Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “laser operations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

A survey of laser lightning rod techniques

The work done to create a laser lightning rod (LLR) is discussed. Some ongoing research which has the potential for achieving an operational laser lightning rod for use in the protection of missile launch sites, launch vehicles, and other property is discussed. Because of the ease with which a laser beam can be steered into any cloud overhead, an LLR could be used to ascertain if there exists enough charge in the clouds to discharge to the ground as triggered lightning. This leads to the possibility of using LLRs to test clouds prior to launching missiles through the clouds or prior to flying aircraft through the clouds. LLRs could also be used to probe and discharge clouds before or during any hazardous ground operations. Thus, an operational LLR may be able to both detect such sub-critical electrical fields and effectively neutralize them.

Barnes, Arnold A., Jr.↗

High Repetition Rate Pulsed 2-Micron Laser Transmitter for Coherent CO2 DIAL Measurement

A high repetition rate, highly efficient, Q-switched 2-micron laser system as the transmitter of a coherent differential absorption lidar for CO2 measurement has been developed at NASA Langley Research Center. Such a laser transmitter is a master-slave laser system. The master laser operates in a single frequency, either on-line or off-line of a selected CO2 absorption line. The slave laser is a Q-switched ring-cavity Ho:YLF laser which is pumped by a Tm:fiber laser. The repetition rate can be adjusted from a few hundred Hz to 10 kHz. The injection seeding success rate is from 99.4% to 99.95%. For 1 kHz operation, the output pulse energy is 5.5mJ with the pulse length of approximately 50 ns. The optical-to-optical efficiency is 39% when the pump power is 14.5W. The measured standard deviation of the laser frequency jitter is about 3 MHz.

Singh, Uprendra N.↗

Inversion of the resonance line of Sr/+/ produced by optically pumping Sr atoms

A description is presented of an experiment which demonstrates the selective production of excited-state ions by an optical absorption from neutrals. An inversion on the resonance line of Sr(+) was produced by laser excitation of a two-electron transition, followed by ionization of one of the excited electrons by the same laser. A pulsed, mode-locked laser operating at 2680 A was used to excite atoms from the Sr ground level. The same laser then ionized the excited atoms. The 2680-A pump beam was generated by frequency doubling the output of a synchronously pumped mode-locked dye laser in a KDP crystal. It is pointed out that the reported results are significant for the construction of vacuum-ultraviolet and X-ray lasers. Many of the proposed methods for making such lasers depend on the selective production of excited-state ions.

Green, W. R.↗

Low Power Consumption Lasers for Miniature Optical Spectrometers for Trace Gas Analysis

The air quality of any manned spacecraft needs to be continuously monitored in order to safeguard the health of the crew. Air quality monitoring grows in importance as mission duration increases. Due to the small size, low power draw, and performance reliability, semiconductor laser-based instruments are viable candidates for this purpose. Achieving a minimum instrument size requires lasers with emission wavelength coinciding with the absorption of the fundamental absorption lines of the target gases, which are mostly in the 3.0-5.0 micron wavelength range. In this paper we report on our progress developing high wall plug efficiency type-I quantum-well GaSb-based diode lasers operating at room temperatures in the spectral region near 3.0-3.5 micron and quantum cascade (QC) lasers in the 4.0-5.0 micron range. These lasers will enable the development of miniature, low-power laser spectrometers for environmental monitoring of the spacecraft.

Distributed Feedback (DFB) Diode Lasers↗

Low Power Consumption Lasers for Next Generation Miniature Optical Spectrometers for Major Constituent and Trace Gas Analysis

The air quality of any manned spacecraft needs to be continuously monitored in order to safeguard the health of the crew. Air quality monitoring grows in importance as mission duration increases. Due to the small size, low power draw, and performance reliability, semiconductor laser-based instruments are viable candidates for this purpose. The minimum instrument size requires lasers with emission wavelength coinciding with the absorption of the fundamental frequency of the target gases which are mostly in the 3.0-5.0 micrometers wavelength range. In this paper we report on our progress developing high wall plug efficiency type-I quantum-well GaSb-based diode lasers operating at room temperatures in the spectral region near 3.0-3.5 micrometers and quantum cascade (QC) lasers in the 4.0-5.0 micrometers range. These lasers will enable the development of miniature, low-power laser spectrometers for environmental monitoring of the spacecraft.

