Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ion identification systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

158 records · Page 9

Development and implementation of high-throughput proteomic and metabolomics assays by using advanced chromatographic and mass spectrometric systems (CRADA Final Report)

The mission of this CRADA with Agilent was to couple powerful MS platforms (QQQ, IM-QTOFMS) with Agilent’s novel Ultra-High-Performance Liquid Chromatography (UHPLC) fast metabolomic workflows and perform ABF Machine Learning (ML) to generated datasets. Agilent transferred UHPLC methods to PNNL and LBNL and methods were implemented and demonstrated in both labs, achieving total acquisition times of < 10 min. Metabolites analyzed using Agilent’s shared methods included metabolites from central carbon metabolism, common across hosts, and metabolites unique to engineered strains. Standards were acquired in an UHPLC-Drift Tube Ion Mobility Mass Spectrometer (DTIMS) system for the first time within the context of ABF and methods were optimized based on Agilent’s protocols. Samples from ABF hosts Pseudomonas putida, Aspergillus pseudoterreus, Aspergillus niger and Rhodosporidium toruloides were analyzed using the UHPLC-DTIMS platform for a total of 276 runs. A data analysis workflow compatible with the Experimental Data Depot (EDD) and completely shareable was developed for the acquired UHPLC-DTIMS data. Samples were analyzed using a Data Independent Acquisition Approach (DIA), which for most of the standards provided more transitions therefore increasing detection confidence. Using the data acquired by PNNL, LBNL, and Agilent’s specifications from previous ML projects, SNL applied an ensemble ML strategy to pick the best performing model for automated LC-method selection. Finally, with the contribution of the participant labs and Agilent, SNL developed an Automated Method Selection (AMS) software tool to predict the best liquid chromatography method for analysis of any new molecules of interest. Samples with novel pathways and new metabolite targets of interest are generated at a high pace in the ABF. Overall, the project advanced rapid metabolomics by combining liquid chromatography, ion mobility spectrometry, and data-independent mass spectrometry with machine learning. This multidimensional approach uses retention time, collision cross-section, precursor mass, and fragment-ion information to distinguish chemically similar metabolites that can be difficult to resolve using conventional liquid- or gas-chromatography methods. The resulting workflow also provided automated metabolite-identification error estimates, addressing a recognized need for statistical confidence measures in metabolomics.

Petzold, Christopher [Lawrence Berkeley National L↗

XANES reflects coordination change and underlying surface disorder of zinc adsorbed to silica

In this work, zinc K -edge X-ray absorption near-edge structure (XANES) spectroscopy of Zn adsorbed to silica and Zn-bearing minerals, salts and solutions was conducted to explore how XANES spectra reflect coordination environment and disorder in the surface to which a metal ion is sorbed. Specifically, XANES spectra for five distinct Zn adsorption complexes (Zn ads ) on quartz and amorphous silica [SiO 2(am) ] are presented from the Zn–water–silica surface system: outer-sphere octahedral Zn ads on quartz, inner-sphere octahedral Zn ads on quartz, inner-sphere tetrahedral Zn ads on quartz, inner-sphere octahedral Zn ads on SiO 2(am) and inner-sphere tetrahedral Zn ads on SiO 2(am) . XANES spectral analysis of these complexes on quartz versus SiO 2(am) reveals that normalized peak absorbance and K -edge energy position generally decrease with increasing surface disorder and decreasing Zn–O coordination. On quartz, the absorption-edge energy of Zn ads ranges from 9663.0 to 9664.1 eV for samples dominated by tetrahedrally versus octahedrally coordinated species, respectively. On SiO 2(am) , the absorption-edge energy of Zn ads ranges from 9662.3 to 9663.4 eV for samples dominated by tetrahedrally versus octahedrally coordinated species, respectively. On both silica substrates, octahedral Zn ads presents a single K -edge peak feature, whereas tetrahedral Zn ads presents two absorbance features. The energy space between the two absorbance peak features of the XANES K -edge of tetrahedral Zn ads is 2.4 eV for Zn on quartz and 3.2 eV for Zn on SiO 2(am) . Linear combination fitting of samples with a mixture of Zn ads complex types demonstrates that the XANES spectra of octahedral and tetrahedral Zn ads on silica are distinct enough for quantitative identification. These results suggest caution when deciphering Zn speciation in natural samples via linear combination approaches using a single Zn ads standard to represent sorption on a particular mineral surface. Correlation between XANES spectral features and prior extended X-ray absorption fine structure (EXAFS) derived coordination environments for these Zn ads on silica samples provides insight into Zn speciation in natural systems with XANES compatible Zn concentrations too low for EXAFS analysis.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Wireless Chalcogenide Nanoionic-Based Radio-Frequency Switch

