Titanium alloy response sensitivity to variations in spectral reconstructions of National Ignition Facility xenon line-emission x-ray sources

Thermomechanical shock experiments on the National Ignition Facility (NIF) aim to study high strain rate dynamic material response. In such experiments, the NIF laser is used to generate high fluence x-ray emission sources, which irradiate material samples of interest. Under sufficiently high x-ray energy deposition, thermomechanical impulses are generated in the materials. While it is known that the characteristics of x-ray generated impulses vary as a function of incident x-ray spectra, it remains unclear how spectral assumptions and uncertainties in NIF spectral reconstructions affect our interpretation of impulsive loading. Here, in this paper, we simulate the response of a standard titanium alloy baseline sample to synthetic analytically derived and measured NIF xenon line-emission x-ray sources with a radiation hydrodynamics code. We vary the source spectral characteristics based on different source reconstruction techniques to understand the resulting variation in baseline sample response and compare the simulated response with experimental results. We find that the response is highly sensitive to assumptions made about the spectral contents and that knowledge of spectral uncertainties bounds our understanding of the resulting material response. The results of this effort help to extend our ability to use baseline material samples to extract quantitative properties from x-ray experiments on the NIF.

Alloys↗

Optimal hybrid power plants for electric vehicle charging demand

Transmission constraints, increasing motivations to decarbonize, and concerns over peak electric vehicle (EV) load impacts on local grids have driven electric customers to consider behind-the-meter, hybrid power plant generation and storage at the distributed-grid level for EV charging. In this study, we develop capabilities to optimize hybrid power plant component capacities for EV charging. We then demonstrate these capabilities in a case study for Boulder, Colorado, using public EV charging data as well as wind and solar resource data. Our results show system designs that balance the cost of energy with load-meeting and peak shaving performance. Within the case study, systems designed for wind, solar photovoltaic (PV), and storage resulted in lower cost of energy than those optimized for PV and storage only. This indicates that in areas where wind resource exists, hybrid power plants that include wind, PV, and battery assets can better meet EV charging loads (including peak loads that are prone to overloading local grids) than PV and battery assets alone. Future work to address limitations in this paper include extending cost modeling to include performance losses (e.g., based on operations or weather) and charging station costs to estimate levelized cost of charging, and quantifying uncertainty and error in our aggregation methods for estimating EV charging loads at the hourly timescale.

14 SOLAR ENERGY↗

Using probabilistic solar power forecasts to inform flexible ramp product procurement for the California ISO

How can independent system operators (ISOs) take advantage of probabilistic solar forecasts to lower generation costs and improve reliability of power systems? We discuss one three-step approach for doing so, focusing on how such forecasts might help the California Independent System Operator (CAISO) prepare unexpected net load ramps, where net load equals gross demand minus wind and solar production. First, we enhance an existing solar forecasting system to provide well-calibrated hours-ahead probabilistic forecasts. We then relate the degree of uncertainty reflected in the forecasted prediction intervals (independent variables) to error distributions for net load ramp forecasts for the CAISO real-time market (dependent variable) using machine learning and quantile regression. Projected ramp forecast errors conditioned on solar uncertainty are translated into flexible ramp requirements that therefore reflect real-time meteorological and solar conditions, improving on typical ISO procedures. Detailed descriptions are provided on the quantile regression and kth-nearest neighbor categorization methods for accomplishing that translation. Finally, a multiple time-scale look-ahead market simulation model is applied to a 118-bus IEEE Reliability Test System, modified to represent the CAISO generation mix and demand distributions. The model runs quantify how solar-conditioned ramp requirements can, first, decrease operating costs by reducing requirements compared to often conservative unconditional methods and, second, decrease generation scarcity events and consequently improve reliability by increasing flexibility requirements at times when unconditional forecast-based requirements understate actual ramp uncertainty. Solar-conditioned ramp requirements are found to reduce generation operating costs by about 2% for the test system (which would be equivalent to over $\$100$ million per year for a CAISO-size system).

