Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “level sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

BOREAS Level-3b Landsat TM Imagery: At-sensor Radiances in BSQ Format

For BOREAS, the level-3b Landsat TM data, along with the other remotely sensed images, were collected in order to provide spatially extensive information over the primary study areas. This information includes radiant energy, detailed land cover, and biophysical parameter maps such as FPAR and LAI. Although very similar in content to the level-3a Landsat TM products, the level-3b images were created to provide users with a directly usable at-sensor radiance image. Geographically, the level-3b images cover the BOREAS NSA and SSA. Temporally, the images cover the period of 22-Jun-1984 to 09-Jul-1996. The images are available in binary, image format files.

Hall, Forrest G.↗

Low volume packaging for a microinstrumentation system

A folding, multi-platform assembly has been developed for the packaging of a multi-chip microinstrumentation system. The assembly includes three solid platforms connected by flexible micromachined ribbon cables and it can be populated by sensors and electronics from a variety of technologies including surface mount and integrated circuit (IC) processes. The entire structure is fabricated from a four-inch silicon wafer using a simple four mask process and a post-process EDP etch. The micromachined ribbon cables allow the platform assembly to be folded into a three level structure with control electronics on the bottom level, microsensors and interface electronics on the second level, and sensors that need environmental access on the top level. Using the silicon multi-platform assembly, a prototype microinstrumentation system has been developed that includes a microcontroller unit and sensors for measuring temperature, barometric pressure, humidity, altitude, and acceleration as well as a telemetry device for wireless communication. When folded in the three level structure, this microsystem occupies only 5 cc and can be placed in an outer case the size of a wristwatch.

Mason, A.↗

Measurements of upper atmosphere water vapor made in situ with a new moisture sensor

A new thin-film aluminum oxide sensor, Aquamax II, has been developed for the measurement of stratospheric and upper tropospheric water vapor levels. The sensor is briefly described with attention given to its calibration and performance. Data obtained from six balloon flights are presented; almost all the results show a constant water vapor mixing ratio, in agreement with other data from midlatitude regions.

Chleck, D.↗

STS-114: Discovery Post MMT Press Conference

Bruce Buckingham from NASA Public Affairs introduces the panel who consists of: Wayne Hale, Space Shuttle Program Deputy Manager; John Muratore, Manager, Space Shuttle Systems and Integration; and Mike Wetmore, Director of Shuttle Processing. Hale begins with a video presentation of the point sensor box (black box) and discusses the troubleshooting plans that are in place to fix the low level fuel sensor inside the External Tank of the Space Shuttle Discovery. Muratore talks about exploring conditions that may be causing the problem and Wetmore discusses completing scrub securing. Questions from the news media pertaining to solutions to the sensor problem, risks involved, and anomalies are addressed.

Source record↗

Specific failure identification algorithms for the F-8

Analytical redundancy is applied to the pitch axis of an aircraft to enhance sensor fault detection. Three different designs based on monitoring Kalman filter residuals or likelihood functions were developed. Sensor failures were simulated to evaluate the performance of the algorithms on a nonlinear simulation of an F-8C aircraft. Based on requirements for sensor fault detection and preliminary simulator performance it is concluded that these algorithms have the potential for reducing the level of sensor redundancy in a digital flight control system without compromising performance.

Hartmann, G. L.↗

Advanced detection, isolation and accommodation of sensor failures: Real-time evaluation

The objective of the Advanced Detection, Isolation, and Accommodation (ADIA) Program is to improve the overall demonstrated reliability of digital electronic control systems for turbine engines by using analytical redundacy to detect sensor failures. The results of a real time hybrid computer evaluation of the ADIA algorithm are presented. Minimum detectable levels of sensor failures for an F100 engine control system are determined. Also included are details about the microprocessor implementation of the algorithm as well as a description of the algorithm itself.

Merrill, Walter C.↗

Advanced detection, isolation, and accommodation of sensor failures - Real-time evaluation

The objective of the Advanced Detection, Isolation, and Accommodation (ADIA) program is to improve the overall demonstrated reliability of digital electronic control systems for turbine engines by using analytical redundancy to detect sensor failures. The results of a real-time hybrid computer evaluation of the ADIA algorithm are presented. Minimum detectable levels of sensor failures for an F100 engine control system are determined. Also included are details about the microprocessor implementation of the algorithm as well as a description of the algorithm itself.