A new nonvolatile nanoionic switch is powered and controlled through wireless radio-frequency (RF) transmission. A thin layer of chalcogenide glass doped with a metal ion, such as silver, comprises the operational portion of the switch. For the switch to function, an oxidizable electrode is made positive (anode) with respect to an opposing electrode (cathode) when sufficient bias, typically on the order of a few tenths of a volt or more, is applied. This action causes the metal ions to flow toward the cathode through a coordinated hopping mechanism. At the cathode, a reduction reaction occurs to form a metal deposit. This metal deposit creates a conductive path that bridges the gap between electrodes to turn the switch on. Once this conductive path is formed, no further power is required to maintain it. To reverse this process, the metal deposit is made positive with respect to the original oxidizable electrode, causing the dissolution of the metal bridge thereby turning the switch off. Once the metal deposit has been completely dissolved, the process self-terminates. This switching process features the following attributes. It requires very little to change states (i.e., on and off). Furthermore, no power is required to maintain the states; hence, the state of the switch is nonvolatile. Because of these attributes the integration of a rectenna to provide the necessary power and control is unique to this embodiment. A rectenna, or rectifying antenna, generates DC power from an incident RF signal. The low voltages and power required for the nanoionic switch control are easily generated from this system and provide the switch with a novel capability to be operated and powered from an external wireless device. In one realization, an RF signal of a specific frequency can be used to set the switch into an off state, while another frequency can be used to set the switch to an on state. The wireless, miniaturized, and nomoving- part features of this switch make it suitable for applications such as integration into garments, RFID (radio-frequency identification) tags, and conformal structures (e.g., aircraft wings, sounding rockets contours, etc). In the case of RFID tags the innovation will provide countermeasures to attempts for identity theft and other uninvited attempts for retrieval of information. It could also be applicable to the automotive industry as well as the aerospace industry for collision avoidance and phased array radar systems, respectively

Nessel, James↗

Automated Desalting Apparatus

Because salt and metals can mask the signature of a variety of organic molecules (like amino acids) in any given sample, an automated system to purify complex field samples has been created for the analytical techniques of electrospray ionization/ mass spectroscopy (ESI/MS), capillary electrophoresis (CE), and biological assays where unique identification requires at least some processing of complex samples. This development allows for automated sample preparation in the laboratory and analysis of complex samples in the field with multiple types of analytical instruments. Rather than using tedious, exacting protocols for desalting samples by hand, this innovation, called the Automated Sample Processing System (ASPS), takes analytes that have been extracted through high-temperature solvent extraction and introduces them into the desalting column. After 20 minutes, the eluent is produced. This clear liquid can then be directly analyzed by the techniques listed above. The current apparatus including the computer and power supplies is sturdy, has an approximate mass of 10 kg, and a volume of about 20 20 20 cm, and is undergoing further miniaturization. This system currently targets amino acids. For these molecules, a slurry of 1 g cation exchange resin in deionized water is packed into a column of the apparatus. Initial generation of the resin is done by flowing sequentially 2.3 bed volumes of 2N NaOH and 2N HCl (1 mL each) to rinse the resin, followed by .5 mL of deionized water. This makes the pH of the resin near neutral, and eliminates cross sample contamination. Afterward, 2.3 mL of extracted sample is then loaded into the column onto the top of the resin bed. Because the column is packed tightly, the sample can be applied without disturbing the resin bed. This is a vital step needed to ensure that the analytes adhere to the resin. After the sample is drained, oxalic acid (1 mL, pH 1.6-1.8, adjusted with NH4OH) is pumped into the column. Oxalic acid works as a chelating reagent to bring out metal ions, such as calcium and iron, which would otherwise interfere with amino acid analysis. After oxalic acid, 1 mL 0.01 N HCl and 1 mL deionized water is used to sequentially rinse the resin. Finally, the amino acids attached to the resin, and the analytes are eluted using 2.5 M NH4OH (1 mL), and the NH4OH eluent is collected in a vial for analysis.

