Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “kWh”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Energy requirements of the switchable polarity solvent forward osmosis (SPS-FO) water purification process

A model was developed to estimate the process energy requirements of a switchable polarity solvent forward osmosis (SPS FO) system for water purification from aqueous NaCl feed solution concentrations ranging from 0.5 to 4.0 molal at an operational scale of 480 m3/day (feed stream). The model indicates recovering approximately 90% of the water from a feed solution with NaCl concentration similar to seawater using SPS FO would have total equivalent energy requirements between 2.4 and 4.3 kWh per m 3 of purified water product. The process is predicted to be competitive with current costs for disposal/treatment of produced water from oil and gas drilling operations. As a result, once scaled up the SPS FO process may be a thermally driven desalination process that can compete with the cost of seawater reverse osmosis.

15 GEOTHERMAL ENERGY↗

Osmotically assisted reverse osmosis for high salinity brine treatment

Here, this work evaluates a novel osmotically assisted reverse osmosis (OARO) process for dewatering high salinity brines using readily available membranes and equipment. While traditional reverse osmosis processes are limited to treating brines with osmotic pressures below the membrane burst pressure, in OARO, the osmotic pressure difference across a membrane is reduced with a permeate side saline sweep. A series of OARO stages can be used to sequentially reduce the concentration of the feed until a traditional RO process can obtain fully desalinated water. This paper develops an OARO model to identify feasible operating conditions for this process and to estimate the water recovery and energy consumption across a range of brine feed concentrations. For a feed of 100–140 g/L sodium chloride, we estimate that the OARO process is capable of a 35–50% water recovery with an energy consumption of 6–19 kWh per m 3 of product water. Finally, the results suggest that an OARO dewatering process improves upon the recovery of reverse osmosis for high salinity brines and has a comparable or lower energy consumption than mechanical vapor compression.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Economic assessment of a multistage surface-heated vacuum membrane distillation process for the treatment of hypersaline produced water

Here, the treatment and disposal of hypersaline produced water remains a challenge, particularly for oil and gas producers in the Permian basin where production wells generate significant amounts of wastewater, and the traditional method of injecting wastewater into disposal wells is coming under increasing scrutiny. Here we investigate the viability of using solar energy to power a multi-stage, surface heated, vacuum membrane distillation (SHVMD) with energy recovery to treat hypersaline produced wastewater from Midland, Texas. Membrane distillation is a process that can desalinate waters with high total dissolved solids concentration, and when incorporated into a system with surface heating and energy recovery can achieve high water recovery rates. Model results show that a 6-stage SHVMD system with a 54.4 % water recovery rate and a gained output ratio (GOR) of 3.28 has the potential to be economically viable when used to treat hypersaline produced water in the Permian basin. Assuming energy costs of $\$0.03$/kWh thermal and $\$0.12$kWh electric , we estimate a project net present value (NPV) of $\$225,525$ and an internal rate of return (IRR) of 13.5 % when an air cooled condensor is used to cool the distillate and a NPV of $\$570,791$ and IRR of 24.52 % when a liquid coooling source is available.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Model calibration of a variable refrigerant flow system with a dedicated outdoor air system: A case study

With increased use of variable refrigerant flow (VRF) systems in the U.S. building sector, interests in capability and rationality of various building energy modeling tools to simulate VRF systems are rising. This paper presents the detailed procedures for model calibration of a VRF system with a dedicated outdoor air system (DOAS) by comparing to detailed measured data from an occupancy emulated small office building. The building energy model is first developed based on as-built drawings, and building and system characteristics available. The whole building energy modeling tool used for the study is U.S. DOE’s EnergyPlus version 8.1. The initial model is, then, calibrated with the hourly measured data from the target building and VRF-DOAS system. In a detailed calibration procedures of the VRF-DOAS, the original EnergyPlus source code is modified to enable the modeling of the specific VRF-DOAS installed in the building. After a proper calibration during cooling and heating seasons, the VRF-DOAS model can reasonably predict the performance of the actual VRF-DOAS system based on the criteria from ASHRAE Guideline 14-2014. The calibration results show that hourly CV-RMSE and NMBE would be 15.7% and 3.8%, respectively, which is deemed to be calibrated. As a result, the whole-building energy usage after calibration of the VRF-DOAS model is 1.9% (78.8 kWh) lower than that of the measurements during comparison period.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impacts of COVID-19 related stay-at-home restrictions on residential electricity use and implications for future grid stability

