Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image system design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Imaging corn plants with PhytoPET, a modular PET system for plant biology

PhytoPET is a modular positron emission tomography (PET) system designed specifically for plant imaging. The PhytoPET design allows flexible arrangements of PET detectors based on individual standalone detector modules built from single Hamamatsu H8500 position sensitive photomultiplier tubes and pixelated LYSO arrays. We have used the PhytoPET system to perform preliminary corn plant imaging studies at the Duke University Biology Department Phytotron. Initial evaluation of the PhytoPET system to image the biodistribution of the positron emitting tracer {sup 11}C in corn plants is presented. {sup 11}CO{sub 2} is loaded into corn seedlings by a leaf-labeling cuvette and translocation of {sup 11}C-sugars is imaged by a flexible arrangement of PhytoPET modules on each side. The PhytoPET system successfully images {sup 11}C within corn plants and allows for the dynamic measurement of {sup 11}C-sugar translocation from the leaf to the roots.

59 BASIC BIOLOGICAL SCIENCES↗

A double photomultiplier Compton camera and its readout system for mice imaging

We have designed a Compton Camera (CC) to image the bio-distribution of gamma-emitting radiopharmaceuticals in mice. A CC employs the 'electronic collimation', i.e. a technique that traces the gamma-rays instead of selecting them with physical lead or tungsten collimators. To perform such a task, a CC measures the parameters of the Compton interaction that occurs in the device itself. At least two detectors are required: one (tracker), where the primary gamma undergoes a Compton interaction and a second one (calorimeter), in which the scattered gamma is completely absorbed. Eventually the polar angle and hence a 'cone' of possible incident directions are obtained (event with 'incomplete geometry'). Different solutions for the two detectors are proposed in the literature: our design foresees two similar Position Sensitive Photomultipliers (PMT, Hamamatsu H8500). Each PMT has 64 output channels that are reduced to 4 using a charge multiplexed readout system, i.e. a Series Charge Multiplexing net of resistors. Triggering of the system is provided by the coincidence of fast signals extracted at the last dynode of the PMTs. Assets are the low cost and the simplicity of design and operation, having just one type of device; among drawbacks there is a lower resolution with respect to more sophisticated trackers and full 64 channels Readout. This paper does compare our design of our two-Hamamatsu CC to other solutions and shows how the spatial and energy accuracy is suitable for the inspection of radioactivity in mice.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of the high-resolution soft X-ray imaging system on the Joint Texas Experimental Tokamak

A new soft X-ray diagnostic system has been designed on the Joint Texas Experimental Tokamak (J-TEXT) aiming to observe and survey the magnetohydrodynamic (MHD) activities. The system consists of five cameras located at the same toroidal position. Each camera has 16 photodiode elements. Three imaging cameras view the internal plasma region (r/a < 0.7) with a spatial resolution about 2 cm. By tomographic method, heat transport outside from the 1/1 mode X-point during the sawtooth collapse is found. The other two cameras with a higher spatial resolution 1 cm are designed for monitoring local MHD activities respectively in plasma core and boundary.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Small Interactive Image Processing System (SMIPS) users manual

The Small Interactive Image Processing System (SMIP) is designed to facilitate the acquisition, digital processing and recording of image data as well as pattern recognition in an interactive mode. Objectives of the system are ease of communication with the computer by personnel who are not expert programmers, fast response to requests for information on pictures, complete error recovery as well as simplification of future programming efforts for extension of the system. The SMIP system is intended for operation under OS/MVT on an IBM 360/75 or 91 computer equipped with the IBM-2250 Model 1 display unit. This terminal is used as an interface between user and main computer. It has an alphanumeric keyboard, a programmed function keyboard and a light pen which are used for specification of input to the system. Output from the system is displayed on the screen as messages and pictures.

Moik, J. G.↗

Information theoretical assessment of image gathering and coding for digital restoration

The process of image-gathering, coding, and restoration is presently treated in its entirety rather than as a catenation of isolated tasks, on the basis of the relationship between the spectral information density of a transmitted signal and the restorability of images from the signal. This 'information-theoretic' assessment accounts for the information density and efficiency of the acquired signal as a function of the image-gathering system's design and radiance-field statistics, as well as for the information efficiency and data compression that are obtainable through the combination of image gathering with coding to reduce signal redundancy. It is found that high information efficiency is achievable only through minimization of image-gathering degradation as well as signal redundancy.

