Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “leak test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Results of Multiple Tracer Injections into Fractures in the EGS Collab Testbed-1

The EGS Collab project constructed an intermediate scale (~10-20 m) testbed at the 4850 level of the Stanford Underground Research Facility (SURF) in South Dakota for testing and validating fracture stimulation and flow/transport models. This testbed consists of eight ~200 ft (~60 m) HQ-diameter (9.6 cm) boreholes that are drilled into the crystalline rocks of the Poorman Formation from the West Access Drift tunnel. Of the eight boreholes, one borehole is used as an injection/stimulation well, while another sub-parallel borehole located about 10 m away from the injection well is used as a production well, and rest of the other boreholes are used as geophysical/fluid sampling monitoring wells. Hydraulic stimulation activities were conducted at three locations along the injection hole in an attempt to create direct fracture connections to the production hole. A flow system has been established between injection and production boreholes through a set of hydraulically stimulated fractures propagated from a notch located at 164 ft in the injection hole. Although we planned for a single production well, a set of natural fractures in the testbed is believed to have intersected the stimulated hydraulic fractures and provided additional flow paths for water to be transported to the drift through multiple monitoring boreholes and weep zones. As the flow tests continued after stimulation activities, single or a combination of two or three producers become dominant producers at different times, mostly as a response to intersection of hydraulic fracture and testbed wells, activation of natural fractures and making new leak points to the monitoring wells, resealing of leaky wells, and so on. Since late October 2018, multiple tracers were injected into the fracture system at the 164 ft location that involves both stimulated and natural fractures, and tracers were recovered from multiple locations in nearby wells and weep. The cumulative water recoveries over the time have ranged from 50 to 90%; however, the injected tracer recoveries from various production sources are much less (ranging from a few percentages to 38%). Changes in water/tracer recoveries, shifting of major producing wells from one well to the others, and other observations (e.g., microseismic, electric resistivity tomography, etc.) indicate a testbed that has undergone several changes since October 2018. In this paper, we present tracer recovery data accumulated during several tracer campaigns, provide conceptual testbed flow pathways, and provide observations that suggest a evolutionary nature of fracture volume and fracture geometry in the testbed.

15 GEOTHERMAL ENERGY↗

Advanced Autonomous Welding for Refabrication and Follow-On Testing of Previously Irradiated Nuclear Fuel

The performance of follow-on experiments using irradiated nuclear fuel at any point in its lifecycle is a critical step in understanding phenomena and behavior. Transient experiments with high-burnup fuel can deepen the understanding of fuel fragmentation, relocations, and dispersal under loss-of-coolant accidents. An advanced autonomous welding process to refabricate commercial fuel rods inside a hot cell was created and tested to enable flexible experiment approaches on fuels irradiated in commercial and test reactors. Irradiated light water reactor fuel test pins from experiments performed at the Advanced Test Reactor (ATR) at Idaho National Laboratory were used to demonstrate the refabrication process. The welding process was found to be sensitive to welding parameters but flexible such that multiple passes could be performed on the same location until a hermetic weld was obtained. The refabrication of rodlets and successful welds was also found to be sensitive to the preparation of the irradiated cladding and endcaps. Thorough defueling of the fuel at the weld location and proper sizing of the endcaps and backing material mitigated these issues. The use of strategically located heat sinks in contact with the cladding and endcap materials also increased welding and refabrication success. For this work, the test pins were sectioned to remove the original endcaps and fuel was removed from both ends of each rodlet. The reassembly of the rodlets was then completed in four steps, which included the press fitting of new endcaps, the circumferential welding of rodlet endcaps to the cladding, rodlet pressurization in a pressure chamber, and seal welding the rodlet under pressure. The integrity of the refabricated rodlets was then verified via helium leak checking inside a vacuum chamber. The advanced welding system is capable of refabricating rodlets up to 380 mm in length, and repressurizing them up to 15 500 kPa. The refabricated lengths of the rodlets used in this work ranged from 149 to 165 mm and the refabricated fuel stack heights ranged from 70.4 to 79.8 mm. Here, the rodlets were pressurized with argon to an average pressure of 3617 kPa, and the average leak rate after refabrication was 6.7 • 10 -8 cm 3 • s -1 .

