Engineering PapersSearch

SEARCH · Engineering Papers

Results for “mean average precision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

334 records · Page 9

The HEROIX Broadband X-Ray Space Telescope Mission Concept

The High EneRgy Observatory for Imaging X-rays (HEROIX) Medium-Class Mission concept envisions a next-generation broadband X-ray observatory designed to meet the astrophysics community’s need for high-angular-resolution studies of the Cosmic X-ray Background. Building on the science legacy of NASA’s NuSTAR mission and more than 30 years of advances in replicated NiCo shell technology at NASA Marshall, HEROIX proposes a space observatory comprising four co-aligned telescopes achieving 5 arcsecond half-power diameter (HPD) angular resolution. This capability, approached by the resolution demonstrated in the FOXSI-4 sounding rocket mission and under development through the SuperHERO balloon mission, will be extended to energies up to 80 keV through multilayer coatings. Marshall’s inhouse precision optics manufacturing enables an integrated effective area of 380 cm² at 30 keV, which, combined with high-resolution optics, opens new windows into extreme astrophysical non-thermal processes.

Nick Thomas

Stoichiometry dependent properties of cerium hydride: An active learning developed interatomic potential study

Cerium hydride has a variety of interesting properties, including a known lattice contraction and densification with increasing hydrogen content. However, precise stoichiometric control is not experimentally straightforward and ab initio approaches are not computationally feasible for many properties such as melting and low temperature diffusion. Therefore, we develop a machine-learned interatomic potential for cerium hydride that is valid for H to Ce ratios from 2.0 to 3.0. A query-by-committee active learning approach is used to develop the training set. Leveraging classical molecular dynamics simulations, we assess a range of properties and provide fundamental mechanisms for the trends with stoichiometry. Finally, a majority of the properties follow the trend of lattice contraction, being governed by the stronger lattice binding induced by adding octahedral atoms.

36 MATERIALS SCIENCE

Biochemical approaches for synthesis of performance-advantaged polymers from lignocellulosic biomass

Lignocellulose is an abundant renewable feedstock for production of sustainable fuels, chemicals, and materials. The structural complexity of lignocellulose provides key material properties and inspires the design of advanced materials. However, this same complexity also presents challenges for conversion of lignocellulosic biomass into new materials with consistent properties. Conventional physical and chemical strategies for valorization of biomass to new materials are often limited by the technical challenges of precisely manipulating complex feedstocks, sensitivity to feedstock variability, and associated costs. In contrast, biological approaches are capable of selectively manipulating complex architectures under mild conditions. Recent advances demonstrate the potential of biological and hybrid biochemical methods to tailor biomass-derived polymers and generate new materials. This review provides an overview of biological strategies to valorize lignocellulosic biomass into novel materials, highlighting approaches for in planta engineering, biochemical modification of natural biomass polymers, microbial funneling of deconstructed biomass, and direct biosynthesis of novel polymers. In combination, these approaches open new avenues for the synthesis of performance-advantaged materials from lignocellulosic biomass.

Qian, Liangyu [ORNL] (ORCID:0009000212029938)

New Lithium-ion Polymer Battery for the Extravehicular Mobility Unit Suit

The Extravehicular Mobility Unit (EMU) suit currently has a silver-zinc battery that is 20.5 V and 45 Ah capacity. The EMU's portable life support system (PLSS) will draw power from the battery during the entire period of an EVA. Due to the disadvantages of using the silver-zinc battery in terms of cost and performance, a new high energy density battery is being developed for future use, The new battery (Lithium-ion battery or LIB) will consist of Li-ion polymer cells that will provide power to the EMU suit. The battery design consists of five 8 Ah cells in parallel to form a single module of 40 Ah and five such modules will be placed in series to give a 20.5 V, 40 Ah battery. Charging will be accomplished on the Shuttle or Station using the new LIB charger or the existing ALPS (Air Lock Power Supply) charger. The LIB delivers a maximum of 3.8 A on the average, for seven continuous hours, at voltages ranging from 20.5 V to 16.0 V and it should be capable of supporting transient pulses during start up and once every hour to support PLSS fan and pump operation. Figure 1 shows the placement of the battery in the backpack area of the EMU suit. The battery and cells will undergo testing under different conditions to understand its performance and safety characteristics.

Jeevarajan, J. A.

