Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “importance sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Noble Gases in Samples Returned From Asteroids Ryugu and Bennu

Introduction: The asteroid sample return missions, JAXA’s Hayabusa2 [1] and NASA’s OSIRIS-REx [2], fromC-rich asteroids Ryugu and Bennu offer unique opportunities to sample pristine early solar system material, unaffected by terrestrial weathering and contamination, and with a known geological context. The comparison with most primi-tive members of carbonaceous –and inner solar system ordinary and enstatite– chondrite classes allows us to (i) assess the variation (or the lack of thereof) of the distribution of the most volatile elements throughout the entire early solar system, (ii) determine the effects of parent body thermal and aqueous alteration, and (iii) learn about the dynamic evolution and history of the various parent bodies, as sampled by both return missions and meteorite delivery. Here we will present noble gas data obtained from newly received particles from Ryugu and Bennu. Samples & Analysis: We received nine particles allocated by JAXA, with masses of 0.5-1.7 mg mass: four col-lected during Hayabusa2’s first touchdown (chamber A) and five from a small artificial crater (chamber C). We received three particles from Bennu of 0.07, 0.89 and 0.94 mg mass (OREX-800032-102/3/4). All particles were processed, allocated, weighed, and transferred into our UHV sample chamber within pure N2, to prevent any contact with air. We examined all He-Xe isotopes with our custom-built mass spectrometer “Albatros” ([3,4]). Gases were extracted individually from each particle by melting induced by a 1064 μm Nd:YAG IR laser in 2–4 heating steps. Large amounts of water and other reactive volatiles were released, consistent with the presence of abundant volatiles from both Ryugu and Bennu. Residues of Ryugu particles remaining after lasering, subsequently exposed to air, were additionally extracted in a crucible to verify complete gas extraction. Only the particle that still showed a “crystalline” structure after lasering contained detectable Ryugu noble gases, whereas all other particles turned immediately into glassy spheres by laser heating and lacked any gas. Results & Discussion: Ryugu and Bennu matter contains noble gases similar to the most pristine, unheated aqueously altered meteorites, e.g., CM or CI chondrites [5,6]. Remarkably, all four chamber A samples that originated from Ryugu’s surface show solar wind (SW) Ne (trapped (20Ne/22Ne)tr ~12–13), whereas all five chamber C samples do not ((20Ne/22Ne)tr ~9.0–10.7 consistent with the presence of non-solar trapped Ne components such as Q and HL). This demonstrates that JAXA’s sampling strategy succeeded: Chamber C samples analyzed in this work originated from areas shielded from SW, slightly below the surface, that was sampled after the impactor excavated material. The three Bennu particles populate the same range as the Ryugu particles in Ne isotope space with one particle containing SW suggesting that it was part of the uppermost surface layer of Bennu during sampling, while Ne in the smallest sample can be explained best by mixing Ne from presolar diamonds and SiC or graphite, and that in the third one by mixing of, e.g., Q and HL. Using cosmic ray production rates given by [7] yields preliminary exposure ages for Ryugu particles in the same range as determined in [7]. There is, as expected, also no systematic difference between samples from chambers A and C because both sample sets were likely collected within the uppermost layer of Ryugu, which were not shielded from cosmic rays. The concentration of cosmogenic (cos) Ne in the Bennu particle, where Necos was resolvable, is in the same range as found for Ryugu, suggesting roughly similar exposure time to cosmic rays for 5–8 Ma for all particles examined here. The Xe isotopic compositions of all particles are consistent with those of phase Q, with small additions of Xe-HL from presolar diamonds and excess 129Xe* from short-lived 129I decay. The comparably high 129Xe*/129XeQ ratio is similar in all samples, suggesting similar initial I concentrations and closure to Xe loss –or the incorporation of a well-mixed Xe reservoir. The Bennu material was in brief contact with air in the capsule, after atmospheric entry and before storage in pure N2 in a clean room. Both, the –most diagnostic– Xe isotopes and the Ar/Xe vs. Kr/Xe systematics prove that the noble gases are not affected by terrestrial contamination, in contrast to many CI, CY, and CM chondrites found on Earth [5,6], illustrating the importance of sample return. He-Xe concentrations in all particles unaffected bySW are comparable to but at the upper end of ranges reported [5-7]. In accordance with the strong aqueous alteration experienced on the parent bodies of Ryugu and Bennu [1,2], all samples lack the Ar-rich and water-susceptible noble gas components found in less aqueously altered CMs or CRs [e.g., 5,8] and all COs.