14 SOLAR ENERGY↗

A Data-Driven Nonparametric Approach for Probabilistic Load-Margin Assessment Considering Wind Power Penetration

A modern power system is characterized by an increasing penetration of wind power, which results in large uncertainties in its states. These uncertainties must be quantified properly; otherwise, the system security may be threatened. Facing this challenge, here we propose a cost-effective, data-driven approach to assessing a power system's load margin probabilistically. Using actual wind data, a kernel density estimator is applied to infer the nonparametric wind speed distributions, which are further merged into the framework of a vine copula. The latter enables us to simulate complex multivariate and highly dependent model inputs with a variety of bivariate copulae that precisely represent the tail dependence in the correlated samples. Furthermore, to reduce the prohibitive computational time of traditional Monte-Carlo simulations that process a large amount of samples, we propose to use a nonparametric, Gaussian-process-emulator-based reduced-order model to replace the original complicated continuation power-flow model through a Bayesian-learning framework. To accelerate the convergence rate of this Bayesian algorithm, a truncated polynomial chaos surrogate, which serves as a highly efficient, parametric Bayesian prior, is developed. This emulator allows us to execute the time-consuming continuation power-flow solver at the sampled values with a negligible computational cost. Results of simulations that are performed on several test systems reveal the impressive performance of the proposed method in the probabilistic load-margin assessment.

17 WIND ENERGY↗

Impacts of constraints and uncertainties on projected amount of Hanford low-activity waste glasses

A systematic evaluation of Hanford low-activity waste (LAW) loading in alkali-aluminoborosilicate glasses was performed. A set of 22 waste compositions were selected to represent the range of wastes anticipated across the Hanford mission. Glass composition was formulated for each waste to simultaneously satisfy a full cadre of property and composition constraints while maximizing waste loading. Glass properties were estimated using property models recently developed for Hanford LAW Facility operation. The impacts from the property and composition constraints on the glass mass to be produced were calculated and compared. Electrical conductivity, Vapor Hydration Test and SO 3 melter tolerance, and canister-centerline cooling crystal constraints have a large effect on reducing total glass mass, while the impact from Product Consistency Test, viscosity, and isothermal crystal constraints is relatively small. Additionally, effects of model prediction and process/composition uncertainties were quantified. The results identified areas of future research that could be useful to improve the efficiency of plant operation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Stability and control of power systems with high penetrations of inverter-based resources: An accessible review of current knowledge and open questions

As power system renewable energy penetrations increase, the ways in which key renewable technologies such as wind and solar photovoltaics (PV) differ from thermal generators become more apparent. Many studies have examined the variability and uncertainty of such generators and described how generation and load can be balanced for a wide variety of annual energy penetrations, at timescales from seconds to years. Another important characteristic of these resources is asynchronicity, the result of using inverters to interface the prime energy source with the power system as opposed to synchronous generators. Unlike synchronous generators, whose frequency of alternating current (AC) injection is physically coupled to the rotation of the machine itself, inverter based asynchronous generators do not share the same physical coupling with the generated frequency. These subtle differences impact the operations of power systems developed around the characteristics of synchronous generators. In this paper we review current knowledge and open research questions concerning the interplay between asynchronous inverter-based resources (IBRs) and cycle- to second-scale power system dynamics, with a focus on how stability and control may be impacted or need to be achieved differently when there are high instantaneous penetrations of IBRs across an interconnection. This work does not seek to provide a comprehensive review of the latest developments, but is instead intended to be accessible to any reader with an engineering background and an interest in power systems and renewable energy. As such, the paper includes basic material on power electronics, control schemes for IBRs, and power system stability; and uses this background material to describe potential impacts of IBRs on power system stability, operational challenges associated with large amounts of distributed IBR generation, and modern power system simulation trends driven by IBR characteristics.

