Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “material irradiation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Effect of cryogenic irradiation on NERVA structural alloys

Several alloys (Hastelloy X, AISI 347, A-286 bolts, Inconel 718, Al 7039-T63 and Ti-5Al-2.5Sn ELI) were irradiated in liquid nitrogen (140 R) to neutron fluences between 10 to the 17th power and 10 to the 19th power nvt (E greater than 1.0 Mev). After irradiation, tensile properties were obtained in liquid nitrogen without permitting any warmup except for some specimens which were annealed at 540 R. The usual trend of radiation damage typical for materials irradiated at and above room temperature was observed, such as an increase in strength and decrease in ductility. However, the damage at 140 R was greater because this temperature prevented the annealing of radiation-induced defects which occurs above 140 R.

Dixon, C. E.↗

AGC-4 Disassembly Report

The Advanced Reactor Terminology Graphite Research and Development program is currently measuring irradiated material property changes in several grades of nuclear graphite to predict behavior and operating performance within the core of these new high temperature reactor designs. The Advanced Graphite Creep (AGC) experiment, consisting of six irradiation capsules, will generate the irradiated graphite performance data for the Very High Temperature Reactor operating conditions. All six capsules in the experiment conducted at Idaho National Laboratory will be irradiated in the Advanced Test Reactor, disassembled in the Hot Fuel Examination Facility, and examined at the Idaho National Laboratory Research Center. This is the disassembly report describing the disassembly, shipment, post irradiation inspection, and storage of the graphite specimens contained within the AGC 4 irradiation test series capsule (the fourth irradiation capsule of the series). AGC 4 was irradiated in the Advanced Test Reactor (ATR) East Flux Trap (EFT) during ATR Cycle 157D, 158A, 162A, 162B, 164A, 164B, 166A, and Cycle 166B. Approximately 3.6 dpa was achieved. Desired experiment temperatures were exceeded by at least 100C during the second Cycle of irradiation due to the insertion of the KJRR experiment. The capsule was removed from the ATR and transferred to the Hot Fuel Examination Facility on May 15, 2020 and eventually unloaded into the Hot Fuel Examination Facility (HFEF) Decon Cell through Penetration 2D on February 26, 2021. It was moved to the HFEF Main Cell Window 3M for disassembly on March 15, 2021. Disassembly and specimen extraction began March 18, 2021, and packaging of the graphite specimens was completed on April 16, 2021. Several anomalies were noted, specifically that the radiological dose rates were nominally an order of magnitude higher than that of the previous AGC experiments. This report summarizes the disassembly of the AGC 4 experiment.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

AGC-4 Disassembly Report

The Advanced Reactor Terminology Graphite Research and Development program is currently measuring irradiated material property changes in several grades of nuclear graphite to predict behavior and operating performance within the core of these new high temperature reactor designs. The Advanced Graphite Creep (AGC) experiment, consisting of six irradiation capsules, will generate the irradiated graphite performance data for the Very High Temperature Reactor operating conditions. All six capsules in the experiment conducted at Idaho National Laboratory will be irradiated in the Advanced Test Reactor, disassembled in the Hot Fuel Examination Facility, and examined at the Idaho National Laboratory Research Center. This is the disassembly report describing the disassembly, shipment, post irradiation inspection, and storage of the graphite specimens contained within the AGC 4 irradiation test series capsule (the fourth irradiation capsule of the series). AGC 4 was irradiated in the Advanced Test Reactor (ATR) East Flux Trap (EFT) during ATR Cycle 157D, 158A, 162A, 162B, 164A, 164B, 166A, and Cycle 166B. Approximately 3.6 dpa was achieved. Desired experiment temperatures were exceeded by at least 100C during the second Cycle of irradiation due to the insertion of the KJRR experiment. The capsule was removed from the ATR and transferred to the Hot Fuel Examination Facility on May 15, 2020 and eventually unloaded into the Hot Fuel Examination Facility (HFEF) Decon Cell through Penetration 2D on February 26, 2021. It was moved to the HFEF Main Cell Window 3M for disassembly on March 15, 2021. Disassembly and specimen extraction began March 18, 2021, and packaging of the graphite specimens was completed on April 16, 2021. Several anomalies were noted, specifically that the radiological dose rates were nominally an order of magnitude higher than that of the previous AGC experiments. This report summarizes the disassembly of the AGC 4 experiment.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Survey of U.S. Research Reactor Auxiliary Facilities Used for Material Testing and Basic Neutron Science