Henner Busemann↗

STARDUST and Interplanetary Dust Particles - Big Science from Small Samples

Comets are primitive bodies that are widely believed to be a reservoir of preserved interstellar and circumstellar grains, and molecular cloud materials (organics). Direct samples of cometary dust along with interstellar grains will be returned by the STARDUST Mission in 2006. Analyses of interplanetary dust particles (IDPs) and analogue materials in the laboratory provide constraints and serve as "ground truth" for evaluating various hypotheses on the nature of comets and interstellar grains. Anhydrous IDPs are the most primitive remnants of the primordial Solar System, and are our only known samples of comets. These cometary lDPs are rich in preserved interstellar organic compounds II]. In addition, abundant interstellar silicates have recently been discovered in cluster lDPs [2]. In some of these IDPs, the presolar silicate abundance reaches 1 wt %, exceeding the total presolar grain abundance in meteorites by three orders of magnitude, where presolar silicates are still notably absent. The results to date support the idea that comets are rich in presolar materials, but are at odds with the common perception that they are 'pristine aggregates of interstellar grains'. These results underscore the scientific importance of sample return missions to comets. The technology for the analysis of micrometer-sized samples is well advanced. The newest generation of ion probe instruments allow for isotopic analyses at the submicrometer level. The nature of the organic matter is analyzed using Infrared and soft X-ray spectroscopy techniques on synchrotron-based instruments, also at the micrometer-scale and smaller. Electron microscopy and spectroscopy provide details on the mineralogy and chemistry of constituent grains in !DPs at nearly the atomic scale. Novel sample preparation techniques have been developed such that all of these measurements can now be made on the same 10 micrometer diameter particle. Returned comet samples captured in aerogel will pose new challenges in sample analysis, but should provide a major leap in our understanding of the fundamental building blocks of our Solar System.