14 SOLAR ENERGY↗

A review on the integration of probabilistic solar forecasting in power systems

As one of the fastest growing renewable energy sources, the integration of solar power poses great challenges to power systems due to its variable and uncertain nature. As an effective approach to promote the integration of solar power in power systems, the value of probabilistic forecasts is being increasingly recognized in the recent decade. While the current use of probabilistic forecasts in power systems is limited, enormous amount of research has been conducted to promote the adoption of probabilistic forecasts and many methods have been proposed. This paper gives a comprehensive review on how probabilistic solar forecasts are utilized in power systems to address the challenges. Potential methods to deal with uncertainties in power systems are summarized, such as probabilistic load flow models, stochastic optimization, robust optimization, and chance constraints. Additionally, specific areas where these methods can be applied are discussed and state-of-the-art studies are summarized.

14 SOLAR ENERGY↗

Viscosity Measurements in Extreme Conditions

Radiation-hydrodynamics simulations are critical to the NNSA complex for understanding high energy density physics and for addressing problems in national security science. However, current rad-hydro codes typically do not account for viscosity, which generally leads to large uncertainties in problems involving mixing of materials under shock loading. This report details progress made towards experimental measurements of fluid viscosity at high pressures and temperatures achieved by shock wave compression techniques, as well as complementary material model development and hydrodynamic simulations.

36 MATERIALS SCIENCE↗

A Hybrid Reinforcement Learning-MPC Approach for Distribution System Critical Load Restoration

This paper proposes a hybrid control approach for distribution system critical load restoration, combining deep reinforcement learning (RL) and model predictive control (MPC) aiming at maximizing total restored load following an extreme event. RL determines a policy for quantifying operating reserve requirements, thereby hedging against uncertainty, while MPC models grid operations incorporating RL policy actions (i.e., reserve requirements), renewable (wind and solar) power predictions, and load demand forecasts. We formulate the reserve requirement determination problem as a sequential decision-making problem based on the Markov Decision Process (MDP) and design an RL learning environment based on the OpenAI Gym framework and MPC simulation. The RL agent reward and MPC objective function aim to maximize and monotonically increase total restored load and minimize load shedding and renewable power curtailment. The RL algorithm is trained offline using a historical forecast of renewable generation and load demand. The method is tested using a modified IEEE 13-bus distribution test feeder containing wind turbine, photovoltaic, microturbine, and battery. Case studies demonstrated that the proposed method outperforms other policies with static operating reserves.

distribution system↗

Peak Reduction in a Residential Community Through Bayesian Optimization of Transactive Control Signals

Daily residential power consumption in aggregate tends to have a large peak that places stress on the distribution system and induces high operational costs. This work shows that coordinated transactive control of noncritical loads within a residential community or microgrid can help to alleviate peak-time stress on the distribution system by flattening the aggregate load curve. Treating the load forecaster as a high-fidelity, expensive black-box function, a new algorithm utilizing Bayesian optimization (BO) is proposed to achieve the best solution under uncertainty with minimal computing effort. The proposed BO algorithm manipulates the shape of the load based on transactive signals sent to each home. The thermostatically controlled loads (TCLs) act out of self-interest in response to the given price while maintaining comfort, and the optimizer exploits the thermal energy retention of the homes for the benefit of the community. Simulations confirm consistent neighborhood-level peak power reduction and energy cost savings.

Schomer, Ian↗

Cesium Batch Contact Equilibrium Testing of Crystalline Silicotitanate (CST) Sieve Cuts in SRS Average Simulant and Examination of CST Samples Aged in Caustic and Simulant in Support of Tank Closure Cesium Removal 1A (TCCR-1A)

