Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “inductive charging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Longitudinal Confinement of an Intense Beam Using Induction Focusing

Induction focusing is successfully used to confine a space-charge dominated beam for over 11.52 km, or more than 1000 turns in a 3.66 m-diameter ring with the periodic application of longitudinal fields to overcome the defocusing space-charge forces.

43 PARTICLE ACCELERATORS↗

Investigation of the suppression effect of polyethylene glycol on copper electroplating by electrochemical impedance spectroscopy

Polyethylene glycol (PEG) is an additive that is commonly used as a suppressor in the semiconductor copper (Cu)-electroplating process. In this study, electrochemical impedance spectroscopy (EIS) was used to analyze the electrochemical behavior of PEG in the Cu-electroplating process. Polarization analysis, cyclic-voltammetry stripping, and cell voltage versus plating time were examined to clarify the suppression behavior of PEG. The equivalent circuit simulated from the EIS data shows that PEG inhibited the Cu-electroplating rate by increasing the charge-transfer resistance as well as the resistance of the adsorption layer. The presence of a large inductance demonstrated the strong adsorption of cuprous-PEG-chloride complexes on the Cu surface during the Cu-electroplating process. Increasing the PEG concentration appears to increase the resistances of charge transfer, the adsorption layer, and the inductance of the electroplating system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nearly monoenergetic positive ion beam with self-neutralized space charge extracted from a pulsed plasma

Not provided.A nearly monoenergetic Ar + ion beam (100 eV peak energy, 3.5 eV full width at half maximum), with self-neutralized space charge, was extracted from a power modulated (pulsed) inductively coupled plasma (ICP), through a single grounded grid. The beam energy was set by applying a synchronous DC bias voltage to a boundary electrode in contact with the plasma, in the late afterglow of the power pulse. A retarding field energy analyzer and a movable Faraday cup were used to measure the ion energy distribution (IED) and the time resolved ion and electron current densities, as a function of position along the beam axis, to unravel the mechanism of self-neutralization of the space charge of the beam. When a +100 V DC bias was applied to the boundary electrode during the afterglow, a ~100 eV beam (ion density ~10 9 cm -3 ) emerged that was space-charge neutralized by periodic injection of electrons, mainly during the early afterglow, into the region downstream of the extraction grid. A background plasma (electron density ~10 10 cm -3 ) was formed by these electrons, in conjunction with relatively low-energy ions (1–10 eV) that flew out of the ICP when the DC bias was off, as well as formed by resonant charge exchange of the 100 eV beam ions with the background Ar in the downstream region near the extraction grid. The behavior of the beam IED as a function of pressure and power of the ICP as well as the timing of application of the DC bias voltage was also studied.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Partial breaking of the Coulombic ordering of ionic liquids confined in carbon nanopores

Ionic liquids are composed of equal quantities of positive and negative ions. In the bulk, electrical neutrality occurs in these liquids due to Coulombic ordering, in which ion shells of alternating charge form around a central ion. Their structure under confinement is far less well understood. This hinders the widespread application of ionic liquids in technological applications. Here we use scattering experiments to resolve the structure of a widely used ionic liquid (EMI–TFSI) when it is confined inside nanoporous carbons. We show that Coulombic ordering reduces when the pores can accommodate only a single layer of ions. Instead, equally charged ion pairs are formed due to the induction of an electric potential of opposite sign in the carbon pore walls. This non-Coulombic ordering is further enhanced in the presence of an applied external electric potential. Furthermore, this finding opens the door for the design of better materials for electrochemical applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of a High Resolution Liquid Xenon Imaging Telescope for Medium Energy Gamma Ray Astrophysics

In the third year of the research project, we have (1) tested a 3.5 liter prototype of the Liquid Xenon Time Projection Chamber, (2) used a prototype having a 4.4 cm drift gap to study the charge and energy resolution response of the 3.5 liter chamber, (3) obtained an energy resolution as good as that previously measured by us using chambers with drift gaps of the order of millimeters, (4) observed the induction signals produced by MeV gamma rays, (4) used the 20 hybrid charge sensitive preamplifiers for a nondestructive readout of the electron image on the induction wires, (5) performed extensive Monte Carlo simulations to obtain results on efficiency, background rejection capability, and source flux sensitivity, and (6) developed a reconstruction algorithm for events with multiple interaction points.

