Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “iterative analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Design and Analysis of the US ITER Central Solenoid Module Lifting Fixture

The central solenoid (CS) consists of six large high field superconducting magnets (also known as modules) approximately 4 m in diameter and 2 m tall that weigh approximately 120 tonnes each. These large and complex modules create challenges during assembly of the CS that require the development of custom assembly tooling such as the CS lifting fixture. The CS module lifting fixture is designed to lift and stack the six CS modules in the assembly building on the ITER site. Because of its unique design, fabrication, and assembly features, no lifting attachments could be incorporated within or under the CS modules. This limitation motivated the development of a friction-based lift fixture. The design and evaluation of the CS module lifting fixture considered both worker safety and investment protection, and the assessments were performed to international codes and standards. The CS module lifting fixture consists of two principal subassemblies: spider assembly and ring weldment. These subassemblies allow the frictional force to be augmented by the mechanical advantage of shallow-angle wedges. Large radial preloads created by both screw jack assemblies and the weight of a CS module develop frictional forces capable of performing a lift with a safety factor of at least 2. The design effort resulted in the use of low friction linear bearings on angle surfaces to ensure constant pressure, integrated jacks for pretensioning the fixture prior to lifting, and load pin strain gauges for monitoring the normal force. Testing of various materials and surface treatments led to the selection of laminated aluminum and rubber pads as the friction interface on the CS lifting fixture side and a grit-blasted Nitronic 50 stainless steel band on the CS module side. A redundant lifting method using the module slings between the spider and module is also utilized after the initial friction lift. The CS lifting fixture provides a safe and reliable solution for lifting and stacking the CS module during assembly.

Morris, Eric↗

Analysis of the SOR iteration for the 9-point Laplacian

The SOR iteration for solving linear systems of equations depends upon an overrelaxation factor omega. A theory for determining omega was given by Young (1950) for consistently ordered matrices. Here the optimal omega is determined for the 9-point stencil for the model problem of Laplace's equation on a square. Several orderings of the equations are considered, including the natural rowwise and multicolor orderings, all of which lead to non-consistently ordered matrices, and two equivalence classes of orderings are found with different convergence behavior and optimal omega's. The results for the natural rowwise ordering are compared to those of Garabedian (1956) and it is explained why both results are, in a sense, correct, even though they differ. Also analyzed is a pseudo SOR method for the model problem and it is shown that it is not as effective as the SOR methods. Finally, the point SOR methods are compared to known results for line SOR methods for this problem.

Loyce M. Adams↗

Discrete fourier transform (DFT) analysis for applications using iterative transform methods

According to various embodiments, a method is provided for determining aberration data for an optical system. The method comprises collecting a data signal, and generating a pre-transformation algorithm. The data is pre-transformed by multiplying the data with the pre-transformation algorithm. A discrete Fourier transform of the pre-transformed data is performed in an iterative loop. The method further comprises back-transforming the data to generate aberration data.

Dean, Bruce H.↗

Extended Analytic Device Optimization Employing Asymptotic Expansion

Analytic optimization of a thermoelectric junction often introduces several simplifying assumptionsincluding constant material properties, fixed known hot and cold shoe temperatures, and thermallyinsulated leg sides. In fact all of these simplifications will have an effect on device performance,ranging from negligible to significant depending on conditions. Numerical methods, such as FiniteElement Analysis or iterative techniques, are often used to perform more detailed analysis andaccount for these simplifications. While numerical methods may stand as a suitable solution scheme,they are weak in gaining physical understanding and only serve to optimize through iterativesearching techniques. Analytic and asymptotic expansion techniques can be used to solve thegoverning system of thermoelectric differential equations with fewer or less severe assumptionsthan the classic case. Analytic methods can provide meaningful closed form solutions and generatebetter physical understanding of the conditions for when simplifying assumptions may be valid.In obtaining the analytic solutions a set of dimensionless parameters, which characterize allthermoelectric couples, is formulated and provide the limiting cases for validating assumptions.Presentation includes optimization of both classic rectangular couples as well as practically andtheoretically interesting cylindrical couples using optimization parameters physically meaningful toa cylindrical couple. Solutions incorporate the physical behavior for i) thermal resistance of hot andcold shoes, ii) variable material properties with temperature, and iii) lateral heat transfer through legsides.

