Estimation of the Thermal-Fluids and Thermal-Structural Performance of Helium-Cooled Modular Finger-Type Divertors

Over the past decade, our group has investigated the thermal-fluid performance of the helium-cooled modular divertor with multiple jets (HEMJ) and a simplified “flat” design of the HEMJ for long-pulse magnetic fusion energy (MFE) reactors. Experimental studies were performed in a helium (He) loop at the prototypical pressure of 10 MPa, nearly prototypical He temperatures and incident heat fluxes using test sections made from stainless steel and tungsten alloys. Correlations for average Nusselt numbers and pressure loss coefficients were developed from the data and are used to validate computational fluid dynamics (CFD) models. Here, this work presents updated thermal-fluids performance curves based on these correlations that estimate the maximum heat flux that can be accommodated by the plasma-facing surface and coolant pumping power requirements at prototypical operating conditions. Thermal-structural performance curves developed from ITER structural design criteria are introduced, which include protection against ductile and non-ductile failure, ratcheting fatigue, and creep fatigue. The performance design curves for these finger-type divertors demonstrate that the “flat” design, with a significantly less complicated geometry than the HEMJ, has thermal-fluid and thermal-structural performance comparable to the original HEMJ concept, and may be superior in terms of non-ductile failure criteria.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Long wavelength interband cascade lasers

InAs-based interband cascade lasers (ICLs) can be more easily adapted toward long wavelength operation than their GaSb counterparts. Devices made from two recent ICL wafers with an advanced waveguide structure are reported, which demonstrate improved device performance in terms of reduced threshold current densities for ICLs near 11 μm or extended operating wavelength beyond 13 μm. Here, the ICLs near 11 μm yielded a significantly reduced continuous wave (cw) lasing threshold of 23 A/cm 2 at 80 K with substantially increased cw output power, compared with previously reported ICLs at similar wavelengths. ICLs made from the second wafer incorporated an innovative quantum well active region, comprised of InAsP layers, and lased in the pulsed-mode up to 120 K at 13.2 μm, which is the longest wavelength achieved for III–V interband lasers.

47 OTHER INSTRUMENTATION↗

Design of the EIC hadron storage ring stripline injection kicker with a novel impedance tuning capability

The Electron-Ion Collider (EIC), to be built at Brookhaven National Laboratory, will be a high luminosity (~10 34 cm –2 s –1 ) nuclear science facility. To facilitate EIC experiments, the existing yellow ring of the Relativistic Heavy Ion Collider (RHIC) will be reconfigured to serve as the Hadron Storage Ring (HSR). Designing a stripline injection kicker for the HSR beams, with high magnetic rigidity (~ 82 Tm), poses some technical challenges due to the required large pulsed voltage with long flattop duration, very fast rise time, expected shorter bunch spacing, and potential heating due to higher peak current. In addition, minimizing impedance mismatch in the transition region between the feedthrough and the stripline electrode is challenging. This paper focuses on the mechanical design and optimization of the HSR injection kicker, highlighting a novel impedance tuning capability achieved through an innovative kicker aperture adjustment mechanism. We comprehensively cover the design, including impedance optimization (both beam coupling and characteristic), beam-induced heating, and thermal analysis, and investigation of the maximum electric field due to high voltage signal excitation to ensure safe and reliable operation.

43 PARTICLE ACCELERATORS↗

A machine learning approach for particle accelerator errant beam prediction using spatial phase deviation

Particle accelerators are extremely complex systems that are expected to operate on high availability. Predicting impending failures only by utilizing data collected from diagnostic equipment already on board can help operators to avoid installing expensive sensors, unscheduled downtime and associated costs. For this purpose we explore the predictive power of Machine Learning algorithms to detect faulty beams prior to the failure. In this study, we propose a Machine Learning approach to model mapping from a pair of sensors located across the accelerator. While the model is trained to represent normal operation, we evaluate the predictive performance on known faulty beam pulses. We also investigate the model performance on unseen data through k-fold cross-validation. Then we recap the analysis with a neural architecture search and hyperparameter optimization study to fine tune our initial model. In conclusion, this paper will also introduce a sustainable framework that can standardize Machine Learning workflow applied to particle accelerators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Statistically elucidated responses from low-signal contrast mechanisms in ultrafast electron microscopy

