Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “instrument transmissions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Fiber-Optic Gratings for Lidar Measurements of Water Vapor

Narrow-band filters in the form of phase-shifted Fabry-Perot Bragg gratings incorporated into optical fibers are being developed for differential-absorption lidar (DIAL) instruments used to measure concentrations of atmospheric water vapor. The basic idea is to measure the relative amounts of pulsed laser light scattered from the atmosphere at two nearly equal wavelengths, one of which coincides with an absorption spectral peak of water molecules and the other corresponding to no water vapor absorption. As part of the DIAL measurement process, the scattered light is made to pass through a filter on the way to a photodetector. Omitting other details of DIAL for the sake of brevity, what is required of the filter is to provide a stop band that: Surrounds the water-vapor spectral absorption peaks at a wavelength of 946 nm, Has a spectral width of at least a couple of nanometers, Contains a pass band preferably no wider than necessary to accommodate the 946.0003-nm-wavelength water vapor absorption peak [which has 8.47 pm full width at half maximum (FWHM)], and Contains another pass band at the slightly shorter wavelength of 945.9 nm, where there is scattering of light from aerosol particles but no absorption by water molecules. Whereas filters used heretofore in DIAL have had bandwidths of =300 pm, recent progress in the art of fiber-optic Bragg-grating filters has made it feasible to reduce bandwidths to less than or equal to 20 pm and thereby to reduce background noise. Another benefit of substituting fiber-optic Bragg-grating filters for those now in use would be significant reductions in the weights of DIAL instruments. Yet another advantage of fiber-optic Bragg-grating filters is that their transmission spectra can be shifted to longer wavelengths by heating or stretching: hence, it is envisioned that future DIAL instruments would contain devices for fine adjustment of transmission wavelengths through stretching or heating of fiber-optic Bragg-grating filters nominally designed and fabricated to have transmission wavelengths that, in the absence of stretching, would be slightly too short.

Vann, Leila B.↗

The Ulysses dust experiment

The Ulysses dust experiment is intended to provide direct observations of dust grains with masses between 10 exp -16 g and 10 exp -6 g in interplanetary space, to investigate their physical and dynamical properties as functions of heliocentric distance and ecliptic latitude. Of special interest is the question of what portion is provided by comets, asteroids, and interstellar particles. The investigation is performed with an instrument that measures the mass, speed, flight direction, and electric charge of individual dust particles. It is a multicoincidence detector with a mass sensitivity 10 exp 6 times higher than that of previous in situ experiments which measured dust in the outer solar system. The instrument weighs 3.8 kg, consumes 2.2 W, and has a normal data transmission rate of 8 bits/s in nominal spacecraft tracking mode. On 27 October 1990 the instrument was switched-on. The instrument was configured to flight conditions and science data collection started immediately. In the period to 13 January 1991, at least 44 dust impacts have been recorded. Flux values are given covering the heliocentric distance range from 1.04 to 1.7 AU.

Gruen, E.↗

The Galileo Dust Detector

The Galileo Dust Detector is intended to provide direct observations of dust grains with masses between 10 exp -19 and 10 exp -9 kg in interplanetary space and in the Jovian system, to investigate their physical and dynamical properties as functions of the distances to the sun, to Jupiter and to its satellites, and to study its interaction with the Galilean satellites and the Jovian magnetosphere. The investigation is performed with an instrument that measures the mass, speed, flight direction and electric charge of individual dust particles. It is a multicoincidence detector with a mass sensitivity 1 000 000 times higher than that of previous in situ experiments which measured dust in the outer solar system. The instrument weighs 4.2 kg, consumes 2.4 W, and has a normal data transmission rate of 24 bits/s in nominal spacecraft tracking mode. On December 29, 1989 the instrument was switched-on. After the instrument had been configured to flight conditions cruise science data collection started immediately. In the period to May 18, 1990 at least 168 dust impacts have been recorded. For 81 of these dust grains masses and impact speeds have been determined. First flux values are given.