Keller, L. P.↗

The Importance of Contamination Knowledge - Insights into Mars Sample Return

The Astromaterials Acquisition and Curation Office at NASA Johnson Space Center (JSC), in Houston, TX (henceforth Curation Office) manages the curation of all past, present, and future extraterrestrial samples returned by NASA missions and shared collections from international partners, preserving their integrity for future scientific study while providing the samples to the international community in a fair and unbiased way. The Curation Office also curates all reference and witness materials for each mission (e.g., flight and non-flight hardware coupons; lubricants; non-flight, flight-like, and flown witness plates). These reference and witness materials provide the scientific community with the fundamental ability to reconstruct the contamination/alteration history of the sample collection through the course of the mission, with the overall goal of strengthening the scientific conclusions drawn from the study of returned materials. The information gained from characterizing the physical, biological, inorganic, and organic chemical properties of reference and witness materials is defined as the Contamination Knowledge (CK) of the sample collection. Unlike the data collected for Contamination Control (CC) and Planetary Protection (PP), CK is exclusively concerned with preserving reference and witness materials for study by future scientists upon sample return. Although CC and PP data collected for sample integrity and forward contamination purposes can be complementary to CK, they are two separate data sets with distinct objectives. A robust collection of samples for CK is necessary to allow the extraterrestrial material in a returned sample to be distinguished from terrestrial contamination. Traditionally CK is utilized by sample scientists in order to accomplish the mission’s scientific objectives, however this information can also be utilized by the Office of Planetary Protection to help evaluate the presence of any back contamination. Mars 2020, the first phase of a potential multipart Mars Sample Return (MSR) campaign, is expected to contribute to NASA’s Mars Exploration Program Science Goals by filling in knowledge gaps concerning: 1) the existence of past or present life on Mars, 2) the past and present climate of Mars, 3) the geology of Mars, and 4) hazards associated with human exploration of Mars. Although there is debate concerning which samples will best answer these questions, the necessity for proper sample blanks is well-understood. The CC and PP requirements, driven by the restricted Class V mission designation, are the most stringent of any sample return mission in recent history. The extremely low levels of allowable terrestrial contamination on the spacecraft and rover can complicate these analyses given the detection limits of current analytical instrumentation, especially in the case of biological contamination. By collecting and curating unanalyzed samples specifically for CK, future sample scientists will not be relegated to: 1) relying on data collected using possibly obsolete tools and techniques for return sample blanks, or 2) using remnants of extracted and/or cultured samples from ATLO (Assembly, Test, and Launch Operations), which could be incompatible with the desired experimental endpoints or state-of-the-art techniques available at the time of sample return.The addition of biological experimental endpoints to a sample return campaign’s objectives broadens the requisite range in preservation environments (e.g. inert ultra-pure nitrogen gaseous environment at 18 degrees Centigrade versus less than or equal to minus 80 degrees Centigrade) and types of CK samples. As a result, the Curation Office will also curate the following CK samples at less than or equal to minus 80 degrees Centigrade for the Mars 2020 mission: 1) unanalyzed swabs and wipes in sterile containers, 2) all recirculation filters from the clean rooms used for sample and caching subsystem assembly and all filters from the laminar flow benches used to assemble sample intimate hardware, and 3) witness plates collecting airborne contamination within the assembly clean rooms. It has been Curation Office policy since the Apollo missions to preserve as many pristine samples as possible for future scientific research. Although CK is required to be collected for all stages of the MSR campaign, the CK for the Mars 2020 mission is the most critical for understanding contamination in the returned samples given the intimacy between the Martian samples and the Mars 2020 flight hardware. This presentation highlights the importance of CK for sample return missions as well as the traditional and novel types of CK samples required for a successful MSR campaign.

Harrington, A. D.↗

Comparison of Synchrotron MicroXANES Determination of Fe(3+)/Sigma Fe with Moessbauer Values for Clean Mineral Separates of Pyroxene from Martian Meteorites

The oxidation state of Fe in Martian meteorites is a parameter of great interest and the ability to determine this value in micrometer scale samples is important. Intense, tunable x-ray sources at large synchrotron storage rings are being exploited to examine the Fe K-absorption edge with energy resolution of approx. 1-1.5eV in spots of 10x15 microns on thin sections of a wide variety of materials including several Martian meteorites. Synchrotron microXANES (SmX) spectroscopy is the technique that provides the most flexible capability for investigating Fe(3+)/Sigma Fe. Variation of Fe(3+)/Sigma Fe is manifested as a function of the energy of the pre-edge to the Fe absorption edge produced by the sample. SmX is at present the only technique that can be used with conventional polished thin sections. Data for a broad spectrum of minerals have been produced and indicate that SmX can be used with a large variety of samples types.