semiconductor lasers↗

Laser induced OMCVD growth of AlGaAs on GaAs

A major factor limiting the efficiency of the GaAs-GaAlAs solar cell is the rate of recombination at the GaAs-AlGaAs interface. Evidence has been previously reported which indicates that recombination at this interface can be greatly reduced if the AlGaAs layer is grown at lower than normal temperatures. The authors examine the epitaxial growth of AlGaAs on GaAs using a horizontal OMCVD reactor and an excimer laser operating in the UV (lambda = 193 nm) region. The growth temperatures were 450 and 500 C. The laser beam was utilized in two orientations: 75 deg angle of incidence and parallel to the substrate. Film composition and structure were determined by Auger electron spectroscopy (AES) and transmission electron microscopy (TEM). Auger analysis of epilayers grown at 500 C with the laser impinging show no carbon or oxygen contamination of the epitaxial layers or interfaces. TEM diffraction patterns of these same epilayers exhibit single crystal (100) zone axis patterns.

Wilt, David M.↗

High Energy, Single-Mode, All-Solid-State Nd:YAG Laser

In this paper, recent progress made in the design and development of an all-solid-state, single longitudinal mode, conductively cooled Nd:YAG laser operating at 1064 nm wavelength for UV lidar for ozone sensing applications is presented. Currently, this pump laser provides an output pulse energy of greater than 1.1 J/pulse at 50 Hz PRF and a pulsewidth of 22 ns. The spatial profile of the output beam is a rectangular super Gaussian. Electrical-to-optical system efficiency of greater than 7% and a minimum M(sup 2) value of less than 2 have been achieved.

Prasad, Narasimha S.↗

Low Power Consumption Laser for Next Generation Miniature Optical Spectrometers for Trace Gas Analysis

The air quality of any manned spacecraft needs to be continuously monitored in order to safeguard the health of the crew. Air quality monitoring grows in importance as mission duration increases. Due to the small size, low power draw, and performance reliability, semiconductor laser-based instruments are viable candidates for this purpose. Achieving a minimum instrument size requires lasers with emission wavelength coinciding with the absorption of the fundamental absorption lines of the target gases, which are mostly in the 3.0-5.0 mu m wavelength range. In this paper we report on our progress developing high wall plug efficiency type-I quantum-well GaSb-based diode lasers operating at room temperatures in the spectral region near 3.0-3.5 mu m and quantum cascade (QC) lasers in the 4.0-5.0 mu m range. These lasers will enable the development of miniature, low-power laser spectrometers for environmental monitoring of the spacecraft

distributed feedback laser (DFB↗

Large mode radius resonators

Resonator configurations permitting operation with large mode radius while maintaining good transverse mode discrimination are considered. Stable resonators incorporating an intracavity telescope and unstable resonator geometries utilizing an output coupler with a Gaussian reflectivity profile are shown to enable large radius single mode laser operation. Results of heterodyne studies of pulsed CO2 lasers with large (11mm e sup-2 radius) fundamental mode sizes are presented demonstrating minimal frequency sweeping in accordance with the theory of laser-induced medium perturbations.

Harris, Michael R.↗

A 163 micron laser heterodyne radiometer for OH

A 163 micron (1.836 THz) radiometer developed for airplane and/or balloon platforms is described. The laser local oscillator is a CO2 pumped methanol laser operating at a frequency which is approx. 1 GHz from the J = 3/2 - 1/2 transition of OH. The laser is used directly as a local oscillator or is translated in frequency to closer coincidence with the OH emission, depending on achieved detector IF bandwidth. Frequency translation techniques which are described are diode mixing and a method of single sideband generation using an external Stark modulated gas cell. The photoconductive mixer used is a strained Ge crystal, doped with Ga, originally used as an incoherent detector. The uniaxial strain on the Ga doped Ge crystal shifts the threshold for photoconduction from 100/cm to frequencies as low as 50/cm. These detectors are currently being characterized as mixers in the laboratory. Of particular interest are the effect of local oscillator power and strain on IF, bandwidth detector impedance, and conversion loss. Preliminary results of these tests are described and compared with theorectical expectations.

Pickett, H. M.↗

The nonlinear wave equation for higher harmonics in free-electron lasers

The nonlinear wave equation and self-consistent pendulum equation are generalized to describe free-electron laser operation in higher harmonics; this can significantly extend their tunable range to shorter wavelengths. The dynamics of the laser field's amplitude and phase are explored for a wide range of parameters using families of normalized gain curves applicable to both the fundamental and harmonics. The electron phase-space displays the fundamental physics driving the wave, and this picture is used to distinguish between the effects of high gain and Coulomb forces.

