Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “light detection and ranging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Extreme Molecular Complexity Resulting in a Continuum of Carbonaceous Species in Biomass Burning Tar Balls from Wildfire Smoke

Biomass burning emits a wide range of carbonaceous particles into the atmosphere and has negative impacts on human health and the Earth’s radiative balance. Nonvolatile spherical organic aerosol particles, commonly known as tar balls, represent one of the most abundant particles in aged biomass burning smoke. However, the detailed molecular-level composition of ambient tar balls is largely unknown but critical to access their environmental impacts. Ambient aerosol samples collected during a wildfire event, which were ~90% tar balls by number fraction, were analyzed using ultrahigh resolution Orbitrap Elite mass spectrometry with four complementary ionization modes. Our results show the molecular composition of tar balls to be complex, composed of over 10,000 molecular formulas. Model estimated saturation mass concentrations and relative humidity dependent glass transition temperatures were consistent with low volatility and solid morphology as expected for tar balls. Room-temperature evaporation kinetics showed that these particles were composed of ~90% non-volatile species. The molecular complexity detected here signifies a continuum of carbonaceous species, ranging from C3 to C45 with continuous ranges of oxygenation and hydrogen saturation for each Cn. Approximately 24% of molecular formulas were estimated the be highly aromatic, which could indicate chemical compounds with negative health effects, and which may contribute to visible light absorption. The carbon continuum observed here has significant implications for the molecular characterization of atmospheric organic matter. The level of complexity detected here should not be ignored in future studies and we demonstrate that multiple analytical methods may be required to suitably interpret this complexity on a molecular level.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Observation of thermally activated coherent magnon-magnon coupling in a magnonic hybrid system

In this work, we experimentally demonstrate coherent magnon-magnon coupling by thermal spin excitations in yttrium iron garnet/permalloy (YIG/Py) hybrid structures using microfocused Brillouin light scattering—an optical technique that enables the detection of zero-wave-vector and higher-order wave-vector spin waves in a broad frequency range. The thermally activated magnons in the bilayer lead to a hybrid excitation between magnon modes in the conductive Py layer with a wide wave-vector range and the first perpendicular standing magnon modes in the insulating YIG layer, facilitated by strong interfacial exchange coupling. To further investigate this coupling, we compare the thermal magnon spectra with the results obtained from electrical excitation and detection methods, which primarily detect the uniform Py mode. The realization of coherent coupling between incoherent (thermal) magnons is important for advancing energy-efficient magnonic devices, particularly in classical as well as quantum spin-wave computing technologies.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Search for monopole-dipole interactions with atom interferometry

Light, weakly coupled bosonic particles such as axions can mediate long range monopole-dipole interactions between matter and spins. We propose a new experimental method to detect such a force exerted by the spin of electrons on a freely falling atom using atom interferometry. The intrinsic advantages of atom interferometry, such as the freely falling nature of the atom and the well-defined response of the atom to external magnetic fields, should enable the proposed method to overcome systematic effects induced by vibrations, magnetic fields, and gravity. This approach is most suited to probe forces with a range ≳ 10 cm. With current technology, our proposed setup could potentially extend probes of such forces by an order of magnitude beyond present laboratory limits.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A low noise CMOS camera system for 2D resonant inelastic soft X-ray scattering

Resonant Inelastic X-ray Scattering (RIXS) is a powerful spectroscopic technique to study quantum properties of materials in the bulk. A novel variant of RIXS, called 2D RIXS, enables concurrent measurement of the scattered X-ray spectrum for a wide range of input energies, improving on the typically low throughput of 1D RIXS. In the soft X-ray domain, 2D RIXS demands an X-ray camera system with small pixels, large area, high quantum efficiency and low noise to limit the false detection rate in long duration exposures. We designed and implemented a 7.5 Megapixel back-illuminated CMOS detector with 5 μm pixels and high quantum efficiency in the 200–1,000 eV X-ray energy range for the QERLIN 2D RIXS spectrometer at the Advanced Light Source. The QERLIN beamline and detector are currently in commissioning. The camera noise from in-situ 3 s long dark exposures is 7e - or less and the leakage current is 6.5 × 10 -3 e - /(pixel ∙ s). For individual 500 eV X-rays, the expected efficiency is greater than 75% and the false detection rate is ~1 × 10 -5 per pixel.

