Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image quality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

SU-E-T-208: Comparison of MR Image Quality of Various Brachytherapy Applicators for Cervical Cancer

Purpose: To compare the quality of Magnetic Resonance (MR) images of a recently-proposed novel direction-modulated brachytherapy (DMBT) tandem applicator against two conventional clinical applicators, using the current MRI clinical protocol. Methods: Three tandem applicators were compared: (1) tungsten-based DMBT applicator, (2) conventional plastic applicator and (3) conventional stainless steel applicator. Physical dimensions were 5.4, 3.8 and 3.2 for tandems (1), (2) and (3), respectively. Each applicator was placed in the same water-phantom and independently scanned using the same parameters and coil settings on a 1.5 T 450w GE scanner. Images were acquired using T2-weighted turbo-spin-echo (TSE) with 8-channel body coil. Acquisition parameters were TR/TE =7000/108 ms; acquisition matrix = 320 x 256; 30 slices with 4 mm thickness and 0.5 gap; pixel bandwidth = 122 Hz and voxel size = 0.5 x 0.625 mm2 and number of excitations (NEX) = 4. Multiple acquisitions were obtained in para-sagittal and para-axial views (with respect to the tandem axis) for each applicator. Diameters of the tandem were measured at multiple angles and multiple locations and compared to the physical dimensions of the corresponding tandems. Results: Minimal susceptibility artifact was observed with the DMBT and the plastic tandems. The stainless steel tandem produced significantly larger artifact than the first two tandems. The average diameter of the DMBT applicator measured 5.94 ± 0.3 mm. The average diameter of the plastic tandem measured 3.9 ± 0.1 mm. The maximum extent of artifact was 1.5 mm and 0.7 mm for DMBT and plastic tandems, respectively. The susceptibility artifact induced by the stainless steel tandem prevented the measurement of its diameter, and the edges of the tandem could not be identified in any acquisition. Conclusion: This work demonstrated that the plastic and the tungsten-based DMBT tandem applicators are both suitable for MRI-guided brachytherapy of cervical cancer.

60 APPLIED LIFE SCIENCES↗

Limiting Magnitude, τ, t eff , and Image Quality in DES Year 1

The Dark Energy Survey (DES) is an astronomical imaging survey being completed with the DECam imager on the Blanco telescope at CTIO. After each night of observing, the DES data management (DM) group performs an initial processing of that night's data, and uses the results to determine which exposures are of acceptable quality, and which need to be repeated. The primary measure by which we declare an image of acceptable quality is $\tau$, a scaling of the exposure time. This is the scale factor that needs to be applied to the open shutter time to reach the same photometric signal to noise ratio for faint point sources under a set of canonical good conditions. These conditions are defined to be seeing resulting in a PSF full width at half maximum (FWHM) of 0.9" and a pre-defined sky brightness which approximates the zenith sky brightness under fully dark conditions. Point source limiting magnitude and signal to noise should therefore vary with t in the same way they vary with exposure time. Measurements of point sources and $\tau$ in the first year of DES data confirm that they do. In the context of DES, the symbol $t_{eff}$ and the expression "effective exposure time" usually refer to the scaling factor, $\tau$, rather than the actual effective exposure time; the "effective exposure time" in this case refers to the effective duration of one second, rather than the effective duration of an exposure.

79 ASTRONOMY AND ASTROPHYSICS↗

WE-AB-206-01: Diagnostic Ultrasound Imaging Quality Assurance

The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. The goal of this ultrasound hands-on workshop is to demonstrate quality control (QC) testing in diagnostic ultrasound and to provide updates in ACR ultrasound accreditation requirements. The first half of this workshop will include two presentations reviewing diagnostic ultrasound QA/QC and ACR ultrasound accreditation requirements. The second half of the workshop will include live demonstrations of basic QC tests. An array of ultrasound testing phantoms and ultrasound scanners will be available for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations and on-site instructors. The targeted attendees are medical physicists in diagnostic imaging. Learning Objectives: Gain familiarity with common elements of a QA/QC program for diagnostic ultrasound imaging dentify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools Learn ACR ultrasound accreditation requirements Jennifer Walter is an employee of American College of Radiology on Ultrasound Accreditation.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-D-BRF-03: Improvement of TomoTherapy Megavoltage Topogram Image Quality for Automatic Registration During Patient Localization