“Stay-at-home” orders and other health precautions enacted during the COVID-19 pandemic have led to substantial changes in residential electricity usage. Here, we conduct a case study to analyze data from 390 apartments in New York City (NYC) to examine the impacts of two key drivers of residential electricity usage: COVID-19 case-loads and the outdoor temperature. We develop a series of regression models to predict two characteristics of residential electricity usage on weekdays: The average occupied apartment’s consumption (kWh) over a 9am-5pm window and the hourly peak demand (Watt) over a 12pm-5pm window. Via a Monte Carlo simulation, we forecast the two usage characteristics under a possible scenario in which stay-at-home orders in NYC, or a similar metropolitan region, coincide with warm summer weather. Under the scenario, the 9am-5pm residential electricity usage on weekdays is predicted to be 15% – 24% higher than under prior, pre-pandemic conditions. This could lead to substantially higher utility costs for residents. Additionally, we predict that the residential hourly peak demand between 12pm and 5pm on weekdays could be 35% – 53% higher than that under pre-pandemic conditions. We conclude that the projected increase in peak demand - which might arise if stay-at-home guidelines coincided with hot weather conditions - could pose grid management challenges, especially for residential feeders. We also note that, if there is a longer lasting shift towards work and study-from-home, utilities will have to rethink load profile considerations. The applications of our predictive models to managing future smart-grid technology are also highlighted.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building envelope anomaly characterization and simulation using drone time-lapse thermography

Defects in building envelopes deteriorate over time without being visible to the human eye, while significantly impacting energy performance due to unaccounted heat transfer. Defects can be characterized in the infrared (IR) spectrum. However, IR readings are typically recorded at singular points in time, when in several cases anomalies can only be revealed at specific times of the day, possibly in different seasons of the year. This paper presents a novel workflow for 3D envelope defect characterization and modeling using aerial time-lapse IR data collection using drones. A comprehensive envelope thermal profile is developed for a case study building employing the photogrammetry software Agisoft Photoscan, which generates temporal IR inspections of building skins using multiple thermography orthomosaics. Point-cloud data is then translated into a CAD model and thermal zones for whole Building Energy Modeling (BEM) using Honeybee as a frontend to EnergyPlus to showcase the potential of inclusion of detailed 4D data. Envelope contributions in this case study’s anomalies showed heat losses of 6447.6 kWh, and Energy Use Intensity (EUI) differences of ~2 kWh/m 2 /year from the baseline. Finally, why there is currently little translation of this work in BEM software is discussed, while identifying limitations and future research in the employment of time-lapse thermography using drones for more accurate building envelope inspection and modeling.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Coupling thermal energy storage with a thermally anisotropic building envelope for building demand-side management across various US climate conditions

Here, the thermally anisotropic building envelope (TABE) is a novel active building envelope that enhances energy efficiency and thermal comfort in buildings by transferring heat and cold between building envelopes and hydronic loops. When coupled with thermal energy storage (TES) units, the TABE + TES enables the storage of both heat and cold energy captured by the TABE roof or exterior walls. This stored energy can be later released by the TABE floor for indoor heating and cooling, benefiting both the grid and the end user. This paper evaluates the merits of TABE + TES for building demand-side management across various US climate conditions, focusing on peak load shaving, annual energy savings, and cost savings under time-of-use (TOU) electric rate schedules. Simulations were conducted by integrating time-of-day–informed, rule-based control strategies in MATLAB, TABE components and TES units in COMSOL Multiphysics, and whole-building energy analysis in EnergyPlus. A case study using the US Department of Energy’s prototype single-family detached house model in Birmingham, Alabama; Los Angeles, California; Oak Ridge, Tennessee; and Denver, Colorado, showed that the TABE + TES system achieved (1) 70 % peak load shaving in Los Angeles and Denver and 20 % in Birmingham and Oak Ridge; (2) significant peak electricity savings of 351–497 kWh, reducing peak energy consumption by 38 %–78 %; and (3) annual heating cost savings of 0.79 $\$$/m2–1.17 $\$$/m 2 and cooling cost savings of 0.60 $\$$/m 2 –1.17 $\$$/m 2 using a normal utility rate or low-TOU rate. The benefits of employing the TABE + TES system are even more significant under high TOU rates.