47 OTHER INSTRUMENTATION↗

Searching for high-frequency gravitational waves with phonons

The gravitational wave (GW) spectrum at frequencies above a kHz is a largely unexplored frontier. We show that detectors with sensitivity to single-phonon excitations in crystal targets can search for GWs with frequencies, 1 THz ≲ f ≲ 100 THz , corresponding to the range of optical phonon energies, 1 meV ≲ ω ≲ 100 meV . Such detectors are already being built to search for light dark matter (DM), and therefore sensitivity to high-frequency GWs will be achieved as a byproduct. We begin by deriving the absorption rate of a general GW signal into single phonons. We then focus on carefully defining the detector sensitivity to monochromatic and chirp signals, and compute the detector sensitivity for many proposed light DM detection targets. The detector sensitivity is then compared to the signal strength of candidate high-frequency GW sources, e.g., superradiant annihilation and black hole inspiral, as well as other recent detector proposals in the 1 MHz ≲ f ≲ 100 THz frequency range. With a judicious choice of target materials, a collection of detectors could optimistically achieve sensitivities to monochromatic signals with h 0 ∼ 10 − 23 − 10 − 25 over 1 THz ≲ f ≲ 100 THz . Published by the American Physical Society 2024

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Near-field probing of strong light-matter coupling in single IR antennae

Quantum well intersubband polaritons are traditionally studied in large scale ensembles, over many wavelengths in size.In this presentation, we demonstrate that it is possible to detect and investigate intersubband polaritons in a single sub-wavelength nanoantenna in the IR frequency range. We observe polariton formation using a scattering-type near-fieldmicroscope and nano-FTIR spectroscopy. In this work, we will discuss near-field spectroscopic signatures of plasmonic antennae withand without coupling to the intersubband transition in quantum wells located underneath the antenna. Evanescent fieldamplitude spectra recorded on the antenna surface show a mode anti-crossing behavior in the strong coupling case. Wealso observe a corresponding strong-coupling signature in the phase of the detected field. We anticipate that this near-fieldapproach will enable explorations of strong and ultrastrong light-matter coupling in the single nanoantenna regime,including investigations of the elusive effect of ISB polariton condensation.

36 MATERIALS SCIENCE↗

First Resolved Scattered-light Images of Four Debris Disks in Scorpius-Centaurus with the Gemini Planet Imager

In this work, we present the first spatially resolved scattered-light images of four debris disks around members of the Scorpius-Centaurus (Sco-Cen) OB association with high-contrast imaging and polarimetry using the Gemini Planet Imager (GPI). All four disks are resolved for the first time in polarized light, and one disk is also detected in total intensity. The three disks imaged around HD 111161, HD 143675, and HD 145560 are symmetric in both morphology and brightness distribution. The three systems span a range of inclinations and radial extents. The disk imaged around HD 98363 shows indications of asymmetries in morphology and brightness distribution, with some structural similarities to the HD 106906 planet–disk system. Uniquely, HD 98363 has a wide comoving stellar companion, Wray 15-788, with a recently resolved disk with very different morphological properties. HD 98363 A/B is the first binary debris disk system with two spatially resolved disks. All four targets have been observed with ALMA, and their continuum fluxes range from one nondetection to one of the brightest disks in the region. With the new results, a total of 15 A/F stars in Sco-Cen have resolved scattered-light debris disks, and approximately half of these systems exhibit some form of asymmetry. Combining the GPI disk structure results with information from the literature on millimeter fluxes and imaged planets reveals a diversity of disk properties in this young population. Overall, the four newly resolved disks contribute to the census of disk structures measured around A/F stars at this important stage in the development of planetary systems.