Spencer, Maegan K.↗

First Observation of Multiphonon 𝛾-Vibrations in an Odd-Odd Nuclear System

Here, the identification of the first multiphonon 𝛾-vibrational bands in an odd-odd neutron-rich nucleus of the nuclear chart is presented. These high-spin structures of hard to access $^{104}_{41}\textrm{Nb}_{63}$, produced in fission, were studied by combining a spectrometer with isotopic resolution coupled to a 𝛾-ray tracking array and independently from high-fold 𝛾 coincidence measurements. Triaxial projected shell model calculations for the high-spin states are in good agreement with the measured observables for the yrast, one-phonon, and two-phonon 𝛾 bands. The possibility of an oblate shape of an isomeric state and coexistence of triaxial and oblate configurations is investigated from the decay of the 141 keV isomer. The present Letter illustrates the robustness of vibration excitations in the presence of an odd valence proton and neutron as well as the possibly coexisting shapes beyond the 𝑁 = 60 transitional region.

Wang, E. H. [Shandong Univ., Jinan (China); Vander↗

Key Observations and Discoveries from the Vector Electric Field Investigation on the C/NOFS Satellite

Launched in 2008 and operating for 7.5 years, the Air Force Communication /Navigation Outage Forecasting System (C/NOFS) satellite included the Vector Electric Field Investigation (VEFI) designed and built at NASA’s Goddard Space Flight Center. VEFI successfully met its objectives: 1) investigate the role of ambient electric fields in initiating nighttime density depletions and turbulence; 2) determine the quasi-DC electric fields associated with abrupt density depletions, and 3) quantify the spectrum of the irregularities associated with density depletions, providing many key observations and discoveries including: -- Global (low latitude) vector DC electric fields at 16 s/sec revealing variations with local time, longitude, and season between extremely low and moderate solar activity-- Reversed zonal E x B drifts below the F-region ledge at sunset and simultaneous observations of large scale Kelvin-Helmholtz instabilities as seeds of spread-F -- Large expanses of quasi-coherent kilometer-scale vector wave observations (electric field and density) below 450 km and their discovery as a source of scintillations using the C/NOFS GPS -- Reversed zonal DC electric fields and simultaneous observations of afternoon counter electrojet-- Enhanced zonal DC electric fields at sunrise and full vector plasma flow continuity at the terminator-- Vector electric field and density irregularities extending to meter-scales within equatorial plasma depletions -- Intense electric field structure within the equatorial ionosphere at night in the absence of density depletions -- First observations of the westward equatorial electrojet in post-midnight ionosphere and possible association with downward meridional drifts-- Spaceborne Dst observations and implications for ring current asymmetries-- Vector electric and magnetic field Poynting flux within depletions and TIDs-- Measurements of ionospheric reflectance and Alfvenic waves associated with TIDs-- Observations of Alfven resonators -- ULF magnetic field structure within the nightime equatorial ionosphere-- Discovery of Schumman resonances in space and implications of ELF radiowave propagation-- Vector observations of 50-60 Hz powerline radiation without harmonics-- Ion cyclotron resonance absorption lines associated with ELF hiss and the identification of ambient ions-- Parallel electric fields associated with lower hybrid waves driven by thunderstorm lightning-related sferics-- Discovery of Z-mode radiation in the equatorial ionosphere including its associated with density depletions-- Optical lightning detector waveforms and electric field sferics observed up to altitudes of 800 km

Robert F Pfaff↗

Machine Learning Benchmarks for the Classification of Equivalent Circuit Models from Electrochemical Impedance Spectra

Analysis of Electrochemical Impedance Spectroscopy (EIS) data for electrochemical systems often consists of defining an Equivalent Circuit Model (ECM) using expert knowledge and then optimizing the model parameters to deconvolute various resistance, capacitive, inductive, or diffusion responses. For small data sets, this procedure can be conducted manually; however, it is not feasible to manually define a proper ECM for extensive data sets with a wide range of EIS responses. Automatic identification of an ECM would substantially accelerate the analysis of large sets of EIS data. We showcase machine learning methods to classify the ECMs of 9,300 impedance spectra provided by QuantumScape for the BatteryDEV hackathon. The best-performing approach is a gradient-boosted tree model utilizing a library to automatically generate features, followed by a random forest model using the raw spectral data. A convolutional neural network using boolean images of Nyquist representations is presented as an alternative, although it achieves a lower accuracy. We publish the data and open source the associated code. The approaches described in this article can serve as benchmarks for further studies. A key remaining challenge is the identifiability of the labels, underlined by the model performances and the comparison of misclassified spectra.