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Electrical design of the flexible imaging diffraction diagnostic for laser experiments (FIDDLE) at the National Ignition Facility (NIF)—Requirements, design, and performance

The Flexible Imaging Diffraction Diagnostic for Laser Experiments (FIDDLE) is a newly developed diagnostic for imaging time resolved diffraction in experiments at the National Ignition Facility (NIF). It builds on the successes of its predecessor, the Gated Diffraction Development Diagnostic (G3D). The FIDDLE was designed to support eight Daedalus version 2 sensors (six more hCMOS sensors than any other hCMOS-based diagnostic in NIF to date) and an integrated streak camera. We will review the electrical requirements, design, and performance of the electrical subsystems that were created to support this large number of cameras in the FIDDLE. The analysis of the data that the FIDDLE is intended to collect relies heavily on the accurate and well-understood timing of each sensor. We report camera-to-camera timing jitter of less than 100 ps rms and sensor integration times of 2.2 ns FWHM in 2-2 timing mode. Additionally, diffraction experiments on the NIF produce electric fields (EMI) on the order of 1 kV/m, which have been observed to negatively impact the performance of some electrical components of the FIDDLE. We report on the results of testing hCMOS camera electronics in a similar EMI environment generated in an offline lab. In addition, we also summarize the use of a novel approach to using a vector network analyzer as an EMI leak detector to understand and reduce the negative impacts of EMI on the FIDDLE.

47 OTHER INSTRUMENTATION↗

Estimation of sensor measurement errors in reactor coolant systems using multi-sensor fusion

A nuclear power plant is typically instrumented with a variety of sensors to continually monitor its variables, and their sensor’s measurements may be used to assess the plant state and initiate safety actions, if needed. Errors in sensor measurements, due to factors such as calibration drifts, critically affect such state assessments. Here, we address a problem of estimating sensor errors using physics-informed machine learning methods that use measurements collected under known plant conditions. For a given sensor, we propose an information fusion method that uses measurements from other sensors to estimate its output assuming it is error-free and provides its difference from an actual measurement as an error estimate. We present the ensemble of trees and support vector machine fusers, and evaluate their performance using measurements collected over an emulated test loop of a pressurized water reactor. The plant variables are related to each other through the underlying physical laws under inertial constraints that place bounds on their derivatives, which analytically justify the applicability of machine learning methods for computing these fusers. Under twenty scenarios, we assess their sensor error estimates for pressure sensors of the heat exchanger of a reactor’s primary coolant system. Multiple types of errors are captured by both fusers under externally induced calibration drifts, blockages, minor leaks and air gaps in sensing lines, and electromagnetic interference; the root mean square error of the estimation of error is under 2.2% percent of the maximum measurement. We present generalization equations, in the framework of statistical learning theory, for these methods that characterize the confidence probability that the estimation error is bounded by a specified parameter in future test scenarios.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Relative permeabilities for two-phase flow through wellbore cement fractures

Multiple fluids are likely to exist in fractures and flow paths associated with leaky wellbores, including liquids (e.g., crude oil) and gases (e.g., gas exsolved from liquid). These fluids occupy and move through different portions of the pore spaces within the fractures depending on many factors, including fluid properties, fracture size, and the amount of the different fluids. Upward leakage of any phase, through the fracture, can contaminate water-bearing formations, create hazardous surface conditions, and compromise the functionality of the wellbore. Early signs of wellbore leaks may be expressed by anomalous pressure behavior at surface monitoring points on cavern storage wells. These pressure anomalies are difficult to interpret, necessitating knowledge of the factors that affect the multiphase flow in fractures and porous media. These parameters are critical to modeling multiphase flow in fractures. This insight can guide further diagnosis and maximize leak remediation. Here, our study focuses on the relationship of the liquid–gas relative permeabilities for representative variable-aperture wellbore cement fracture. To obtain the relative permeability of each phase, two-phase flow tests were conducted where both fluids were flowing simultaneously through a fractured wellbore cement specimen under a range of factors, namely (1) aperture size, (2) capillary numbers, and (3) viscosity ratio. The flow experiments were conducted under a range of confining stresses and flow velocities, using nitrogen gas and silicone oils (of different viscosities) in a specially designed pressure vessel. The sum of gas and oil relative permeabilities were found to be less than one under all conditions, which indicates that the presence of one phase affects the permeability of the other phase, and vice versa. Since the gas phase flow conditions include a significant inertial flow component in addition to viscous flow, the inertial flow coefficients at different saturation states are presented. The factors affecting the relationship between the relative permeabilities are discussed in detail. A new mathematical model for estimating the relative permeability of wellbore cement fracture is presented and experimentally validated.