Gruen, Eberhard↗

The Ulysses dust experiment

The Ulysses dust experiment is intended to provide direct observations of dust grains with masses between 10(exp -16) g and 10(exp -6) g in interplanetary space, to investigate their physical and dynamical properties as functions of heliocentric distance and ecliptic latitude. Of special interest is the question of what portion is provided by comets, asteroids and interstellar particles. The investigation is performed with an instrument that measures the mass, speed, flight direction, and electric charge of individual dust particles. It is a multicoincidence detector with a mass sensitivity 10(exp 6) times higher than that of previous in-situ experiments which measured dust in the outer solar system. The instrument weighs 3.8 kg, consumes 2.2 W, and has a normal data transmission rate of 8 bits/s in nominal spacecraft tracking mode. On 27 Oct. 1990 the instrument was switched on. The instrument was configured to flight conditions, and science data collection started immediately. At least 44 dust impacts had been recorded by 13 Jan. 1991. Flux values are given covering the heliocentric distance range from 1.04 to 1.7 AU.

Gruen, E.↗

The Galileo dust detector

The Galileo Dust Detector is intended to provide direct observations of dust grains with masses between 10(sup -19) kg and 10(sup -9) kg in interplanetary space and in the Jovian system, to investigate their physical and dynamical properties as functions of the distances to the Sun, to Jupiter and to its satellites, to study its interaction with the Galilean satellites and the Jovian magnetosphere. Surface phenomena of the satellites (like albedo variations), which might be effects of meteoroid impacts will be compared with the dust environment. Electric charges of particulate matter in the magnetosphere and its consequences will be studied; e.g. the effects of the magnetic field on the trajectories of dust particles and fragmentation of particles due to electrostatic disruption. The investigation is performed with an instrument that measures the mass, speed, flight direction and electric charge of individual dust particles. It is a multi-coincidence detector with a mass sensitivity 10(sup 6) times higher than that of previous in-situ experiments which measured dust in the outer solar system. The instrument weighs 4.2 kg, consumes 2.4 W, and has a normal data transmission rate of 24 bits/s in nominal spacecraft tracking mode. On December 29, 1989 the instrument was switched-on. After the instrument had been configured to flight conditions cruise science data collection started immediately. In the period to May 18, 1990 at least 168 dust impacts have been recorded. For 81 of these dust grains, masses and impact speeds have been determined. First flux values are also given.

Gruen, E.↗

In-Situ XRD/XRF to Support Life Detection on Mars

X-ray diffraction / X-ray fluorescence (XRD/XRF) analysis provides the most comprehensive mineralogical / compositional characterization of rocks and soils of any flight-capable technique. XRD data provide quantitative mineralogy (including abundance of X-ray amorphous materials) and crystal chemistry (structure, elemental composition and valence state), and XRF data provide complimentary major, minor, and some trace element abundances. Both types of data are important in evaluating habitability (environment of formation) and biosignature preservation/degradation (post-depositional diagenetic change). Whether or not a relict biosignature is detected, the mineral assemblage and its geochemistry can be used to determine the habitability of an ancient environment (e.g., salinity, pH, temperature), and to identify potential sources of energy for life (e.g., elements in different redox states). In this respect, a null result (a habitable environment lacking evidence of life) can play an important role in constraining the parameters of the search. Conversely, diagenetic alteration (taphonomic change) resulting from post-depositional variations in temperature, pressure or fluid chemistry can preserve evidence of biogenicity, erase such evidence completely or indeed can provide for post-depositional habitable conditions in the subsurface. XRD / XRF data are critical to these determinations. The CheMin instrument on the Mars Science Laboratory (MSL) Curiosity rover is the first XRD instrument flown in space. CheMin operates in transmission geometry with a Co X-ray source to minimize fluorescence from iron. Diffracted photons are collected with an energy-sensitive charge-coupled device (CCD). The position of the diffracted photons provides structural information for minerals, whereas the energy of sample-generated X-ray fluorescence photons provides elemental information, though these XRF data are qualitative. Mineralogical data from the CheMin XRD identified the three circumstances above: habitable depositional environments (e.g., Yellowknife Bay), habitable subsurface/diagenetic environments (e.g., throughout the Murray formation), and diagenetic conditions that may destroy evidence of habitability (e.g., oxidative and acidic environments at Vera Rubin ridge). Technological advances in X-ray technology and lessons learned from the operation of CheMin on Mars have resulted in a next-generation XRD/XRF, called CheMinX. Replacement of CheMin’s CCD with an array of hybrid pixel detectors and improvements in focusing optics dramatically decrease analysis time (15 minutes vs. 22 hours for MSL-CheMin) and result in a better angular resolution (0.18 vs. 0.30 °2θ for MSL-CheMin). This increased resolution improves mineral detection, including discrimination between types of pyroxenes, which is not possible with MSL-CheMin data. The hybrid pixel detectors do not require cooling like the MSL-CheMin CCD, therefore reducing the power needed to operate CheMinX. CheMinX has a silicon-drift detector (SDD) to measure fluoresced photons, enabling the quantification of major, minor, and some trace elements via XRF. XRD/XRF data are collected simultaneously in CheMinX, obviating the need for multiple compositional instruments. The CheMinX design also improves upon MSL-CheMin’s sample handling. Instead of sample cells on wheel, which are often not reusable and add complexity in commanding the instrument, CheMinX has single-use cells in a cartridge/dispenser configuration. Because of these improvements, CheMinX is an ideal instrument for Discovery-class life-detection missions, including Mars Life Explorer that was recommended for development in the Planetary Science and Astrobiology Decadal Survey 2023-2032.