Huck, Friedrich O.↗

Reconstructing irregularly sampled images by neural networks

Neural-network-like models of receptor position learning and interpolation function learning are being developed as models of how the human nervous system might handle the problems of keeping track of the receptor positions and interpolating the image between receptors. These models may also be of interest to designers of image processing systems desiring the advantages of a retina-like image sampling array.

Ahumada, Albert J., Jr.↗

SU-E-J-49: Design and Fabrication of Custom 3D Printed Phantoms for Radiation Therapy Research and Quality Assurance

Purpose The rapid proliferation of affordable 3D printing techniques has enabled the custom fabrication of items ranging from paper weights to medical implants. This study investigates the feasibility of utilizing the technology for developing novel phantoms for use in radiation therapy quality assurance (QA) procedures. Methods A phantom for measuring the geometric parameters of linear accelerator (LINAC) on-board imaging (OBI) systems was designed using SolidWorks. The design was transferred to a 3D printer and fabricated using a fused deposition modeling (FDM) technique. Fiducials were embedded in the phantom by placing 1.6 mm diameter steel balls in predefined holes and securing them with silicone. Several MV and kV images of the phantom were collected and the visibility and geometric accuracy were evaluated. A second phantom, for use in the experimental evaluation of a high dose rate (HDR) brachytherapy dosimeter, was designed to secure several applicator needles in water. The applicator was fabricated in the same 3D printer and used for experiments. Results The general accuracy of printed parts was determined to be 0.1 mm. The cost of materials for the imaging and QA phantoms were $22 and $5 respectively. Both the plastic structure and fiducial markers of the imaging phantom were visible in MV and kV images. Fiducial marker locations were determined to be within 1mm of desired locations, with the discrepancy being attributed to the fiducial attachment process. The HDR phantom secured the applicators within 0.5 mm of the desired locations. Conclusion 3D printing offers an inexpensive method for fabricating custom phantoms for use in radiation therapy quality assurance. While the geometric accuracy of such parts is limited compared to more expensive methods, the phantoms are still highly functional and provide a unique opportunity for rapid fabrication of custom phantoms for use in radiation therapy QA and research.

07 ISOTOPE AND RADIATION SOURCES↗

Synthetic aperture microwave imaging with active probing for fusion plasma diagnostics

A Synthetic Aperture Microwave Imaging (SAMI) system has been designed and built to obtain 2-D images at several frequencies from fusion plasmas. SAMI uses a phased array of linearly polarised antennas. The array configuration has been optimised to achieve maximum synthetic aperture beam efficiency. The signals received by antennas are down-converted to the intermediate frequency range and then recorded in a full vector form. Full vector signals allow beam focusing and image reconstruction in both real time and a post-processing mode. SAMI can scan over 16 pre-programmed frequencies in the range of 10-35GHz with a switching time of 300ns. The system operates in 2 different modes simultaneously: both a 'passive' imaging of plasma emission and also an 'active' imaging of the back-scattered signal of the radiation launched by one of the antennas from the same array. This second mode is similar to so-called Doppler backscattering (DBS) reflectometry with 2-D resolution of the propagation velocity of turbulent structures. Both modes of operation show good performance in fusion plasma experiments on Mega Amp Spherical Tokamak (MAST). We have obtained the first ever 2-D images of BXO mode conversion windows. With active probing, first ever turbulence velocity maps have been obtained. We present an overview of the diagnostic and discuss recent results. In contrast to quasi-optical microwave imaging systems SAMI requires neither big aperture viewing ports nor large 2-D detector arrays to achieve the desired imaging resolution. The number of effective 'pixels' of the synthesized image is proportional to the number of receiving antennas squared. Thus only a small number of optimised antennas is sufficient for the majority of applications. Possible implementation of SAMI on ITERand DEMO is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of optimal collimation for dedicated molecular breast imaging systems

