Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “large detector systems for particle physics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Development of a bright MeV photon source with compound parabolic concentrator targets on the National Ignition Facility Advanced Radiographic Capability (NIF-ARC) laser

Compound parabolic concentrator (CPC) targets are utilized at the National Ignition Facility Advanced Radiographic Capability (NIF-ARC) laser to enhance the acceleration of electrons and production of high energy photons, for laser durations of 10 ps and energies up to 2.4 kJ. A large enhancement of mean electron energy (>2 ×) and photon brightness (>10×) is found with CPC targets compared to flat targets. Using multiple diagnostic techniques at different spatial locations and scaling by gold activation spatial data, photon spectra are characterized for E photon = 0.5-30 MeV. Beam width and pointing variations are given. The efficient production of MeV photons at I laser ≈ 2 x 10 18 W/cm 2 with CPCs is observed, with doses of >10 rad in air at 1 m for E photon > 0.5 MeV; these exceed those previously reported with laser-driven sources. Using this source, sub-mm resolution radiographs are generated through large areal density radiograph objects. Hence these results are promising for the development of bright MeV x-ray and particle sources on Petawatt class laser systems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Detection of DNA Damage by Space Radiation in Human Fibroblasts Flown on the International Space Station

Space radiation consists of energetic charged particles of varying charges and energies. Exposure of astronauts to space radiation on future long duration missions to Mars, or missions back to the Moon, is expected to result in deleterious consequences such as cancer and comprised central nervous system (CNS) functions. Space radiation can also cause mutation in microorganisms, and potentially influence the evolution of life in space. Measurement of the space radiation environment has been conducted since the very beginning of the space program. Compared to the quantification of the space radiation environment using physical detectors, reports on the direct measurement of biological consequences of space radiation exposure have been limited, due primarily to the low dose and low dose rate nature of the environment. Most of the biological assays fail to detect the radiation effects at acute doses that are lower than 5 centiSieverts. In a recent study, we flew cultured confluent human fibroblasts in mostly G1 phase of the cell cycle to the International Space Station (ISS). The cells were fixed in space after arriving on the ISS for 3 and 14 days, respectively. The fixed cells were later returned to the ground and subsequently stained with the gamma-H2AX (Histone family, member X) antibody that are commonly used as a marker for DNA damage, particularly DNA double strand breaks, induced by both low-and high-linear energy transfer radiation. In our present study, the gamma-H2AX (Histone family, member X) foci were captured with a laser confocal microscope. To confirm that some large track-like foci were from space radiation exposure, we also exposed, on the ground, the same type of cells to both low-and high-linear energy transfer protons, and high-linear energy transfer Fe ions. In addition, we exposed the cells to low dose rate gamma rays, in order to rule out the possibility that the large track-like foci can be induced by chronic low-linear energy transfer radiation.

Lu, Tao↗

Demonstration of neutron time-of-flight diffraction with an event-mode imaging detector

Neutron diffraction beamlines have traditionally relied on deploying large detector arrays of 3 He tubes or neutron-sensitive scintillators coupled with photomultipliers to efficiently probe crystallographic and microstructure information of a given material. Given the large upfront cost of custom-made data acquisition systems and the recent scarcity of 3 He, new diffraction beamlines or upgrades to existing ones demand innovative approaches. This paper introduces a novel Timepix3-based event-mode imaging neutron diffraction detector system as well as first results of a silicon powder diffraction measurement made at the HIPPO neutron powder diffractometer at the Los Alamos Neutron Science Center. Notably, these initial measurements were conducted simultaneously with the 3 He array on HIPPO, enabling direct comparison. Data reduction for this type of data was implemented in the MAUD code, enabling Rietveld analysis. Results from the Timepix3-based setup and HIPPO were benchmarked against McStas simulations, showing good agreement for peak resolution. With further development, systems such as the one presented here may substantially reduce the cost of detector systems for new neutron instrumentation as well as for upgrades of existing beamlines.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cloud-to-Ground Lightning Estimates Derived from SSMI Microwave Remote Sensing and NLDN