25 ENERGY STORAGE↗

High-Throughput Characterization and Optimization of Polyamide Hydrolase Activity Using Open Port Sampling Interface Mass Spectrometry

Enzymatic biodegradation of polymers, such as polyamides (PA), has the potential to cost-effectively reduce plastic waste, but enhancements in degradation efficiency are needed. Engineering enzymes through directed evolution is one pathway toward identification of critical domains needed for improving activity. However, screening such enzymatic libraries (100s-to-1000s of samples) is time-consuming. Here we demonstrate the use of robotic autosampler (PAL) and immediate drop on demand technology (I.DOT) liquid handling systems coupled with open-port sampling interface-mass spectrometry (OPSI-MS) to screen for PA6 and PA66 hydrolysis by 6-aminohexanoate-oligomer endo-hydrolase (nylon hydrolase, NylC) in a high-throughput (8–20 s/sample) manner. The OPSI-MS technique required minimal sample preparation and was amenable to 96-well plate formats for automated processing. Enzymatic hydrolysis of PA characteristically produced soluble linear oligomer products that could be identified by OPSI-MS. Incubation temperatures and times were optimized for PA6 (65 °C, 24 h) and PA66 (75 °C, 24 h) over 108 experiments. In addition, the I.DOT/OPSI-MS quantified production of PA6 linear dimer (8.3 ± 1.6 μg/mL) and PA66 linear monomer (13.5 ± 1.5 μg/mL) by NylC with a lower limit of detection of 0.029 and 0.032 μg/mL, respectively. For PA6 and PA66, linear oligomer production corresponded to 0.096 ± 0.018% and 0.204 ± 0.028% conversion of dry pellet mass, respectively. The developed methodology is expected to be utilized to assess enzymatic hydrolysis of engineered enzyme libraries, comprising hundreds to thousands of individual samples.

47 OTHER INSTRUMENTATION↗

Micrometer to Atomic Scale Characterisation of Primitive Astromaterials Using A Novel Method, Metis-Fa: A Coordinated Atom Probe Tomography, Transmission Electron Microscopy and NanoSIMS Approach

