158 records · Page 9

DC-Saturated Continuously Variable Series Reactors (CVSRs) for Power Flow Control in Power Transmission Systems

This paper proposes a novel continuously variable series reactor (CVSR) based on a dc current controller (DCC) to manage power flow in transmission systems. There are three major contributions. First, the three-dimensional electromagnetic interaction has been comprehensively analyzed to extend the understanding beyond the conventional 2D relationship. Second, a high-fidelity reluctance model of the CVSR with an improved DCC model is proposed and implemented. To overcome the fundamental concern for the system modeling, the DCC has been modeled as an ideal current source in parallel with an output impedance. Additionally, the induced back-EMF can be precisely projected which provides critical design guidelines for the DCC. Third, inspired by the theoretical analysis and modeling, a reliable high power DCC converter is designed accordingly to interface with kV-level back-EMF and supply kA-level dc current for a 115 kV/1500 A CVSR. Experiments are conducted in a practical transmission demonstration system. When the ac current in the transmission system varies from zero to 1500 A, experimental results show that the proposed CVSR can continuously regulate the reactance from 1.6 Ω to 5 Ω, validating the effectiveness of the proposed system design and modeling methodology.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Laminated Permanent Magnets Enable Compact Magnetic Components in Current Source Converters

Magnetic components play a key role in determining the size, cost, efficiency of a power converter. They are more significant in current source converters, where the dc-link energy is stored in an inductor/transformer. In such cases, the magnetics have a predominantly DC flux, superimposed by an AC flux at switching frequency. Previously, permanent magnets have been proposed to offset the DC flux and thereby reduce the size, cost, and losses of the inductors/transformers. This paper starts by analyzing the issue of eddy currents when using such standard permanent magnets, especially in medium frequency applications, making them practically unusable. Alternatively, the paper proposes the use of laminated permanent magnets to reduce these eddy currents and thereby realize the benefits of offsetting the DC flux to reduce the size, cost, and loss of inductors/transformers. Using a soft-switching solid-state transformer as an example, experimental results are presented to show the impact of eddy currents in standard permanent magnets when used with a medium frequency transformer. Here, experimental results showing the benefits of using laminated magnets in reducing the eddy currents are presented.

30 DIRECT ENERGY CONVERSION↗

Analytic Thermal Model of an Optical Fiber Based Gamma Thermometer and its Application in a University Research Reactor

This paper describes and validates, by comparison with numerical modeling results, an analytical model of thermal transport in an optical fiber based gamma thermometer (OFBGT) that is appropriate for use in university research reactors. The maximum temperature difference between the thermal mass and the outer sheath ( &#x0394;<!-- Δ --> T ) for the OFBGT design that we have considered is approximately 50 &#x2218;<!-- ° --> C , for the OFBGT in the Central Irradiation Facility of the Ohio State University Research Reactor (OSURR) with the reactor operating at full power (450 kW). The maximum value of &#x0394;<!-- Δ --> T that is predicted by the analytic model for the OFBGT design is smaller by approximately 1.1 °C than the value of &#x0394;<!-- Δ --> T which is predicted by the numerical model, for the same OFBGT design, but including all the details of the design. We have used the analytical model of thermal transport in an OFBGT to determine a normalized Modulation Transfer Function M T F &#x2032; ( k ) ) for the OFBGT. We conclude that MTF &#x2032;<!-- ' --> ( k OSU ) > 0.99 , where k OSU is the spatial frequency for the axial dependence of the reactor power distribution in the

47 OTHER INSTRUMENTATION↗

Grid Forming Inverter With Increased Short-Circuit Contribution to Address Inverter-Based Microgrid Protection Challenges

Substantial differences in fault levels between grid-tied and islanded modes is one of the primary challenges of microgrid protection. During grid-tied mode, the bulk grid provides significant short-circuit, while during islanded operation the short-circuit magnitude is small due to inverter-based resources limiting their current output close to nominal ratings. Consequently, conventional distribution protection strategies based on overcurrent cannot reliably protect microgrids when operating in islanded mode. Fuses and circuit breakers are particularly affected because of their inverse characteristics. Presently, the absence of affordable solutions for protecting microgrids in islanded mode leads to microgrids shutting down during electrical faults. The contribution of this article is two-fold. The first innovation proposes specific hardware modifications to grid-forming inverters to increase their short-circuit current during electrical faults. The second innovation introduces a novel control strategy designed to preserve control stability margins even when the grid-filter saturates, ensuring sinusoidal output currents under normal and fault conditions. Through experimental results, the inverter with the proposed modifications can provide more than three-times its nominal current during electrical faults. For the prototype testbed, this was sufficient to enable the use of traditional legacy overcurrent protection, achieving the fuse-to-relay and relay-to-relay minimum coordination time for the line-to-ground, line-to-line to ground, and three-phase electrical faults.