Thermoelectric Generators↗

Low Complexity Turbo-like Codes

This paper addresses the iterative devoding analysis, design, and performance of low complexity turbo like codes.

turbo-like codes iterative decoding analysis conca↗

Stability Analysis of Inline ZFP Compression for Floating-Point Data in Iterative Methods

Currently, the dominating constraint in many high performance computing applications is data capacity and bandwidth, in both internode communications and even moreso in intranode data motion. A new approach to address this limitation is to make use of data compression in the form of a compressed data array. Storing data in a compressed data array and converting to standard IEEE-754 types as needed during a computation can reduce the pressure on bandwidth and storage. However, repeated conversions (lossy compression and decompression) introduce additional approximation errors, which need to be shown to not significantly affect the simulation results. Here, we extend recent work that analyzed the error of a single use of compression and decompression of the ZFP compressed data array representation to the case of time-stepping and iterative schemes, where an advancement operator is repeatedly applied in addition to the conversions. We show that the accumulated error for iterative methods involving fixed-point and time evolving iterations is bounded under standard constraints. An upper bound is established on the number of additional iterations required for the convergence of stationary fixed-point iterations. An additional analysis of traditional forward and backward error of stationary iterative methods using ZFP compressed arrays is also presented. The results of several 1D, 2D, and 3D test problems are provided to demonstrate the correctness of the theoretical bounds.

97 MATHEMATICS AND COMPUTING↗

Scanning Transmission Electron Microscopy–Atom Probe Tomography Correlative Analysis for the Characterization of Solute-defect Interactions

Atom probe tomography (APT) and (scanning) transmission electron microscopy ((S)TEM) are complementary techniques that provide spatially resolved chemical and structural information at the atomic scale. Here, in this study, we employ two different STEM/APT correlative analysis methods to investigate Cr segregation at dislocation loops in ultra-high purity Fe–Cr alloys. APT needles for the correlative analysis were extracted either from bulk material or from thinned TEM lamellae. STEM analysis was used to determine the Burgers vectors of ion-irradiation-induced dislocation loops, while APT reconstruction of the same region revealed the Cr segregation to these loops. We extended the g•b = 0 invisibility criterion of dislocation loops from TEM mode in a lamella to STEM mode in a needle-shaped specimen. STEM and APT analysis on the same needle provide straightforward correlative analysis, although it is limited by a small observation volume. In contrast, iterative STEM analysis of TEM lamellae, followed by the selective extraction of specific regions of interest for APT analysis, expands the observation area by up to 100 times but requires additional time-consuming steps for APT needle extraction from the lamellae.

47 OTHER INSTRUMENTATION↗

ITER Generic Diagnostic Upper Port Plug Nuclear Heating and Personnel Dose Rate Assesment Neutronics Analysis using the ATTILA Discrete Ordinates Code