Introduction: Presolar grains preserve isotopic, chemical and microstructural records of physical and chemical processing, and formation mechanisms within a vast range of evolved stellar systems, the interstellar medium, solar nebula and their parent bodies. These evolutionary records are preserved at the micrometric to atomic scale, requiring coordinated studies to expand our understanding of evolutionary processes occurringthroughout ours and external stellar systems [1]. NanoSIMS enabled rapid in situ identification and isotopic characterisation of presolar grains and their stellar origins using 17O/16O and 18O/16O, and 13C/12C isotopic ratios [1]. Coordination with transmission electron microscopy (TEM) revealed crystallographic and localised contextual relationships and quantitively constrained their major and minor compositions [1]. However, trace elements cannot be quantified, the most sensitive geochemical tracers of environmental conditions, essential to unravelling the chemical record of their evolutionary pathway and parent stellar systems [2-3] . Furthermore, owing to the combination of technical limitations (only 5 – 7 isotopes can be measured per NanoSIMS run) and their small grain sizes of 100 nm < 3 μm (with rare exceptions in nanodiamonds (2 nm ≤) and SiC (< 40 μm)), the number of measurable isotopes per grain volume is limited [1,3] . Through more comprehensive isotopic studies of presolar grains, NanoSIMS studies have shown the importance of the latter, identifying Fe and Mg as important indicators of nuclear synthetic processing and their stellar origins, respectively [4- 5]. Coordination of NanoSIMS and Atom Probe Tomography (APT) revealed morphological signatures, and isotopic and chemical signatures at major to trace levels without requirements for preselection of elements [6]. However, crystallographic signatures in localized contextual relationships cannot be measured. Consequently, coordination of NanoSIMS, TEM and APT is essential to gain access to almost all contextual, structural and geochemical signatures within each presolar grain.Transmission electron microscopy requires a 100 nm thin lamella which is unstable in APT and would not produce any viable data. Atom probe tomography requires a needle-shaped specimen which when measured in TEM removes the local context, impacts the quality of the TEM diffraction images due to the shank angle of the needle, and can alter the chemistry of beam sensitive materials from the higher degree of surface exposure at the tip. To address these issues, we developed METIS-Fa (Multi-technical measurements of Electron Transparent materials using an Indium Sandwich - a FIB approach). A novel method which enables coordination of NanoSIMS, TEM and APT for generalized and targeted studies of individual grains, including beam sensitive materials, without compromising sample preparation requirements for TEM and APT. This method requires only indium and a Focus Ion Beam (FIB), minimizing the movement of fragile materials while still enabling preparation of TEM lamella into APT needles. Samples: Initial experimental development and testing of the method occurred at Astromaterials Research and Exploration Science (ARES), Johnson Space Centre (JSC), NASA and APT measurements and needle preparation occurred at JdLC, Curtin University. Synthetic silicate samples were used as analogs for presolar silicates when performing a trial run of the method. Samples were extracted from a polished thin section created at JSC, NASA, comprised of 38 wt.% Si, 17 wt.% FeO, 13 wt.% MgO, 12 wt.% Al, 11 wt.% Ca based on electron microprobe analysis (EMPA) [8] . Experimental details, pressure and temperature conditions were presented in [8] and references therein. Testing of the capability to target individual grains in mineral matrices using this method for acquisition in APT, measured matrix regions in meteoritic thin sections of primitive meteorites. These meteorites and their identified presolar grains for future targeted studies are detailed in [9]. Techniques: The TEM-FIB lamella were prepared using a FIB. An e-beam assisted pt deposition was used as a protective coating for the synthetic and meteoritic samples. When targeting individual grains, a secondary e-beam assisted pt deposition button is placed over the desired grain before the protective coating to denote its location. A JEOL 2500SE field-emission TEM was used for high-resolution imaging, energy-dispersive X-ray (EDX) and electron diffraction data.TheMETIS-Fa method was experimentally designed, tested and executed using a FIB at ARES, JSCNASA. Needles for APT were prepared using the Tescan Lyra3 GM Dual Beam Focus Ion Beam (FIB) Field Emission SEM (FE-SEM) at the JdLC, Curtin University. Atom probe tomography measurements were conducted using a CAMECA Local Electrode Atom Probe, LEAP 4000X HR. Two pure indium needles were analyzed initially to constraining acquisition parameters and stability under the beam. Manual acquisition was required to maintain evaporation of specimen’s at the apex and monitor interactions with measurement parameters. Experimental Design: Indium foil is pressed onto an Al stub with a pneumatic press and mounted into the FIB adjacent to the TEM-FIB lamella of interest. Using a FIB, two indium slices (5 μm x ~300 nm x 3 μm) are extracted from indium foil and aligned with the TEM-FIB lamella before touching the TEM-FIB lamella. Each slice is then attached through cold welding to the FIB-TEM lamella. This approach eliminates the need for chemical treatments and proved effective for aligning the Indium within the region of interest for APT, holding it in place for up to 4 days during testing.Once both indium slices are attached within their pre-determined region per grain targeting requirements, they are gradually melted onto the FIB-TEM lamella.When targeting a specific grain, measurements should be taken of the pt button and its distance from edge to edge of the lamella before and after sandwiching. A secondary button should be placed over the same region after the Indium slices have been attached to improve precision when preparing APT needles. Results: Figure 1 shows two indium slices melted onto a FIB-TEM lamella, adding additional bulk for preparation into APT needles as shown in Figure 2 [7] . The latter was essential so samples could be measured in TEM and APT without compromising sample preparation requirements and consequently data quality and acquisition stability. METIS-Fa proved effective forimproving geometry. Figure 3 shows a successful APTrun of the synthetic silicate. EMPA, TEM and APTshowed no chemical alterations. During targetingtesting, a solar silicate grain was successfully identifiedand measured in TEM, and prepared into an APTneedle. However, the indium was melted too long during sample preparation, causing expansion andformation of internal porosity leading to sample loss.Conclusion: METIS-Fa greatly expands the number of isotopic and chemical signatures measured per grain volume, and enables measurements of contextual, structural, crystallographic, isotopic and geochemical signatures within individual grains. Gaining access to such a vast range of evolutionary signatures required for expanding our understanding of external stellar and planetary systems and the evolution of our solar system. This method was designed for application to a vast range of phases including being sensitive materials and thus provides a way for coordination of NanoSIMS, TEM and APT not just for the study of presolar grains and by extension primitive astromaterials, but studies in a vast range of other fields including the geosciences and material sciences.Acknowledgments: Thankyou to ARES, JSC, NASA; JdLC Curtin University and Space Science Technology Centre for the use of laboratory facilities and funding [confirm].