A catalogue of and attributes of the Materials Irradiation and Testing facilities (MIF) and the Basic Neutron Science facilities (BSF) of auxiliary (AUX) facilities of research reactors are compiled. The survey of these facilities is drawn from the set of U.S. university and DOE research reactor facilities and should be considered as a reference point when comparing commonalities in international AUX facilities. The size and shielding capabilities of the facilities, the typical characterization equipment used, and the neutron flux and irradiation capabilities of the facilities are listed. Short descriptions of experimental activities and current practices are detailed for MIFs and BSFs. The attributes are important in consideration of the reconfiguration of the facilities for purposes other than stated mission, i.e., for proliferation of weapons-usable nuclear material (WUNM). An evaluation of the capacity for production rate of WUNM from neutron beams-on-targets or a sample that has been placed in an irradiation position for a period is provided. Further evaluation of reconfiguration of these MIF and BSF are recommended to refine the proliferation risks. Specifically, MIF hot cells and potential configurations, additional modeling of facility throughput and development of methods for determining levels of concern for MIF and BSF have all been identified as steps for refinement of determination of the risks associated with these facilities. Future work will focus on: 1. A model of projected throughput for different MIF and BSF configurations that will be used to provide a window of potential operational misuse for a facility and better understand the capability of production and the rate of processing for WUNM in these facilities. 2. A misuse study for various configurations of MIF hot cell layouts detailing capacity, specifications, shielding constraints for MIF operations, identification of a maximum shielding thickness, and reasonable need associated with each activity performed in a MIF. 3. Development of a rule of thumb rating system utilizing data gathered from previous reports to show levels of concern at a given power level, flux, and experiment set.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Degradation of graphite-epoxy due to electron radiation

Experimental results are presented showing that electron irradiation has a variable effect on the properties of graphite-epoxy depending upon the test temperature and the property of interest. In general, compression properties are improved at cold temperature and degraded at elevated temperature. With the exception of some moduli, tensile and shear properties are degraded at both cold and elevated temperatures. Electron irradiation lowers the glass transition temperature of graphite/epoxy significantly. Property degradation of irradiated materials at the elevated temperature is associated with the reduction in Tg. It is shown that a (0) compression-strength test is the most sensitive test for exhibiting the effects of electron irradiation. Results from tests on neat resin also show that the bulk matrix is degraded after irradiation, and that the correlation between resin and composite response is good.

Herakovich, C. T.↗

The microstructure effects on irradiation response of ferritic – martensitic steels

Microstructural optimization to achieve greater mechanical strength has been one of the focuses in ferritic–martensitic steels development. However, these optimized microstructures’ effects on the radiation response are not well known. In this work, two ferritic–martensitic steels (9Cr-NbMo and 9Cr-Ta) underwent neutron irradiation in the High Flux Isotope Reactor, and their room-temperature post-irradiation tensile properties and microstructure evolutions were investigated and compared. These two steels exhibit similar pre-irradiation tensile behavior, and their yield strengths are higher than that of other ferritic–martensitic steels by about 200–250 MPa. Microstructural characterization on pre-irradiated materials reveals a smaller grain size in 9Cr-Ta (2.8 ± 0.3 μm in 9Cr-Ta versus 4.3 ± 0.5 μm in 9Cr-NbMo) but higher dislocation density and precipitate density in 9Cr-NbMo. As is common for ferritic–martensitic steels at low irradiation temperatures (less than about 0.45T m ), irradiation-induced hardening at 400 °C was observed for both alloys. Irradiation at 490 °C causes the two alloys to exhibit different tensile behavior: 9Cr-Ta softens by 208 MPa in yield stress, whereas 9Cr-NbMo maintains strength. Additionally, microstructural characterizations were performed, including precipitate growth, dislocation, and defect formation. Using the barrier hardening model for microstructure–property correlation, the softening in irradiated 9Cr-Ta is primarily attributed to the significant dislocation recovery, while the strength lost from the slight dislocation recovery in 9Cr-NbMo was compensated by the additional strength from the irradiation-induced cavities. The microstructure effect (primarily precipitate, dislocation and boundary) on the radiation response is discussed herein.