The emergence of ultrafast electron microscopy (UEM) has enabled the discovery of strongly correlated dynamic mechanisms, including electron–phonon coupling, structural phase transitions, thermal transport, and electromagnetic deflection. Most UEM systems operate stroboscopically, meaning that the technique is susceptible to artifacts, mistakes, and misinterpretation of the data due to extensive experimental effort. In contrast to the ultrafast designation, data acquisition is extraordinarily slow because the electron beam has significantly reduced signal compared to traditional transmission electron microscopy due to pulsing the electron beam. Consequently, the sample may drift, tilt, or undergo irreversible structural changes that are independent of the time-resolved dynamics throughout the experimental time frame. Furthermore, these datasets require significant user interpretation that can be problematic when proper controls are not implemented thoroughly. Here, we demonstrate a new algorithm designed to separate ultrafast structural dynamics from long-term artifacts using a LiNbO 3 sample experiencing electrically driven surface acoustic wave propagation. Additionally, we provide examples of the impact of user bias when analyzing the data and provide a methodology, which enables the extraction of time-resolved responses when the image signal is extraordinarily low. Overall, the goal of this publication is to provide methods that validate the experimental results and reduce researcher biases during UEM data interpretation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Commissioning, Performance, and Effect of the Quench Current-Boosting Device on a Dedicated Superconducting Magnet

Superconducting magnet training is one of the accelerator related issues attracting attention due to significant operational costs and time budget associated to it. It is especially worrisome that magnets based on the “next-generation” Nb 3 Sn technology are affected by long training. While various efforts are underway to better understand and resolve the problem a parallel path could also be investigated, a path bypassing the issue. Following the concept of fast induced over-current during magnet powering, FNAL has developed an upgradable capacitor-based device to discharge through a superconducting magnet at quench detection or operator chosen time. The 0.4 F/1 kV device has been tested on a 1-m-long dipole-coil in a “mirror” magnet configuration and conclusive results on magnet training elimination have been observed. Here in this paper we discuss the main characteristics of the device, compare simulated response and actual performance, elaborate on test drivers and outcomes. Next steps and perspectives for future use are debated.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Impact of Electrode Thickness and Temperature on the Rate Capability of Li 4 Ti 5 O 12 /LiMn 2 O 4 Cells

Growing demand for stationary energy storage systems requires the development of low cost, long cycle life, safe batteries. Lithium-ion batteries (LiBs) utilizing Li 4 Ti 5 O 12 /LiMn 2 O 4 (LMO) cathode are promising candidates providing critical-material-free chemistry, high power capability, and long lifespan. However, their low energy density is a major drawback. In this work, we evaluate the rate performance of LTO/LMO cells fabricated with electrode loadings from 1.7 to 4.2 mAh cm -2 toward the development of high energy density and low cost LTO/LMO cells. The operating temperature is varied from 30 °C to 55 °C to evaluate the impact of electrode thickness vs temperature limitations on the electrode utilization. In addition, Newman modeling is performed to provide detailed understandings of the cell performance. Combining experimental and simulated results, we show the rate capability of the thicker electrodes is limited by the electrolyte transport. When the cells are discharged by applying pulsed current, Li + ion depletion is mitigated and the discharge capacity increases. Thus, high energy density LTO/LMO cells for BTMS applications can operate more efficiently when intermittent rest is applied. Finally, overcoming electrolyte transport limitations will be the key to enabling the development of high energy density LTO/LMO cells using thick electrodes.