Neutronics analysis to find nuclear heating rates and personnel dose rates were conducted in support of the integration of diagnostics in to the ITER Upper Port Plugs. Simplified shielding models of the Visible-Infrared diagnostic and of the ECH heating system were incorporated in to the ITER global CAD model. Results for these systems are representative of typical designs with maximum shielding and a small aperture (Vis-IR) and minimal shielding with a large aperture (ECH). The neutronics discrete-ordinates code ATTILA® and SEVERIAN® (the ATTILA parallel processing version) was used. Material properties and the 500 MW D-T volume source were taken from the ITER “Brand Model” MCNP benchmark model. A biased quadrature set equivelant to Sn=32 and a scattering degree of Pn=3 were used along with a 46-neutron and 21-gamma FENDL energy subgrouping. Total nuclear heating (neutron plug gamma heating) in the upper port plugs ranged between 380 and 350 kW for the Vis-IR and ECH cases. The ECH or Large Aperture model exhibited lower total heating but much higher peak volumetric heating on the upper port plug structure. Personnel dose rates are calculated in a three step process involving a neutron-only transport calculation, the generation of activation volume sources at pre-defined time steps and finally gamma transport analyses are run for selected time steps. ANSI-ANS 6.1.1 1977 Flux-to-Dose conversion factors were used. Dose rates were evaluated for 1 full year of 500 MW DT operation which is comprised of 3000 1800-second pulses. After one year the machine is shut down for maintenance and personnel are permitted to access the diagnostic interspace after 2-weeks if dose rates are below 100 μSv/hr. Dose rates in the Visible-IR diagnostic model after one day of shutdown were 130 μSv/hr but fell below the limit to 90 μSv/hr 2-weeks later. The Large Aperture or ECH style shielding model exhibited higher and more persistent dose rates. After 1-day the dose rate was 230 μSv/hr but was still at 120 μSv/hr 4-weeks later. __________________________________________________

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Stability analysis of nonlinear two-grid method for multigroup neutron diffusion problems

We present theoretical analysis of a nonlinear acceleration method for solving multigroup neutron diffusion problems. This method is formulated with two energy grids that are defined by (i) fine-energy groups structure and (ii) coarse grid with just a single energy group. The coarse-grid equations are derived by averaging of the multigroup diffusion equations over energy. The method uses a nonlinear prolongation operator. We perform stability analysis of iteration algorithms for inhomogeneous (fixed-source) and eigenvalue neutron diffusion problems. To apply Fourier analysis the equations of the method are linearized about solutions of infinite-medium problems. The developed analysis enables us to predict convergence properties of this two-grid method in different types of problems. Numerical results of problems in 2D Cartesian geometry are presented to confirm theoretical predictions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluating the reforested area for the municipality of Buri by automatic analysis of LANDSAT imagery

The author has identified the following significant results. The class of reforestation (Pinus, Eucalyptus, Araucaria) was defined using iterative image analysis (1-100) and LANDSAT MSS data. Estimates of class area by 1-100 were compared with data supplied by the forestry institute in Sao Paulo. LANDSAT channels 4 and 5 served to differentiate the Pinus, Eucalyptus, and Araucaria from the other trees. Channels 6 and 7 gave best results for differentiating between the classes. A good representative spectral response was obtained for Auraucaria on these two channels. The small relative differences obtained were +4.24% for Araucaria, -7.51% for Pinus, and -32.07% for Eucalyptus.

Dejesusparada, N.↗

Disordered glycometabolism involved in pathogenesis of Kashin–Beck disease, an endemic osteoarthritis in China

Kashin–Beck disease (KBD) is a chronic endemic osteoarthritis in China. Previous studies have suggested a role of metabolic dysfunction in causation of this disease. In this investigation, the metabolomics approach and cell experiments were used to discover the metabolic changes and their effects on KBD chondrocytes. Nuclear magnetic resonance ({sup 1}H NMR) spectroscopy was used to examine serum samples from both the KBD patients and normal controls. The pattern recognition multivariate analysis (OSC–PLS) and quantitative analysis (QMTLS iterator) revealed altered glycometabolism in KBD, with increased glucose and decreased lactate and citrate levels. IPA biological analysis showed the centric location of glucose in the metabolic network. Massive glycogen deposits in chondrocytes and increased uptake of glucose by chondrocytes further confirmed disordered glycometabolism in KBD. An in vitro study showed the effects of disordered glycometabolism in chondrocytes. When chondrocytes were treated with high glucose, expression of type II collagen and aggrecan were decreased, while TNF-α expression, the level of cellular reactive oxygen species and cell apoptosis rates all were increased. Therefore, our results demonstrated that disordered glycometabolism in patients with KBD was linked to the damage of chondrocytes. This may provide a new basis for understanding the pathogenesis of KBD. - Highlights: • Disordered glycometabolism in KBD was demonstrated by combining serum metabolomics and chondrocyte studies. • Glucose and TNF-α were key molecules linked to altered metabolism and inflammation in the pathophysiology of KBD. • The glycometabolism disorder was linked to expression of type II collagen and aggrecan, ROS and apoptosis of KBD chondrocytes.