36 MATERIALS SCIENCE↗

Focused Ion Beam Tomography of Alloy 617 Corroded in Molten Chloride Salt

Materials qualification of reactor structural materials is a critical step in rapid implementation of advanced nuclear reactor technologies, particularly to assess the corrosion performance in these designs. Accelerated qualification of reactor structural materials requires incorporating powerful computational toolsets, such as phase field modelling in the Multiphysics Object-Oriented Simulation Environment (MOOSE) framework, to predict the evolution of structural materials due to corrosion. Accordingly, computational toolsets will require experimental data generated at appropriate length scales to validate accuracy. Focused ion beam (FIB) provides a high degree of control over manipulation of materials for analytical purposes, including capturing data on the evolution in the microstructure and elemental composition of materials at the mesoscale, an appropriate length scale for phase field modelling of intergranular diffusion phenomena using the MOOSE framework. For instance, the FEI Helios G4 UX dual beam plasma FIB microscope at the Irradiated Materials Characterization Laboratory (IMCL) is capable of backscatter diffraction (EBSD) and energy-dispersive x-ray spectroscopy (EDS) documenting the evolution in the microstructure and elemental composition, respectively. The Helios can perform EDS and EBSD three-dimensionally (3D) using tomography, which is then combined using different software packages to visualize 3D volumes correlating elemental composition to microstructural data. The purpose of this investigation was to develop a streamlined characterization and data processing workflow for 3D tomography studies on the FEI Helios G4 plasma FIB. The investigation is segmented into three parts: 1) Optimizing the data collection workflow, 2) identifying appropriate data processing and visualization software (i.e. DREAM.3D, MIPAR, and VGStudioMax), and 3) establishing an infrastructure for public release. The optimization of the data collection workflow is in collaboration with members of the U220 department to setup formal training on the tomography operation of the G4, through ThermoFisher Scientific, and exploring DREAM.3D, MIPAR, and VGStudioMax data processing/visualization software packages. VGStudioMax currently demonstrates the most promise for future use. Optimization of the data collection and processing workflow is still ongoing. A collaboration with INL High Performance Computing (HPC) established an open-source license for expediting the public release of FIB tomography datasets through HPC. FIB tomography data generated by the G4 will provide comprehensive data for validating 3D phase field mesoscale modelling tools within the MOOSE framework for accelerated qualification of reactor structural materials.