Aprile, Elena↗

The physics of the oscillating lightning

The lightning is proposed to start in a limited region of electric breakdown field. A growing charge pool in a cumulonimbus cloud is likely to produce such a field in its outer layers. When the field is not aligned with the potential surfaces, the electric force pushes positive charge in one direction and negative in the opposite. Self inductance develops and an embryo open electric circuit is born. Oscillations swiftly grow in strength when potential energy of the cloud is released. The channel extends in steps during those cycle stages where charge is crammed into the channel terminals. Electrostatic consequences of a narrow conductor among the cloud charges are computed. The conductor is charged by influence to such a degree that the charge is bound to leak out to the ambient air and appear as a charge sheath some distance off the channel. Ample energy is released to sustain the oscillations. The period increases with channel length and agrees well with observed time between steps. A ground strike leads to a shock pulse travelling up the channel.

Storebo, Per B.↗

Studies of Bystander Effects in 3-D Tissue Systems Using a Low-LET Microbeam

It is now accepted that biological effects may occur in cells that were not themselves traversed by ionizing radiation but are close to those that were. Little is known about the mechanism underlying such a bystander effect, although cell-to-cell communication is thought to be important. Previous work demonstrated a significant bystander effect for clonogenic survival and oncogenic transformation in C3H 10T(1/2) cells. Additional studies were undertaken to assess the importance of the degree of cell-to-cell contact at the time of irradiation on the magnitude of this bystander effect by varying the cell density. When 10% of cells were exposed to a range of 2-12 alpha particles, a significantly greater number of cells were inactivated when cells were irradiated at high density than at low density. In addition, the oncogenic transformation frequency was significantly higher in high-density cultures. These results suggest that when a cell is hit by radiation, the transmission of the bystander signal through cell-to-cell contact is an important mediator of the effect, implicating the involvement of intracellular communication through gap junctions. Additional studies to address the relationship between the bystander effect and the adaptive response were undertaken. A novel apparatus, where targeted and non-targeted cells were grown in close proximity, was used to investigate these. It was further examined whether a bystander effect or an adaptive response could be induced by a factor(s) present in the supernatants of cells exposed to a high or low dose of X-rays, respectively. When non-hit cells were co-cultured for 24 h with cells irradiated with 5 Gy alpha-particles, a significant increase in both cell killing and oncogenic transformation frequency was observed. If these cells were treated with 2 cGy X-rays 5 h before co-culture with irradiated cells, approximately 95% of the bystander effect was cancelled out. A 2.5-fold decrease in the oncogenic transformation frequency was also observed. When cells were cultured in medium donated from cells exposed to 5 Gy X-rays, a significant bystander effect was observed for clonogenic survival. When cells were cultured for 5 h with supernatant from donor cells exposed to 2 cGy and were then irradiated with 4 Gy X-rays, they failed to show an increase in survival compared with cells directly irradiated with 4 Gy. However, a twofold reduction in the oncogenic transformation frequency was seen. An adaptive dose of X-rays cancelled out the majority of the bystander effect produced by alpha-particles. For oncogenic transformation, but not cell survival, radioadaption can occur in unirradiated cells via a transmissible factor(s). A pilot study was undertaken to observe the bystander effect in a realistic multicellular three-dimensional morphology. We found bystander responses in a three-dimensional, normal human-tissue system. Endpoints were induction of micronucleated and apoptotic cells. A charged-particle microbeam was used, allowing irradiation of cells in defined locations in the tissue yet guaranteeing that no cells located more than a few micrometers away receive any radiation exposure. Unirradiated cells up to 1 mm distant from irradiated cells showed a significant enhancement in effect over background, with an average increase in effect of 1.7-fold for micronuclei and 2.8-fold for apoptosis. The surprisingly long range of bystander signals in human tissue suggests that bystander responses may be important in extrapolating radiation risk estimates from epidemiologically accessible doses down to very low doses where nonhit bystander cells will predominate. Finally, it would be of great benefit to develop a reproducible tissue system suitable for critical radiobiological assays. We have developed a reliable protocol to harvest cells from tissue samples and to investigate the damage induced on a single cell basis. In order to result in a valid tool for bystander experiments, the method focuses on processing and analyzing radiation damage in individual cells as a function of their relative position in the tissue. We have investigated the micronucleus formation following partial irradiation with 3.5 MeV protons in an artificial human skin construct. Following the optimization of the Cytochalasin-B concentration and incubation time necessary to obtain a reproducible and suitable number of binucleated cells, the induction of micronuclei across the samples is assessed for 3 dose. The reproducible and low background frequency of micronuclei measured in this system allowed us to detect small increases following the irradiation exposure. The effect is statistically significant at doses as low as 0.1 Gy and it shows evidence of a spatial dependency as it decreases in the cells further away from the directly exposed area. This experimental protocol represents the initial steps in the development of an in vivo-like assay for complex radiation damage in human tissues.