25 ENERGY STORAGE↗

Laser-assisted high-energy proton pulse extraction for feasibility study of co-located muon source at the SNS

Here, we have experimentally demonstrated the first non-intrusive 1-GeV proton beam extraction for the generation of muons with a temporal structure optimized for Muon Spin Relaxation/Rotation/Resonance (μSR) applications. The proton pulses are extracted based on the laser neutralization of 1 GeV hydrogen ion (H - ) beam in the high energy beam transport of the Spallation Neutron Source (SNS) accelerator. The maximum flux of the extracted proton beam based on laser neutralization causes only 0.2% reduction of the total proton beam used for neutron production, a marked difference from the 20% reduction at other co-located muon and neutron facilities, and thus the proposed method will result in negligible impact on the SNS operation. This paper describes the development of a fiber/solid-state hybrid laser system that has high flexibility of pulse structure and output power, initial experiments on laser neutralization of beam and separation of H 0 beam from the existing SNS accelerator beam line, conversion of H 0 to proton at the SNS linac dump, and measurement results of 30 ns/50 kHz proton pulses. This system conclusively demonstrates the feasibility of laser-based proton beam extraction to power a world-leading μSR facility at the SNS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Vacuum commissioning and operation result after the KSTAR PFC upgrade

The first vacuum commissioning after the installation of new tungsten mono-block cassette divertor has been successfully conducted in KSTAR. The tungsten divertor has been installed in the lower divertor region to handle the high divertor heat loads up to 10 MW/m 2 . On the one hand, the plasma facing components except for the tungsten divertor in the KSTAR vacuum vessel still consists of graphite tiles. Thus, it was much more challenging to maintain high-quality vacuum condition mainly because of various possible impurity sources inside the vessel compared with previous experiment campaigns. In this paper, the detailed procedure for securing vacuum condition of the KSTAR tokamak after the installation of the new tungsten divertor is presented. The vacuum condition is also examined regarding the plasma start-up and the long-pulse high-performance quality.

KSTAR↗

A computational model for nanosecond pulse laser-plasma interactions

A multi-physics numerical model for laser-induced optical breakdown and laser-plasma interaction in a non-equilibrium gas is presented, accounting for: production of priming electrons via multi-photon ionization, energy absorption, cascade ionization, induced hydrodynamic response, and shock formation and propagation. The gas is governed by the Navier-Stokes equations, with non-equilibrium effects taken into account by means of a two-temperature model. The space-time dependence of the laser beam is modeled with a flux-tube formulation for the Radiative Transfer Equation. The flow governing equations are discretized in space using a second-order finite volume method. The semi-discrete equations are marched in time using an implicit-explicit (IMEX) dual time-stepping strategy, where diffusion and chemistry are solved implicitly, whereas convection is explicit. Application to a 20 ns long 50 mJ pulse laser-induced breakdown in quiescent O 2 shows the advantages of this temporal discretization during and just after the laser pulse, while a less-expensive symmetric Strang splitting (with implicit chemistry) is sufficient for the post-breakdown gas dynamics after ≃ 0.1 μs. The integrated model is shown to reproduce key features of corresponding experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High Yield Xray Imager Final Design Review

The High Yield Xray Imager (HYXI) is a new NIF target diagnostic system currently under development. The goal of HYXI is to provide high-fidelity, high temporal resolution x-ray imaging capability on high yield NIF implosions at 10MJ and above. The HYXI instrument design concept is based on the combination of two technologies that have been successfully utilized at the NIF on previous instruments, electron pulse-dilation and hybrid-CMOS sensor imaging. The combination of these two techniques will give HYXI sufficient data quality to ascertain differences in hot spot formation dynamics between high and low yield implosions. This information will highlight the critical hot spot conditions needed for ignition and burn. The HYXI design leverages the successful operation of the PDIXI x-ray imager at the NIF on multi MJ yield shots. A new radiation tolerant CMOS imaging array (HYPERION) is being developed to eliminate the significant background noise which limits the data quality of PDIXI. We successfully placed the contract with Advanced hCMOS Systems (AHS) to develop the HYPERION sensor, which fulfils our criteria to place long lead time item procurements by end of FY24. The HYXI Final Design Review was completed at the end of Q4 FY24 (Sep 24 th and Sep 30 th ). The HYXI project is a multi-year effort with a phased approach to be bring up system functionality over time in parallel with the development and fabrication effort of the HYPERION CMOS imaging array. In Phase 1, time-integrated x-ray images on NIF DT experiments will be collected starting in Q3 FY25. In Phase 2 of the project, time-resolved imaging with HYXI utilizing a spare microchannel plate detector back-end will begin in Q3 FY26. Phase 3 concludes the project with the installation of the HYPERION sensor array and the final performance qualification of the HYXI instrument which is scheduled for Q3 FY27 as discussed in the PDR and MRT report on this project in FY23.