25 ENERGY STORAGE↗

Experimental characterization and potential energy savings of insulated cladding for U.S. residential buildings

This study evaluates a novel insulated cladding composed of foamed cement and vinyl siding that is designed as a retrofit product to enhance thermal performance in U.S. residential buildings. Experimental measurements showed that foamed cement exhibits a thermal conductivity of 0.0334–0.0365 W/m-K (R-value of 4.0–4.3 °F⋅ft 2 ⋅h/BTU), which is significantly higher than that of conventional fiber cement boards. Although mechanical testing confirmed the material’s brittleness and low strength, it also indicated its suitability for nonstructural insulation applications. Water vapor permeability testing demonstrated effective moisture resistance with the polymer coating. To evaluate the insulated cladding’s energy performance, we used the U.S. Department of Energy’s prototype single-family building model and simulated across 50 locations spanning 16 International Energy Conservation Code climate zones. The R-7 (R-value of 7 °F⋅ft 2 ⋅h/BTU per inch) retrofit cladding resulted in heating energy savings up to 275 therms (Fairbanks, AK) and cooling energy savings up to 1,547 kWh (Phoenix, AZ). The energy cost savings varied by region, but the highest annual cost savings ($\$$434/year) were observed in Santa Maria, CA, and the highest annual cost savings percentage (37 %) were noted in Monterey, CA. On a national scale, the insulated retrofit provided an average annual energy cost reduction of 16 %, highlighting the cladding system’s broad applicability and financial viability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A kW-scale, 24-hour continuously operational, radiative sky cooling system: Experimental demonstration and predictive modeling

With the advancement in sub-ambient cooling of water during daytime under the sun with scalable-manufactured radiative cooling metamaterials, the challenge for applications lies in design and building of large-scale radiative cooling systems. Here, we present a kW-scale, 24-hour continuously operational, radiative sky cooling system, with both experimental study and detailed modeling. We first quantitatively show how water flow rate directly affects the system cooling power and inversely affects the water temperature drop. A day-and-night stagnant (flow rate = 0 L/(min·m 2 )) water cooling test of the system shows a consistent sub-ambient water temperature drop of 5–7 °C. A daytime cooling test of the system at a low flow rate of 0.227 L/(min·m 2 ) yields a maximum sub-ambient temperature drop of 4.0 °C with an average net cooling power of around 80 W/m 2 . Further modelling for a typical metrological year (in Phoenix, Arizona) shows that the system could generate as much as 350 kWh cold (or 26 kWh/m 2 ) with a sub-ambient temperature drop of 4–5 °C at a low flow rate of 0.1 L/(min·m 2 ) during a typical summer month. The cold generated could be used to assist AC systems in regions or seasons with high ambient temperatures.

30 DIRECT ENERGY CONVERSION↗

Techno-Economic Analysis of Recuperated Joule-Brayton Pumped Thermal Energy Storage

This article describes a techno-economic model for pumped thermal energy storage systems based on recuperated Joule-Brayton cycles and two-tank liquid storage. Models have been developed for each component, with particular emphasis on the heat exchangers. Economic metrics such as the power and energy capital costs (i.e., per-kW and per-kWh capacity) and levelized cost of storage are evaluated by gathering numerous cost correlations from the literature, thereby enabling estimates of uncertainty. It is found that the use of heat exchangers with effectivenesses up to 0.95 is economically worthwhile, but higher values lead to rapidly escalating component size and system cost. Several hot storage fluids are considered; those operating at the highest temperatures (chloride salts) improve the round-trip efficiency but the benefit is marginal and may not warrant the additional material costs and risk when compared to lower-temperature nitrate salts. Cost-efficiency trade-offs are explored using a multi-objective optimization algorithm, yielding optimal designs with round-trip efficiencies in the range 59-72% and corresponding levelized storage costs of 0.12 0.03 and 0.38 0.10 $/kWhe. Lifetime costs are competitive with lithium-ion batteries for discharging durations greater than 6 h under current scenarios.

Carnot battery↗

A novel method for co-optimizing battery sizing and charging strategy of battery electric bus fleets: An application to the city of Paris

Battery-electric buses (BEBs) are a promising technology for replacing diesel buses and reducing their environmental burden. However, their charging process can take several hours, depending on the charging technique and strategy, making them susceptible to schedule disruptions. Furthermore, the selection of the charging strategy and battery size can increase the total capital investment and operational expenses of a BEB fleet, which is a major obstacle to its adoption. Therefore, to minimize the total cost of ownership (TCO) and prevent schedule disruptions, it is essential to establish a well-defined approach to determine an appropriate battery size and charging strategy for BEB fleets. This paper presents a method for reducing the TCO of BEB by determining the optimal battery size and charging strategy for each bus while satisfying operating constraints. The method involves a two-step optimization algorithm that uses Dynamic Programming and Genetic Algorithm. Further, the study applies this approach to the bus fleet serving line 21 in Paris and generates the optimal battery sizing, charging strategy, and required charging infrastructure. The results indicate that 100 kWh batteries offer the best trade-off between capital and operational expenditure for the fleet deployment if used with 65–85 kW chargers at bus terminals.