79 ASTRONOMY AND ASTROPHYSICS↗

meso -Ethynyl-extended push–pull type porphyrins for near-infrared organic photodetectors

We report natural porphyrins play a key role in a range of vital functions such as oxygen transport in the bloodstream and the conversion of light to chemical energy in plants. Likewise, synthetic porphyrin derivatives can be used to detect light and convert it into an electrical current in photodiodes. The versatility of porphyrinoid chemistry allows to extend the absorptivity (and hence detectivity) to the near-infrared while maintaining good solubility, suitable electrochemical properties, and compatibility with the electron acceptor molecules required to achieve a reasonable photocurrent. Here, our efforts on the design and synthesis of novel push–pull type meso-ethynyl-extended porphyrin compounds, both of A–D–A and D–A–D type (D = donor, A = acceptor), and their evaluation in prototype near-infrared organic photodetector devices are presented. The push–pull design with strongly electron-deficient building blocks results in absorption onsets up to 1200 nm, translating in an optical gap approaching 1 eV. Both A–D–A and D–A–D small molecules show good photodetector performance, with a peak specific detectivity near 2 x 10 11 and 4 x 10 11 Jones at 1000 nm (at -2 V bias), respectively. These values are among the best reported so far for small molecule based near-infrared organic photodetectors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A miniaturized long-life acoustic transmitter for animal tracking in marine environments

Marine and hydrokinetic (MHK) energy devices are early-stage technologies and their impacts to ocean life and environment are largely unknown, which consequently limits the progress of deploying these devices at commercial scale. Optical and acoustic imaging have been the primary technologies for monitoring marine animals’ behavior at existing or potential MHK sites. However, these technologies lack the ability to identify individual animals, which makes them less useful in identifying protected species as well as studying the animals’ long-term behavior. Implantable acoustic transmitters with unique identification codes could be used as a complementary technology. To minimize the tag burden on the tagged animal (and hence the resulting bias) and to satisfy the long-term monitoring needs, it is desired that the implanted transmitter be as small and light as possible and can last for as long as possible. To date, the smallest acoustic transmitters suitable for marine animal tracking have relatively short service life and detection range (up to 200 m). In this report, we introduce a new miniaturized acoustic transmitter which operates at 208.3 kHz. It offers a smaller dry weight (0.45 g), a significantly longer service life (140 days at a 5-second ping rate) as well as a greater detection range than the existing commercial counterparts, which will help obtain more comprehensive movement and behavioral information of animals around MHK energy devices.

Li, Huidong↗

Development of a novel, windowless, amorphous selenium based photodetector for use in liquid noble detectors

Detection of the vacuum ultraviolet (VUV) scintillation light produced by liquid noble elements is a central challenge in order to fully exploit the available timing, topological, and calorimetric information in detectors leveraging these media. Here in this paper, we characterize a novel, windowless amorphous selenium based photodetector with direct sensitivity to VUV light. We present here the manufacturing and experimental setup used to operate this detector at low transport electric fields (2.7–5.2 V/μm) and across a wide range of temperatures (77 K–290 K). This work shows that the first proof-of-principle windowless amorphous selenium device is robust under cryogenic conditions, responsive to VUV light at cryogenic temperatures, and preserves argon purity. These findings motivate a continued exploration of amorphous selenium devices for simultaneous detection of scintillation light and ionization charge in noble element detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparative scintillation performance of EJ-309, EJ-276, and a novel organic glass