Batch contact testing to determine cesium equilibrium loading on Crystalline Silicotitanate ion exchange media in Savannah River Site Average Waste Simulant at 25 °C indicated that smaller diameter particles isolated by sieving pretreated CST media may load slightly higher (<10%) amounts of cesium, though the differences are within analytical uncertainty. In addition, ion exchange media sub-samples stored in 2-4 M NaOH and caustic simulant solutions for ~2.5 years were examined by optical microscopy and the 3 M NaOH sample was also analyzed to determine whether changes in the particle size distribution occurred during storage. No visual indications of particle attrition or agglomeration were observed for any sample. Particle size analysis indicated that a slight decrease occurred in the average particle diameter following contact with 3 M NaOH (541 µm average diameter versus 566 µm for the pretreated CST prior to contact). A small increase (from 0 to <0.5 wt. %) in the number of particles ranging from 271 and 322 µm was also observed for the CST sample contacted with 3 M NaOH relative to a sample of the original pretreated material. However, this small change could be due to sub-sampling differences or analytical uncertainty. It does not appear that small particles are formed to a significant degree during CST caustic contact or that small particles which do form (presumably from attrition of larger particles during pretreatment) load significantly more cesium than the bulk material. Minimal other negative consequences were observed associated with CST extended caustic or simulant contact, except for the tendency for more concentrated salt solutions to form some salt crystals which deposit on the media over time.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Hybrid Reinforcement Learning-MPC Approach for Distribution System Critical Load Restoration: Preprint

This paper proposes a hybrid control approach for distribution system critical load restoration, combining deep reinforcement learning (RL) and model predictive control (MPC) aiming at maximizing total restored load following an extreme event. RL determines a policy for quantifying operating reserve requirements, thereby hedging against uncertainty, while MPC models grid operations incorporating RL policy actions, i.e., the reserve requirement, renewable (wind and solar) power predictions, and load demand forecasts. We formulate the reserve requirement determination problem as a sequential decision making problem based on the Markov Decision Process (MDP) and design an RL learning environment based on the OpenAI Gym framework and MPC. The RL agent reward and MPC objective function aim to maximize and monotonically increase total restored load and minimize load shedding and renewable power curtailment. The RL algorithm is trained off-line using historical forecast of renewable generation and load demand. The method is tested using a modified IEEE 13-bus distribution test feeder containing wind turbine, photovoltaic, microturbine and battery. Case studies demonstrated that the proposed method outperforms other operating reserve determination methods.

distribution system↗

Time-of-Use and Demand Charge Battery Controller Using Stochastic Model Predictive Control

Stationary batteries in residential and commercial buildings are often used to smooth customer load profiles and to lower customer electricity bills. Controllers for these battery systems should account for customer energy consumption, rate structures, and high internal battery temperatures, which can lead to reduced performance over the battery lifetime. It is important to consider the uncertainty in forecasting energy consumption and temperature, especially for customers with highly variable and uncertain loads. We propose a novel battery controller using stochastic model predictive control that accounts for these uncertainties and can handle complex rate structures, including demand charges. We show that the controller performs better than standard model predictive control when there is significant uncertainty in the forecast. We also show improvements in the performance with more accurate forecasts and with a more aggressive control strategy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Time-of-Use and Demand Charge Battery Controller Using Stochastic Model Predictive Control: Preprint

Stationary batteries in residential and commercial buildings are often used to smooth customer load profiles and to lower customer electricity bills. Controllers for these battery systems should account for customer energy consumption, rate structures, and high internal battery temperatures, which can lead to reduced performance over the battery lifetime. It is important to consider the uncertainty in forecasting energy consumption and temperature, especially for customers with highly variable and uncertain loads. We propose a novel battery controller using stochastic model predictive control that accounts for these uncertainties and can handle complex rate structures, including demand charges. We show that the controller performs better than standard model predictive control when there is significant uncertainty in the forecast. We also show improvements in the performance with more accurate forecasts and with a more aggressive control strategy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Battery Control Using Stochastic Model Predictive Control

Stationary batteries in residential and commercial buildings are often used to smooth customer load profiles and to lower customer electricity bills. Controllers for these battery systems should account for customer energy consumption, rate structures, and high internal battery temperatures, which can lead to reduced performance over the battery lifetime. It is important to consider the uncertainty in forecasting energy consumption and temperature, especially for customers with highly variable and uncertain loads. We propose a novel battery controller using stochastic model predictive control that accounts for these uncertainties and can handle complex rate structures, including demand charges. We show that the controller performs better than standard model predictive control when there is significant uncertainty in the forecast. We also show improvements in the performance with more accurate forecasts and with a more aggressive control strategy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Restoring Distribution System Under Renewable Uncertainty Using Reinforcement Learning