Delaney, J. S.↗

The Genesis Non-flight Implant Sample Archive

Introduction: For the past 20 years the Genesis science community has been analyzing solar wind captured in sample collectors now curated at Johnson Space Center (JSC). Non-flown flight like collector materials (non-flight) considered reference material was always allocated by the JSC Genesis team for testing experimental procedures. However, to expedite Genesis science, distribution of non-flown reference materials were also provided by, D. S. Burnett (Genesis PI, Caltech) and A. J. G. Jurewicz (ASU) who were funded to aid all Genesis PIs by providing engineering test materials archived at Caltech pre-flight as well as ion implants into these materials [1]. Implanted materials (non-flight reference, flight-like semiconductor materials, and NIST SRM glass) received from the Caltech collection during a pilot project are being used to develop an accession procedure for the purpose of making these materials available to researchers in the future. These implant samples are important because they can be utilized as measurement standards [2]. This is a work in progress and this work reports progress in documentation and imaging. The pilot program received 63 implanted reference materials with known implanted ions. Genesis Non-Flight Database: The existing non-flight material database was modified to allow for the description of implant sessions and to allow correlation of the implant information to individual specimens. An implant session has three main components: a known ion, a known dose (ion/cm2), and a known energy (keV). Procedure: Laboratory Procedure. Upon receiving non-flight analytical standards (independently calibrated implants), or implant samples (nominally calibrated implants), they will be imaged in their current containers to capture any information written before being brought into the Genesis Sample Laboratory. Documentation is provided by the donor and used for correlating the data between the implant sessions and implant samples. This information is not verified by Genesis Curation. The microscope used to image samples in the laboratory has an automated stage with a stainless-steel plate to hold samples and a camera that utilizes the software Surveyor to take photomosaic images of the implant samples. The camera attached to the microscope is a QICAM High Performance IEEE 1394 FireWire Digital CCD Camera. This setup, shown in Fig. 1, allows for photomosaics of small-scale samples with a 10x objective or 25x objective. Examples of images taken with this microscope setup are shown in Fig.2 and Fig. 3. After imaging, samples get stored in a clean fluoroware container or polypropylene vial depending on sample size for long term storage. Database Procedure. The Genesis Non-Flight Database currently allows for the addition of implant sessions. The required fields for adding an implant session are the implant session ion, the implant session dose, and the implant session energy. There are also fields for the date and vendor of the sessions as well as a field for if the session was calibrated or not. Once an implant session has been inserted into the database, additional documentation from the session can be attached. The database will automatically assign an Implant Session Number. After inserting an implant session, the implanted samples can be inserted. The fields required for an implant sample are the material of the sample and the size of the sample. The Generic name for the implant sample with be automatically generated by the database once it has been inserted. Implant sample numbers begin with 3X to distinguish from flown Genesis sample numbers. There are also fields for processors to add the location (room, cabinet, tray) and container type (fluoroware, polypropylene vial). Once an implant session and an associated sample(s) have been inserted into the database the sample can be then tied to all associated implant sessions. An implant sample can be tied to multiple implant sessions. Future work: For curation, future work consists of creating an online catalogue for implant samples as well as updating the database with more samples as we receive them. For the scientific community these implant samples have many potential uses. For Genesis research, they are directly applicable for testing and, in some cases, as analytical standards. For non-Genesis research, implants (especially calibrated implants) could be used for calibrating other, unique planetary materials [1].

C D Calva↗

i- flow: High-dimensional integration and sampling with normalizing flows

In many fields of science, high-dimensional integration is required. Numerical methods have been developed to evaluate these complex integrals. We introduce the code i-flow, a python package that performs high-dimensional numerical integration utilizing normalizing flows. Normalizing flows are machine-learned, bijective mappings between two distributions. i-flow can also be used to sample random points according to complicated distributions in high dimensions. We compare i-flow to other algorithms for high-dimensional numerical integration and show that i-flow outperforms them for high dimensional correlated integrals. The i-flow code is publicly available on gitlab at https://gitlab.com/i-flow/i-flow.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Implications from Monitoring Gopher Tortoises at Two Spatial Scales

A problem that conservation biologists face is how to monitor species, given both resource limitations and the inherent challenges of assessing long-term demographic processes. We assessed gopher tortoise (Gopherus polyphemus) abundance at a landscape scale and at the scale of 3 local populations within the Conecuh National Forest (CNF).USA between 1991 and 2017. Landscape-level data were collected 26 from line transect distance sampling arranged uniformly across the CNF and collected during a single season (2011); data for local populations were generated from long-term mark-recapture of individuals at three sites selected based on prior knowledge of high density at each. At a landscape scale, we estimated 5,242 (95% CI = 3,538-7,768) tortoises occurred across the approximately 34,000-ha forest, yielding a density of 0.14-0.32 tortoises/ ha. These low densities across the landscape suggest that, on average, management activities across the property have not allowed tortoise populations to retain social structure needed for long-term persistence. The three local populations, however, contained 25-60 individuals and densities of 1.9–6.9 tortoises/ha. Over the study period, populations at two sites were stable and the third experienced significant population growth. Mean annual survival of individuals was 0.89 and invariant across size classes. Altogether, line transect distance sampling is important for assessing landscape-scale abundance of tortoises but may fail to detect local clusters of high-density sites important for population persistence. Our mark-recapture efforts at the local scale revealed that small populations on these high-density sites can exhibit long-term stability or growth even though they do not meet current established criteria for viability. Improved models that incorporate immigration and emigration and better reflect dynamics of peripheral populations would assist in determining how such populations best contribute to species recovery and regional conservation targets.