E B Rampe↗

A library of calcium mineral reference spectra recorded by parallel imaging using NEXAFS spectromicroscopy

Calcium minerals are ubiquitous in geology and life chemistry. Understanding the phase and chemical state of calcium minerals is important for numerous processes including materials chemistry, hard tissue biogenesis and geological processes. Photoemission spectroscopies such as near edge X-ray absorption fine structure (NEXAFS) and scanning transmission X-ray microscopy have been instrumental in identifying and characterizing calcium minerals in all these areas. In this work, we have recorded reference spectra for a range of different calcium minerals including a series of calcium carbonates, calcium oxalates and calcium phosphates. While collections of reference spectra for several calcium minerals can be found in the literature, these spectra have been reported in different contexts using a variety of instruments. We, here, report a comprehensive list of references recorded in parallel in a single experiment by imaging an array of calcium minerals using a NEXAFS microscope. We present reference NEXAFS spectra at the calcium L-, carbon K- and oxygen K-edges.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Pioneer Venus encounter will occur in December

The encounter time line and mission profile are presented for the Pioneer Venus 1 Spacecraft and for the four probes and transponder bus that comprise Pioneer Venus 2. Known facts about Venus are reviewed and the history of discoveries about the planet is related. Operations of the orbiter and multiprobe are described as well as the 30 instruments being carried and provisions for data transmission.

Source record↗

Quantitative analysis of hard X-ray 'footpoint' flares observed by the solar maximum mission

Amplifier gain and collimator hole size variations across the field of view, amplifier/filter efficiency, variations in effective collimator hole size and angular response with photon energy, dead-time, and hard X-ray plate transmission, are among the factors for which instrumental corrections have to be incorporated to effect reliable correction and deconvolution of images from the SMM satellite's Hard X-ray Imaging Spectrometer (HXIS). Attention is given to the substantial Poisson noise in these energy bands. The maximum entropy deconvolution/correction routine developed for establishing the spatial structure reliably inferrable from HXIS data is presented, together with the results of the application of this routine to the three impulsive flares reported by Duijemian et al. (1982) from April 10, May 21, and November 5, 1980.

Mackinnon, A. L.↗

Measurement of polycyclic aromatic hydrocarbon (PAHs) in interplanetary dust particles

We report here the first definitive measurements of specific organic molecules (polycyclic aromatic hydrocarbons (PAH's)) in interplanetary dust particles (IDP's). An improved version of the microbeam-two-step laser mass spectrometer was used for the analysis. Two IDP's gave similar mass spectra showing an abundance of PAH's. Control samples, including particles of probable terrestrial origin from the same stratospheric collector, gave either null results or quite different spectra. We conclude that the PAH's are probably indigenous to the IDP's and are not terrestrial contaminants. The instrument used to study the particles is a two-step laser mass spectrometer. Constituent neutral molecules of the sample are first desorbed with a pulsed infrared laser beam focussed to 40 micrometers. In the second step, PAH's in the desorbed plume are preferentially ionized by a pulsed UV laser beam. Resulting ions produced by resonant absorption are extracted into a reflectron time-of-flight mass spectrometer. This instrument has high spatial resolution, high ion transmission, unlimited mass range, and multichannel detection of all ion masses from a single laser shot.