Crack‐Free Single‐Crystalline LiNiO 2 for High Energy Density All‐Solid‐State Batteries

Abstract Single‐crystalline layered oxide (LiNi 1‐ x ‐ y Mn x Co y O 2 ) cathodes have been found to exhibit exceptional electrochemical properties when coupled with various inorganic solid electrolytes (ISEs) in all‐solid‐state batteries (ASSBs). Their advantages stem from the robust morphological integrity with the absence of grain boundaries and the high electrochemical oxidative stability. Here, ASSBs featuring single‐crystalline LiNiO 2 (LNO) with the highest Ni content are reported, offering a high theoretical specific capacity of 275 mAh g ‐1 alongside a high average discharge voltage (3.7 V vs Li + /Li). Through a careful investigation, it is demonstrated that micron‐sized single‐crystalline LNO (µSC‐LNO) composite cathodes with a halide ISE exhibit a high initial discharge capacity of 205 mAh g ‐1 with an outstanding cycle performance over 200 cycles in room‐temperature ASSBs. The significance of engineering parameters is emphasized, such as particle size and specific density, in promoting a homogeneous and fast Li + transport within the composite cathodes. Furthermore, the formation of undesirable interphase between the halide ISE in the cathode and sulfide ISE separator is elucidated, which may be a critical factor impeding long‐term cyclability of ASSBs. This work provides insights into the design of composite cathodes for high‐energy‐density ASSBs.

Chemistry

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Calculating a minimum overlap period for successful intercalibration of soil moisture sensors

Abstract Long‐term in situ soil moisture monitoring inevitably requires sensors to be replaced. Ensuing discontinuities in the data record can be mitigated by intercalibration, however it is unclear how long the existing sensor needs to remain alongside the newly installed before there is enough overlapping data to generate a robust intercalibration. We used 154 pairs of established and newly installed sensors within the Marena, Oklahoma, In Situ Sensor Testbed to determine if there is a minimum overlap time that should be considered when planning upcoming replacements. Hourly observations of the existing sensor were linearly calibrated to those of the newly installed sensor with coefficients determined from overlap periods incremented by 30 days until a reference period of 2 years was reached. The resulting bias, root‐mean‐square error, and correlation coefficient for sensor pairs indicate that a minimum of 6 to 9 months of overlapping data are required to generate a successful intercalibration. Extending that to a full year before decommissioning the old sensor results in a stable intercalibration with higher confidence.

Agriculture

Evidence of Free-Bound Transitions in Warm Dense Matter and Their Impact on Equation-of-State Measurements

Warm dense matter (WDM) is now routinely created and probed in laboratories around the world, providing unprecedented insights into conditions achieved in stellar atmospheres, planetary interiors, and inertial confinement fusion experiments. However, the interpretation of these experiments is often filtered through models with systematic errors that are difficult to quantify. Due to the simultaneous presence of quantum degeneracy and thermal excitation, transitions in which free electrons are de-excited into thermally unoccupied bound states transferring momentum and energy to a scattered x-ray photon become viable. Here we show that such free-bound transitions are a particular feature of WDM and vanish in the limits of cold and hot temperatures. The inclusion of these transitions into the analysis of recent X-ray Thomson Scattering experiments on WDM at the National Ignition Facility and the Linac Coherent Light Source is required to obtain a physically consistent temperature from the Chihara decomposition. This interpretation is corroborated by agreement with a recently developed model-free thermometry technique and presents an important step for precisely characterizing and understanding the complex WDM state of matter.

Boehme, M [HZDR Dresden]

Interactions Between the Space Station and the Environment: A Preliminary Assessment of EMI

A review of the interactions between proposed Space Station systems/payloads and the environment that contribute to electromagnetic interference was performed. Seven prime sources of interference have been identified. These are: The Space Station power system; active experiments such as beam injection; ASTROMAG; ram and wake density gradients; pick up ions produced by vented or offgassed clouds; waves produced by current loops that include the plasma and structure; arcing from high voltage solar arrays (or possible ESD in polar orbit). This review indicates that: minimizing leakage current from the 20 kHz power system to the structure; keeping the surfaces of the Space Station structure, arrays, and radiators nonconducting; minimizing venting of payloads or systems to non-operational periods; careful placement of payloads sensitive to magnetic field perturbations or wake noise; and designing an operational timeline compatible with experiment requirement are the most effective means of minimizing the effects of this interference. High degrees of uncertainty exist in the estimates of magnitudes of gas emission induced EMI, radiation of 20 kHz and harmonics, ASTROMAG induced interference, and arc threshold/frequency of the solar array. These processes demand further attention so that mitigation efforts are properly calibrated.