59 BASIC BIOLOGICAL SCIENCES↗

Influence of magnetic field on electric-field-induced local polar states in manganites

It is shown that creation of local charged states at the surface of the lanthanum-strontium manganite single crystals by means of bias application via a conducting atomic force microscope tip is strongly affected by magnetic field. Both a charge and a size of created structures increase significantly on application of the magnetic field during the induction. We argue that the observed phenomenon originates from a known tendency of manganites toward charge segregation and its intimate relation to magnetic ordering.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cavallo's multiplier for in situ generation of high voltage

Here, a classic electrostatic induction machine, Cavallo's multiplier, is suggested for in situ production of very high voltage in cryogenic environments. The device is suitable for generating a large electrostatic field under conditions of very small load current. Operation of the Cavallo multiplier is analyzed, with quantitative description in terms of mutual capacitances between electrodes in the system. A demonstration apparatus was constructed, and measured voltages are compared to predictions based on measured capacitances in the system. The simplicity of the Cavallo multiplier makes it amenable to electrostatic analysis using finite element software, and electrode shapes can be optimized to take advantage of a high dielectric strength medium such as liquid helium. A design study is presented for a Cavallo multiplier in a large-scale, cryogenic experiment to measure the neutron electric dipole moment.

47 OTHER INSTRUMENTATION↗

Charged-particle mutagenesis II. Mutagenic effects of high energy charged particles in normal human fibroblasts

The biological effects of high LET charged particles are a subject of great concern with regard to the prediction of radiation risk in space. In this report, mutagenic effects of high LET charged particles are quantitatively measured using primary cultures of human skin fibroblasts, and the spectrum of induced mutations are analyzed. The LET of the charged particles ranged from 25 KeV/micrometer to 975 KeV/micrometer with particle energy (on the cells) between 94-603 MeV/u. The X-chromosome linked hypoxanthine guanine phosphoribosyl transferase (hprt) locus was used as the target gene. Exposure to these high LET charged particles resulted in exponential survival curves; whereas, mutation induction was fitted by a linear model. The Relative Biological Effect (RBE) for cell-killing ranged from 3.73 to 1.25, while that for mutant induction ranged from 5.74 to 0.48. Maximum RBE values were obtained at the LET of 150 keV/micrometer. The inactivation cross-section (alpha i) and the action cross-section for mutant induction (alpha m) ranged from 2.2 to 92.0 micrometer2 and 0.09 to 5.56 x 10(-3) micrometer2, respectively. The maximum values were obtained by 56Fe with an LET of 200 keV/micrometer. The mutagenicity (alpha m/alpha i) ranged from 2.05 to 7.99 x 10(-5) with the maximum value at 150 keV/micrometer. Furthermore, molecular analysis of mutants induced by charged particles indicates that higher LET beams are more likely to cause larger deletions in the hprt locus.