Merrill, Walter C.↗

Ten Years of VIIRS On-Orbit Geolocation Calibration and Performance

The first innovative Visible Infrared Imaging Radiometer Suite (VIIRS) sensor aboard the Suomi National Polar-orbiting Partnership (SNPP) satellite has been in operation for 10 years since its launch on 28 October 2011. The second VIIRS sensor aboard the first Join Polar Satellite System (JPSS-1) satellite has been in operation for 4 years since its launch on 18 November 2017, which became NOAA-20. Well-geolocated and radiometrically calibrated Level-1 sensor data records (SDRs) from VIIRS are crucial to numerical weather prediction (NWP) and Level-2+ environmental data record (EDR) algorithms and products. The high quality of Level-2+ EDRs is a requirement for the continuity of NASA Earth science data records (ESDRs) and climate data records (CDRs), one of the two objectives of the SNPP mission and one of the three elements in the JPSS mission objective. The other objective of the SNPP mission is risk reduction for the follow-on JPSS missions. This paper summarizes the on-orbit geolocation calibration and validation (Cal/Val) activities for both VIIRS sensors onboard SNPP and NOAA-20 in the past 10 years. These activities include nominal geolocation Cal/Val activities, risk reduction activities, and improvements for the on-orbit VIIRS sensor operations. After these activities, sub-pixel geolocation accuracy is achieved. Nadir equivalent geolocation uncertainty is generally within 75 m (1-σ), or 20% imagery band pixels, in either the along-scan or along-track direction for both SNPP and NOAA-20 VIIRS sensors. The worst 16-day measured geolocation errors (radial, 3-σ) are 280 m and 267 m, respectively, in the latest SNPP and NOAA-20 VIIRS data collections, which are better than the required accuracy of 375 m (radial, 3-σ). The risk reduction activities also improved VIIRS builds for JPSS-3 and JPSS-4 satellites, and provide lessons learned for other VIIRS-like sensor builds.

VIIRS↗

Full-scale engine demonstration of an advanced sensor failure detection, isolation and accommodation algorithm: Preliminary results

The objective of the advanced detection, isolation, and accommodation (ADIA) program is to improve the overall demonstrated reliability of digital electronic control systems for turbine engines. For this purpose, algorithms were developed which detect, isolate, and accommodate sensor failures using analytical redundancy. Preliminary results of a full scale engine demonstration of the ADIA algorithm are presented. Minimum detectable levels of sensor failures for an F100 turbofan engine control system are determined and compared to those obtained during a previous evaluation of this algorithm using a real-time hybrid computer simulation of the engine.

Merrill, Walter C.↗

Full-scale engine demonstration of an advanced sensor failure detection isolation, and accommodation algorithm - Preliminary results

The objective of the advanced detection, isolation, and accommodation (ADIA) program is to improve the overall demonstrated reliability of digital electronic control systems for turbine engines. For this purpose, algorithms were developed which detect, isolate, and accommodate sensor failures using analytical redundancy. Preliminary results of a full scale engine demonstration of the ADIA algorithm are presented. Minimum detectable levels of sensor failures for an F100 turbofan engine control system are determined and compared to those obtained during a previous evaluation of this algorithm using a real-time hybrid computer simulation of the engine.

Merrill, Walter C.↗

A densely spaced array of sea level monitors for the detection of vertical crustal deformation in the Shumagin seismic gap, Alaska

A network of sea level gauges has been installed with about 40 km spacing in the Shumagin Islands in order to detect relative vertical motion, in particular, possible crustal motion precursory to an expected major earthquake. This required the development and deployment of a pressure sensor sea level gauge suitable for installation on remote and harsh coastlines. Data are collected in near-real-time via satellite, both in order to exploit fully any precursors that may be observed and to provide continuous information on the status of the instruments. Using Wiener filtering techniques, it has been determined conservatively that no relative vertical crustal motion greater than 0.1 m between stations has occurred during 1981-1985. This is consistent with independent geodetic leveling and trilateration data, though evidence exists for more rapid deformation during 1978-1980. The sea level data collected so far have an rms noise level of about 0.04 m after processing; this is limited in part by the pressure sensor and associated electronics. Improved prressure gauges with better long-term stability have recently been installed. A short-baseline tiltmeter operating in a tunnel has demonstrated that suitably designed and located land-based tiltmeters have a lower noise level, and hence better precursor detection characteristics than the sea level gauges, at monthly and shorter periods.

Beavan, John↗

A Threshold Helium Leakage Detection Switch with Ultra Low Power Operation

Detecting helium leakage is important in many applications, such as in dry cask nuclear waste storage systems. This work develops a helium detection system based on the relative permittivity (dielectric constant) difference between air and helium. This difference changes the status of an electrostatic microelectromechanical system (MEMS) switch. The switch is a capacitive-based device and requires a very negligible amount of power. Exciting the switch’s electrical resonance enhances the MEMS switch sensitivity to detect low helium concentration. This work simulates two different MEMS switch configurations: a cantilever-based MEMS modeled as a single-degree-freedom model and a clamped-clamped beam MEMS molded using the COMSOL Multiphysics finite-element software. While both configurations demonstrate the switch’s simple operation concept, the clamped-clamped beam was selected for detailed parametric characterization due to its comprehensive modeling approach. The beam detects at least 5% helium concentration levels when excited at 3.8 MHz, near electrical resonance. The switch performance decreases at lower excitation frequencies or increases the circuit resistance. The MEMS sensor detection level was relatively immune to beam thickness and parasitic capacitance changes. However, higher parasitic capacitance increases the switch’s susceptibility to errors, fluctuations, and uncertainties.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Assessment of MODIS Scan Mirror Reflectance Changes On-Orbit