42 ENGINEERING↗

Development of a liquid-helium free cryogenic sample holder with mK temperature control for autonomous electron microscopy

The automated and autonomous cryogenic transmission electron microscopy (Cryo-EM) demands a sample holder capable of maintaining temperatures below 10 K with precise control, long holding times, and minimal helium use. Rising to this challenge, we initiated an ambitious project to develop a novel closed-cycle cryocooler-based cryogenic sample holder that operates without the use of liquid helium and the consumption of gaseous helium. Here, this article presents the design, construction, and experimental testing of the initial prototype, which achieves an ultimate temperature of 5.6 K with exceptional stability close to 1mK, while providing a wide temperature control range from 295 K to 5.6 K, marking a clear advancement in cryo-EM holder development. While the prototype was not designed for atomic resolution imaging and thus lacks a sturdy support system to mitigate mechanical vibrations from the cryocooler's pulsed tube, this innovative approach successfully demonstrates proof of concept. It offers unprecedented capabilities for state-of-the-art cryogenic microscopy and microanalysis in materials and biological sciences.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Two-dimensional coherent spectrum of high-spin models via a quantum computing approach

Here in this work we present and benchmark a quantum computing approach to calculate the two-dimensional coherent spectrum (2DCS) of high-spin models. Our approach is based on simulating their real-time dynamics in the presence of several magnetic field pulses, which are spaced in time. We utilize the adaptive variational quantum dynamics simulation algorithm for the study due to its compact circuits, which enables simulations over sufficiently long times to achieve the required resolution in frequency space. Specifically, we consider an antiferromagnetic quantum spin model that incorporates Dzyaloshinskii-Moriya interactions and single-ion anisotropy. The obtained 2DCS spectra exhibit distinct peaks at multiples of the magnon frequency, arising from transitions between different eigenstates of the unperturbed Hamiltonian. By comparing the one-dimensional coherent spectrum with 2DCS, we demonstrate that 2DCS provides a higher resolution of the energy spectrum. We further investigate how the quantum resources scale with the magnitude of the spin using two different binary encodings of the high-spin operators: the standard binary encoding and the Gray code. At low magnetic fields both encodings require comparable quantum resources, but at larger field strengths the Gray code is advantageous. Numerical simulations for spin models with increasing number of sites indicate a polynomial system-size scaling for quantum resources. Lastly, we compare the numerical 2DCS with experimental results on a rare-earth orthoferrite system. The observed strength of the magnonic high-harmonic generation signals in the 2DCS of the quantum high-spin model aligns well with the experimental data, showing significant improvement over the corresponding mean-field results.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optically heralded microwave photon addition

Photons with optical frequencies of a few hundred terahertz are perhaps the only way to distribute quantum information over long distances. Superconducting qubits, which are one of the most promising approaches for realizing large-scale quantum machines, operate on microwave photons at frequencies that are ~40,000 times lower. To network these quantum machines across appreciable distances, we must bridge this frequency gap. Here we implement and demonstrate a transducer that can generate correlated optical and microwave photons. In this study, we use it to show that by detecting an optical photon we generate an added microwave photon with an efficiency of ~35%. Our device uses a gigahertz nanomechanical resonance as an intermediary, which efficiently couples to optical and microwave channels through strong optomechanical and piezoelectric interactions. We show continuous operation of the transducer with 5% frequency conversion efficiency, input-referred added noise of ~100, and pulsed microwave photon generation at a heralding rate of 15 Hz. Optical absorption in the device generates thermal noise of less than two microwave photons. Improvements of the system efficiencies and device performance are necessary to realize a high rate of entanglement generation between distant microwave-frequency quantum nodes, but these enhancements are within reach.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Thermopile Energy Harvesting for Subsurface Wellbore Sensors (Final Report)