58 GEOSCIENCES↗

Feasibility of using thermal response methods for nonintrusive compressed air flow measurement

Robust, low-cost nonintrusive flow meters are of interest in many industries. Particularly, a reliable nonintrusive flow measurement for the diagnosis of air leaks in compressed air systems is desirable. Measurement of the air flow due to leaks in the system ensures an accurate estimation of potential cost and energy savings. This study evaluates a novel method of using thermal responses to nonintrusively measure leakage rates in compressed air lines. The method uses heat and the resulting thermal response to calculate the flow rate inside the compressed air line. Compared to the current methods for flow measurement, this method can simplify flow measurement while decreasing the sensitivity to errors when measuring flow rates. In this study, the methodology of the proposed method is explained along with the potential advantages to the design. Two approaches are evaluated: a dynamic step response and sinusoidal frequency response. Simulated tests evaluate the feasibility of the proposed methods, followed by experiments that validate the simulation results. A clear correlation between the thermal step response and the flow rate indicate viability of the proposed method in simulation. Experimental results yielded similar results, confirming the validity of the proposed method. The results of a field test in an industrial environment demonstrate the capability of the approach to other flow rate measurement techniques.

42 ENGINEERING↗

Improving air leakage prediction of buildings using the fan pressurization method with the Weighted Line of Organic Correlation

In many countries, the fan pressurization method is the most frequently chosen approach for measuring the air leakage of houses. The measurements are usually performed at pressures that far exceed pressures to which buildings are exposed to under normal conditions. A fit of these tests to the power-law formulation allows an extrapolation to data points outside the measured pressure range. With the Ordinary Least Square (OLS) fitting method, the pressure exponent and flow coefficient can be determined. However, the measurement results are highly sensitive to uncertainties induced by external factors like changing wind conditions during the tests, which is neglected by OLS. This may lead to errors in the prediction of flows at lower pressures. The Weighted Line of Organic Correlation (WLOC) is an alternative approach and takes measurement uncertainty into account. In this paper, a statistical analysis of an extensive data set of pressurization measurements has been performed. Both regression techniques have been compared for almost 7500 fan pressurization measurements of six houses in 109 different house leak configurations. The variability in predicting pressure exponent and flow coefficient for both WLOC and OLS regression was analyzed using probability density functions. It was found that the Weighted Line of Organic Correlation significantly decreases the uncertainty in predicting pressure exponent, flow coefficient, and other low-pressure air leakage metrics compared to the Ordinary Least Square fitting. Here, the authors highly recommend the implementation of WLOC in current measurement standards and test equipment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Shielded and Low-Damping SPM Probes for Quantitative Electrical and Electrochemical Characterization (Phase IIA)

The purpose of this DOE SBIR award was to develop new scanning probe microscopy tools for the elucidation of electrical and electrochemical properties at the nanoscale. High performance probes are important for energy materials research. In both solar cells and batteries, the essential physics and chemistry occur at the nanoscale and nanoscale characterization tools are required for their elucidation. Two products were developed: an electrically shielded probe and an electrically conductive probe with low leakage currents. Our processes were based on post processing of existing probes and fabrication methods were tested, leading to a laser micromachining based approach that led to the first minimal viable product. We invented a method to make a reliable electrical contact that attaches a flexible printed circuit board to the chip. enable leak-free operation crucial when used in conductive liquids and electrolytes. This proprietary solution improves chip handling, reduces contamination, and maintains effective electrical contact. The probes fabricated in this Phase IIa are a minimal viable product which attracted attention from various tip manufacturers and instrument manufacturers alike.