An organic glass scintillator developed by Sandia National Laboratories was characterized in terms of its light output and pulse shape discrimination (PSD) properties and compared to commercial liquid (EJ-309) and plastic (EJ-276) organic scintillators. The electron light output was determined through relative comparison of the 137 Cs Compton edge location. The proton light yield was measured using a double time-of-flight technique at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. Using a tunable broad-spectrum neutron source and an array of pulse-shape-discriminating observation scintillators, a continuous measurement of the proton light yield was performed for EJ-309 (200 keV–3.2 MeV), EJ-276 (170 keV–4.9 MeV), and the organic glass (50 keV–20 MeV) . Finally, the PSD properties of the organic glass, EJ-309, and EJ-276 were evaluated using an AmBe source and compared via a figure-of-merit metric. The organic glass exhibited a higher electron light output than both EJ-309 and EJ-276. Its proton light yield and PSD performance were comparable to EJ-309 and superior to that of EJ-276. Finally, with these performance characteristics, the organic glass scintillator is well poised to replace current state-of-the-art PSD-capable scintillators in a range of fast neutron detection applications.

47 OTHER INSTRUMENTATION↗

Standoff Detection of Chemical Plumes Using Swept-ECQCL Remote Detection Technology: Results from EMRTC Complex Terrain Dual Tracer Experiment

As part of the Complex Terrain Dual Tracer Experiments performed in support of the LYNM program, a swept-wavelength external cavity quantum cascade laser (swept-ECQCL) remote detection system was deployed to measure chemical plume propagation with high temporal resolution. The swept-ECQCL remote detection technology was initially developed at PNNL, and is now under further development at Opticslah, LLC under SBIR funding from DOE (DOE SBIR Phase I Project DE-SC0019855, Remote Detection Technologies, Program Manager Chris Ramos). The swept-ECQCL technology provides a single-frequency infrared laser source which is rapidly scanned over a large wavelength range to measure the infrared absorption of gases, liquids, or solids. Analysis of the measured infrared absorption spectrum is used to detect, identify, and quantify the chemical species which are present. While most previous laser-based techniques used small wavelength tuning ranges to measure only a few isolated spectral lines of a few species, the swept-ECQCL provides the large tuning range needed to measure multiple species simultaneously, and to detect broad absorption features from large molecules or condensed phase materials. In addition, the swept-ECQCL systems have high enough spectral resolution and sensitivity to measure narrow lines of small molecules and determine isotope ratios. The remote detection system for gas plumes is based on the swept-ECQCL technology, and consists of a swept-ECQCL source, infrared detector, control electronics, and beam transmitting and alignment optics. The remote detection system directs the infrared output of the swept-ECQCL to a target retro reflector typically located at ~10-10,000 m distance. The swept-ECQCL wavelength is varied continuously over a large wavelength range (>1000 nm) at rates up to 1000 Hz. The swept ECQCL light reflected from the remote target is collected and focused onto an infrared photodetector. By measuring the detector signal continuously as the swept-ECQCL wavelength is varied, a time-series of absorption spectra are measured for the gases along the beam line of-sight. Based on analysis and fitting of the measured absorption spectra, the time-dependent chemical concentrations of species are determined. Multiple species and mixtures can be detected simultaneously, for all species with absorption features above the sensor noise floor. The sensor output is thus a continuous, high-speed record of identified chemicals along with their concentrations and isotope ratios of interest. The high-speed operation enables low-noise operation in conditions of atmospheric turbulence and allows tracking of fluctuating concentrations in transient chemical plumes as needed for reliable remote detection applications. All components operate with minimal cooling requirements and no cryogens are needed. In addition, the output infrared light is invisible with an intensity below the maximum permissible exposure (MPE) threshold of 100 mW/cm2 for these infrared wavelengths and thus eye safe. The measurement concept for plume detection using the swept-ECQCL remote detection system is as follows. The ECQCL beam is directed toward a remote retro-reflector, which reflects the beam back to the ECQCL system where it is focused onto an infrared photodetector. The line-of-sight from the ECQCL system to the retro-reflector defines the measurement path. The detected infrared signal is recorded continuously and detects the absorption of molecular species along the measurement path. Before a plume release, the system measures absorption from atmospheric constituents, which in this LWIR band consist primarily of lines from H 2 O and CO 2 , with additional weaker absorption from N 2 O, NH 3 , and O 3 possibly contributing. The system then measures any changes in absorption due to the tracer compounds when they enter the measurement path. The shape of absorption features is used to distinguish and identify the different tracer compounds, and the strength of the absorption is used to determine the path-integrated concentration – also called the column density.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of an optical sensor for measuring opacity changes in polyvinyl toluene scintillators