NASA Center JSC↗

Charged-particle mutagenesis 2. Mutagenic effects of high energy charged particles in normal human fibroblasts

The biological effects of high Linear Energy Transfer (LET) charged particles are a subject of great concern with regard to the prediction of radiation risk in space. In this report, mutagenic effects of high LET charged particles are quantitatively measured using primary cultures of human skin fibroblasts, and the spectrum of induced mutations are analyzed. The LET of the charged particles ranged from 25 KeV/micrometer to 975 KeV/micrometer with particle energy (on the cells) between 94-603 MeV/u. The X-chromosome linked hypoxanthine guanine phosphoribosyl transferase (hprt) locus was used as the target gene. Exposure to these high LET charged particles resulted in exponential survival curves; whereas, mutation induction was fitted by a linear model. The Relative Biological Effect (RBE) for cell-killing ranged from 3.73 to 1.25, while that for mutant induction ranged from 5.74 to 0.48. Maximum RBE values were obtained at the LET of 150 keV/micrometer. The inactivation cross-section (alpha i) and the action cross-section for mutant induction (alpha m) ranged from 2.2 to 92.0 sq micrometer and 0.09 to 5.56 x 10(exp -3) sq micrometer respectively. The maximum values were obtained by Fe-56 with an LET of 200 keV/micrometer. The mutagenicity (alpha m/alpha i) ranged from 2.05 to 7.99 x 10(exp -5) with the maximum value at 150 keV/micrometer. Furthermore, molecular analysis of mutants induced by charged particles indicates that higher LET beams are more likely to cause larger deletions in the hprt locus.

Chen, D. J.↗

Neural network model of neutral beam injection in the EAST tokamak to enable fast transport simulations

The neutral beam injection (NBI) system in EAST produces energetic neutral particles, which collide with electrons and ions in tokamak plasmas and heat the plasmas through Coulomb collisions. Moreover, it drives a non-inductive source of current, due to the charge-exchange collision between neutral particles and ions, and injects toroidal torque, which generates a toroidal rotation of the plasma. The effect caused by the NBI system, such as plasma heating, current drive, total neutron rate, momentum transfer, and shine-through, are modeled by a comprehensive module called NUBEAM. However, NUBEAM is computationally intensive since it relies on Monte Carlo methods. In this work, a neural network model has been developed as a surrogate model for NUBEAM in EAST. The database for neural-network model training, validation and testing is generated by running TRANSP for experimental discharges from recent EAST campaigns (after the latest NBI upgrade) while using the NUBEAM module. Simulation results illustrate that the trained neural network has the capability of replicating the predictions made by NUBEAM while demanding a significantly shorter execution time. Finally, these results indicate that surrogate models like the one proposed in this work could enable fast transport simulations for EAST after integrating them into a control-oriented predictive code such as COTSIM.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of overcharge on Li(Ni 0.5 Mn 0.3 Co 0.2 )O 2 cathodes: NMP-soluble binder. II — Chemical changes in the anode

For this study, cells based on nickel manganese cobalt oxide (NMC)/graphite electrodes, which contained polyvinylidene difluoride (PVDF) binders in the electrodes, were systematically charged to 100, 120, 140, 160, 180, and 250% state of charge (SOC). Characterization of the anodes by inductively-coupled-plasma mass spectrometry (ICP-MS), X-ray photoelectron spectroscopy (XPS), and high-performance liquid chromatography coupled with electrospray ionization mass spectrometry (HPLC-ESI-MS) showed several extent-of-overcharge-dependent trends. The concentrations (by wt) of nickel, manganese, and cobalt in the negative electrode increased with SOC, but the metals remained in the same ratio as that of the positive. Electrolyte reaction products, such as LiF:LiPO 3 , increased with overcharge, as expected. Three organic products were found by HPLC-ESI-MS. From an analysis of the mass spectra, two of these compounds seem to be organophosphates, which were formed by the reaction of polymerized electrolyte decomposition products and PF 3 or O=PF 3 . Their concentration tended to reach a constant ratio. The third was seen at 250% SOC only.

25 ENERGY STORAGE↗

Bio-Nano ECRIS: An electron cyclotron resonance ion source for new materials production

We developed an electron cyclotron resonance ion source (ECRIS) for new materials production on nanoscale. Our main target is the endohedral fullerenes, which have potential in medical care, biotechnology, and nanotechnology. In particular, iron-encapsulated fullerene can be applied as a contrast material for magnetic resonance imaging or microwave heat therapy. Thus, our new ECRIS is named the Bio-Nano ECRIS. In this article, the recent progress of the development of the Bio-Nano ECRIS is reported: (i) iron ion beam production using induction heating oven and (ii) optimization of singly charged C{sub 60} ion beam production.