33 ADVANCED PROPULSION SYSTEMS↗

Identification of hot water end-use process of electric water heaters from energy measurements

This paper presents an algorithm for the identification of parameters for a stochastic hot water end-use process that drives a homogeneous population of thermostatically controlled electric water heaters (EWH). Usually, only metered interval consumption data (kWh) is collected and the hot water end-use process is unobservable to utility and aggregators. However, the availability of EWHs for demand response (DR) is closely coupled with the hot water end-use process. In this context, the hot water end-use process is modeled as a two-state Markov chain (Use / No use), which causes the thermostatic ON-OFF switching process to behave as a Markov renewal process (MRP). A set of first passage-time problems is developed to obtain the moments of the transition probability densities of the MRP. These problems are addressed by establishing a system of coupled partial differential equations characterizing the temperature evolution of the EWH population. A key quantity in the methodology for estimating the parameters is the total time an EWH is ON within a period of interest. It is referred to as the total busy time. Total busy time in this approach is a random variable for which analytical expressions of the moments are developed as a function of the metered window length. The latter expressions become the basis of a hot water demand model identification algorithm which is validated using agent-based simulations of EWHs.

42 ENGINEERING↗

Thermal energy storage in concrete utilizing a thermosiphon heat exchanger

The performance of a lab-scale concrete thermal energy storage (TES) module with a 2-kWh thermal capacity is evaluated at temperatures up to 400 °C. The TES module uses conventional normal weight concrete with thermal and mechanical properties that are tailored for use as a solid thermal energy storage media. A thermosiphon heat exchanger is used to provide rapid heat transfer into the concrete module, which is reinforced with a steel pipe outer shell. The charging and discharging cycles are examined to assess the thermal performance of the concrete and thermosiphon. Based on the results of testing, the thermosiphon is able to repeatably charge the concrete module from 300 to 400 °C over a 4-h period. After 2250 total hours of charge and discharge cycles, there was no observed delamination between the concrete and the thermosiphon or the steel jacket reinforcement. Non-destructive measurements of the concrete indicated no significant degradation of the solid storage media. The experimental results are then used to validate a numerical model of the concrete TES module for parametric study. Finally, varying insulation conditions were analyzed using this model to determine practical configurations for regular operation of the proposed concrete TES module.

25 ENERGY STORAGE↗

Experimental driving performance evaluation of battery-powered medium and heavy duty all-electric vehicles

As the push to reduce air pollutants and carbon dioxide for global warming continues, there is increasing interest in the development and deployment of battery electric vehicles for heavy-duty applications as one of the critical and challenging steps of a broader effort to fully electrify the transportation sector. This study evaluated and quantified the energy consumption rates and energy regeneration rates for three heavy-duty battery electric vehicles (a step van, a yard tractor, and a class 8 truck) using driving cycle tests with a heavy-duty vehicle chassis dynamometer. Information in this area is currently very limited, and yet it is critical to understanding how effective heavy-duty battery electric vehicles will be for a wide range of applications as the electrification of the heavy-duty vehicle market continues to expand. Energy consumption rates ranged from 0.37 and 2.71 kWh/km for most vehicle/cycle combinations. On a diesel liter energy-equivalent basis, the heavy-duty vehicles had approximately 3 to 6 times better energy consumption rates compared to comparable diesel vehicles, with weight normalized energy consumption rates also comparing favorably to the current and future greenhouse gas/fuel economy standards for equivalent diesel vehicles. Based on battery capacities ranging from 80 to 215 kWh, the vehicle ranges varied from 38.18 km to 171.2 km, with ranges of 115.9 km to 171.2 km for most types of driving and lower ranges of 38.18 to 42.20 km for sustained grade cycles. Overall, the advantage of improved energy consumption rates coupled with improvements that can be expected for battery technology and vehicle range, provide promise for expanded use of heavy-duty vehicles going into the future.

33 ADVANCED PROPULSION SYSTEMS↗

Techno-economic and thermodynamic analysis of pre-cooling systems at gaseous hydrogen refueling stations