Polyvinyl toluene (PVT) based detectors are used in radiation portal monitors (RPMs) worldwide to detect the trafficking of illicit nuclear material. PVT scintillators, which are normally optically clear, have been observed to suffer internal fogging throughout their volume due to prolonged exposure to varying environmental conditions. These changes could lead to reduced performance for RPMs that utilize plastic scintillators. In this research, a proof of concept system, consisting of different color light emitting diodes (LEDs) and a single optical sensor (OS), were used to examine the change in light transmission through a PVT scintillator. This Optical Monitoring System (OMS), coupled with an environmentally exposed PVT detector, was tested in an environmental chamber where it was subjected to changes in temperature and humidity ranging from 55 °C at 100% relative humidity to –20 °C at 40% relative humidity. At temperatures below 10 °C, light transmission was reduced by 81% ± 8% for blue LEDs, 84% ± 5% for yellow LEDs, and 49% ± 4% for green LEDs. Similar reductions in detected light were not recorded when the OMS was tested with only air between the LEDs and OS. Therefore, the significant reductions in transmitted light were attributed to changes occurring within the PVT scintillator. These results indicate that a significant reduction in PVT opacity occurs due to wide environmental changes. A device such as the OMS could be used to track these changes and provide users an early indication that a portal monitor is suffering from reduced performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dark matter or regular matter in neutron stars? How to tell the difference from the coalescence of compact objects

The mirror twin Higgs model is a candidate for (strongly-interacting) complex dark matter, which mirrors SM interactions with heavier quark masses. A consequence of this model are mirror neutron stars—exotic stars made entirely of mirror matter, which are significantly smaller than neutron stars and electromagnetically dark. This makes mergers of two mirror neutron stars detectable and distinguishable in gravitational wave observations, but can we observationally distinguish between regular neutron stars and those that may contain some mirror matter? This is the question we study in this paper, focusing on two possible realizations of mirror matter coupled to standard model matter within a compact object: (i) mirror matter captured by a neutron star and (ii) mirror neutron star-neutron star coalescences. Regarding (i), here we find that (nonrotating) mirror-matter-admixed neutron stars no longer have a single mass-radius sequence, but rather exist in a two-dimensional mass-radius plane. Regarding (ii), we find that binary systems with mirror neutron stars would span a much wider range of chirp masses and completely different binary Love relations, allowing merger remnants to be very light black holes. The implications of this are that gravitational wave observations with advanced LIGO and Virgo, and x-ray observations with NICER, could detect or constrain the existence of mirror matter through searches with wider model and parameter priors.

79 ASTRONOMY AND ASTROPHYSICS↗

Broadband Photoconductive Sampling in Gallium Phosphide

Abstract Direct measurements of the electric field of light enable new observations of light–matter interactions. In the near‐infrared and visible spectral ranges, this typically relies on techniques that exploit nonlinearities in gases or solids, which limits their sensitivity. Here, a method for the detection of broadband near‐infrared fields spanning more than one octave from 110 to 220 THz based on linear absorption in a semiconductor is demonstrated. This technique, which avoids complex vacuum setups and works under ambient conditions, employs linear photoconductive sampling (LPS) in gallium phosphide. Simulations reveal that the response function of LPS is concerned with the intensity envelope of the gate field, in contrast to electro‐optic sampling, relaxing the stringent temporal requirements on the gate pulse.