36 MATERIALS SCIENCE↗

High Force Spring Clamp System

This is the Final Technical Report for the work by Hyperboloid LLC using SBIR Grant # DE-SC0019579. The work responded to US DOE SBIR Topics FY2019, Phase 1, Release 1, August 13 2018, Topic: 30. a. (2) SRF cavity joining techniques that create vacuum seals without resorting to the use of bolted flanges in order to minimize particulates. Hyperboloid LLC designed, developed and tested the High Force Spring Clamp System characterized in Patent US 9756715 that is aimed at solving this topic. The patent is held by Thomas Jefferson National Accelerator Facility. The flange bolts are substituted with exceptionally high force, binder-clip-like “C” Clamps. The clamps are opened and applied by hydraulic based tooling called “Clamp Openers” using particle minimization methods. Model 1 Clamp reached the goal of sealing the SRF industry standard hexagonal section, aluminum alloy gasket, leak-free on a research cavity as determined by a superfluid helium challenge, at 2 K for 2 assembly cycles. Descriptions include the ANSYS calculations that determine the size and shape of the clamp, the details of the Clamp Opener construction, particle counts from sealing flanges using both bolts and clamps. Model 2 Clamp, at half the size, needing a softer metallic gasket to be successful, is more readily adaptable to Cryomodule designs. It was tested, but a needs soft gasket development to be successful.

43 PARTICLE ACCELERATORS↗

Two-Phase Cooling for High Packaging Density Planar Inverter: Cooperative Research and Development Final Report, CRADA Number CRD-15-00592

The project objective was to utilize two-phase heat transfer to enable compact and power-dense inverters. The high heat transfer capacity and near isothermal characteristics of two-phase cooling can enable higher power densities, reducing the size and cost of the power electronics system. This project focused on developing efficient, passive (no pump or compressor) two-phase cooling strategies that consist of an air-cooled condenser and evaporator. This report describes the modeling work conducted to design the evaporator and air-cooled condenser for a prototype inverter development work underway in the John Deere. Prototypes of the final evaporator and condenser designs were then fabricated via 3D printing for testing. Experiments on the evaporator confirmed that this component can meet the heat load and junction temperatures requirements for Si IGBT (insulated-gate bipolar transistor) inverter. Experiments with the air-cooled condenser were not possible due to leaks through the condenser walls.

33 ADVANCED PROPULSION SYSTEMS↗

Surface Acoustic Wave Sensors for Refrigerant Leak Detection: Compact, Inexpensive, Selective and Sensitive Sensors

Pacific Northwest National Laboratory (PNNL), in collaboration with Parker and Hannifin, is developing a compact, inexpensive, and highly sensitive and selective surface acoustic wave sensor coated with fluorophillic sorbent for detecting fluorocarbon leaks from HVAC systems. Having a highly effective sorbent sensitive to fluorocarbon refrigerant vapors provides a means to develop a sensing device for leak detection. Surface acoustic wave (SAW) sensors with a gas sensing film deposited between the delay lines or on the interdigital transducer have been used to detect gas and vapor molecules in harsh environments with high sensitivity. As part of this project, PNNL screened several sorbent materials that are shown to be selective towards fluorocarbon refrigerant (R32) molecule. The identified sorbent materials were synthesized, characterized, and tested towards R32 using various spectroscopic technique. Next, the sorbent material was coated on a SAW sensor as a thin film using vapor deposition and drop coating methods. The coated thin film was further characterized and tested towards the detection of pure R32 and R32 in ambient air at room temperature to demonstrate the SAW response towards R32 in presence of other competing gases and vapors in air.