Colson, W. B.↗

Laser High-Cycle Thermal Fatigue of Pulse Detonation Engine Combustor Materials Tested

Pulse detonation engines (PDE's) have received increasing attention for future aerospace propulsion applications. Because the PDE is designed for a high-frequency, intermittent detonation combustion process, extremely high gas temperatures and pressures can be realized under the nearly constant-volume combustion environment. The PDE's can potentially achieve higher thermodynamic cycle efficiency and thrust density in comparison to traditional constant-pressure combustion gas turbine engines (ref. 1). However, the development of these engines requires robust design of the engine components that must endure harsh detonation environments. In particular, the detonation combustor chamber, which is designed to sustain and confine the detonation combustion process, will experience high pressure and temperature pulses with very short durations (refs. 2 and 3). Therefore, it is of great importance to evaluate PDE combustor materials and components under simulated engine temperatures and stress conditions in the laboratory. In this study, a high-cycle thermal fatigue test rig was established at the NASA Glenn Research Center using a 1.5-kW CO2 laser. The high-power laser, operating in the pulsed mode, can be controlled at various pulse energy levels and waveform distributions. The enhanced laser pulses can be used to mimic the time-dependent temperature and pressure waves encountered in a pulsed detonation engine. Under the enhanced laser pulse condition, a maximum 7.5-kW peak power with a duration of approximately 0.1 to 0.2 msec (a spike) can be achieved, followed by a plateau region that has about one-fifth of the maximum power level with several milliseconds duration. The laser thermal fatigue rig has also been developed to adopt flat and rotating tubular specimen configurations for the simulated engine tests. More sophisticated laser optic systems can be used to simulate the spatial distributions of the temperature and shock waves in the engine. Pulse laser high-cycle thermal fatigue behavior has been investigated on a flat Haynes 188 alloy specimen, under the test condition of 30-Hz cycle frequency (33-msec pulse period and 10-msec pulse width including a 0.2-msec pulse spike; ref. 4). Temperature distributions were calculated with one-dimensional finite difference models. The calculations show that that the 0.2-msec pulse spike can cause an additional 40 C temperature fluctuation with an interaction depth of 0.08 mm near the specimen surface region. This temperature swing will be superimposed onto the temperature swing of 80 C that is induced by the 10-msec laser pulse near the 0.53-mm-deep surface interaction region.

Zhu, Dong-Ming↗

2.0 um Wavelength Injection Seed Semiconductor Laser for Lidar Transmitter for Global-Scale Measurements of CO2

Many of the high accuracy Earth science survey missions are planned to use laser-based remote sensing instruments. The 2-μm laser wavelength is of particular interest due to the presence of many CO2 and H20 absorption lines in its vicinity1. Transmitter architectures are typically composed of an optically pumped, frequency-stable, solid-state seed laser and a high-power optical amplifier.2, 3 Taking advantage of the reliability and relative simplicity of semiconductor lasers, this architecture can substantially improve by replacing the solid-state light source with semiconductor lasers of comparable performance. This approach will greatly improve the system reliability, and will simplify instrument integration and space qualification. There are currently very limited semiconductor lasers operating in the 2-m range with performance satisfactory enough for use as an injection seed in a laser absorption spectrometer. Optimally, seed lasers producing greater than 50 mW of continuous-wave (CW), with frequency jitter of less than 1 MHz are desired to reliably resolve the CO2 absorption lines near 2-µm. In this paper, we report the demonstration of high-power, single-longitudinal-mode laterally coupled distributed feedback (LC-DFB) lasers at 2.05 µm wavelength. We measured more than 80 mW of CW power at -10 ºC for devices with a 4-µm-wide ridge and 2-mm-long cavity.