In this study, we conducted a techno-economic and thermodynamic analysis of precooling units (PCUs) at hydrogen refueling stations and developed a cost-minimizing design algorithm for the PCU observing the SAE J2601 refueling protocol for T40 stations. In so doing, we identified major factors that affect PCU cost and energy use. The hydrogen precooling energy intensity depends strongly on the station utilization rate, but approaches 0.3 kWh e /kg-H 2 at full utilization. In early fuel cell electric vehicle markets where utilization of the refueling capacity is low, the overhead cooling load (to keep the heat exchanger cold at -40°C) results in significantly high PCU energy intensity because only a small amount of hydrogen is being dispensed. We developed a parameterized precooling energy intensity prediction formula as a function of the ambient temperature and station utilization rate. We also found that the Joule-Thomson effect of the flow control device introduces a significant increase in temperature upstream of the PCU’s heat exchanger (HX), which impacts the PCU design capacity. An optimal PCU (per dispenser, at 35°C HX inlet temperature) consists of a 13-kW refrigerator and a HX with 1400 kg of thermal mass (aluminum), which currently costs $70,000 (uninstalled). Finally, the total (installed) capital and operation cost of PCU at a fully utilized hydrogen refueling station adds $0.50/kg-H 2 .

08 HYDROGEN↗

Ultra-high efficiency hydrogen production using a large-scale solid oxide electrolysis cell system

Efficient and cost-effective production of clean hydrogen is key to decarbonizing the production of hard-to-abate industries, such as chemicals, fuels, steel, cement and many other commodities that form the basis of modern societies. High-temperature steam electrolysis (HTSE) has recently become commercially available and offers opportunities for producing hydrogen at higher efficiency and lower cost than competing low temperature technologies. In this work, we report world record setting hydrogen production efficiency from large-scale prototype HTSE systems based on solid oxide electrolysis cell (SOEC) technology. Independent tests performed at Idaho National Laboratory (INL) employed a Bloom Energy 100 kW SOEC system to achieve a hydrogen production direct current specific electric energy consumption as low as 36.7 kWh per kilogram of hydrogen. Remarkably, similar high efficiencies in the range of 36–39 kW/kg-H2 were obtained over a wide range of hydrogen production rates and even during dynamic ramping as the hydrogen production and electric power consumption of the system were varied between 20 % and 100 % of nominal conditions. Furthermore, these test results validate previous projections that commercial SOEC systems can produce clean hydrogen at efficiencies approaching 100 % for less than 2 U S. dollars per kilogram when located near sources of inexpensive, low-grade heat and clean electricity.

08 HYDROGEN↗

Exergy analysis and operational efficiency of a horizontal ground-source heat pump system operated in a low-energy test house simulated occupancy conditions

This paper presents detailed analysis of a water to water ground source heat pump (WW-GSHP) to provide all the hot water needs in a 345 m 2 house located in DOE climate zone 4 (mixed-humid). The protocol for hot water use is based on the Building America Research Benchmark Definition (Hendron 2008; Hendron and Engebrecht 2010) which aims to capture the living habits of the average American household and its impact on energy consumption. The entire house was operated under simulated occupancy conditions. Detailed energy and exergy analysis provides a complete set of information on system efficiency and sources of irreversibility, the main cause of wasted energy. The WW-GSHP was sized at 5.275 kW (1.5-ton) for this house and supplied hot water to a 303 L (80 gal) water storage tank. The WW-GSHP shared the same ground loop with a 7.56 kW (2.1-ton) water to air ground source heat pump (WA-GSHP) which provided space conditioning needs to the entire house. Data, analyses, and measures of performance for the WW-GSHP in this paper complements the results of the WA-GSHP published in this journal (Ally, Munk et al. 2012). Understanding the performance of GSHPs is vital if the ground is to be used as a viable renewable energy resource.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Potential energy savings benefits and limitations of radiative cooling coatings for U.S. residential buildings

We report radiative coatings are a promising strategy to implement passive cooling that provides an eco-friendly pathway to achieve energy efficiency in buildings. This study investigates the benefits and limitations of implementing radiative coatings on the building envelope, particularly the roof, of residential buildings in the United States. The analysis compares the performance of an ideal radiative coating with broadband surface properties to a realistic radiative coating with diffuse and semitransparent properties. To enhance the net energy efficiency of buildings, we carried out a comprehensive parametric analysis comprising key radiation surface properties to maximize cooling energy savings while minimizing heating energy penalties. A countrywide assessment for 68 locations across the United States showed that net energy savings are a strong function of the climatic and atmospheric conditions. Broadly, southern locations showed high overall energy savings whereas northern locations exhibited high overall energy penalties. Locations in International Energy Conservation Code (IECC) climate zones 1A, 2A, and 2B showed a net annual energy savings above 5%, whereas locations in IECC climate zones 5B, 6B, and 7 showed a net annual energy penalty greater than 3%. The hot and dry climate of Phoenix, Arizona, showed the highest overall energy savings of 426 kWh (6.2%). Additionally, the mathematical correlation reveals that the net energy savings of a location is positive only when its average cooling degree days is greater than 5.5 or its average heating degree days is less than 10.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