42 ENGINEERING↗

A 50 kA Superconducting Transformer for the Upcoming High-Field High-Current Testing Station at the BNL

Brookhaven national laboratory is upgrading its existing user facility to support R&D for High Energy Physics (HEP) and Fusion Energy Sciences (FES). The goal of this upgrade is to host the testing of the superconducting cables, conductors, joints and insert coils under high magnetic field (10 T), with currents up to 50 kA (present limit 20 kA) and at temperatures varying from 4 K to 40 K. To provide a current up to 50 kA to the sample, a superconducting core-less transformer is under construction. The superconducting transformer would additionally reduce the heat loss at the current leads at high currents. The SC transformer consists of two coaxial coils. The primary coil is inside the secondary coil. The primary coil consists of 3048 turns of rectangular wires (1.91 mm x 1.27 mm), wound in 24 layers. The secondary coil consists of 13 turns of the secondary cable (18.35 mm x 5.96 mm), wound in one layer. The parameters of the transformer are chosen to satisfy the space restrictions while using the available conductor. Here this paper presents the design of the 50-kA transformer.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Four-Switch Buck-Boost Converter Based on Model Predictive Control with Smooth Mode Transition Capability

Four-switch buck-boost converter supports both voltage step-up and step-down functionalities, but it suffers from mode transfer challenge that would need reliable mode detection when designed to operate in multi different modes. In this paper, a novel control method based on model predictive current control is proposed for such converter with inherent smooth mode transfer capability without extra design on mode detection and transfer scheme. Modulator and mode detection are replaced by an optimization process through cost function. This largely simplifies the design and makes it easily implemented. Therefore, seamless transfer between buck and boost modes is achieved with many other system level benefits. Simulation and experimental results are provided to verify the effectiveness of proposed method for the four-switch buck-boost converter.

42 ENGINEERING↗

High Flux Isotope Reactor Neutron Spectrum Shape Estimation From Activation Experiment Data

Here, this article provides a comprehensive review of historical irradiation dosimetry available for different locations within the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL). This article includes a summary of the available measured activation target data covering a span of over 15 years and 39 experimental campaigns, including 200 individual sample locations evaluated. Using this broad set of data, we reconstruct historic average neutron spectra shapes for HFIR at various locations, including within the flux trap region, beryllium reflectors, and hydraulic tube (HT) regions, at both the 100- and 85-MW operational power. Our findings indicate that the general axial flux distribution shows a relatively small change in transition from 100- to 85-MW operating power, with differences of -6% to +15% for the thermal energy range and around -16% to +8% for the fast range, indicating a sharper drop-off of the thermal neutron flux away from the axial center. Compared with historical dosimetry estimates of the HFIR flux shape, we generally find a moderately broader axial profile shape for thermal neutrons in the interior target regions for the 100-MW samples evaluated but relatively close agreement for the present 85-MW flux shape for both thermal and fast fluxes.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Surrogate Distributed Radiological Sources—Part II: Aerial Measurement Campaign

In this second part of a multipaper series, we present results from outdoor aerial measurements of surrogate distributed gamma-ray sources. Here we detail the design, manufacture, and testing of 300 individual ~7 mCi Cu-64 sealed sources at the Washington State University (WSU) research reactor and their deployment in various source patterns (each comprising up to 100 point sources) during the aerial measurement campaign. We show the results of two such measurements, in which approximate source shapes and qualitative source intensities can be seen from the count rate versus position plots, even without performing reconstructions. We also detail our efforts in ground-truthing the deployed sources and comparing measured gamma-ray data to model predictions. In particular, we compare measured versus expected count data using the Poisson deviance formalism of Part I to evaluate whether the fielded surrogate point-source arrays “look like” their truly continuous distributed source analogs. More generally, we find that the point-source array technique provides high source placement accuracy, relative ease of quantifying the true source configuration, scalability to source dimensions of ≲100 m, ease of reconfiguration and removal, and relatively low dose to personnel. Finally, we consider potential improvements and generalizations of the point-source array technique for future measurement campaigns.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Planar Transformer With Asymmetric Integrated Leakage Inductance Using Horizontal Air Gap

This article presents a novel planar-based transformer winding and core structure with controllable leakage inductance generation for integrated magnetics applications. As a result of limitations in integrated magnetics from the literature, a new approach is proposed utilizing semi-interleaved windings and controllable leakage via a leakage flux core leg featuring a horizontal air gap. Here, the proposed transformer design is analyzed via detailed reluctance modeling to determine closed-form equations for the magnetizing and asymmetrically distributed leakage inductances. Next, a genetic-algorithm-based multiobjective design optimization problem is developed, seeking to minimize the core and winding losses of the proposed transformer subject to a set of parametric and geometric constraints in a dc-ac dual-active-bridge topology for microinverter applications. The optimization was extended to include other integrated magnetic structures from the literature, where it is determined that the proposed transformer is superior from the perspectives of efficiency, footprint area, and parasitic capacitance. Based on the results of the optimization analysis, two designs with theoretical transformer California Energy Commission (CEC) efficiency drops (i.e., CEC efficiency reduction specifically due to the transformer loss mechanisms) of 1.19% and 0.83% were fabricated and evaluated for electrical and thermal performance in the proposed 40 V, 400 W microinverter.

