Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “infrared light”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Real-Time Keratometer

Optical/electronic keratometer system produces contour map of corneal surface illuminated by infrared light pulses. Prevents operator error and eliminates need to apply fluorescent liquids to cornea. Keratometer provides both video display and numerical recording for corneal-transplant and radial-keratotomy surgery and for contact-lens fitting. Optical system of keratometer, circular grating pattern transmitted to corneal surface reflected onto identical circular grating on surface of fiber plate, producing Moire pattern. Data-analysis-and-display mode, laser light pulsed, and Moire pattern converted to digital information in frame grabber. Digital picture information sent to computer for processing and display.

Frazer, Robert E.↗

Small, Optically-Driven Power Source

Power transmitted along fiber-optic cables. Transmitted as infrared light along fiber-optic cable, converted to electricity to supply small electronic circuit. Power source and circuit remains electrically isolated from each other for safety or reduces electromagnetic interference. Array of diodes made by standard integrated-circuit techniques and packaged for mounting at end of fiber-optic cable.

Cockrum, Richard H.↗

Closed-Loop Motor-Speed Control

Electronic motor-speed control circuit designed to operate in electrically noisy environment. Includes optoelectronic pick-up device, placed inside motor housing to provide speed feedback signal. Automatically maintains speed motor at commanded value. Measures speed of motor in terms of frequency of pulses of infrared light chopped by fan blades of motor. Difference between measured and commanded speeds serves as control signal for external amplifier driving motor. Major advantage of circuit is low cost.

Smith, Matthew A.↗

Monitoring Small Deformations In An Instrument

Relatively simple source/detector pairs measure changes affecting optical alignment. System for monitoring small thermal, gravitational, and dynamical deformations in x-ray telescope includes two sources of infrared light, each associated with dual-axis, position-sensing photodiode. Principle of operation straightforward and applicable to monitoring of small lateral translations and/or rotations between different parts in machinery, buildings, bridges, ships, and other large structures.

Hagopian, John G.↗

Filters for soft X-ray solar telescopes

Soft X-ray telescopes require filters that block visible and infrared light and have good soft X-ray transmission. The optical properties of possible materials are discussed, and the fabrication and testing methods for the filters used in a 10-inch normal incidence telescope for 63 A are described. The best performances in the 44-114-A wavelength range are obtained with foils of carbon and rhodium.

Spiller, Eberhard↗

Photovoltaic quantum well infrared photodetectors

Quantum well infrared photodetectors (QWIP) are a promising new approach to long-wavelength infrared detector arrays. Both single-well photovoltaic and multiple-well photoconductive devices have been demonstrated. The author discusses noise considerations as they apply to photovoltaic devices, grating coupling of the infrared light into QWIPs, and recently demonstrated electrically tunable detectors. The use of light trapping to enhance the quantum efficiency and reduce cross-talk in an array is addressed.

Lyon, Steve A.↗

Lunar transit telescope lander design

The Program Development group at NASA's Marshall Space Flight Center has been involved in studying the feasibility of placing a 16 meter telescope on the lunar surface to scan the skies using visible/ Ultraviolet/ Infrared light frequencies. The precursor telescope is now called the TRANSIT LUNAR TELESCOPE (LTT). The Program Development Group at Marshall Space Flight Center has been given the task of developing the basic concepts and providing a feasibility study on building such a telescope. The telescope should be simple with minimum weight and volume to fit into one of the available launch vehicles. The preliminary launch date is set for 2005. A study was done to determine the launch vehicle to be used to deliver the telescope to the lunar surface. The TITAN IV/Centaur system was chosen. The engineering challenge was to design the largest possible telescope to fit into the TITAN IV/Centaur launch system. The telescope will be comprised of the primary, secondary and tertiary mirrors and their supporting system in addition to the lander that will land the telescope on the lunar surface and will also serve as the telescope's base. The lunar lander should be designed integrally with the telescope in order to minimize its weight, thus allowing more weight for the telescope and its support components. The objective of this study were to design a lander that meets all the constraints of the launching system. The basic constraints of the TITAN IV/Centaur system are given.