Copeland-Johnson, Trishelle↗

HFIR Activity Workbook Generator (HAWK) User Guide

The HFIR Activity WorkbooK generator (HAWK) is a Python code that automates and streamlines the activity calculation of samples after irradiation in the High Flux Isotope Reactor (HFIR). HAWK’s results provide estimates of the activity and nuclide inventory of irradiated specimens before they are moved to hot cell facilities, where they undergo post-irradiation examination. The samples’ activity results guide the packing of shipping containers and inform the accountable inventories for the hot cell facilities. The toolkit was originally developed by Charles Daily, a former R&D staff member at Oak Ridge National Laboratory (ORNL). As of May 2025, HAWK is developed by the Radiation Transport & HPC Methods Group (Nuclear Energy and Fuel Cycle Division) at ORNL. Figure 1 presents HAWK’s workflow. To use HAWK, users need to: 1. Develop an Excel input workbook (i.e., XLSX extension) containing data from the experiment’s materials, irradiation history (cycles), and irradiation positions. 2. Make minor edits to an existing template JSON file (i.e., auxiliary_data.JSON) and to the Python driver. The driver sets the necessary environment variables, defines the material compositions, and ultimately calls HAWK. Once configured, HAWK runs the Oak Ridge Isotope Generation code (ORIGEN) to calculate the masses, activities, and heat load at the end of irradiation for each isotope in the specimen. ORIGEN is part of SCALE, ORNL’s in-house computational tool for performing nuclear safety and design calculations. Following this step, HAWK postprocesses the results and generates three output workbooks summarizing the activity calculations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A space simulation test chamber development for the investigation of radiometric properties of materials

The design, fabrication, and preliminary utilization of a thermal vacuum space simulation facility are discussed. The facility was required to perform studies on the thermal radiation properties of materials. A test chamber was designed to provide high pumping speed, low pressure, a low photon level radiation background (via high emissivity, coated, finned cryopanels), internal heat sources for rapid warmup, and rotary and linear motion of the irradiated materials specimen. The radiation detection system consists of two wideband infrared photoconductive detectors, their cryogenic coolers, a cryogenic-cooled blackbody source, and a cryogenic-cooled optical radiation modulator.

Enlow, D. L.↗

Parallel Dislocation Simulator

ParaDiS, or Parallel Dislocation Simulator, is a simulation tool that performs direct numerical simulation of dislocation ensembles, the carriers of plasticity, to predict the strength in crystalline materials from the fundamental physics of defect motion, evolution, and interaction. The code has been successfully deployed on high performance computing architectures and used to study the origins of strength and strain hardening for cubic crystals, the strength of micro-pillars, and irradiated materials at LLNL. The ParaDiS code has been successfully deployed on more than one hundred thousand CPU's with over ten million active degrees of freedom.

Bulatov, Vasily↗

Failure evaluation of neutron-irradiated SiC/SiC composites by underwater acoustic emission

Here, understanding the statistical properties of mechanical properties of non-irradiated and neutron-irradiated SiC/SiC composites is essential for component design. This study aims to evaluate the detailed damage accumulation behavior of composites focusing on two fracture parameters: proportional limit stress (PLS) and acoustic emission (AE) onset stress. The developmental underwater AE technique, which is benefit in non-contact in-situ failure monitoring method during mechanical testing and in handle of the irradiated material, was first applied to evaluate damage accumulation behavior. Two types of chemical vapor infiltration SiC/SiC composites were used: one reinforced with Hi-Nicalon Type-S SiC fiber and one reinforced with Tyranno-SA3 SiC fiber in the form of satin-woven 2D fabrics with pyrolytic carbon interface. Neutron irradiation in the High Flux Isotope Reactor at Oak Ridge National Laboratory reached a fluence of 30 dpa at a temperature of 620–670°C. Four-point flexural tests were conducted to evaluate post-irradiation strength. Weibull statistics did not suggest marked degradation of composite strength. Detailed failure behavior evaluated by AE demonstrated no irradiation-induced change of the AE onset stress (i.e., crack initiation equivalent stress). Failure probability analysis suggests that increasing the reliability of composites (i.e., the Weibull modulus rather than strength itself) is essential to expanding the design margin and benefiting from a probabilistic design approach.