Molecular breast imaging (MBI) is a functional imaging technique that uses specialized small field-of-view gamma cameras to detect the preferential uptake of a radiotracer in breast lesions. MBI has potential to be a useful adjunct method to screening mammography for the detection of occult breast cancer. However, a current limitation of MBI is the high radiation dose (a factor of 7-10 times that of screening mammography) associated with current technology. The purpose of this study was to optimize the gamma camera collimation with the aim of improving sensitivity while retaining adequate resolution for the detection of sub-10-mm lesions. Square-hole collimators with holes matched to the pixilated cadmium zinc telluride detector elements of the MBI system were designed. Data from MBI patient studies and parameters of existing dual-head MBI systems were used to guide the range of desired collimator resolutions, source-to-collimator distances, pixel sizes, and collimator materials that were examined. General equations describing collimator performance for a conventional gamma camera were used in the design process along with several important adjustments to account for the specialized imaging geometry of the MBI system. Both theoretical calculations and a Monte Carlo model were used to measure the geometric efficiency (or sensitivity) and resolution of each designed collimator. Results showed that through optimal collimation, collimator sensitivity could be improved by factors of 1.5-3.2, while maintaining a collimator resolution of either {<=}5 or {<=}7.5 mm at a distance of 3 cm from the collimator face. These gains in collimator sensitivity permit an inversely proportional drop in the required dose to perform MBI.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Design and implementation of a home-built imaging system with low jitter for cold atom experiments

A novel home-built system for imaging cold atom samples is presented using a readily available astronomy camera which has the requisite sensitivity but no timing-control. We integrate the camera with LabVIEW achieving fast, low-jitter imaging with a convenient user-defined interface. We show that our system takes precisely timed millisecond exposures and offers significant improvements in terms of system jitter and readout time over previously reported home-built systems. Our system rivals current commercial “black box” systems in performance and user-friendliness.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Clinical implementation of radiosurgery using the Helical TomoTherapy unit

The American Society of Radiation Oncology has recently recommended the use of radiosurgery to manage brain metastases. For such a recommendation to be implemented in a widespread manner, radiosurgery must be accessible at community radiation therapy facilities. The work presented here describes our clinical experience in the implementation of radiosurgery using a Helical TomoTherapy unit. Helical TomoTherapy is a unique dose-delivery system designed to perform intensity-modulated radiation therapy (IMRT). The system built on the ring-based gantry has the tight machine tolerances required for radiosurgery. A frameless system consisting of a thermoplastic mask and a noninvasive ''stereotactic radiosurgery (SRS)-stereotactic radiotherapy (SRT)'' fixation device is used for patient immobilization. Treatment planning is performed using the TomoHD treatment planning system designed for IMRT. The image-guidance system on the Helical TomoTherapy is used for patient localization. Our clinical experience demonstrated that the radiosurgery procedure can be streamlined as we do for IMRT patients. The treatment time of about 10 minutes is comparable with that for IMRT patients. The same patient-specific quality assurance for IMRT is used for radiosurgery. As demonstrated, SRS using Helical TomoTherapy is not a whole-day event, unlike SRS using other dose-delivery systems or SRS performed in the past.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MO-FG-209-02: Development of a Virtual Breast Phantom From a Multi-Modality Perspective

This symposium will review recent advances in the simulation methods for evaluation of novel breast imaging systems – the subject of AAPM Task Group TG234. Our focus will be on the various approaches to development and validation of software anthropomorphic phantoms and their use in the statistical assessment of novel imaging systems using such phantoms along with computational models for the x-ray image formation process. Due to the dynamic development and complex design of modern medical imaging systems, the simulation of anatomical structures, image acquisition modalities, and the image perception and analysis offers substantial benefits of reduced cost, duration, and radiation exposure, as well as the known ground-truth and wide variability in simulated anatomies. For these reasons, Virtual Clinical Trials (VCTs) have been increasingly accepted as a viable tool for preclinical assessment of x-ray and other breast imaging methods. Activities of TG234 have encompassed the optimization of protocols for simulation studies, including phantom specifications, the simulated data representation, models of the imaging process, and statistical assessment of simulated images. The symposium will discuss the state-of-the-science of VCTs for novel breast imaging systems, emphasizing recent developments and future directions. Presentations will discuss virtual phantoms for intermodality breast imaging performance comparisons, extension of the breast anatomy simulation to the cellular level, optimized integration of the simulated imaging chain, and the novel directions in the observer models design. Learning Objectives: Review novel results in developing and applying virtual phantoms for inter-modality breast imaging performance comparisons; Discuss the efforts to extend the computer simulation of breast anatomy and pathology to the cellular level; Summarize the state of the science in optimized integration of modules in the simulated imaging chain; Compare novel directions in the design of observer models for task based validation of imaging systems. PB: Research funding support from the NIH, NSF, and Komen for the Cure; NIH funded collaboration with Barco, Inc. and Hologic, Inc.; Consultant to Delaware State Univ. and NCCPM, UK. AA: Employed at Barco Healthcare.; P. Bakic, NIH: (NIGMS P20 #GM103446, NCI R01 #CA154444); M. Das, NIH Research grants.