Since launch, the NASA EOS Terra and Aqua MODIS have operated successfully for more than 8 and 6 years, respectively. MODIS collects data using a two-sided scan mirror over a large scan angular range. The scan mirror is made of a polished, nickel-plated beryllium base coated with high purity silver, which is then over-coated with the Denton proprietary silicon monoxide and silicon dioxide mixture. The scan mirror's reflectance was characterized pre-launch using its witness samples, and the response versus scan angle was measured at the sensor system level. In this study, we present an assessment of MODIS scan mirror on-orbit degradation by examining changes of spectral band response over each sensor's mission lifetime. Results show that the scan mirror's optical properties for both Terra and Aqua MODIS have experienced significant degradation since launch in the VIS spectral region, which is mirror side dependent as well as scan angle dependent. In general, the mirror degradation is more severe for Terra MODIS than Aqua MODIS, especially during recent years. For Terra MODIS, the degradation rate is noticeably different between the mirror sides. On the other hand, there has been little mirror side dependent difference for Aqua MODIS.

Xiong, Xiaoxiong↗

Regressing Nuclear Reactor Power Level Using Low-Cost Sensor Network Data

Multisensor networks deployed at nuclear facilities can be leveraged to collect data used as inputs to machine learning models predicting nuclear safeguard relevant information. This work demonstrates an application of this idea by regressing nuclear reactor power levels, a key indicator for nuclear safeguard verification, at the McClellan Nuclear Research Center using data collected by five Merlyn multisensor platforms with LASSO and LSTM models. This work also demonstrates the use of Leave One Node Out to measure the importance of each multisensor for this regression problem providing insight into model explainability and allowing inferential hypotheses about the nuclear facility to be made. This work can be used as a starting point for future development of methods for regression on reactor power levels at nuclear facilities using multisensor network data.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Detecting Low-level Radiation Sources Using Border Monitoring Gamma Sensors

We consider a problem of detecting a low-level radiation source using a network of Gamma spectral sensors placed on the periphery of a monitored region. We propose a computationally light-weight, correlation-based method which is primarily intended for systems with limited computing capacity. Sensor measurements are combined at the fusion by first generating decisions at each time step and then taking their majority vote within a time widow. At each time step, decisions are generated using two strategies: (i) SUM method based on a threshold decision on a correlation statistic derived from measurements from all sensors, and (ii) OR method based on logical-OR of threshold decisions based on correlations statistics of individual sensor measurements. We derive analytical performance bounds for false alarm rates of SUM and OR methods, and show that their performance is enhanced by the temporal smoothing of majority vote within a time window. Using measurements from a test campaign, we generate a border monitoring scenario with twelve 2"x2" NaI Gamma sensors deployed on the periphery of 42m x 42m outdoor region. A Cs-137 source is moved in a straight-line across this region, starting several meters outside and finally moving away from it. We illustrate the performance of both correlation-based detection methods, and compare their performances with each other and with a particle filter method. Overall, under small false-alarm conditions, the OR fusion is found to produce better detection performance.

Sen, Satyabrata↗

Generalized parity relations for large space structures with uncertain parameters

The generalized parity relations method is a technique that can be used to detect sensor and actuator failures on a large space structure. A model of a grid structure was used to evaluate the performance of these relations. It shows their relative sensitivity to modeling errors. A method using sensor outputs and actuator inputs is required for the design of the generalized parity relations. Three different estimators are studied. The last estimator can generate relations optimized for the detection of a particular failure which are interesting when the level of sensor noise is high.

Dutilloy, J. R.↗

Detecting Sensors and Inferring their Relations at Level-0 in Industrial Cyber-Physical Systems

While there exist tools and techniques to discover, identify, map, and analyze cyber physical components at higher levels of the cyber space, there is a lack of capabilities to reach down to the sensors at the bottom-most levels, such as levels 0 and 1 of the Purdue Enterprise Reference Model for cyber-physical systems (CPS). Conventional information technology (IT)-based tools reach as far as the network-side of programmable logic controllers, but are inadequate to access and analyze the physical side of the CPS infrastructure that directly interfaces with the actual physical processes and systems. In this paper, we present our research and development efforts aimed at addressing this gap, by building a system called Deep-cyberia (Deep Cyber-Physical System Interrogation and Analysis) that incorporates algorithms and interfaces aimed at uncovering sensors and computing estimates of correlations among them.

Perumalla, Kalyan↗

Comparison of Power System Current Sensors via Playback of Electrical Disturbances

The need to accurately measure high-frequency content in power system voltage and current phenomena is increasingly becoming more of a priority. As the amount of distributed energy resources (DER) and nonlinear loads penetrating the grid increases, so do challenges associated with traditional measurement and metering applications. In this paper, three commercially-available medium-voltage-level current sensors are characterized in terms of their harmonic amplitude and phase performance against reference signals that are “played back” through the sensors through the use of an arbitrary waveform generator. It is shown that none of the three sensors studied are able to faithfully replicate all of the input signals completely, though there are advantages and disadvantages to each in terms of noise, resonance, and induced phase drift. Additionally, the Goodness-of-Fit metric, typically used for PMU model validation, is used to generate side-by-side comparisons of sensor accuracy over a small window around the events under study.

Wilson, Aaron↗