Lightning observations are collected using ground-based and satellite-based sensors. The National Lightning Detection Network (NLDN) in the United States uses multiple ground sensors to triangulate the electromagnetic signals created when lightning strikes the Earth's surface. Satellite-based lightning observations have been made from 1998 to present using the Lightning Imaging Sensor (LIS) on the NASA Tropical Rainfall Measuring Mission (TRMM) satellite, and from 1995 to 2000 using the Optical Transient Detector (OTD) on the Microlab-1 satellite. Both LIS and OTD are staring imagers that detect lightning as momentary changes in an optical scene. Passive microwave remote sensing (85 and 37 GHz brightness temperatures) from the TRMM Microwave Imager (TMI) has also been used to quantify characteristics of thunderstorms related to lightning. Each lightning detection system has fundamental limitations. TRMM satellite coverage is limited to the tropics and subtropics between 38 deg N and 38 deg S, so lightning at the higher latitudes of the northern and southern hemispheres is not observed. The detection efficiency of NLDN sensors exceeds 95%, but the sensors are only located in the USA. Even if data from other ground-based lightning sensors (World Wide Lightning Location Network, the European Cooperation for Lightning Detection, and Canadian Lightning Detection Network) were combined with TRMM and NLDN, there would be enormous spatial gaps in present-day coverage of lightning. In addition, a globally-complete time history of observed lightning activity is currently not available either, with network coverage and detection efficiencies varying through the years. Previous research using the TRMM LIS and Microwave Imager (TMI) showed that there is a statistically significant correlation between lightning flash rates and passive microwave brightness temperatures. The physical basis for this correlation emerges because lightning in a thunderstorm occurs where ice is first present in the cloud and electric charge separation occurs. These ice particles efficiently scatter the microwave radiation at the 85 and 37 GHz frequencies, thus leading to large brightness temperature depressions. Lightning flash rate is related to the total amount of ice passing through the convective updraft regions of thunderstorms. Confirmation of this relationship using TRMM LIS and TMI data, however, remains constrained to TRMM observational limits of the tropics and subtropics. Satellites from the Defense Meteorology Satellite Program (DMSP) have global coverage and are equipped with passive microwave imagers that, like TMI, observe brightness temperatures at 85 and 37 GHz. Unlike the TRMM satellite, however, DMSP satellites do not have a lightning sensor, and the DMSP microwave data has never been used to derive global lightning. In this presentation, a relationship between DMSP Special Sensor Microwave Imager (SSMI) data and ground-based cloud-to-ground (CG) lightning data from NLDN is investigated to derive a spatially complete time history of CG lightning for the USA study area. This relationship is analogous to the established using TRMM LIS and TMI data. NLDN has the most spatially and temporally complete CG lightning data for the USA, and therefore provides the best opportunity to find geospatially coincident observations with SSMI sensors. The strongest thunderstorms generally have minimum 85 GHz Polarized Corrected brightness Temperatures (PCT) less than 150 K. Archived radar data was used to resolve the spatial extent of the individual storms. NLDN data for that storm spatial extent defined by radar data was used to calculate the CG flash rate for the storm. Similar to results using TRMM sensors, a linear model best explained the relationship between storm-specific CG flash rates and minimum 85 GHz PCT. However, the results in this study apply only to CG lightning. To extend the results to weaker storms, the probability of CG lightning (instead of the flash rate) was calculated for storms having 85 GHz PCT greater than 150 K. NLDN data was used to determine if a CG strike occurred for a storm. This probability of CG lightning was plotted as a function of minimum 85 GHz PCT and minimum 37 GHz PCT. These probabilities were used in conjunction with the linear model to estimate the CG flash rate for weaker storms with minimum 85 GHz PCTs greater than 150 K. Results from the investigation of CG lightning and passive microwave radiation signals agree with the previous research investigating total lightning and brightness temperature. Future work will take the established relationships and apply them to the decades of available DMSP data for the USA to derive a map of CG lightning flash rates. Validation of this method and uncertainty analysis will be done by comparing the derived maps of CG lightning flash rates against existing NLDN maps of CG lightning flash rates.