59 BASIC BIOLOGICAL SCIENCES↗

The diffusivity of hydrogen in Nb stabilized stainless steel

The evolution of hydrogen from 347 stainless steel has been studied by using a real time dynamic technique under ultrahigh vacuum conditions. Auger electron spectroscopy was used to determine the surface composition as a function of time and temperature. The surface film on the electropolished samples was found to be approximately 15 A thick and consisted of a carbon-oxygen complex and a metal oxide (FexOy). Upon heating to 400 C, the carbon-oxygen complex desorbed as CO and the remaining oxygen and carbon began to incorporate. Also at this temperature sulfur began to diffuse out of the bulk to the surface and at approximately 800 C formed a complete monolayer. At 900 C, carbon and oxygen virtually disappeared, leaving the monolayer of sulfur as the only surface contaminant. The hydrogen diffusivity was found to follow closely the equation D = 7.01 x 10 to the -7th exp(-48.0/RT) sq m per second over the entire temperature range studied, thus indicating that hydrogen evolution is not significantly affected by the changing surface composition. The somewhat higher value of the diffusivity obtained in this work compared to past measurements in austenitic stainless steels may indicate the importance of sample preprocessing and ultrahigh vacuum conditions in minimizing the effects of surface layers.

Outlaw, R. A.↗

Frequency-domain hot-wire sensor and 3D model for thermal conductivity measurements of reactive and corrosive materials at high temperatures

High temperature solids and liquids are becoming increasingly important in next-generation energy and manufacturing systems that seek higher efficiencies and lower emissions. Accurate measurements of thermal conductivity at high temperatures are required for the modeling and design of these systems, but commonly employed time-domain measurements can have errors from convection, corrosion, and ambient temperature fluctuations. Here, we describe the development of a frequency-domain hot-wire technique capable of accurately measuring the thermal conductivity of solid and molten compounds from room temperature up to 800 °C. Therefore, by operating in the frequency-domain, we can lock into the harmonic thermal response of the material and reject the influence of ambient temperature fluctuations, and we can keep the probed volume below 1 µl to minimize convection. The design of the microfabricated hot-wire sensor, electrical systems, and insulating wire coating to protect against corrosion is covered in detail. Furthermore, we discuss the development of a full three-dimensional multilayer thermal model that accounts for both radial conduction into the sample and axial conduction along the wire and the effect of wire coatings. The 3D, multilayer model facilitates the measurement of small sample volumes important for material development. A sensitivity analysis and an error propagation calculation of the frequency-domain thermal model are performed to demonstrate what factors are most important for thermal conductivity measurements. Finally, we show thermal conductivity measurements including model data fitting on gas (argon), solid (sulfur), and molten substances over a range of temperatures.