36 MATERIALS SCIENCE↗

MPEX High Heat Flux Plasma Dump Design, Manufacture, and Articles Test

Here, the Material Plasma Exposure eXperiment (MPEX) device is a steady-state linear plasma device currently in the final design phase at the Oak Ridge National Laboratory. This device will reach ion fluences up to 10 31 m -2 and will be used to expose neutron-irradiated materials to divertor-relevant plasmas and to study the effects of plasma-material interactions. These studies will elucidate the complex effects of plasmas with divertor candidate materials capable of withstanding high heat flux and high fluences for next-generation fusion devices. Bidirectional plasma will be generated using a high-power (200 kW) helicon source. Plasma will be confined by superconducting magnets. The last plasma-facing component on the upstream side of the MPEX device is the dump, which has been designed to intercept plasma and energetic particles. The dump will have a total heat load of 9.2 kW. A copper alloy (Glidcop AL-15) was selected for use in the water-cooled flange design because of its high thermal conductivity, its retaining strength at elevated temperatures, and its ability to be used in the high-temperature braze joints used in this application. Titanium-zirconium-molybdenum (TZM) tiles are brazed to the Glidcop AL-15 flange using high-temperature braze alloy. External water-cooling channels are used on the dump flange to prevent water leakage inside the vacuum space. This article discusses the details of the high heat flux dump design, including the computational fluid dynamics (CFD) and structural analyses performed to validate the design to meet the operational requirements of the MPEX device.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Inorganic chemical investigation by X-ray fluorescence analysis - The Viking Mars Lander

The inorganic chemical investigation experiment added in August 1972 to the Viking Lander scientific package uses an energy-dispersive X-ray fluorescence spectrometer in which four sealed, gas-filled proportional counters detect X-rays emitted from samples of the Martian surface materials irradiated by X-rays from radioisotope sources (Fe-55 and Cd-109). The instrument is inside the Lander body, and samples are to be delivered to it by the Viking Lander Surface Sampler. Instrument design is described along with details of the data processing and analysis procedures. The results of the investigation will characterize the surface materials of Mars as to elemental composition with accuracies ranging from a few tens of parts per million (at the trace-element level) to a few per cent (for major elements) depending on the element in question.

Toulmin, P., III↗

Thermal Conductivity Degradation in High Burnup U-Pu-Zr Fuel

Recent advancements in the characterization of irradiated U-Pu-Zr fuels have revealed complexities that challenge existing understanding of constituent redistribution. Traditionally, models have proposed three concentric regions within the fuel, each characterized by distinctive phases and porosity. However, through detailed analysis of high burnup U-Pu-Zr, we discovered the presence of four distinct constituent redistribution regions. Particularly novel is the observation of significant Pu redistribution, a previously unreported phenomenon that necessitates a reevaluation of current models. This work aims to delve deeper into these findings, seeking to correlate mesoscale measurements of thermal diffusivity and respective thermal conductivity with the phases present in each redistribution region. To achieve this objective, we employed mesoscale thermoreflectance methods using the unique, Idaho National Laboratory (INL) developed, Thermal Conductivity Microscope (TCM) at INL’s Irradiated Materials Characterization Laboratory. The TCM employs two tightly focused lasers: one for heating to generate periodic thermal waves in the substrate, and another spatially separated probe laser to detect changes in the optical reflectivity of the gold-coated substrate resulting from thermal wave diffusion. We conducted several thermal diffusivity measurements within each region of constituent redistribution of a U-19Pu-10Zr fuel pin cross section irradiated to 11 at. % burnup. The TCM measurement positions strategically aligned with transmission electron microscopy (TEM) lift-out locations previously collected from the fuel sample. Complementary microstructural analysis techniques such as optical and scanning electron microscopy (OM/SEM), electron probe microanalysis for chemical compositions, and TEM-based selective area electron diffraction (SAED) analysis for crystallographic insights into each phase were also utilized. This comprehensive approach allowed us to correlate local thermal diffusivity data with microstructural characteristics, enabling the computation of local thermal conductivity at each position. The significance of this contribution lies in its pioneering use of the TCM for ternary fuel mesoscale examination, shedding light on the previously overlooked effects of Pu redistribution on local thermal conductivity. By informing current models capturing constituent redistribution and heat transfer, our findings pave the way for more accurate predictions of metallic fuel performance. Moreover, this work sets the stage for future comparisons with similar TCM examinations on U-19Pu-10Zr fuels at ultra-low burnup, facilitating a comprehensive understanding of thermal property changes across different burnup levels. Ultimately, our study not only enriches our understanding of the thermophysical properties of individual redistribution regions within U-Pu-Zr fuel but also offers valuable insights for the design and operational parameters of proposed next-generation fast reactors.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Mn-53 profiles in four Apollo surface cores