Winesett, Thomas↗

Measurement of flow coefficients in high-multiplicity 𝑝 + Au, 𝑑 + Au, and 3 He + Au collisions at $\sqrt{s_{NN}}$ = 200 GeV

Flow coefficients (𝑣 2 and 𝑣 3 ) are measured in high-multiplicity 𝑝 + Au, 𝑑 + Au, and 3 He + Au collisions at a center-of-mass energy of $\sqrt{s_{NN}}$ = 200 GeV using the STAR detector. The measurements utilize two-particle correlations with a pseudorapidity requirement of |𝜂| < 0.9 and a pair gap of |Δ⁢𝜂| > 1.0. The primary focus is on analysis methods, particularly the subtraction of nonflow contributions. Four established nonflow subtraction methods are applied to determine 𝑣 𝑛 , validated using the HIJING event generator. 𝑣 𝑛 values are compared across the three collision systems at similar multiplicities; this comparison cancels the final-state effects and isolates the impact of initial geometry. While 𝑣 2 values show differences among these collision systems, 𝑣 3 values are largely similar, consistent with expectations of subnucleon fluctuations in the initial geometry. The ordering of 𝑣 𝑛 differs quantitatively from previous measurements using two-particle correlations with a larger rapidity gap, which, according to model calculations, can be partially attributed to the effects of longitudinal flow decorrelations. As a result, the prospects for future measurements to improve our understanding of flow decorrelation and subnucleonic fluctuations are also discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Study of the doubly charmed tetraquark $\mathrm{T}$ $^+_{cc}$

Quantum chromodynamics, the theory of the strong force, describes interactions of coloured quarks and gluons and the formation of hadronic matter. Conventional hadronic matter consists of baryons and mesons made of three quarks and quark-antiquark pairs, respectively. Particles with an alternative quark content are known as exotic states. Here a study is reported of an exotic narrow state in the D 0 D 0 π + mass spectrum just below the D *+ D 0 mass threshold produced in proton-proton collisions collected with the LHCb detector at the Large Hadron Collider. The state is consistent with the ground isoscalar T$^{+}_{cc}$ tetraquark with a quark content of cc$\bar{u}\bar{d}$ and spin-parity quantum numbers J P = 1 + . Study of the DD mass spectra disfavours interpretation of the resonance as the isovector state. The decay structure via intermediate off-shell D *+ mesons is consistent with the observed D 0 π+ mass distribution. To analyse the mass of the resonance and its coupling to the D*D system, a dedicated model is developed under the assumption of an isoscalar axial-vector T$^{+}_{cc}$ state decaying to the D*D channel. Using this model, resonance parameters including the pole position, scattering length, effective range and compositeness are determined to reveal important information about the nature of the T$^{+}_{cc}$ state. In addition, an unexpected dependence of the production rate on track multiplicity is observed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Potential Constraints to Neutrino-Nucleus Interactions Based on Electron Scattering Data

A thorough understanding of neutrino-nucleus interactions physics is crucial to achieving precision goals in broader neutrino physics programs. The complexity of nuclei comprising the detectors and limited understanding of their weak response constitutes one of the biggest systematic uncertainties in neutrino experiments - both at intermediate energies affecting the short- and long-baseline neutrino programs as well as at lower energies affecting coherent scattering neutrino programs. While electron and neutrino interactions are different at the primary vertex, many underlying relevant physical processes in the nucleus are the same in both cases, and electron scattering data collected with precisely controlled kinematics, large statistics and high precision allows one to constrain nuclear properties and specific interaction processes. To this end, electron-nucleus scattering experiments provide vital complementary information to test, assess and validate different nuclear models and event generators intended to be used in neutrino experiments. In fact, for many decades, the study of electron scattering off a nucleus has been used as a tool to probe the properties of that nucleus and its electromagnetic response. While previously existing electron scattering data provide important information, new and proposed measurements are tied closely to what is required for the neutrino program in terms of expanding kinematic reach, the addition of relevant nuclei and information on the final states hadronic system.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A LArTPC with Vertical Drift for the DUNE Far Detector