42 ENGINEERING↗

A NUMERICAL STUDY OF REFRIGERANT LEAKAGE FROM A PROPANE-BASED REFRIGERATION SYSTEM

Low Global Warming Potential (GWP) refrigerants, e.g. Propane (R290) (GWP = 3) and R1234yf (GWP = 4), are becoming a popular choice among refrigeration and HVAC systems, such as vending machines and air conditioning. However, most of Low GWP refrigerants are flammable (ASHRAE class A2 or A3), so safety is a very important consideration when designing and deploying low GWP refrigerants-based equipment in buildings. In the event of a refrigerant leak, the flammability of low GWP refrigerants depends on the local concentration of the refrigerant within the vicinity of the leak. In addition, the low GWP refrigerants concentration is affected by the indoor air environment, such as air flow rate and temperature. In the present study, a computational fluid dynamics (CFD) model is developed to model the flow and temperature of air surrounding a propane-based refrigeration system, as well as the concentration of leaked low GWP refrigerants surrounding the refrigeration system. The model results reveal the concentration distribution of low GWP refrigerants within the building, and as a result, the flammable regions within the building can be identified. Moreover, different ventilation layouts will be tested using the model to improve the design of ventilation. The numerical model can assist in the design of ventilation systems to minimize flammable regions within buildings due to leakage of flammable refrigerants.

Zhang, Mingkan↗

Automated fault detection of residential air-conditioning systems using thermostat drive cycles

Residential air conditioning equipment comprises a significant portion of the total energy consumption of a home. Unfortunately, air-conditioning systems can be susceptible to faulty operation either from installation errors or faults that accrue over the equipment’s lifetime. This paper presents a novel automated fault detection algorithm for residential air-conditioning systems that can alert the homeowner of the presence of these faults. The proposed algorithm utilizes only the home’s thermostat and outside air temperature to perform automated fault detection over the course of the equipment’s lifetime, including immediately after installation. The algorithm uses an extended Kalman filter approach to identify a three-resistor, two-capacitor (3R2C) electrical equivalent thermodynamic model. The identified 3R2C model is used to predict cooling times during a testing period comprising of a series of thermostat drive-cycle experiments. We tested the algorithm on an EnergyPlus™ model of a typical residential building in Orlando, Florida. Duct faults, indoor airflow faults, and refrigerant undercharge faults were introduced into the building model one at a time. The algorithm was able to accurately determine duct-leak faults, 40% airflow faults, 40% undercharge faults, and no-fault cases with an accuracy of 70%, 77%, 82%, and 87%, respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of a forced advection sampling technique (FAST) for quantification of methane emissions from orphaned wells

Abstract. Orphaned wells, meaning unplugged and non-producing wells lacking responsible owners, pose a significant and undersampled environmental challenge due to their vast number and unknown associated emissions. We propose, develop and test an alternative method for estimating emissions from orphaned wells using a forced advection sampling technique (FAST) that can overcome many of the limitations in current methods (cost, accuracy, safety). In contrast to existing ambient Gaussian plume methods, our approach uses a fan-generated flow to force advection between the emission source and a point methane (CH4) sensor. The fan flow field is characterized using a colocated sonic anemometer to measure the 3D wind profile generated by the fan. Using time-series measurements of CH4 concentration and wind, a simple estimate of the CH4 emission rate of the source can be inferred. The method was calibrated using outdoor controlled-release experiments and then tested on four orphaned wells in Lufkin, TX, and Osage County, OK. Our results suggest that the FAST method can provide a low-cost, portable, fast and safe alternative to existing methods with reasonable estimates of orphaned well emissions over a range of leak rates below 40 g h−1 and within certain geometric and atmospheric constraints.

Dubey, Mohit L↗

INL Contributions to Draft HTTF Benchmark Specifications

The High-Temperature Test Facility (HTTF) is an integral effects thermal hydraulics test facility at Oregon State University designed as a 1/4 length scale model of the Modular High-Temperature Gas-Cooled Reactor 350 MW core (mHTGR-350). In the spring and summer of 2019, several experiments were conducted at HTTF providing a valuable source of gas-cooled reactor thermal hydraulics data. Idaho National Laboratory (INL), Oregon State University, Argonne National Laboratory, and Canadian Nuclear Laboratories have partnered to use this experimental data to develop a gas-cooled reactor thermal hydraulics benchmark led by INL under the auspices of the Advanced Reactor Technologies (ART) program. This report provides some context on the benchmark, HTTF, and previous Reactor Excursions and Leak Analysis Program (RELAP)5-3D modeling of HTTF. It also provides a draft of the benchmark specifications for the Depressurized Conduction Cooldown problem, which is the INL-led benchmark problem.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Assessing the Potential Impact of Fugitive Methane Emissions on Offshore Platform Safety