47 OTHER INSTRUMENTATION↗

Effect and measurement of residual water in CaCl 2 intended for use as electrolyte in molten salt electrochemical processing

We report CaCl 2 has applications for electrochemical processing of nuclear materials. Thermal dehydration leads to formation of oxide ions, which are shown to react and cause precipitation of dissolved CeCl 3 that was selected as a surrogate for actinide chlorides. Thus, measurement of residual water in CaCl 2 is an essential capability. Thermogravimetric analysis (TGA) was shown to underestimate starting water concentration. Subsequent analysis of solid samples via acid–base titration and cyclic voltammetry (CV) of the molten salt yielded consistent values within 5% for residual water. Hydroxides were shown to be unstable, thus oxygen is retained as oxide ions. Thus, total water in a sample of CaCl 2 can be quantified by combining TGA with with either CV of molten salt or titration of salt samples. The importance of quantifying residual water in the salt was demonstrated by showing that cerium chloride (surrogate for actinide chlorides) will react with oxide ions in CaCl 2 to form insoluble oxides and oxychlorides.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A Comprehensive Monte Carlo Framework for Jet-Quenching

This article presents the motivation for developing a comprehensive modeling framework in which different models and parameter inputs can be compared and evaluated for a large range of jet-quenching observables measured in relativistic heavy-ion collisions at RHIC and the LHC. Here, the concept of a framework is discussed within the context of recent efforts by the JET Collaboration, the authors of JEWEL, and the JETSCAPE collaborations. The framework ingredients for each of these approaches is presented with a sample of important results from each. The role of advanced statistical tools in comparing models to data is also discussed, along with the need for a more detailed accounting of correlated errors in experimental results.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Predicting the X-ray Absorption Spectrum of Ozone with Single Configuration State Functions

X-ray absorption spectra (XAS) of biradicaloid species are often thought to represent a challenge to theoretical methods. This has led to the testing of recently developed multireference techniques on the XAS of ozone, but reproduction of the experimental spectral profile has proven difficult. We utilize a minimal model consisting of a single configuration state function (CSF) per excited state to model core-level excitations of ozone, with the orbitals of each CSF optimized using the restricted open-shell Kohn–Sham (ROKS) method. This protocol leads to semiquantitative agreement with experimental XAS. In fact, we find that low-lying core-hole excited states in biradicaloids can be approximated with individual CSFs, despite the presence of multireference character in the ground state. Here, we also report that the 1s → π* and 1s → σ* transitions have quite distinct widths for O 3 . This reveals the importance of sampling over a representative range of geometries from the vibrational ground state for properly assessing the accuracy of electronic structure methods against experiments instead of the popular procedure of uniformly broadening stick spectra at the equilibrium geometry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Error statistics and scalability of quantum error mitigation formulas

Quantum computing promises advantages over classical computing in many problems. Nevertheless, noise in quantum devices prevents most quantum algorithms from achieving the quantum advantage. Quantum error mitigation provides a variety of protocols to handle such noise using minimal qubit resources. While some of those protocols have been implemented in experiments for a few qubits, it remains unclear whether error mitigation will be effective in quantum circuits with tens to hundreds of qubits. In this paper, we apply statistics principles to quantum error mitigation and analyse the scaling behaviour of its intrinsic error. We find that the error increases linearly O(ϵN) with the gate number N before mitigation and sublinearly O(ϵ'N γ ) after mitigation, where γ ≈ 0.5, ϵ is the error rate of a quantum gate, and ϵ' is a protocol-dependent factor. The $\sqrt{N}$ scaling is a consequence of the law of large numbers, and it indicates that error mitigation can suppress the error by a larger factor in larger circuits. We propose the importance Clifford sampling as a key technique for error mitigation in large circuits to obtain this result.

97 MATHEMATICS AND COMPUTING↗

Zinc–hydrogen and zinc–iridium pairs in β-Ga 2 O 3

Zinc-doped monoclinic gallium oxide (β-Ga 2 O 3 :Zn) has semi-insulating properties that could make it a preferred material as a substrate for power devices. In this work, infrared and UV/Visible spectroscopy were used to investigate the defect properties of bulk β-Ga 2 O 3 :Zn crystals. As-grown crystals contain a single O-H stretching mode at 3486.7 cm -1 due to a neutral ZnH complex. A deuterium-annealed sample displays the corresponding O-D stretching mode at 2582.9 cm -1 , confirming the O-H assignment. A strong Ir 4+ electronic transition at 5147.6 cm -1 is also observed, along with sidebands attributed to ZnIr pairs. These sidebands show distinct differences compared with Mg-doped samples; most importantly, several peaks are attributed to Ir 4+ paired with a Zn on the tetrahedral Ga(I) site. Annealing under an oxygen atmosphere produced insulating material with a resistance above 1 TΩ.