The Far Detector of the Deep Underground Neutrino Experiment (DUNE) will be a large LArdetector located at a baseline of 1300 kilometers, 1.5 km deep underground. It is planned to bemade up of four modules, each with a total mass of 17 kt of LAr, at least the first two of which willconsist in Liquid Argon Time Projection Chambers (LArTPCs). To prove the feasibility of theLArTPC technology at the kiloton scale, the ProtoDUNE Single and Dual-Phase detectors wereconstructed and operated at the CERN Neutrino facility.This document describes the Vertical Drift detector concept, which is proposed to instrument thesecond DUNE module. It consists of a TPC where the electrons drift vertically, with a cathodesuspended at mid-height, towards anodes placed at the bottom and top of the detector. The anodeswould be made out of printed PCBs instead of wires, and the new disposition would allow the topreadout electronics to be accessible during the lifetime of the experiment. An enhanced photo-detection system is also proposed, with the photo-sensors placed on the cryostat walls and thecathode, but posing a challenge in terms of power and signal transmission. Studies are ongoingboth to overcome the technical challenges of this new design and to finalize the concept.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Physics of Hard Spheres Experiment: Significant and Quantitative Findings Made

Direct examination of atomic interactions is difficult. One powerful approach to visualizing atomic interactions is to study near-index-matched colloidal dispersions of microscopic plastic spheres, which can be probed by visible light. Such spheres interact through hydrodynamic and Brownian forces, but they feel no direct force before an infinite repulsion at contact. Through the microgravity flight of the Physics of Hard Spheres Experiment (PHaSE), researchers have sought a more complete understanding of the entropically driven disorder-order transition in hard-sphere colloidal dispersions. The experiment was conceived by Professors Paul M. Chaikin and William B. Russel of Princeton University. Microgravity was required because, on Earth, index-matched colloidal dispersions often cannot be density matched, resulting in significant settling over the crystallization period. This settling makes them a poor model of the equilibrium atomic system, where the effect of gravity is truly negligible. For this purpose, a customized light-scattering instrument was designed, built, and flown by the NASA Glenn Research Center at Lewis Field on the space shuttle (shuttle missions STS 83 and STS 94). This instrument performed both static and dynamic light scattering, with sample oscillation for determining rheological properties. Scattered light from a 532- nm laser was recorded either by a 10-bit charge-coupled discharge (CCD) camera from a concentric screen covering angles of 0 to 60 or by sensitive avalanche photodiode detectors, which convert the photons into binary data from which two correlators compute autocorrelation functions. The sample cell was driven by a direct-current servomotor to allow sinusoidal oscillation for the measurement of rheological properties. Significant microgravity research findings include the observation of beautiful dendritic crystals, the crystallization of a "glassy phase" sample in microgravity that did not crystallize for over 1 year in 1g (Earth's gravity), and the emergence of face-centered-cubic (FCC) crystals late in the coarsening process (as small crystallites lost particles to the slow ripening of large crystallites). Significant quantitative findings from the microgravity experiments have been developed describing complex interactions among crystallites during the growth process, as concentration fields overlap in the surrounding disordered phase. Time-resolved Bragg scattering under microgravity captures one effect of these interactions quite conclusively for the sample at a volume fraction of 0.528. From the earliest time until the sample is almost fully crystalline, the size and overall crystallinity grow monotonically, but the number of crystallites per unit volume (number density) falls. Apparently nucleation is slower than the loss of crystallites because of the transfer of particles from small to large crystals. Thus, coarsening occurs simultaneously with growth, rather than following the completion of nucleation and growth as is generally assumed. In the same sample, an interesting signature appears in the apparent number density of crystallites and the volume fraction within the crystallites shortly before full crystallinity is reached. A brief upturn in both indicates the creation of more domains of the size of the average crystallite simultaneous with the compression of the crystallites. Only the emergence of dendritic arms offers a reasonable explanation. The arms would be "seen" by the light scattering as separate domains whose smaller radii of curvature would compress the interior phase. In fiscal year 1999, numerous papers, a doctoral dissertation, and the PHaSE final report were produced. Although this flight project has been completed, plans are in place for a follow-on colloid experiment by Chaikin and Russel that employs a light microscope within Glenn's Fluids and Combustion Facility on the International Space Station. PHaSE is providing us with a deeper understanding of the nure of phase transitions. The knowledge derived has added to the understanding of condensed matter. In addition, the burgeoning study of the dynamics of colloidal self-assembly may lead to the development of a range of photonic materials that control the desirable properties of light. Thus, applications of ordered colloidal structures include not only ultrastructure ceramics, but also photonic crystals and photothermal nanosecond light-switching devices. Industries dealing with semiconductors, electro-optics, ceramics, and composites stand to benefit from such advancements.