Omar, Husam A.↗

Open-path tunable diode laser absorption for eddy correlation flux measurements of atmospheric trace gases

Biogenic emissions from and dry deposition to terrestrial surfaces are important processes determining the trace gas composition of the atmosphere. An instrument has been developed for flux measurements of gases such as CH4, N2O, and O3 based on the eddy correlation technique which combines trace gas fluctuation measurements with simultaneous windfield measurements. The instrument combines a tunable diode laser infrared light source with an open-path multipass absorption cell in order to provide the fast time response and short base pathlength required for the eddy correlation method. Initial field tests using the instrument to measure methane emissions from a local wetland demonstrate the capability for high precision eddy correlation flux measurements.

Anderson, Stuart M.↗

Tracking Polymer Cure Via Embedded Optical Fibers

Fourier-transform infrared spectroscopy applied in interior of specimen of material by bringing infrared light through specimen in optical fiber. Light interacts with material via evanescent-wave effect. Spectra obtained in this way at various times during curing process also combined with data from ultrasonic, thermographic, and dielectric-impedance monitoring, and other measurement techniques to obtain more complete characterization of progress of curing process.

Dean, David L.↗

Lunar transit telescope lander design

The Program Development group at NASA's Marshall Space Flight Center has been involved in studying the feasibility of placing a 16 meter telescope on the lunar surface to scan the skies using visible/ Ultraviolet/ Infrared light frequencies. The precursor telescope is now called the TRANSIT LUNAR TELESCOPE (LTT). The Program Development Group at Marshall Space Flight Center has been given the task of developing the basic concepts and providing a feasibility study on building such a telescope. The telescope should be simple with minimum weight and volume to fit into one of the available launch vehicles. The preliminary launch date is set for 2005. A study was done to determine the launch vehicle to be used to deliver the telescope to the lunar surface. The TITAN IV/Centaur system was chosen. The engineering challenge was to design the largest possible telescope to fit into the TITAN IV/Centaur launch system. The telescope will be comprised of the primary, secondary and tertiary mirrors and their supporting system in addition to the lander that will land the telescope on the lunar surface and will also serve as the telescope's base. The lunar lander should be designed integrally with the telescope in order to minimize its weight, thus allowing more weight for the telescope and its support components. The objective of this study were to design a lander that meets all the constraints of the launching system. The basic constraints of the TITAN IV/Centaur system are given.

Omar, Husam A.↗

Detecting Leaks With An Infrared Camera

Proposed test reveals small leak in gas pipe - for example, leak through fatigue crack induced by vibration - even though insulation covers pipe. Infrared-sensitive video camera aimed at part(s) containing suspected leak(s). Insulated pipe pressurized with gas that absorbs infrared light. If crack were present, escaping gas travels along outside of pipe until it reached edge of insulation. Gas emerging from edge of insulation appears as dark cloud in video image.

Easter, Barry P.↗

Thin Semiconductor/Metal Films For Infrared Devices

Spectral responses of absorbers and reflectors tailored. Thin cermet films composites of metals and semiconductors undergoing development for use as broadband infrared reflectors and absorbers. Development extends concepts of semiconductor and dielectric films used as interference filters for infrared light and visible light. Composite films offer advantages over semiconductor films. Addition of metal particles contributes additional thermal conductivity, reducing thermal gradients and associated thermal stresses, with resultant enhancements of thermal stability. Because values of n in composite films made large, same optical effects achieved with lesser thicknesses. By decreasing thicknesses of films, one not only decreases weights but also contributes further to reductions of thermal stresses.