G B Murphy

Heavy Element Spectroscopy in the Gas Phase

Actinides are inherently unstable and undergo nuclear decay processes with a concurrent release of energy. Consequently, they are used for nuclear power generation, nuclear weapons, and nuclear medicine. However, the radioactive decay processes also pose significant technological problems for the safe treatment and storage of spent nuclear materials. Cost-effective extraction of the actinides is the key first step in the remediation of nuclear waste, but the appropriate chemical means have yet to be determined. Our present understanding of the chemistry of actinides is limited, with the role of the 5f electrons posing a set of particularly challenging questions. The work reported here is focused on the use of electronic spectroscopy to probe the bonding of small molecules in the gas phase that contains thorium or uranium. Analyses of these data, carried out within the framework of ligand field theory, reveal clear evidence that the 5f electrons are spectators that retain their atomic metal ion character.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Microscopy modality transfer of steel microstructures: Inferring scanning electron micrographs from optical microscopy using generative AI

Scanning electron microscopy (SEM) is resource intensive, which limits its throughput in some applications. As an alternative, we propose applying computer vision and machine learning to generate high-quality synthetic SEM micrographs from micrographs obtained using light optical microscopy (LOM). Working with a correlated LOM/SEM dataset of dual-phase steel images, we test generative models of various architectures, including encoder-decoder networks, generative adversarial networks (GANs), and diffusion-based models. We find that the diffusion models significantly outperform other methods on both qualitative and quantitative assessments, while preserving key metallurgical meaning. This work establishes diffusion as the state-of-the-art for microscopy modality transfer and demonstrates the potential of AI-powered microscopy to enhance LOM with micron scale structural recreation.

Computer vision

Linear Dichroism of the Optical Properties of SnS and SnSe Van der Waals Crystals

Abstract Tin monochalcogenides SnS and SnSe, belonging to a family of Van der Waals crystals isoelectronic to black phosphorus, are known as environmentally friendly materials promising for thermoelectric conversion applications. However, they exhibit other desired functionalities, such as intrinsic linear dichroism of the optical and electronic properties originating from strongly anisotropic orthorhombic crystal structures. This property makes them perfect candidates for polarization‐sensitive photodetectors working in near‐infrared spectral range. A comprehensive study of the SnS and SnSe crystals is presented, performed by means of optical spectroscopy and photoemission spectroscopy, supported by ab initio calculations. The studies reveal the high sensitivity of the optical response of both materials to the incident light polarization, which is interpreted in terms of the electronic band dispersion and orbital composition of the electronic bands, dictating the selection rules. From the photoemission investigation the ionization potential, electron affinity and work function are determined, which are parameters crucial for the design of devices based on semiconductor heterostructures.

Chemistry

Mitigating electrochemical degradation in CsPbBr{sub 3} gamma detectors by organic and inorganic encapsulation.

CsPbBr3 perovskite semiconductors have emerged as a leading candidate for nextgeneration radiation detectors because of their exceptional charge transport properties, defect tolerance, and record-breaking sensitivity and energy resolution. Their long-term stability, however, is hindered by electrode-driven electrochemical decomposition, which is accelerated by moisture- and oxygen-assisted ion migration during operation. Here, we investigated organic and inorganic encapsulation strategies as both environmental barriers and means to suppress interfacial degradation pathways. Atomic layer deposition (ALD) of Al2O3 provided a conformal passivation layer that blocked environmental ingress, suppressed ionic diffusion, reduced leakage current, enhanced energy resolution and expanded the operational electric-field window beyond 5 kV∙cm1 . By contrast, organic encapsulants such as paraffin wax and polystyrene slowed moisture diffusion but did not suppress interfacial reactions, with wax extending stability to over 90 days. These results show that ALD-Al2O3 suppresses dominant interfacial degradation pathways, enabling stable, high-field operation and advancing the practical deployment of CsPbBr3 γ-ray detectors.

Unal, Mustafa

NASA’s Electric Propulsion Development Activities for Space Nuclear Propulsion Applications

Given increased worldwide support for advanced nuclear technology for terrestrial applications, there is a renewed interest in the possibility of nuclear-reactor-powered spacecraft. NASA continues investing in the technology areas necessary to support NASA’s future scientific and exploration goals. One of those technologies areas is electric propulsion, a highly efficient means for in-space propulsion that increases fuel economy by ionizing and accelerating an onboard propellant using spacecraft electrical power. The current NASA portfolio of electric propulsion investments in support of space nuclear applications focuses on a range of future applications with total system power levels of 50 kilowatts to multimegawatt. These investments support a fast-paced incremental rate for technology development advancement to support these applications. Systems at the 50-kilowatt power level can be accomplished today with existing technology and systems at the multimegawatt level will require further technology developments over the coming decade. Propulsion systems based an array of multiple Hall thrusters have been identified the most likely technology option for the near-term applications and systems utilizing lithium-fueled magneto-plasma-dynamic thrusters have been identified as the most promising alternative technology option for the far-term applications at very high-power levels.