Doherty, Michael P.↗

Convolutional Neural Networks for the CHIPS Neutrino Detector R&D Project.

The CHerenkov detectors In mine PitS (Chips) neutrino detector R&D project aims to develop novel strategies and technologies for very large yet ‘cheap as chips’ water Cherenkov neutrino detectors. Via deployment in a body of water, use of commercially available components, and instrumentation coverage optimisation for the study of exclusively accelerator beam neutrinos, Chips will enable megaton scale detectors to become a reality at the cost of $200k-$300k per kt of sensitive mass. During the summer of 2019 a prototype Chips detector, Chips-5, was deployed into the Wentworth 2W disused mine pit in northern Minnesota, 7 mrad off the NuMI beam axis. A novel data acquisition system was introduced using cheap single-board computers and open-source software. This work presents a novel approach to water Cherenkov neutrino detector event reconstruction and classification. Three forms of a Convolutional Neural Network, a type of deep learning algorithm, have been trained to reject cosmic muon events, classify beam events, and estimate neutrino energies, all using only the raw detector event as input. When evaluated on the expected distribution of Chips-5 events, this new approach is shown to be robust and explainable as well as providing a significant performance increase over the standard likelihood-based reconstruction and simple neural network classification. Promisingly, the performance presented here is comparable to the more complex (and expensive) neutrino oscillation experiments within the field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The continuous readout stream of the MicroBooNE liquid argon time projection chamber for detection of supernova burst neutrinos

The MicroBooNE continuous readout stream is a parallel readout of the MicroBooNE liquid argon time projection chamber (LArTPC) which enables detection of non-beam events such as those from a supernova neutrino burst. The low energies of the supernova neutrinos and the intense cosmic-ray background flux due to the near-surface detector location makes triggering on these events very challenging. Instead, MicroBooNE relies on a delayed trigger generated by SNEWS (the Supernova Early Warning System) for detecting supernova neutrinos. The continuous readout of the LArTPC generates large data volumes, and requires the use of real-time compression algorithms (zero suppression and Huffman compression) implemented in an FPGA (field-programmable gate array) in the readout electronics. In this paper we present the results of the optimization of the data reduction algorithms, and their operational performance. To demonstrate the capability of the continuous stream to detect low-energy electrons, a sample of Michel electrons from stopping cosmic-ray muons is reconstructed and compared to a similar sample from the lossless triggered readout stream.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lycoris - A large-area, high resolution beam telescope

We note that a high-resolution beam telescope is one of the most important and demanding infrastructure components at any test beam facility. Its main purpose is to provide reference particle tracks from the incoming test beam particles to the test beam users, which allows measurement of the performance of the device-under-test (DUT). LYCORIS, a six-plane compact beam telescope with an active area of ~ 10 x 10 cm 2 (extensible to 10 x 20 cm 2 ) was installed at the DESY II Test Beam Facility in 2019, to provide a precise momentum measurement in a 1 T solenoid magnet or to provide tracking over a large area. The overall design of Lycoris will be described as well as the performance of the chosen silicon sensor. The 25 μm pitch micro-strip sensor used for Lycoris was originally designed for the SiD detector concept for the International Linear Collider. It adopts a second metallization layer to route signals from strips to the bump-bonded KPiX ASIC and uses a wire-bonded flex cable for the connection to the DAQ and the power supply system. This arrangement eliminates the need for a dedicated hybrid PCB. Its performance was tested for the first time in this project. The system has been evaluated at the DESY II Test Beam Facility in several test-beam campaigns and has demonstrated an average single-point resolution of 7.07 μm.