60 APPLIED LIFE SCIENCES↗

MO-FG-209-05: Towards a Feature-Based Anthropomorphic Model Observer

This symposium will review recent advances in the simulation methods for evaluation of novel breast imaging systems – the subject of AAPM Task Group TG234. Our focus will be on the various approaches to development and validation of software anthropomorphic phantoms and their use in the statistical assessment of novel imaging systems using such phantoms along with computational models for the x-ray image formation process. Due to the dynamic development and complex design of modern medical imaging systems, the simulation of anatomical structures, image acquisition modalities, and the image perception and analysis offers substantial benefits of reduced cost, duration, and radiation exposure, as well as the known ground-truth and wide variability in simulated anatomies. For these reasons, Virtual Clinical Trials (VCTs) have been increasingly accepted as a viable tool for preclinical assessment of x-ray and other breast imaging methods. Activities of TG234 have encompassed the optimization of protocols for simulation studies, including phantom specifications, the simulated data representation, models of the imaging process, and statistical assessment of simulated images. The symposium will discuss the state-of-the-science of VCTs for novel breast imaging systems, emphasizing recent developments and future directions. Presentations will discuss virtual phantoms for intermodality breast imaging performance comparisons, extension of the breast anatomy simulation to the cellular level, optimized integration of the simulated imaging chain, and the novel directions in the observer models design. Learning Objectives: Review novel results in developing and applying virtual phantoms for inter-modality breast imaging performance comparisons; Discuss the efforts to extend the computer simulation of breast anatomy and pathology to the cellular level; Summarize the state of the science in optimized integration of modules in the simulated imaging chain; Compare novel directions in the design of observer models for task based validation of imaging systems. PB: Research funding support from the NIH, NSF, and Komen for the Cure; NIH funded collaboration with Barco, Inc. and Hologic, Inc.; Consultant to Delaware State Univ. and NCCPM, UK. AA: Employed at Barco Healthcare.; P. Bakic, NIH: (NIGMS P20 #GM103446, NCI R01 #CA154444); M. Das, NIH Research grants.

60 APPLIED LIFE SCIENCES↗

UT-NE Radiation Instrumentation Research Group Meeting: An Update on Progress

The purpose of this project is to design a system to image large and/or thick objects with high dynamic ranges using an intensified, charge coupled device (CCD) camera and a fast-pulsed, high energy neutron source; Improve image resolution by reducing scatter; and Design ultra-fast scintillator using nanotechnology to allow for better timing (and thus better scatter rejection).

07 ISOTOPE AND RADIATION SOURCES↗

MO-FG-303-01: FEATURED PRESENTATION and BEST IN PHYSICS (THERAPY): Automating LINAC QA: Design and Testing of An Image Acquisition and Processing System Utilizing a Combination of Radioluminescent Phosphors, Embedded X-Ray Markers and Optical Measurements

Purpose: The recent development of phosphors to visualize radiation beams from linear accelerators (LINAC) offers a unique opportunity for evaluating radiation fields within the context of the treatment space. The purpose of this study was to establish an automated, self-calibrating prototype system for performing quality assurance (QA) measurements. Methods: A thin layer of Gd{sub 2}O{sub 2}S:Tb phosphor and fiducial markers were embedded on several planar faces of a custom-designed phantom. The phantom was arbitrarily placed near iso-center on the couch of a LINAC equipped with on-board megavoltage (MV) and kilovoltage (kV) imagers. A plan consisting of several beams and integrated image acquisitions was delivered. Images of the phantom were collected throughout the delivery. Salient features, such as fiducials, crosshairs and beam edges were then extracted from these images used to calibrate the system, adjust for variations in phantom placement, and perform measurements. Beam edges were visualized by imaging the light generated by the phosphor on the phantom enabling direct comparison with the light field and laser locations. Registration of MV, kV and optical image data was performed using the embedded fiducial markers, enabling comparison of imaging center locations. Measurements specified by TG-142 were calculated and compared with those obtained from a commercially available QA system. Results: The system was able to automatically extract the location of the fiducials, lasers, light field and radiation field from the acquired images regardless of phantom positioning. It was also able to automatically identify the locations of fiducial markers on kV and MV images. All collected measurements were within TG-142 guidelines. The difference between the prototype and commercially available system were less than 0.2 mm. Conclusion: The prototype system demonstrated the capability of accurately and autonomously evaluating various TG-142 parameters independent of operator input and phantom setup.

60 APPLIED LIFE SCIENCES↗