Distributed energy resources (DERs) in distribution systems, including renewable generation, micro-turbine, and energy storage, can be used to restore critical loads following extreme events to increase grid resiliency. However, properly coordinating multiple DERs in the system for multi-step restoration process under renewable uncertainty and fuel availability is a complicated sequential optimal control problem. Due to its capability to handle system non-linearity and uncertainty, reinforcement learning (RL) stands out as a potentially powerful candidate in solving complex sequential control problems. Moreover, the offline training of RL provides excellent action readiness during online operation, making it suitable to problems such as load restoration, where in-time, correct and coordinated actions are needed. In this study, a distribution system prioritized load restoration based on a simplified single-bus system is studied: with imperfect renewable generation forecast, the performance of an RL controller is compared with that of a deterministic model predictive control (MPC). Our experiment results show that the RL controller is able to learn from experience, adapt to the imperfect forecast information and provide a more reliable restoration process when compared with the baseline controller.

61 RADIATION PROTECTION AND DOSIMETRY↗

Restoring Distribution System Under Renewable Uncertainty Using Reinforcement Learning

Distributed energy resources (DER) in distribution systems, including renewable generation, micro-turbine, and energy storage, can be used to restore critical loads following extreme events to increase grid resiliency. However, properly coordinating multiple DERs in the system for multi-step restoration process under renewable uncertainty and fuel availability is a complicated sequential optimal control problem. Due to its capability to handle system non-linearity and uncertainty, reinforcement learning (RL) stands out as a potentially powerful candidate in solving complex sequential control problems. Moreover, the offline training of RL provides excellent action readiness during online operation, making it suitable to problems such as load restoration, where in-time, correct and coordinated actions are needed. In this study, a distribution system prioritized load restoration based on a simplified single-bus system is studied: with imperfect renewable generation forecast, the performance of an RL controller is compared with that of a deterministic model predictive control (MPC). Our experiment results show that the RL controller is able to learn from experience, adapt to the imperfect forecast information and provide a more reliable restoration process when compared with the baseline MPC controller.

61 RADIATION PROTECTION AND DOSIMETRY↗

Storing Affordability: Battery Storage as an Asset to Reduce Data Center Cost Shifts

This report examines how battery energy storage systems (BESS) can help utilities accommodate large load growth while protecting affordability for existing ratepayers. Rapid growth in electricity demand from artificial intelligence (AI) data centers is straining the U.S. grid. Furthermore, many new data centers are entering rural markets, which could offer economic benefits but may also pose implementation challenges for smaller utilities. At the same time, retail electricity prices are increasing faster than inflation, elevating customer affordability as a key challenge. While data centers have not been the primary driver of increases in residential prices to date, they have pushed wholesale energy and capacity prices higher in several markets. Fundamental utility cost-allocation principles show that data center growth can be rate-positive for existing customers only if new peak demand grows faster than the costs a utility must incur to serve it. Several factors, including a utility’s degree of wholesale market exposure, forecast uncertainty and stranded-asset risk, and tariff design can determine the outcome of load growth on retail rates. Energy storage can make several affordability contributions in the face of this landscape of uncertainty and market volatility, including deferral of higher-cost grid investments through improved utilization of existing assets and flexibility of new large loads, insulation from volatile wholesale prices through peak shaving, and reliability support to address grid risks stemming from the behavior of AI data center loads. Different potential BESS deployment pathways—utility-scale front-of-the-meter systems, aggregated small-scale storage installations, and data center-sited behind-the-meter storage—are compared against each other and against conventional capacity alternatives. This framework is intended as a conceptual resource to utilities, particularly smaller public utilities with rural service territories, who may be considering the role that energy storage can play in insulating existing ratepayers from data center cost shifts.

25 ENERGY STORAGE↗