Lamb, James L.↗

Wireless Infrared Data Link

Infrared transmitter and receiver designed for wireless transmission of information on measured physical quantity (for example, temperature) from transducer device to remote-acquisition system. In transmitter, output of transducer amplified and shifted with respect to bias or reference level, then fed to voltage-to-frequency converter to control frequency of repetition of current pulses applied to infrared-light-emitting diode. In receiver, frequency of repetition of pulses converted back into voltage indicative of temperature or other measured quantity. Potential applications include logging data while drilling for oil, transmitting measurements from rotors in machines without using slip rings, remote monitoring of temperatures and pressures in hazardous locations, and remote continuous monitoring of temperatures and blood pressures in medical patients, who thus remain mobile.

Roth, Timothy E.↗

Measuring Thicknesses Of Vacuum-Deposited Organic Thin Films

Method of measuring thickness of thin organic liquid film deposited in vacuum involves use of quartz-crystal monitor (QCM) calibrated by use of witness plate that has, in turn, calibrated by measurement of absorption of infrared light in deposited material. Present procedure somewhat tedious, but once calibration accomplished, thicknesses of organic liquid deposits monitored in real time and in situ by use of QCM.

David, Carey E.↗

Optical Sensors for Use in Propulsion Control Systems

This final technical report describes the results of a cooperative effort which was originally established between John Carroll University and the Instrumentation and Control Technology Division at NASA Lewis Research Center on November, 1982, and then continued with the Engine Sensor Technology Branch at NASA Lewis until March, 1995. All work at John Carroll University was directed by the principal investigator of this grant, Klaus Fritsch, Ph.D. For the first two years of this grant this effort was supervised at NASA by Mr. Robert J. Baumbick and for the remainder of the grant by Dr. Glenn M. Beheim. All research was carried out in close cooperation with Dr. Beheim. Electrically passive optical sensors for measurands such as pressure, temperature, position, and rotational speed are required for aircraft engine control in fly-by-light digital aircraft control systems. Fiberoptic data links and optical multiplexing techniques should be used for combining and processing the outputs from several sensors, sharing as many optical end electronic parts as possible. The overall objective of this grant was to explore techniques for designing and constructing such electrically passive optical sensors for measuring physical parameters in jet aircraft engines and for use in aircraft control systems. We have concentrated our efforts on pressure, temperature, and position sensors employing techniques which are relatively immune to transmissivity variations of the fiber links and to variations in intensity of the light source. Infrared light-emitting diodes are employed because of their longevity and immunity to vibration. We have also studied a number of multiplexing techniques. On the following pages I will give thumbnail sketches of the projects carried out under this grant and provide references to publications and John Carroll M.S. theses which resulted directly from this work and which describe these projects in greater detail.

Fritsch, Klaus↗

Strehl Ratio Meter for Focusing Segmented Mirrors 1

Initial focusing segmented mirrors that must be deployed in space, such as the Next Generation Space Telescope (NGST), provide challenges not faced before in the area of adaptive optics. The devices used to focus the mirror must minimize the power used and unnecessary mechanical movement. The device described in this report requires no movable parts except for the essential actuators required to move the mirror segments. Detail description of the components can be found in Coker, 1996. The primary mirror of the NGST will consist of 9 segments, a central annular segment, surrounded by 8 segments. The entire mirror assembly will be an 8 meter nearly filled circle (with the corners of the segments clipped to allow for storage in an Atlas IIe shroud). As the segments of the primary mirror are deployed to their operational positions, they must be positioned to within small fractions of a wavelength of near infrared light. When focused, the NGST will put most of its collected li-ht into the small region near the center of its focal plane. The ratio of the total light in the diffraction limited spot about the center of the focal plane to the total light in the focal plane. The purpose of this research effort is to design and build a device that will measure Strehl ratio and to use demonstrate that the Strehl ratio can be used to focus a segmented mirror.