47 OTHER INSTRUMENTATION↗

Measurement of the azimuthal anisotropy of charged particles in $\sqrt{s_{\mathrm{NN}}}=5.36$ TeV $^{16}$O$+^{16}$O and $^{20}$Ne$+^{20}$Ne collisions with the ATLAS detector

This paper presents the first measurements of the azimuthal anisotropy coefficients $v_{n}$, which quantify the $n^{\mathrm{th}}$-order Fourier modulation of charged-particle azimuthal distributions, for $n=2$-4 in $\sqrt{s_{\mathrm{NN}}}=5.36$ TeV $\mathrm{^{16}O}+\mathrm{^{16}O}$ and $\mathrm{^{20}Ne}+\mathrm{^{20}Ne}$ collisions recorded with the ATLAS detector at the Large Hadron Collider in 2025. The $v_{n}$ coefficients are measured as a function of transverse momentum ($p_{\mathrm{T}}$), collision centrality, and event multiplicity. They are extracted using two complementary methods: two-particle correlations with a template-fit subtraction of short-range non-flow contributions, and four-particle subevent cumulants, which intrinsically suppress non-flow effects and provide sensitivity to flow fluctuations. The results show a clear hierarchy $v_{2} > v_{3} > v_{4}$ and a non-monotonic dependence on $p_{\mathrm{T}}$, reaching a maximum around 2 GeV, consistent with trends observed in heavy-ion collisions. Detailed comparisons between the two collision systems reveal an enhanced $v_{2}$ in central $\mathrm{^{20}Ne}+\mathrm{^{20}Ne}$ collisions, consistent with theory expectations based on the predicted prolate deformation of neon nuclei, in contrast to the slightly tetrahedral structure predicted for oxygen. The four-particle cumulant results highlight strong event-by-event fluctuations and provide the greatest sensitivity to nuclear shape effects. These measurements can place new constraints on the initial geometry and the hydrodynamic response in light-ion collisions, offering valuable input for models of nuclear structure.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SCALE 6.3 Validation: Radiation Shielding

Safe and reliable use of scientific and engineering computer codes requires validation for the types of applications in which they will be used. An example in the nuclear reactor engineering and licensing field is radiation transport employed in shielding analyses. The validity of computer codes for shielding applications is demonstrated in this report for SCALE version 6.3.0. Representative benchmarks corresponding to shielding analyses are selected for the validation study. Typical measurement results analyzed from these benchmarks include neutron fluxes, detector count rates, detector energy response functions, neutron and gamma dose rates, neutron activation rates and activities, neutron leakage fluxes, and skyshine dose rates. Thousands of points of comparison between measurement and calculation are presented in this work. Other than rare outliers typically explained by either a lack of information or large uncertainties in the experiment conditions, material, or dimensions, the Monaco with Automated Variance Reduction using Importance Calculations (MAVRIC) radiation transport computer code with built-in variance reduction methods distributed with the SCALE computer code system agrees well with the measurement results. In selected benchmarks, MAVRIC is also compared to Monte Carlo N- Particle® (MCNP® ) 1 calculations. Both computer codes generally agree well within the estimated uncertainties. With the release of SCALE 6.3.0, Shift was integrated as an alternative transport solver in MAVRIC, denoted MAVRIC-Shift. Although the traditional MAVRIC using Monaco was used primarily in this validation study, many results have also been generated using MAVRIC-Shift. Agreement between MAVRIC-Monaco and MAVRIC-Shift is generally very good. The benchmarks presented in this report were obtained from reliable sources such as the International Criticality Safety Benchmark Evaluation Project Handbook, the Shielding Integral Benchmark Archive & Database, and other shielding validation work found in the literature. Additional datapoints and benchmarks will be added to future versions of this report to expand the shielding validation suite.