Clemett, S. J.↗

Multi-band automatic sun and sky scanning radiometer system for measurement of aerosols

A weather resistant automatic scanning Sun photometer system is assessed and demonstrated as practical for measurements of aerosol concentrations and properties at remote sites. Interfaced with a transmitter using the Geostationary Data Collection System (GDCS), the data are processed in near real time. The processing allows a time dependence of the aerosols and water vapor and an ongoing assessment of the health and calibration of the instruments. The system's automatic data acquisition, transmission, and processing offer immediate application to atmospheric monitoring and modeling on a regional to global scale and validation of satellite retrievals. It is estimated that under normal circumstances the retrieved aerosol optical thickness has a network wide accuracy of +/- 0.02 from 340 nm to 1020 nm, water vapor +/- 0.2 cm and size distribution from 0.1 to 3 micrometers.

Holben, B. N.↗

Spectral decomposition of AVIRIS data

A set of techniques is presented that uses only information contained within a raw Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) scene to estimate and to remove additive components such as multiple scattering and instrument dark current. Multiplicative components (instrument gain, topographic modulation of brightness, atmospheric transmission) can then be normalized, permitting enhancement, extraction, and identification of relative reflectance information related to surface composition and mineralogy. The technique for derivation of additive-component spectra from a raw AVIRIS scene is an adaption of the 'regression intersection method' of Crippen. This method uses two surface units that are spatially extensive, and located in rugged terrain. For a given wavelength pair, subtraction of the derived additive component from individual band values will remove topography in both regions in a band/band ratio image. Normalization of all spectra in the scene to the average scene spectrum then results in cancellation of multiplicative components and production of a relative-reflectance scene. The resulting AVIRIS product contains relative-reflectance features due to mineral absorption that depart from the average spectrum. These features commonly are extremely weak and difficult to recognize, but they can be enhanced by using two simple 3-D image-processing tools. The validity of these techniques will be demonstrated by comparisons between relative-reflectance AVIRIS spectra and those derived by using JPL standard calibrations. The AVIRIS data used in this analysis were acquired over the Kelso Dunes area (34 deg 55' N, 115 deg 43' W) of the eastern Mojave Desert, CA (in 1987) and the Upheaval Dome area (38 deg 27' N, 109 deg 55' W) of the Canyonlands National Park, UT (in 1991).

Gaddis, Lisa↗

Photon-Counting Multikilohertz Microlaser Altimeters

Spaceborne laser altimeters in planetary orbit typically use high energy (approximately 100 mJ) solid state lasers, large telescopes (50 to 100 cm), and high detection thresholds to achieve unambiguous surface returns with few or no ifalse alarmsi resulting from solar background noise. As a result of this conservative design philosophy, spacecraft prime power weight, or size constraints typically restrict operations to modest repetition rates on the order of a few tens of Hz which, at a typical ground velocity of 7 Km/sec, limits along-track spatial sampling to one sample every few hundred meters. The surface return rate of an Earth-orbiting altimeter can be increased by up to two orders of magnitude for a given laser output power by emitting the available photons in a high frequency (few KHz) train of low energy (< 1 mJ) pulses, as produced by passively Q-switched solid state "microlasers", and using single photon detection. while simultaneously using much smaller telescope diameters on the order of 10 cm. Simple onboard software algorithms, based on post-detection Poisson filtering techniques, can be employed to identify and extract the surface data from solar background noise prior to onboard data storage or transmission to a ground station. Under NASAis Instrument Incubator Program, we have begun the design and construction of a scanning airborne instrument to demonstrate the potential advantages of the technique for future space missions.