Olivier, Philip D.↗

Comparative Soot Diagnostics Experiment Looks at the Smoky World of Microgravity Combustion

From an economic standpoint, soot is one of the most important combustion intermediates and products. It is a major industrial product and is the dominant medium for radiant heat transport in most flames used to generate heat and power. The nonbuoyant structure of most flames of practical interest (turbulent flames) makes the understanding of soot processes in microgravity flames important to our ability to predict fire behavior on Earth. In addition, fires in spacecraft are considered a credible possibility. To respond to this risk, NASA has flown fire (or smoke) detectors on Skylab and the space shuttles and included them in the International Space Station design. The design of these detectors, however, was based entirely on normal gravity (1g) data. The detector used in the shuttle fleet is an ionization detector, whereas the system planned for the space station uses forward scattering of near-infrared light. The ionization detector, which is similar to smoke detectors used in homes, has a comparative advantage for submicron particulates. In fact, the space shuttle model uses a separation system that makes it blind to particles larger than a micron (believed to be dust). In the larger size range, the lightscattering detector is most sensitive. Without microgravity smoke data, the difference in the particle size sensitivities of the two detectors cannot be evaluated. As part of the Comparative Soot Diagnostics (CSD) experiment, these systems were tested to determine their response to particulates generated during long periods of low gravity. This experiment provided the first such measurements toward understanding soot processes on Earth and for designing and implementing improved spacecraft smoke detection systems. The objectives of CSD were to examine how particulates form from a variety of sources and to quantify the performance of several diagnostic techniques. The sources tested included four overheated materials (paper, silicone rubber, Teflon-coated (DuPont) wire, and Kapton-coated (DuPont) wires), each tested at three heating rates, and a candle tested at three air velocities. Paper, silicone rubber, and wire insulation, materials found in spacecraft crew cabins, were selected because of their different smoke properties. The candle yielded hydrocarbon soot typical of many 1g flames. Four diagnostic techniques were employed: thermophoretic sampling collected particulates for size analysis; laser light extinction measurements near the source tallied total particulate production; and laser light scattering and ionization detector measurements far from the particulate source provided data for evaluating the performance of smoke detection systems for these particulate sources.

Urban, David L.↗

X-Ray Spectroscopy of Optically Bright Planets using the Chandra Observatory

Since its launch in July 1999, Chandra's Advanced CCD Imaging Spectrometer (ACIS) has observed several planets (Venus, Mars, Jupiter and Saturn) and 6 comets. At 0.5 arc-second spatial resolution, ACIS detects individual x-ray photons with good quantum efficiency (25% at 0.6 KeV) and energy resolution (20% FWHM at 0.6 KeV). However, the ACIS CCDs are also sensitive to optical and near-infrared light, which is absorbed by optical blocking filters (OBFs) that eliminate optical contamination from all but the brightest extended sources, e.g., planets. .Jupiter at opposition subseconds approx.45 arc-seconds (90 CCD pixels.) Since Chandra is incapable of tracking a moving target, the planet takes 10 - 20 kiloseconds to move across the most sensitive ACIS CCD, after which the observatory must be re-pointed. Meanwhile, the OBF covering that CCD adds an opt,ical signal equivalent to approx.110 eV to each pixel that lies within thc outline of the Jovian disk. This has three consequences: (1) the observatory must be pointed away from Jupiter while CCD bias maps are constructed; (2) most x-rays from within the optical image will be misidentified as charged-particle background and ignored; and (3) those x-rays that are reported will bc assigned anomalously high energies. The same also applies to thc other planets, but is less serious since they are either dimmer at optical wavelengths, or they show less apparent motion across the sky, permitting reduced CCD exposure times: the optical contamination from Saturn acids approx.15 eV per pixel, and from Mars and Venus approx.31 eV. After analyzing a series of short .Jupiter observations in December 2000, ACIS parameters were optimized for the February 2003 opposition. CCD bias maps were constructed while Chandra pointed away from Jupiter, and the subsequent observations employed on-board software to ignore any pixel that contained less charge than that expected from optical leakage. In addition, ACIS was commanded to report 5 x 5 arrays of pixel values surrounding each x-ray event, and the outlying values were employed during ground processing to correct for the optical contamination.

Ford, P. G.↗