Fradet, Mathieu↗

Laser-Induced Spectrochemical Assay for Uranium Enrichment (LISA-UE)

Uranium hexafluoride (UF6) is the uranium compound typically involved in uranium enrichment process. As the first line of defense against nuclear proliferation, accurate determinations of the uranium enrichment ratio in UF6 are critical for materials verification, accounting and safeguards. Shipping gaseous UF6 samples off-site for analysis with mass spectrometry is cumbersome and costly, and results are not available for some time (months). In-field UF6 enrichment assay has the potential to substantially reduce the time, logistics and expense of sample handling. At present, COMPUCEA is the only accepted method for UF6 enrichment assay in the field. Laser-Induced Spectrochemical Assay for Uranium Enrichment (LISA-UE) is an all-optical (based on laser induced plasma emission) analytical technique intended for fieldable, accurate, precise and rapid UF6 enrichment assay. In its operation, laser induced plasma is created directly in the gaseous UF6 sample. Because different U isotopes emit at slightly different wavelengths, the isotopic information of the UF6 sample is inherently encoded in the atomic emission from the plasma. Isotopic emissions from 235U and 238U are measured simultaneously, which eliminate correlated noise from the laser induced plasma. Isotopic information of the UF6 sample can be extracted from the acquired spectrum with theoretical multi-variable non-linear spectral fitting. To date, advances made by the LISA-UE research team include optimization of the spectral window for direct gaseous UF6 enrichment assay with laser induced plasma, development of data reduction algorithms, and demonstrations of the LISA-UE technique with gaseous UF6 samples. In this presentation, the technical aspect of LISA-UE will be overviewed, the data reduction algorithm will be described, and performance of the technique will be discussed.

Chan, George↗

Sub-Nanosecond, Room-Temperature, Mid-IR Fe:ZnSe Gain-Switched Laser: Experimental Characterization and Modeling

We present the modeling and experimental characterization of a room-temperature, sub-nanosecond, gain-switched (GS) Fe:ZnSe laser operating at 4.4–4.8 μm. As pump sources, we used a 2.79 µm Q-switched Cr:Er:YSGG laser with a pulse duration of 52 ns and the 2.98 μm idler of a Nd:YAG pumped KTA-OPO system with a pulse duration of 9 ns. The shortest pulse durations were measured to be 1.4 ns and 0.7 ns under excitation by the Cr:Er:YSGG laser and KTA-OPO system, respectively. The developed Fe:ZnSe laser model showed good agreement with the experimental results. Optimization of the laser parameters based on model simulations suggests that an Fe:ZnSe microchip laser configuration could be achieved with a pulse duration of ~250 ps and an efficiency of ~20%.

Ghimire, Saugat↗

Laser action in chromium-activated forsterite for near infrared excitation

This paper reports on laser action in chromium-doped forsterite (Cr:Mg2SiO4) for 1064-nm excitation of the crystal's double-hump absorption band spanning the 850-1200-nm wavelength range. The cavity arrangement used for obtaining laser action in Cr:Mg2SiO2 was similar to that described by Petricevic et al. (1988). The fundamental and second harmonic emissions from a Q-switched Nd:YAG laser operating at a 10-Hz repetition rate were used for excitation of the NIR and visible bands, respectively. Pulsed laser action was readily observed for both the 1064-nm and 532-nm pumping at or above the respective thresholds. The laser parameters of the 532-nm and 1064-nm excitations were similar, indicating that the IR band is responsible for laser action for both excitations.

Petricevic, V.↗

Summary Abstract: Vibrations of Ammonia on the Cu (100) Surface

Recently, the TR frequencies for NH3 molecularly adsorbed on Cu(100) have been measured by infrared laser-induced photodesorption using a tunable laser operating in the group frequency range. Additionally, photodesorption, photo-fragmentation, and photoionization has been observed using a CO2 laser in the 10 microns range. In this contribution we report on work in progress where we use quantum chemical methods to analyze the shifts in the NH, frequencies relative to the gas phase upon chemisorption. We also compute the Cu- N stretch vibration, which has been observed experimentally,and the change in the IR intensities associated with chemisorption; this change is insufficient by itself to explain the increased photoionization efficiency observed.

Pettersson, Lars G. M.↗

Methane concentration and isotopic composition measurements with a mid-infrared quantum-cascade laser

A quantum-cascade laser operating at a wavelength of 8.1 micrometers was used for high-sensitivity absorption spectroscopy of methane (CH4). The laser frequency was continuously scanned with current over more than 3 cm-1, and absorption spectra of the CH4 nu 4 P branch were recorded. The measured laser linewidth was 50 MHz. A CH4 concentration of 15.6 parts in 10(6) ( ppm) in 50 Torr of air was measured in a 43-cm path length with +/- 0.5-ppm accuracy when the signal was averaged over 400 scans. The minimum detectable absorption in such direct absorption measurements is estimated to be 1.1 x 10(-4). The content of 13CH4 and CH3D species in a CH4 sample was determined.

Non-NASA Center↗