Nicole D Nevill↗

Computer based imaging and analysis of root gravitropism

Two key issues in studies of the nature of the gravitropic response in roots have been the determination of the precise pattern of differential elongation responsible for downward bending and the identification of the cells that show the initial motor response. The main approach for examining patterns of differential growth during root gravitropic curvature has been to apply markers to the root surface and photograph the root at regular intervals during gravitropic curvature. Although these studies have provided valuable information on the characteristics of the gravitropic motor response in roots, their labor intensive nature limits sample size and discourages both high frequency of sampling and depth of analysis of surface expansion data. In this brief review we describe the development of computer-based video analysis systems for automated measurement of root growth and shape change and discuss some key features of the root gravitropic response that have been revealed using this methodology. We summarize the capabilities of several new pieces of software designed to measure growth and shape changes in graviresponding roots and describe recent progress in developing analysis systems for studying the small, but experimentally popular, primary roots of Arabidopsis. A key finding revealed by such studies is that the initial gravitropic response of roots of maize and Arabidopsis occurs in the distal elongation zone (DEZ) near the root apical meristem, not in the main elongation zone. Another finding is that the initiation of rapid elongation in the DEZ following gravistimulation appears to be related to rapid membrane potential changes in this region of the root. These observations have provided the incentive for ongoing studies examining possible links between potential growth modifying factors (auxin, calcium, protons) and gravistimulated changes in membrane potential and growth patterns in the DEZ.

NASA Discipline Plant Biology↗

GC/MS Method Development for Separating Lunar Volatile Ice Simulant Headspace Gases

Various investigators propose the lunar surface contains widely distributed volatiles, especially water- like species, i.e. OH and H2O. Surface volatiles are theorized to exist as a hydrated regolith layer, concentrated in extremely cold polar permanently shadowed regions (PSR), and/or solar wind implantation reservoirs in lunar glasses. The proposed sources of lunar surface volatiles range from cometary impacts, solar wind, or a supply present during moon formation. Future Artemis missions aim to collect and return the samples containing volatiles collected near lunar polar craters or PSRs. We, as advanced curation scientists, are responsible for developing techniques and methodologies for preserving returned sample integrity as much as possible. Pristine volatile-bearing samples are invaluable to the scientific community seeking to unravel the history of the solar system. Realistically, a sample will experience alteration during collection, transportation back to earth, and storage. The Planetary Exploration and Astromaterials Research Lab (PEARL) seeks to understand temperature and pressure effects on high-fidelity volatile-containing regolith simulants, the foundation for the future of cold curation. This abstract outlines the separation, identification, and quantification of headspace gases over volatile ice feed stock material using gas chromatography/mass spectrometry (GC/MS). Preliminary objectives concentrated on sample handling, reproducibility, and understanding the elution characteristics for each analyte. Initial GC/MS method development experiments utilized diluted static headspace sample preparation. Diluted samples were used because sampling headspace gases directly from a vial containing liquid analyte resulted in overloading of the column and detector. Overloading is evident based on chromatogram peak shapes and instrument contamination, or carry over, between experiments. A mixture of three alcohols were used for a majority of the sample handling and reproducibility studies. Reproducibility was tested via multiple users, calibration curves, and check standards. Stock solutions of condensed lunar volatile analytes included methanol, ammonia in methanol, hydrogen sulfide in water, and an equal volume mixture of methanol, ethanol, and isopropanol. Current samples use room air as the headspace sample matrix, however future experiments will incorporate an inert purge gas, such as argon or nitrogen. Three mL of each analyte solution were capped in separate 20 mL crimp top GC vials. Dilutions were carried out by removing an aliquot of headspace gases with a calibrated 1 mL gastight syringe and immediately transferring to a 20 mL capped crimp top vial. The GC/MS is a Thermo Fisher Trace 1310/ISQ 7000 with a TriPlus RSH autosampler and split/splitless injector module. The experiments outlined in this abstract use the following hardware: a 2.5 mL gastight headspace syringe tool, 1 mm ID x 78.5 mm length ultra-inert straight injection liner, and a TG-BondQ 30 m × 0.32 mm × 10 μm column. Various parameters, such as hardware selection and the temperature, pressure, and split ratio set points, continue to evolve as the overall experiment is refined. Diluted headspace chromatograms were collected for the individual stock solutions. Retention times, peak shapes, and mass spectra were evaluated and added to the data processing method for each molecule of interest. Figure 1 shows the total ion chromatograms for the three major lunar volatile simulant stock solutions: methanol, 7 N ammonia in methanol, and 0.4% hydrogen sulfide in water. Tailing peak shapes for ammonia (2.98 min rt) and water (4.06 min rt) indicate the molecules are not properly eluting from the selected column with the current separation method. Additionally, hydrogen sulfide and ammonia have overlapping peak windows, which could impact quantification. Ongoing experiments aim to address the peak shape and overlapping via the separation method and hardware selection. Sample preparation reproducibility experiments used stock solution containing equal volumes of a non- interactive mixture of methanol, ethanol, and isopropanol. Mass spectrum ion traces were used to identify and quantify all three alcohols. Peaks were automatically detected, identified, and integrated through the mass spectra detection and processing parameters. Calibration response curves and check standards were used to evaluate the validity of the sample preparation procedure. Figure 2 shows the methanol chromatogram peak area versus total headspace dilution volume transferred from the alcohol mixture vial. The calibration response curves and check standards validate sample preparation procedure. Continuing data analysis efforts are working towards correlating the peak area and instrument response factor to the headspace analyte concentration and condensed phase composition. Static headspace gas chromatography theory relies on Dalton’s law, Raoult’s law, Henry’s Law, and the Kolb and Ettre equation to associate peak area to the analyte composition in a non-ideal solution. Equation 1 is a simplified expression derived from the aforementioned theories. Future experiments involve liquid injections of the individual stock solutions, liquid and headspace analysis of various stock solution combinations, and the addition of regolith simulants to the mixtures. Temperature is another variable expected to affect reaction rates and will be explored.