36 MATERIALS SCIENCE↗

The Sensor Dilemma in Intelligent Transportation Systems

Intelligent Transportation Systems (ITS) are at the forefront in advancing the way we interact and perceive with the transportation network. This revolution is fueled by the significant advancement in sensor perception technologies such as Radar, LiDAR and Video Imaging which are the most popular modalities for ITS. Real-time perception data from these sensors allows intelligent infrastructure side decision making to improve the energy, efficiency and safety at traffic intersections. As traffic departments across the United States are transitioning from traditional loop detectors / emulators and embracing newer technologies, they are often left with a dilemma in choosing a sensor technology for infrastructure-based perception which is reliable, inexpensive, easy to setup and has robust performance in varying weather conditions. However, choosing a sensor which checks all boxes is not straightforward as every sensor type has unique benefits and drawbacks. Radar is excellent at detecting long range vehicles and weather resistance but lacks high resolution. LiDAR is expensive and weather-sensitive, while cameras provide rich visual data at a low cost but are constrained by lighting and visibility. This study examines Radar, LiDAR and camera sensors capabilities to ascertain whether any of these qualifies as the "best" sensor for ITS perception. Through this evaluation, we hope to draw attention to the necessity of National Renewable Energy Laboratory's (NREL) Infrastructure Perception and Control (IPC) framework which presents a multi-sensor track data fusion engine to assimilate multiple data streams in order to provide robust and reliable perception. While no single sensor can meet all the demands of ITS, a hybrid approach combining multiple sensor modalities like Radar, LiDAR and cameras, offers the most robust solution for enhancing the safety and efficiency in intelligent transportation systems.

33 ADVANCED PROPULSION SYSTEMS↗

Prognostics and Health Management in Nuclear Power Plants: An Updated Method-Centric Review With Special Focus on Data-Driven Methods

In a carbon-constrained world, future uses of nuclear power technologies can contribute to climate change mitigation as the installed electricity generating capacity and range of applications could be much greater and more diverse than with the current plants. To preserve the nuclear industry competitiveness in the global energy market, prognostics and health management (PHM) of plant assets is expected to be important for supporting and sustaining improvements in the economics associated with operating nuclear power plants (NPPs) while maintaining their high availability. Of interest are long-term operation of the legacy fleet to 80 years through subsequent license renewals and economic operation of new builds of either light water reactors or advanced reactor designs. Recent advances in data-driven analysis methods—largely represented by those in artificial intelligence and machine learning—have enhanced applications ranging from robust anomaly detection to automated control and autonomous operation of complex systems. The NPP equipment PHM is one area where the application of these algorithmic advances can significantly improve the ability to perform asset management. This paper provides an updated method-centric review of the full PHM suite in NPPs focusing on data-driven methods and advances since the last major survey article was published in 2015. The main approaches and the state of practice are described, including those for the tasks of data acquisition, condition monitoring, diagnostics, prognostics, and planning and decision-making. Research advances in non-nuclear power applications are also included to assess findings that may be applicable to the nuclear industry, along with the opportunities and challenges when adapting these developments to NPPs. Finally, this paper identifies key research needs in regard to data availability and quality, verification and validation, and uncertainty quantification.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Entanglement-enhanced optomechanical sensor array with application to dark matter searches

Abstract Squeezed light has long been used to enhance the precision of a single optomechanical sensor. An emerging set of proposals seeks to use arrays of optomechanical sensors to detect weak distributed forces, for applications ranging from gravity-based subterranean imaging to dark matter searches; however, a detailed investigation into the quantum-enhancement of this approach remains outstanding. Here, we propose an array of entanglement-enhanced optomechanical sensors to improve the broadband sensitivity of distributed force sensing. By coherently operating the optomechanical sensor array and distributing squeezing to entangle the optical fields, the array of sensors has a scaling advantage over independent sensors (i.e., $$\sqrt{M}\to M$$ M → M , where M is the number of sensors) due to coherence as well as joint noise suppression due to multi-partite entanglement. As an illustration, we consider entanglement-enhancement of an optomechanical accelerometer array to search for dark matter, and elucidate the challenge of realizing a quantum advantage in this context.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