61 RADIATION PROTECTION AND DOSIMETRY↗

Qualification study of SiPMs on a large scale for the CMVD Experiment

A Cosmic Muon Veto (CMV) detector using extruded plastic scintillators is being designed around the mini-Iron Calorimeter (mini-ICAL) detector at the transit campus of the India based Neutrino Observatory, Madurai for the feasibility study of shallow depth underground experiments. The scintillation signals that are produced in the plastic due to muon trajectories are absorbed by wavelength shifting (WLS) fibres. The WLS fibres re-emit photons of longer wavelengths and propagate those to silicon photo-multipliers (SiPMs). The SiPMs detect these photons, producing electronic signals. The CMV detector will use more than 700 scintillators to cover the mini-ICAL detector and will require around 3000 SiPMs. The design goal for the cosmic muon veto efficiency of the CMV is >99.99%. Hence, every SiPM used in the detector needs to be tested and characterised to satisfy the design goal of CMV. A mass testing system was developed for the measurement of gain and choice of the overvoltage ($V_{ov}$) of each SiPMs using an LED driver. The $V_{ov}$ is obtained by studying the noise rate, the gain of the SiPM. This paper describes the experimental setup used to test the SiPMs characteristics along with detailed studies of those characteristics as a function of temperature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of Charged Current Inclusive $\bar{V}_\mu$ Interactions and 2p2h Contribution Using the NOvA Near Detector

More precise measurements of the scattering of antineutrinos on nuclei in the few GeV region of incident energy, $E_{\nu}$, can reveal new aspects of $v/\bar{v}$ interactions and of nuclear structure, while providing information crucial to continued progress by neutrino oscillation experiments. This Thesis reports an investigation of charged current $\bar{v}_\mu$ interactions in the predominantly hydrocarbon medium of the NOvA Near Detector. The data are obtained with the detector exposed to a narrow-band $\bar{v}$ µ beam with spectral peak at E ν = 2.0 GeV, for a total accumulated exposure of 12.5×10$^{20}$ protons-on-target. The analysis expresses results in terms of three-momentum transfer,|$\vec{q}$| and available hadronic energy, $E$ avail . These variables approximate (q 0 , |$\vec{q}$|), the variables used in theoretical treatments of lepton scattering on multi-nucleon systems such as in 2-particle-2-hole (2p2h) processes. This Thesis delivers two core measurements: Firstly, the double-dierential cross section $d^2σ/d|\vec{q} |dE_{avail}$ for inclusive CC $\bar{v}_\mu$ interactions in the NOvA detector medium is obtained. The cross section has a roughly gaussian shape in its projection onto |$\vec{q}$|, while being largely concentrated at values of $E$ avail below 100 MeV. The single diferential cross sections dσ/d|$\vec{q}$| and dσ/dE avail are also obtained, and are compared to predictions based on the GENIE v3.0.6 neutrino generator augmented with four different implementations of 2p2h reactions. Secondly, the contribution of 2p2h reactions to the CC inclusive scattering sample is determined. Its presence is characterized in terms of double-differential and single-differential cross sections. The latter 2p2h distributions are compared to predictions from two experimental data-tune models and from two theory-based models, namely the SuSAv2 model and the Valencia model. Both of the theoretical models underpredict the measured cross-section strength and predict a shape for dσ/d|$\vec{q}$| that is flatter than the measured shape. Thus, this Thesis provides new information about CC antineutrino-nucleus scattering in the vicinity of Eν ~ 2 GeV, and it highlights improvements that are needed in theoretical treatments of 2p2h reactions.

43 PARTICLE ACCELERATORS↗

Development of an Ultrahigh-bandwidth Phase Contrast Imaging System for detection of electron scale turbulence and Gigahertz Radio-Frequency Waves