36 MATERIALS SCIENCE↗

SDSS-IV MaNGA: 3D spin alignment of spiral and S0 galaxies

ABSTRACT We investigate the 3D spin alignment of galaxies with respect to the large-scale filaments using the MaNGA survey. The cosmic web is reconstructed from the Sloan Digital Sky Survey using disperse and the 3D spins of MaNGA galaxies are estimated using the thin disc approximation with integral field spectroscopy kinematics. Late-type spiral galaxies are found to have their spins parallel to the closest filament’s axis. The alignment signal is found to be dominated by low-mass spirals. Spins of S0-type galaxies tend to be oriented preferentially in perpendicular direction with respect to the filament’s axis. This orthogonal orientation is found to be dominated by S0s that show a notable misalignment between their kinematic components of stellar and ionized gas velocity fields and/or by low-mass S0s with lower rotation support compared to their high-mass counterparts. Qualitatively similar results are obtained when splitting galaxies based on the degree of ordered stellar rotation, such that galaxies with high spin magnitude have their spin aligned, and those with low spin magnitude in perpendicular direction to the filaments. In the context of conditional tidal torque theory, these findings suggest that galaxies’ spins retain memory of their larger scale environment. In agreement with measurements from hydrodynamical cosmological simulations, the measured signal at low redshift is weak, yet statistically significant. The dependence of the spin-filament orientation of galaxies on their stellar mass, morphology, and kinematics highlights the importance of sample selection to detect the signal.

Kraljic, Katarina↗

Importance of nonuniform Brillouin zone sampling for ab initio Bethe-Salpeter equation calculations of exciton binding energies in crystalline solids

Excitons are prevalent in semiconductors and insulators, and their binding energies are critical for optoelectronic applications. The state-of-the-art method for first-principles calculations of excitons in extended systems is the ab initio GW-Bethe-Salpeter equation (BSE) approach, which can require a fine sampling of reciprocal space to accurately resolve solid-state exciton properties. Here, in this study, we show, for a range of semiconductors and insulators, that the commonly employed approach of uniformly sampling the Brillouin zone can lead to underconverged exciton binding energies, as impractical grid sizes are required to achieve adequate convergence. We further show that nonuniform sampling of the Brillouin zone, focused on the region of reciprocal space where the exciton wave function resides, enables efficient rapid numerical convergence of exciton binding energies at a given level of theory. We propose a well-defined convergence procedure, which can be carried out at relatively low computational cost and which in some cases leads to a correction of previous best theoretical estimates by almost a factor of 2, qualitatively changing the predicted exciton physics. These results call for the adoption of nonuniform sampling methods for ab initio GW-BSE calculations and for revisiting previously computed values for exciton binding energies of many systems.

36 MATERIALS SCIENCE↗

Emulating ab initio computations of infinite nucleonic matter

We construct efficient emulators for the computation of the infinite nuclear matter equation of state. These emulators are based on the subspace-projected coupled-cluster method for which we here develop a new algorithm called small-batch voting to eliminate spurious states that might appear when emulating quantum many-body methods based on a non-Hermitian Hamiltonian. The efficiency and accuracy of these emulators facilitate a rigorous statistical analysis within which we explore nuclear matter predictions for > 10 6 different parametrizations of a chiral interaction model with explicit Δ -isobars at next-to-next-to leading order. Constrained by nucleon-nucleon scattering phase shifts and bound-state observables of light nuclei up to He 4 , we use history matching to identify nonimplausible domains for the low-energy coupling constants of the chiral interaction. Within these domains we perform a Bayesian analysis using sampling and importance resampling with different likelihood calibrations and study correlations between interaction parameters, calibration observables in light nuclei, and nuclear matter saturation properties. Published by the American Physical Society 2024

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