Cecilia L. Amick↗

ATHENA detector proposal—a totally hermetic electron nucleus apparatus proposed for IP6 at the Electron-Ion Collider

ATHENA has been designed as a general purpose detector capable of delivering the full scientific scope of the Electron-Ion Collider. Careful technology choices provide fine tracking and momentum resolution, high performance electromagnetic and hadronic calorimetry, hadron identification over a wide kinematic range, and near-complete hermeticity. This article describes the detector design and its expected performance in the most relevant physics channels. It includes an evaluation of detector technology choices, the technical challenges to realizing the detector and the R&D required to meet those challenges.

47 OTHER INSTRUMENTATION↗

Evaluating Variable-Impedance Magnetically-Insulated Transmission Lines as a Risk-Mitigation Measure for Next-Generation Pulsed Power

This project has produced the first detailed characterizations of power flow resulting from applying the “variable-impedance MITL” concept to real-life systems in Sandia’s pulsed power program (Z and next-generation pulsed power (NGPP)). We present simulation results and analyses for constant-impedance versions of both Z and NGPP and survey the operational viability of several variable-impedance re-designs in the parameter space of linear tapers. Circuit modeling (SCREAMER/Bertha) was used to pinpoint promising candidate designs, and EM-PIC (Empire) simulations were used to evaluate these candidates more rigorously. This approach was particularly successful in the Z regime which resulted in the identification of several viable variable-impedance MITL designs for each level. The approach was more challenged in the operating space NGPP occupies, producing data points that speak to a more restrictive design space due to anode plasma turn-on. In the end, we were able to converge on one viable variable-impedance design for the highest inductance line (level “F”) and one for the highest current line (level “A”). Altogether, the body of simulation evidence presented in this report suggest there does exist flexibility in operating space for magnetically-insulated transmission lines (MITLs) having variable geometric impedance to be a potential enabling technology for safely increasing current delivery (and potentially lowering stack voltage) in pulsed-power drivers by manipulating electron losses; however, operating points for a particular design must be carefully screened. Circuit and EM-PIC modeling provided consistent verdicts in safe operating regimes for operational viability, but additional physics such as anode plasma turn-on which is included in Empire but not in SCREAMER/Bertha was found to be a critical factor affecting power flow that lead to different assessments between the codes. It is not always the case that the occurrence of anode plasma caused a design to fail (some designs turned on anode plasma yet still delivered load currents meeting design targets); the details matter such as how early in the pulse anode surfaces break down (and how large a region). However, in every case that it did fail it was found that the feedback from anode plasma was the cause (i.e., turning off the anode plasma model in Empire restored agreement with the circuit model prediction). As circuit simulations represent an efficient and practical means of surveying design space compared to more computationally-expensive approaches such as EM-PIC, it could be prudent to invest in the research and development of models to include the effects of anode plasma such as ion emission in circuit codes. The variable-impedance MITL design is a new concept that enables controlled manipulation of the initial electron losses in the outer MITL and can be tested on Z today. We encourage follow-on work to explore further optimization (including alternative variable-impedance profiles, e.g., having constant dZ/dR), and to confirm the major findings presented in this report by fielding test hardware on actual Z shots.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Lunar and Planetary Science XXXVI, Part 19