The study of waves and turbulence is vital to the development of future reactor-grade plasma devices developed in the quest for fusion energy. These fluctuations are responsible for moving heat and particles across the magnetic field, and a predictive understanding of them is needed to achieve the density and temperature required to sustain a plasma fusion reaction. While many techniques have been developed for measuring waves and fluctuations, every measurement method has limitations. There are relatively few techniques for measuring very high frequency fluctuations, such as radio frequency waves injected to heat the plasma, unstable waves driven by suprathermal particles, or short wavelength electrostatic waves driven by electron temperature or density gradients. The present project builds upon the proven phase contrast imaging (PCI) technique to extend the response of the diagnostic by orders of magnitude in frequency and almost a factor of ten in spatial resolution. PCI provides a measurement of electron density based on small angle scattering of a CO-2 laser beam by using optical techniques to render a phase shift as an intensity change on a detector. Due to the telecommunications revolution, technological development by manufacturers has focused on components in the near -infrared, so that high- quality lasers and detectors at 1.55 µm are readily available. Shifting PCI design to a new, shorter wavelength has numerous advantages and challenges. Similar detector performance is available with room-temperature arrays with GHz bandwidth, while the detector arrays for 10.6 µm required liquid nitrogen cooling and were therefore limited to a bandwidth of about 1 MHz. Shifting to a shorter wavelength reduces the angle at which the laser beam scatters off of plasma waves, allowing more such scattered components to pass through the aperture of the vacuum vessel port and be collected by the PCI, which increases the spatial resolution. Concomitant with these benefits, various questions of performance arise. At shorter laser wave- length, the sensitivity to mirror and lens quality is increased, the contribution of the laser to the overall system noise is increased, and the sensitivity to vibrations is increased. The custom optical components at the heart of the PCI technique were required to be properly scaled for the shorter wavelength, so fabrication technologies needed to be explored. This project was designed to show that a low noise, high response PCI system at 1.55 µm could be constructed and operated, and then to quantify potential issues to allow extrapolation to a full-size production system providing physics measurements on a large plasma device. The first stage, producing the custom optical component called a Phase Plate, was successfully achieved using two methods. First, an easily reproduced masking and coating technique was able to produce good phase plates with the required parameters. Second, a nanofabrication technique was found to produce extremely high quality phase plates at a competitive price. The PCI constructed with the new phase plates and 1.55 µm laser was found to provide excellent wavelength measurements with the theoretically expected response. The sensitivity to optical surface quality was found to be in line with previous measurements at 10.6 µm. The observed signal-to-noise ratio was similar to the theoretically expected value. The effect of vibrations on PCI was studied with the first measurement of the effect of beam motion on PCI response and comparison to theory, allowing for a quantitative prediction of the effect of vibrations on a production PCI system and the requirements for improved beam stabilization. PCI is an extremely cost-effective method to provide a low noise, absolutely calibrated measurement of plasma fluctuations across a wide spatial scale. This project has shown that a 1.55 µm PCI using modern techniques and components is less expensive than the 10.6 µm PCI of a few years ago, with the largest savings in phase plate fabrication and the infrared detector array.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Correlated $\ n-γ$ angular distributions from the $\ Q$ = 4.4398 MeV 12 C ($\ n, n' γ$) reaction for incident neutron energies from 6.5 MeV to 16.5 MeV

Neutron scattering cross sections and angular distributions represent one of the most glaring sources of uncertainty in calculations of nuclear systems. Even simple nuclei like 12 C show indications of errors in nuclear databases for scattering reactions. Measurements of inelastic neutron scattering have historically measured either the scattered neutrons or the nuclear deexcitation $\ γ$ emission. Only a very small number of experiments attempted correlated measurements of both the neutron and $\ γ$ data simultaneously, even though these $\ n-γ$ correlations could be essential for understanding particle transport in nuclear systems. In this work we describe a measurement of the $\ n, γ$, and correlated $\ n-γ$ angular distributions from the $\ Q$ = 4.4398 MeV 12 C ($\ n, n'γ$) reaction in a single experiment using an EJ-309 liquid scintillator detector array with wide angular coverage, and with a continuous incident neutron energy range from 6.5 to 16.5 MeV. We also provide a thorough covariance description of these results, including normalization of the probability distribution. While the measured n distributions agree well with the relatively large number of available literature measurements, there are comparatively very few measurements of the γ distributions from this reaction. However, our data support the presence of a nonzero α 4 Legendre polynomial component of the γ angular distribution suggested in past measurements, which is currently not incorporated in the ENDF/B-VIII.0 library despite the use of these same literature data for evaluation of the 12 C ($\ n, n'γ$) cross section. The correlated $\ n-γ$ distribution measurements are limited to three measurements at incident neutron energies near 14 MeV. Our results do not generally agree with any of these literature measurements. We observe clear indications of significant changes in the $\ n$ distribution for specific $\ γ$-detection angles and vice versa especially near thresholds for other reaction channels, which shows the potential for significant bias in experiments that, for example, tag on inelastic scattering using a single or small number of $\ γ$ -detection angles and could impact particle transport calculations.

6 ≤ A ≤ 19↗