36 MATERIALS SCIENCE↗

P-Type Silicon Strip Sensors for the new CMS Tracker at HL-LHC

The upgrade of the LHC to the High-Luminosity LHC (HL-LHC) is expected to increase the LHC design luminosity by an order of magnitude. This will require silicon tracking detectors with a significantly higher radiation hardness. The CMS Tracker Collaboration has conducted an irradiation and measurement campaign to identify suitable silicon sensor materials and strip designs for the future outer tracker at the CMS experiment. Based on these results, the collaboration has chosen to use n-in-p type silicon sensors and focus further investigations on the optimization of that sensor type. This paper describes the main measurement results and conclusions that motivated this decision.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Liquid argon TPC signal formation, signal processing and reconstruction techniques

This document describes a reconstruction chain that was developed for the ArgoNeuT and MicroBooNE experiments at Fermilab. These experiments study accelerator neutrino interactions that occur in a Liquid Argon Time Projection Chamber. Reconstructing the properties of particles produced in these interactions benefits from the knowledge of the micro-physics processes that affect the creation and transport of ionization electrons to the readout system. A wire signal deconvolution technique was developed to convert wire signals to a standard form for hit reconstruction, to remove artifacts in the electronics chain and to remove coherent noise. A unique clustering algorithm reconstructs line-like trajectories and vertices in two dimensions which are then matched to create of 3D objects. In conclusion, these techniques and algorithms are available to all experiments that use the LArSoft suite of software.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Charge collection and electrical characterization of neutron irradiated silicon pad detectors for the CMS High Granularity Calorimeter

The replacement of the existing endcap calorimeter in the Compact Muon Solenoid (CMS) detector for the high-luminosity LHC (HL-LHC), scheduled for 2027, will be a high granularity calorimeter. It will provide detailed position, energy, and timing information on electromagnetic and hadronic showers in the immense pileup of the HL-LHC. The High Granularity Calorimeter (HGCAL) will use 120-, 200-, and 300-$\mu\textrm{m}$ thick silicon (Si) pad sensors as the main active material and will sustain 1-MeV neutron equivalent fluences up to about $10^{16}~\textrm{n}_\textrm{eq}\textrm{cm}^{-2}$. In order to address the performance degradation of the Si detectors caused by the intense radiation environment, irradiation campaigns of test diode samples from 8-inch and 6-inch wafers were performed in two reactors. Characterization of the electrical and charge collection properties after irradiation involved both bulk polarities for the three sensor thicknesses. Since the Si sensors will be operated at -30 $^\circ$C to reduce increasing bulk leakage current with fluence, the charge collection investigation of 30 irradiated samples was carried out with the infrared-TCT setup at -30 $^\circ$C. TCAD simulation results at the lower fluences are in close agreement with the experimental results and provide predictions of sensor performance for the lower fluence regions not covered by the experimental study. All investigated sensors display 60$\%$ or higher charge collection efficiency at their respective highest lifetime fluences when operated at 800 V, and display above 90$\%$ at the lowest fluence, at 600 V. The collected charge close to the fluence of $10^{16}~\textrm{n}_\textrm{eq}\textrm{cm}^{-2}$ exceeds 1 fC at voltages beyond 800 V.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterisation of signal-induced noise in Hamamatsu R11265 Multianode Photomultiplier Tubes

Signal-induced noise is observed in Hamamatsu R11265 Multianode Photomultiplier Tubes, manifesting up to several microseconds after the single photoelectron response signal and localised in specific anodes. The mean number of noise pulses varies between devices, and shows significant dependence on the applied high-voltage. The characterisation of this noise and the mitigation strategies to perform optimal single-photon counting at 40 MHz, as required by the LHCb Ring-Imaging Cherenkov detectors, are reported.

47 OTHER INSTRUMENTATION↗