Robust in situ power harvesting underlies all efforts to enable downhole autonomous sensors for real-time and long-term monitoring of CO 2 plume movement and permeance, wellbore health, and induced seismicity. This project evaluated the potential use of downhole thermopile arrays, known as thermoelectric generators (TEGs), as power sources to charge sensors for in situ real-time, long-term data capture and transmission. Real-time downhole monitoring will enable “Big Data” techniques and machine learning, using massive amounts of continuous data from embedded sensors, to quantify short- and long-term stability and safety of enhanced oil recovery and/or commercial-scale geologic CO 2 storage. This project evaluated possible placement of the TEGs at two different wellbore locations: on the outside of the casing; or on the production tubing. TEGs convert heat flux to electrical power, and in the borehole environment, would convert heat flux into or out of the borehole into power for downhole sensors. Such heat flux would be driven by pumping of cold or hot fluids into the borehole—for instance, injecting supercritical CO 2 —creating a thermal pulse that could power the downhole sensors. Hence, wireless power generation could be accomplished with in situ TEG energy harvesting. This final report summarizes the project’s efforts that accomplished the creation of a fully operational thermopile field unit, including selection of materials, laboratory benchtop experiments and thermal-hydrologic modeling for design and optimization of the field-scale power generation test unit. Finally, the report describes the field unit that has been built and presents results of performance and survivability testing. The performance and survivability testing evaluated the following: 1) downhole power generation in response to a thermal gradient produced by pumping a heated fluid down a borehole and through the field unit; and 2) component survivability and operation at elevated temperature and pressure conditions representative of field conditions. The performance and survivability testing show that TEG arrays are viable for generating ample energy to power downhole sensors, although it is important to note that developing or connecting to sensors was beyond the scope of this project. This project’s accomplishments thus traversed from a low Technical Readiness Level (TRL) on fundamental concepts of the application and modeling to TRL-5 via testing of the fully integrated field unit for power generation in relevant environments. A fully issued United States Patent covers the wellbore power harvesting technology and applications developed by this project.

47 OTHER INSTRUMENTATION↗

Soft x-ray high-harmonic generation in an anti-resonant hollow core fiber driven by a 3 μ m ultrafast laser

High-harmonic upconversion driven by a mid-infrared femtosecond laser can generate coherent soft x-ray beams in a tabletop-scale setup. Here, we report on a compact ytterbium-pumped optical parametric chirped pulse amplifier (OPCPA) laser system seeded by an all-fiber front-end and employing periodically poled lithium niobate (PPLN) nonlinear media operated near the pulse fluence limits of current commercially available PPLN crystals. The OPCPA delivers 3 µm wavelength pulses with 775 µJ energy at 1 kHz repetition rate, with transform-limited 120 fs pulse duration, diffraction-limited beam quality, and ultrahigh 0.33% rms energy stability over >18 h. Using this laser, we generate soft x-ray high harmonics (HHG) in argon gas by focusing into a low-loss, high-pressure gas-filled anti-resonant hollow core fiber (ARHCF), generating coherent light at photon energies up to the argon L-edge (250 eV) and carbon K-edge (284 eV), with high beam quality and ∼1% rms energy stability. This work demonstrates soft x-ray HHG in a high-efficiency guided-wave phase matched geometry, overcoming the high losses inherent to mid-IR propagation in unstructured waveguides, or the short interaction lengths of gas cells or jets. The ARHCF can operate in the long term without damage and with the repetition rate, stability, and robustness required for demanding applications in spectromicroscopy and imaging. Finally, we discuss routes for further optimizing the soft x-ray HHG flux by driving He at higher laser intensities using either the signal (1.5 μm) or idler wavelengths (3 μm).

Femtosecond lasers↗

Real-Time Longitudinal Profile Measurement of Operational H⁻ Beam at the SNS Linac Using a Laser Comb

We demonstrate a novel technique to measure the longitudinal profile of an operational hydrogen ion (H⁻) beam in a non intrusive, real-time fashion. The measurement is conducted based on the photo-ionization of the ion beam with a phase modulated laser comb pico-second laser pulses with controllable temporal structure. The measurement technique has been applied to a 1-GeV, 1.4-MW H⁻ beam at the Spallation Neutron Source (SNS) high energy beam transport (HEBT). A stroboscopic photo-graph of H⁻ beamμbunch can be obtained by using a phase modulated laser comb. The entire measurement takes only 700 us.

Liu, Yun↗