42 ENGINEERING↗

A Prototype High-Voltage Pulsed Power Supply for Control of the ITER Shattered Pellet Injection System Flyer Plate Valve

A high-voltage pulsed power supply (HVPPS) has been designed, prototyped, and tested for driving an eddy current actuated propellant valve for the International Thermonuclear Experimental Reactor (ITER) disruption mitigation system. The high-voltage (HV) dc supply output voltage is software programmable, and the energy storage capacitor bank can be readily reconfigured as 200, 400, 600, and 800 μ F, enabling testing and optimization of both the valve drive and valve systems. Multiple system parameters are monitored before, during, and after each firing of the valve. The system parameters are both displayed and stored for further analysis. Control of the setup, firing sequence, and data collection is automated using a LabVIEW-based control program. The programmability and reconfigurability of this system collectively provide a flexible and robust platform for system refinement and optimization. In this article, a summary of the system will be provided including operational sequences, HV switching and associated triggering methods and circuits, and results measured while firing a solid frozen pellet. Additionally, planned refinement activities toward meeting all requirements for ITER integration will be discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On a High-Mirror Stellarator Reactor Exploratory Concept With Neutrons Concentrated on Centrifuge Liquids

In the framework of fusion energy research based on magnetic confinement, stellarators allow numerous degrees of freedom for the design of the magnetic trap and plasma shape. Taking advantage of these features, some plasma shapes might benefit several of the many integrated elements involved in commercial fusion reactors, like, e.g., decreasing the number, mass and complexity of replaced activated in-vessel components (IVC) (i.e., by using liquids), extraction of large power, tritium generation, and remote maintenance. Certainly, free-surface liquid materials were proposed for tokamaks and field-reversed configuration (FRC) to try to improve some of such elements, i.e., in advanced power extraction (APEX) studies. Some reactor-relevant quasi-isodynamic (QI) magnetic configurations exhibit a relatively straight sector of plasma and high magnetic mirror. The combination of those elements and possibilities in a single stellarator reactor concept might have some advantages, in spite of the uncertainties due to the current low technological readiness level (TRL). The proposed and studied reactor concept is based on a vacuum vessel having short curved sectors and longer wide cylindrical sectors, which encloses a high-mirror low-vertical-excursion magnetic configuration, and swirling liquids or rotating cylinders, which centrifuge molten Li salts located at the low field region. Thus, the molten salts (if possible covered by a thin layer of liquid lithium) would be located on the internal perimeter of the cylinder, to act as particle exhaust (except for helium), neutron power extractor, and tritium breeder. The high-mirror feature tries to concentrate the neutron power at the cylindrical sectors, which might avoid using breeding materials at the curved sectors. The different elements of the concept are exploratorily studied and defined, and the difficulties assessed.

centrifuge↗

A Hybrid DC Fault Primary Protection Algorithm for Multi-Terminal HVdc Systems

Protection against dc faults is one of the main technical hurdles faced when operating converter-based HVdc systems. Protection becomes even more challenging for multi-terminal dc (MTdc) systems with more than two terminals/converter stations. In this paper, a hybrid primary fault detection algorithm for MTdc systems is proposed to detect a broad range of failures. Sensor measurements, i.e., line currents and dc reactor voltages measured at local terminals, are first processed by a top-level context clustering algorithm. For each cluster, the best fault detector is selected among a detector pool according to a rule resulting from a learning algorithm. The detector pool consists of several existing detection algorithms, each performing differently across fault scenarios. The proposed hybrid primary detection algorithm: i) offers superior performance compared to an individual detector through a data-driven approach; ii) detects all major fault types including pole-to-pole (P2P), pole-to-ground (P2G), and external dc faults; iii) identifies faults with various fault locations and impedances; iv) is more robust to noisy sensor measurements compared to existing methods; v) does not require exhaustive simulation and sampling for training the model. Performance and effectiveness of the proposed algorithm are evaluated and verified based on time-domain simulations in the PSCAD/EMTDC software environment. The results confirm satisfactory operation, accuracy, and detection speed of the proposed algorithm under various fault scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