One of the biggest risks to safety on offshore platform safety is the ignition of high-pressure natural gas streams. Currently, the size and number of fugitive emissions on offshore platforms is unknown and methods used to detect fugitives have significant shortcomings. To investigate the frequency, size, and potential impact of fugitives, a data collection exercise was conducted using incidents reported, leak survey data, and independent measurements. The size and number of fugitives on offshore facilities were simulated to investigate likely areas of safety concern. Incident reports indicate in 2021 there were 113 reports of gas leaks on 1119 offshore facilities, suggesting 0.02 fugitives per Type 1 facility (older, shallow-water platforms) and 0.31 fugitives per Type 2 facility (larger deeper-water facilities). Leak survey data report 12 fugitives per Type 1 facility (average emission 0.6 kg CH 4 h −1 leak −1 ) and 15 fugitives per Type 2 facility (average emission 1.5 kg CH 4 h −1 leak −1 ). Reconciliation of direct measurements with a bottom-up model suggests that the number of fugitive emissions generated from the leak report data is an underestimate for Type 1 platforms (44 fugitives facility −1 ; average emission 0.6 kg CH 4 h −1 leak −1 ) and in general agreement for the Type 2 platforms (15 fugitives facility −1 ; average emission 1.5 kg CH 4 h −1 leak −1 ). Analysis of the fugitive emission rates on an offshore platform suggests that gas will not collect to explosive concentration if any air movement is present (>0.36 mph); however, large volumes of air (~600 m 3 ) near representative leaks on the working deck could become explosive in hour-long zero-wind conditions. We suggest that wearable technology could be employed to indicate gas build up, safety regulations amended to consider low-wind conditions and real-world experiments are conducted to test assumptions of air mixing on the working deck.

explosion↗

COMPUTATION FLUID DYNAMICS ANALYSIS FOR GENERIC SMALL MODULAR REACTOR CONTAINMENT SEPARATE EFFECTS TEST

It is desirable for fourth-generation Small Modular Reactors to be passively cooled in standard and accident operations. Passive Containment Cooling Systems can reject heat from the containment structure, without using pumps or blowers. The targeted design containment structure is a large, domed, stainless steel, cylindrical vessel. In a postulated Design Basis Accident, steam will flash inside containment. Steam condensation occurs on the inner containment wall and transfers heat through the steel containment into a large body of water known as the annular reservoir (AR) surrounding the vessel serving as the ultimate heat sink. Natural circulation drives the flow in the AR and heat will be released to the environment by evaporation of water. Unique containment geometry requires a separate effects test (SET) facility for the verification and validation of the computer code and evaluation model development and assessment for reactor licensing efforts. In this study, STAR-CCM+, a computational fluid dynamics (CFD) code was used to inform the decision-making process on the design of the SET. The CFD simulation modeled, a two-phase turbulent flow with fluid film development and heat transfer for different containment geometries. The Reactor Excursion and Leak Analysis Program will also be used in a code-to-code verification against the CFD results.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Microphonics in the LCLS-II Superconducting Linac

The LCLS-II project has installed a new superconducting linac at SLAC that consists of 35 1.3 GHz cryomodules and 2 3.9 GHz cryomodules. The linac will provide a 4 GeV electron beam for generating soft and hard X-ray pulses. Cavity detuning induced by microphonics was a significant design challenge for the LCLS-II cryomodules. Cryomodules were produced that were within the detuning specification (10 Hz for 1.3 GHz cryomodules) on test stands. Here we present first measurements of the microphonics in the installed LCLS-II superconducting linac. Overall, the microphonics in the linac are manageable with 94% of cavities coming within the detune specification. Only two cavities are gradient limited due to microphonics. We identify a leaking cool down valve as the source of microphonics limiting those two cavities.

43 PARTICLE ACCELERATORS↗