Electric Propulsion

NASA’s Electric Propulsion Development Activities for Space Nuclear Propulsion Applications

Given increased worldwide support for advanced nuclear technology for terrestrial applications, there is a renewed interest in the possibility of nuclear-reactor-powered spacecraft. NASA continues investing in the technology areas necessary to support NASA’s future scientific and exploration goals. One of those technologies areas is electric propulsion, a highly efficient means for in-space propulsion that increases fuel economy by ionizing and accelerating an onboard propellant using spacecraft electrical power. The current NASA portfolio of electric propulsion investments in support of space nuclear applications focuses on a range of future applications with total system power levels of 50 kilowatts to multimegawatt. These investments support a fast-paced incremental rate for technology development advancement to support these applications. Systems at the 50-kilowatt power level can be accomplished today with existing technology and systems at the multimegawatt level will require further technology developments over the coming decade. Propulsion systems based an array of multiple Hall thrusters have been identified the most likely technology option for the near-term applications and systems utilizing lithium-fueled magneto-plasma-dynamic thrusters have been identified as the most promising alternative technology option for the far-term applications at very high-power levels.

Electric propulsion

Atmospheric, Non-Combusting Droplet Sizing and Spray Imaging Results From a Non-Proprietary Aero Gas Turbine Engine Pressure Swirl Atomizer using Shadowgraphy and Planar Laser Scatter

Members from industry and federal agencies of the United States have developed a collaborating group focused on improving the understanding of the atomization processes common to gas turbine engines. The group is aimed on providing high quality data using x-ray diagnostics in the internal geometry and the near-field dense spray as well as optical diagnostics in the visible spectrum, downstream of the nozzle. This paper reports results from one of the two non-proprietary injectors designs from the group: the primary-secondary injector. In particular, we characterize the spray from only the primary, pressure-swirl atomizing circuit using water through the nozzle. We observed Sauter mean diameter decreased with increased water pressure drop across the nozzle. SMD was also collected at three axial distances and showed decreased size with distance from the nozzle. Planar laser sheet droplet scattering provided qualitative assessment of the spray. Higher water pressure drops provided better atomization than lower pressure drops. The addition of swirling air flow through the injector alleviates and improves the atomization quality, particularly at the lower water pressure drops.

optical diagnostics

Comparative Assessment of Battery Carbon Footprint Calculation Frameworks to Support U.S. Battery Manufacturing

A “battery passport” is a digital record that provides comprehensive information about an individual battery across its life cycle. This concept has been introduced by Battery Regulation (EU) 2023/1542 [1], which applies to batteries for electric vehicles (EVs), industrial batteries with a capacities greater than 2 kWh, and batteries for light means of transport (LMT) greater than 2kWh sold in the European Union (EU) market – impacting manufacturers and exporters across multiple jurisdictions globally. Among its reporting mandates, a key feature of battery passports is the requirement for a carbon footprint (CF) calculation methodology supported by enhanced data granularity to enable traceable and verifiable CF results. While no other jurisdictions have yet adopted formal battery passport requirements like the EU’s, some are developing CF calculation methods to comply with the EU Battery Regulation or are creating CF-related regulations that could evolve in a similar direction, reflecting the growing importance of battery CF guidelines for manufacturers seeking to remain competitive in global markets.

Zhang, Jingyi [Argonne National Laboratory (ANL),

Weak, shallow, dry convection over Angola increases offshore stratocumulus cloud droplet number concentrations

Boundary-layer cloud interactions involving shortwave-absorbing aerosols remain one of the least understood aerosol influences on climate. Here, we find the highest stratocumulus cloud droplet number concentrations over the southeast Atlantic occur when agricultural fires coincide with synoptically-weakened surface warming over Angola, occurring June-early August. Dry convection fills a shallow continental boundary layer with smoke, and a nighttime (local solar time 2-9) land breeze transports the aerosol into the marine boundary layer. Offshore aerosol transport is strengthened by low-level easterlies from a continental pressure high southeast of Angola. Simultaneously, the South Atlantic subtropical high is weaker, allowing extensive dispersal of aerosol offshore into the boundary layer, obscuring cloud brightening from shipping. Meteorological co-variation at synoptic scales compensates for cloud brightening by the smoke. Outgoing shortwave radiation increases by 15–20% of the monthly mean in June and July when offshore droplet numbers are less but the stratocumulus deck is more developed.

54 ENVIRONMENTAL SCIENCES