Degnan, John J.↗

Pigmenting agents in Martian soils: inferences from spectral, Mossbauer, and magnetic properties of nanophase and other iron oxides in Hawaiian palagonitic soil PN-9

We have examined a Hawaiian palagonitic tephra sample (PN-9) that has spectroscopic similarities to Martian bright regions using a number of analytical techniques, including Mossbauer and reflectance spectroscopy, X-ray diffraction, instrumental neutron activation analysis, electron probe microanalysis, transmission electron microscopy, and dithionite-citrate-bicarbonate extraction. Chemically, PN-9 has a Hawaiitic composition with alkali (and presumably silica) loss resulting from leaching by meteoric water during palagonitization; no Ce anomaly is present in the REE pattern. Mineralogically, our results show that nanophase ferric oxide (np-Ox) particles (either nanophase hematite (np-Hm) or a mixture of ferrihydrite and np-Hm) are responsible for the distinctive ferric doublet and visible-wavelength ferric absorption edge observed in Mossbauer and reflectivity spectra, respectively, for this and other spectrally similar palagonitic samples. The np-Ox particles appear to be imbedded in a hydrated aluminosilicate matrix material; no evidence was found for phyllosilicates. Other iron-bearing phases observed are titanomagnetite, which accounts for the magnetic nature of the sample; olivine; pyroxene; and glass. By analogy, np-Ox is likely the primary pigmenting agent of the bright soils and dust of Mars.

Minerals/analysis↗

Analysis of Observed Contamination Through SAGE III's First Year on Orbit

SAGE III is a payload on the International Space Station that conducts measurements of ozone and other atmospheric constituents through the use of a moderate resolution spectrometer with an operating wavelength range of 290 nm to 1550 nm. Because of the optically sensitive nature of the payload, a suite of eight Thermoelectric Quartz Crystal Microbalances (TQCMs) were included to monitor the operating environment. During the rst year of operation, the SAGE III TQCMs were instrumental in detecting several periods of higher contamination and localizing their sources. A clear window made from quartz crystal covers the instrument assembly's aperture. Under nominal operating conditions, this window is only open during science gathering activities. However, if the rates of contamination accumulation are detected to be above the background rate, the window will be kept closed during science gathering to protect the optically sensitive instrument mirror. An analysis of the signal transmissions through the window for the wavelengths of 290 nm to 1550 nm has been conducted to determine any possible degradation of the window and potential in uence on science data collected to date, and established a baseline for future analysis.

Thompson, Michael P.↗

A flexible CAMAC based data system for Space Shuttle scientific instruments

An effort has been made within NASA to produce a low-cost modular system for implementation of Shuttle payloads based on the CAMAC standards for packaging and data transfer. A key element of such a modular system is a means for controlling the data system, collecting and processing the data for transmission to the ground, and issuing commands to the instrument either from the ground or based on the data collected. A description is presented of such a means based on a network of digital processors and CAMAC crate controllers, which allows for the implementation of instruments ranging from those requiring only a single CAMAC crate of functional modules and no data processing to ones requiring multiple crates and multiple data processors.

Ehrmann, C. H.↗

Port Impedance Measurement and Current Injection Response Analysis for PLCs

Programmable Logic Controllers (PLCs) are used to control devices throughout the power system since they have fast control capabilities and can utilize multiple types of communication interfaces. Therefore, studying and mitigating their vulnerabilities to electromagnetic pulse is important for the reliability of PLC operations. Here, in this paper, an effective impedance measurement scheme is proposed and demonstrated for three PLCs to estimate their susceptibility to an electromagnetic pulse. The equivalent non-uniform transmission line model is established to eliminate the impact of the fixture in the de-embedding process. Then different parameters of the impedance measurement setup are explored. Based on the measured impedance, the equivalent circuit is established to calculate the response of the device when subjected to the electromagnetic pulse. The voltage and current responses of different interfaces are compared utilizing the developed pulsed Current Injection (CI) method. Finally, the impedance measurement scheme is verified through testing using three measuring instruments. And the CI simulation experiments reveal the characteristics and susceptibilities of different PLCs interfaces, indicating that some protection measures are required for the reliable operation of the PLC.

42 ENGINEERING↗