Mn-53 data are presented for four Apollo cores with an emphasis on the past 10-to-the-7th-year history of these samples: (1) Core 15011 has excess Mn-53 down to a depth of at least 9 cm, which is probably due to the continuous addition of near-surface irradiated material. (2) The Mn-53 profile for 64002 above 12 cm is relatively flat and in excess of that calculated for a static core, which suggests that the upper part of this core was deposited rapidly about 2 m.y. ago. (3) Results for the Apollo 17 drill stem show a large excess of Mn-53 from at least 3 cm downwards. Some magnetic separates obtained from this core have very high Mn-53 activities, probably due to the presence of agglutinates that were recently irradiated very near the surface. (4) The Mn-53 content of the upper part of 74002 is similar to that of trench samples collected nearby and indicates that the gray, orange, and black soils at this site have been exposed together near the surface for at least the last 10 m.y.

Nishiizumi, K.↗

Imaging and Analysis of Insoluble Electrorefiner Material

Throughout pyroprocessing efforts at the Hot Fuel Examination Facility (HFEF), insoluble material has accumulated in the Electrorefiner (ER) vessel. The objective of this effort was to analyze the accumulated material to determine its origin. Material was removed from the ER salt bath and distilled to remove excess salt prior to performing analysis. Three samples were sent for chemical and isotopic analysis and underwent an ethyl acetate-bromine dissolution to segregate the oxide fraction from the metal fraction. Actinide concentrations were determined using a quadrupole–inductively coupled plasma–mass spectrometer (Q-ICP-MS). Three additional samples were sent for morphologic and elemental analysis by scanning electron microscopy (SEM) with Energy Dispersive X-ray (EDX) analysis at the Irradiated Materials Characterization Laboratory (IMCL). Analyses suggest that the material is primarily composed of UO2. with a small fraction of metal. This study draws no single conclusion as to the origin of the insoluble material in the ER. The particle sizes and morphologies observed in SEM micrographs indicate that the larger particles observed may be a result of introducing material to the ER that has not been completely reduced in Oxide Reduction (OR) operations, which precede electrorefining. Smaller particles may be due to reactions with oxygen and moisture present in HFEF. This research suggests that microscopic analysis of fuel particles before and after OR operations (including after distillation) as well as the uranium product collected on the cathode in the ER would increase understanding about particle morphology within the pyrochemical process.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Quantifying dislocation-type defects in post irradiation examination via transfer learning

The quantitative analysis of dislocation-type defects in irradiated materials is critical to materials characterization in the nuclear energy industry. The conventional approach of an instrument scientist manually identifying any dislocation defects is both time-consuming and subjective, thereby potentially introducing inconsistencies in the quantification. This work approaches dislocation-type defect identification and segmentation using a standard open-source computer vision model, YOLO11, that leverages transfer learning to create a highly effective dislocation defect quantification tool while using only a minimal number of annotated micrographs for training. This model demonstrates the ability to segment both dislocation lines and loops concurrently in micrographs with high pixel noise levels and on two alloys not represented in the training set. Inference of dislocation defects using transmission electron microscopy on three different irradiated alloys relevant to the nuclear energy industry are examined in this work with widely varying pixel noise levels and with completely unrelated composition and dislocation formations for practical post irradiation examination analysis. Code and models are available at https://github.com/idaholab/PANDA.

36 MATERIALS SCIENCE↗