The topics include: 1) The abundances of Iron-60 in Pyroxene Chondrules from Unequilibrated Ordinary Chondrites; 2) LL-Ordinary Chondrite Impact on the Moon: Results from the 3.9 Ga Impact Melt at the Landing Site of Appolo 17; 3) Evaluation of Chemical Methods for Projectile Identification in Terrestrial and Lunar Impactites; 4) Impact Cratering Experiments in Microgravity Environment; 5) New Achondrites with High-Calcium Pyroxene and Its implication for Igneous Differentiation of Asteroids; 6) Climate History of the Polar Regions of Mars Deduced form Geologic Mapping Results; 7) The crater Production Function for Mars: A-2 Cumulative Power-Law Slope for Pristine Craters Greater than 5 km in Diameter Based on Crater Distribution for Northern Plains Materials; 8) High Resolution Al-26 Chronology: Resolved Time Interval Between Rim and Interior of a Highly Fractionated Compact Type a CAI from Efremovka; 9) Assessing Aqueous Alteration on Mars Using Global Distributions of K and Th; 10) FeNi Metal Grains in LaPaz Mare Basalt Meteorites and Appolo 12 Basalts; 11) Unique Properties of Lunar Soil for In Situ Resource Utilization on the Moon; 12) U-Pb Systematics of Phosphates in Nakhlites; 13) Measurements of Sound Speed in Granular Materials Simulated Regolith; 14) The Effects of Oxygen, Sulphur and Silicon on the Dihedral Angles Between Fe-rich Liquid Metal and Olivine, Ringwoodite and Silicate Perovskite: Implications for Planetary Core Formation; 15) Seismic Shaking Removal of Craters 0.2-0.5 km in Diameter on Asteroid 433 Eros; 16) Focused Ion Beam Microscoopy of ALH84001 Carbonate Disks; 17) Simulating Micro-Gravity in the Laboratory; 18) Mars Atmospheric Sample Return Instrument Development; 19) Combined Remote LIBS and Raman Spectroscopy Measurements; 20) Unusual Radar Backscatter Properties Along the Northern Rim of Imbrium Basin; 21) The Mars Express/NASAS Project at JPL; 22) The Geology of the Viking 2 Lander Site Revisited; 23) An Impact Genesis for Loki Patera? 24) Mars Polar Cap Edges Tracked over 3 Full Mars Years; 25) Elemental Abundance in Presolar SiC: Comparing Grains Separated by Acid Residue and Gently Separation Procedures; 26) First Results from the Descent Imager/Spectral Radiometer (DISR) Experiment on the Huygens Entry Probe of Titan; 27) Minor Element Behavior of Pallasite Olivine: Understanding Pallasite Thermal History and Chronology; 28) Canonical Anorthite in a Grosnaja Forsterite-bearing CAI; 29) Experimental Evidence for Condensation of 'Astrophysical' Carbonate; 30) Distribution and Classification of Multiple Coronae on Venus; 31) Recognition of Rayed Craters on Mars in THEMIS Thermal Infrared Imagery: Implications for Martian Meteorite Source Regions; 32) Geochemical Modeling of Evaporites on Mars: Insight from Meridiani Planum; 33) Hadean Crustal Processes Revealed from Oxygen Isotopes and U-Th-Pb Depth Profiling of Pre-4.0 Ga Detrital Zircons from Western Australia; 34) On Modeling the Seepage of Water into the Martian Subsurface; 35) Martial Gullies and Groundwater: A Series of Unfortunate Exceptions; 36) Olivine and Carbonate Globules in ALH84001: A Terrestrial Analog, and Implications for Water on Mars; 37) A Reevaluation of Mass Movements Within the Valles Marineris Region of Mars Using MOLA and MOC Data; 38) Evidence of Hydrated 109P/Swift-Tuttle Meteoroids from Meteor Spectroscopy; 39) Cr-54 Anomalies in the Solar System: Their Extent and Origin; 40) Reevaluation of the Mn-53-Cr-53 Systematic in the Basaltic Achondrites; 41) Effective Liquid Metal-Silicate Mixing Upon Shock by Power-Law Droplet Size Scaling in Richtmyer-Meshkov Like Perturbations; 42) Post-Impact Deformation of Impact Craters: Towards a Better Understanding Through the Study of Mjolnir Crater; 43) Cutting Silica Aerogel for Particle Extraction; 44) Liquid Hydrocarbons on Titan's Surface? How Cassini ISS Observations Fit into the Story (So Far); and 45) Mesoscale Simulations of Polar Circulations: Late Spring to Late Summe

Source record↗