60 APPLIED LIFE SCIENCES↗

Combining Static Analysis and Model Checking for Software Analysis

We present an iterative technique in which model checking and static analysis are combined to verify large software systems. The role of the static analysis is to compute partial order information which the model checker uses to reduce the state space. During exploration, the model checker also computes aliasing information that it gives to the static analyzer which can then refine its analysis. The result of this refined analysis is then fed back to the model checker which updates its partial order reduction. At each step of this iterative process, the static analysis computes optimistic information which results in an unsafe reduction of the state space. However we show that the process converges to a fired point at which time the partial order information is safe and the whole state space is explored.

Brat, Guillaume↗

Comparing direct and iterative equation solvers in a large structural analysis software system

Two direct Choleski equation solvers and two iterative preconditioned conjugate gradient (PCG) equation solvers used in a large structural analysis software system are described. The two direct solvers are implementations of the Choleski method for variable-band matrix storage and sparse matrix storage. The two iterative PCG solvers include the Jacobi conjugate gradient method and an incomplete Choleski conjugate gradient method. The performance of the direct and iterative solvers is compared by solving several representative structural analysis problems. Some key factors affecting the performance of the iterative solvers relative to the direct solvers are identified.

Poole, E. L.↗

B-spline active rays segmentation of microcalcifications in mammography

Accurate segmentation of microcalcifications in mammography is crucial for the quantification of morphologic properties by features incorporated in computer-aided diagnosis schemes. A novel segmentation method is proposed implementing active rays (polar-transformed active contours) on B-spline wavelet representation to identify microcalcification contour point estimates in a coarse-to-fine strategy at two levels of analysis. An iterative region growing method is used to delineate the final microcalcification contour curve, with pixel aggregation constrained by the microcalcification contour point estimates. A radial gradient-based method was also implemented for comparative purposes. The methods were tested on a dataset consisting of 149 mainly pleomorphic microcalcification clusters originating from 130 mammograms of the DDSM database. Segmentation accuracy of both methods was evaluated by three radiologists, based on a five-point rating scale. The radiologists' average accuracy ratings were 3.96{+-}0.77, 3.97{+-}0.80, and 3.83{+-}0.89 for the proposed method, and 2.91{+-}0.86, 2.10{+-}0.94, and 2.56{+-}0.76 for the radial gradient-based method, respectively, while the differences in accuracy ratings between the two segmentation methods were statistically significant (Wilcoxon signed-ranks test, p<0.05). The effect of the two segmentation methods in the classification of benign from malignant microcalcification clusters was also investigated. A least square minimum distance classifier was employed based on cluster features reflecting three morphological properties of individual microcalcifications (area, length, and relative contrast). Classification performance was evaluated by means of the area under ROC curve (A{sub z}). The area and length morphologic features demonstrated a statistically significant (Mann-Whitney U-test, p<0.05) higher patient-based classification performance when extracted from microcalcifications segmented by the proposed method (0.82{+-}0.06 and 0.86{+-}0.05, respectively), as compared to segmentation by the radial gradient-based method (0.71{+-}0.08 and 0.75{+-}0.08). The proposed method demonstrates improved segmentation accuracy, fulfilling human visual criteria, and enhances the ability of morphologic features to characterize microcalcification clusters.

61 RADIATION PROTECTION AND DOSIMETRY↗