC and NMI have the best robustness. Conclusions: The authors evaluated the performance of seven similarity measures for use in 2D-3D image registration using the variation in Skerl's similarity measure evaluation protocol. The generalized methodology can be used to select the best similarity measures, determine the optimal or near optimal choice of parameter, and choose the appropriate registration strategy for the end user in his specific registration applications in medical imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ground-Based Measurements and Validation Protocols for Flex

The upcoming ESA Fluorescence Explorer (FLEX) mission will incorporate ground-based validations for fluorescence parameters and reflectance indices, drawing on an international network of sensors located at eddy covariance tower sites. A program has been initiated by the OPTIMISE program to develop methods and protocols for this network. A sensor system suite under evaluation by OPTIMISE includes the FLoX hyperspectral spectroradiometers. The NASA team at GSFC is participating in this experiment and we report first results from the 2017 summer measurements made above the canopy at the USDA/ARS Beltsville cornfield using the DFLoX and two other leaf-level measurement systems, the MONI-PAM and the FluoWat.

DFLOX↗

Integration of a hyphenated HPIC-ICPMS protocol for the measurement of transplutonium isotopic mass distributions for 252Cf campaigns at Oak Ridge National Laboratory

Rapid measurement of transplutonium isotopic mass distributions during 252Cf production campaigns at Oak Ridge National Laboratory is a critical need. Mass measurements for the isotopes of plutonium, americium, curium, and californium are routinely requested to support the α-hydroxy-isobutyrate runs for the purification and recovery of the heavy curium target material and final 249Bk, 252Cf, and 254Es enriched isotope products. This paper presents the integration of an online high-pressure ion chromatography inductively coupled plasma mass spectrometry technique together with the protocol and chemistry that allows for rapid baseline separation and direct quantification of the transplutonium elemental concentrations and isotopic compositions.

Roach, Benjamin↗

A protocol for the measurement of all the parameters of the mass transfer kinetics in columns used in liquid chromatography

Band broadening in chromatography results from the combination of the dispersive effects that are associated with the different steps involved in the migration of compound bands along the column. These steps include longitudinal diffusion, trans-particle mass transfer, external film mass transfer, overall eddy diffusion, including trans-column, short-range inter-channel, trans-channel eddy diffusion, and the possible, additional mass transfer contributions arising from heat friction and the thermal heterogeneity of the column. We describe a series of experiments that provide the data needed to determine the coefficients of the contributions to band broadening of each one of these individual mass transfer steps. This specifically designed protocol can provide key information regarding the kinetic performance of columns used in liquid chromatography and explain why different columns behave so differently. The limitations, accuracy and precision of these methods are discussed. Further avenues of research that could improve the characterization of the mass transfer mechanisms in chromatographic columns, possibly contributing to the development of better columns, are suggested.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Poster — Thur Eve — 20: CTDI Measurements using a Radiochromic Film-based clinical protocol

The purpose of the study was evaluating accuracy and reproducibility of a radiochromic film-based protocol to measure computer tomography dose index (CTDI) as a part of annual QA on CT scanners and kV-CBCT systems attached to linear accelerators. Energy dependence of Gafchromic XR-QA2 ® film model was tested over imaging beam qualities (50 – 140 kVp). Film pieces were irradiated in air to known values of air-kerma (up to 10 cGy). Calibration curves for each beam quality were created (Film reflectance change Vs. Air-kerma in air). Film responses for same air-kerma values were compared. Film strips were placed into holes of a CTDI phantom and irradiated for several clinical scanning protocols. Film reflectance change was converted into dose to water and used to calculate CTDIvol values. Measured and tabulated CTDIvol values were compared. Average variations of ±5.2% in the mean film reflectance change were observed in the energy range of 80 to 140 keV, and 11.1% between 50 and 140 keV. Measured CTDI values were in average 10% lower than tabulated CTDI values for CT-simulators, and 44% higher for CBCT systems. Results presented a mean variation for the same machine and protocol of 2.6%. Variation of film response is within ±5% resulting in ±15% systematic error in dose estimation if a single calibration curve is used. Relatively large discrepancy between measured and tabulated CTDI values strongly support the trend towards replacing CTDI value with equilibrium dose measurement in the center of cylindrical phantom, as suggested by TG- 111.

07 ISOTOPE AND RADIATION SOURCES↗

A Robust Protocol for Entropy Measurement in Mesoscopic Circuits

Previous measurements utilizing Maxwell relations to measure change in entropy, S, demonstrated remarkable accuracy in measuring the spin-1/2 entropy of electrons in a weakly coupled quantum dot. However, these previous measurements relied upon prior knowledge of the charge transition lineshape. This had the benefit of making the quantitative determination of entropy independent of scale factors in the measurement itself but at the cost of limiting the applicability of the approach to simple systems. To measure the entropy of more exotic mesoscopic systems, a more flexible analysis technique may be employed; however, doing so requires a precise calibration of the measurement. Here, we give details on the necessary improvements made to the original experimental approach and highlight some of the common challenges (along with strategies to overcome them) that other groups may face when attempting this type of measurement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