Purpose: To improve the quality of mega-voltage orthogonal scout images (MV topograms) for a fast and low-dose alternative technique for patient localization on the TomoTherapy HiART system. Methods: Digitally reconstructed radiographs (DRR) of anthropomorphic head and pelvis phantoms were synthesized from kVCT under TomoTherapy geometry (kV-DRR). Lateral (LAT) and anterior-posterior (AP) aligned topograms were acquired with couch speeds of 1cm/s, 2cm/s, and 3cm/s. The phantoms were rigidly translated in all spatial directions with known offsets in increments of 5mm, 10mm, and 15mm to simulate daily positioning errors. The contrast of the MV topograms was automatically adjusted based on the image intensity characteristics. A low-pass fast Fourier transform filter removed high-frequency noise and a Weiner filter reduced stochastic noise caused by scattered radiation to the detector array. An intensity-based image registration algorithm was used to register the MV topograms to a corresponding kV-DRR by minimizing the mean square error between corresponding pixel intensities. The registration accuracy was assessed by comparing the normalized cross correlation coefficients (NCC) between the registered topograms and the kV-DRR. The applied phantom offsets were determined by registering the MV topograms with the kV-DRR and recovering the spatial translation of the MV topograms. Results: The automatic registration technique provided millimeter accuracy and was robust for the deformed MV topograms for three tested couch speeds. The lowest average NCC for all AP and LAT MV topograms was 0.96 for the head phantom and 0.93 for the pelvis phantom. The offsets were recovered to within 1.6mm and 6.5mm for the processed and the original MV topograms respectively. Conclusion: Automatic registration of the processed MV topograms to a corresponding kV-DRR recovered simulated daily positioning errors that were accurate to the order of a millimeter. These results suggest the clinical use of MV topograms as a promising alternative to MVCT patient alignment.

60 APPLIED LIFE SCIENCES↗

Image quality measures and their performance

A number of quality measures are evaluated for gray scale image compression. They are all bivariate exploiting the differences between corresponding pixels in the original and degraded images. It is shown that although some numerical measures correlate well with the observers' response for a given compression technique, they are not reliable for an evaluation across different techniques. The two graphical measures (histograms and Hosaka plots), however, can be used to appropriately specify not only the amount, but also the type of degradation in reconstructed images.

Eskicioglu, Ahmet M.↗

Characterization of LANDSAT-4 TM and MSS Image Quality for Interpretation of Agricultural and Forest Resources

Systematic analysis of both image and numeric data shows that the overall spectral, spatial, and radiometric quality of the TM data are excellent. Spectral variations in fallow fields are due to the vaiability in soil moisture and surface roughness resulting from the various stages of field preparation for small grains production. Spectrally, the addition of the first TM short wave infrared band (Band 5) significantly enhanced ability to discriminate different crop types. Bands 1, 5, and 6 contain saturated pixels due to high albedo effects, low moisture conditions, and high radiant temperatures of granite and dry, bare soil on south facing slopes, respectively. Spatially, the two fold decrease in interpixel distance and four fold decrease in area per pixel between the TM and MSS allow for improved discrimination of small fields, boundary conditions, road and stream networks in rough terrain, and small forest clearings resulting from various forest management practices.

Degloria, S. D.↗

Image quality on the Kuiper Airborne Observatory. I - Results of the first flight series

The NASA Kuiper Airborne Observatory (KAO) was flown three times during June and July, 1984 in order to study the causes of the poor seeing obtained with the 0.9-m telescope. High-speed pressure and temperature sensors were placed in the telescope cavity. Several thousand stellar images were recorded under various flight and optical configurations. It is found that the long-exposure image size is affected by telescope tracking errors, imperfect optics, poor optical alignment, telescope and instrument vibration, thermal fluctuations in the telescope cavity, and density fluctuations in the shear layer that forms the boundary between the cavity air and outside air. Possible ways to improve the quality of the images are discussed.

Elliot, J. L.↗

Dependence of Adaptive Cross-correlation Algorithm Performance on the Extended Scene Image Quality

Recently, we reported an adaptive cross-correlation (ACC) algorithm to estimate with high accuracy the shift as large as several pixels between two extended-scene sub-images captured by a Shack-Hartmann wavefront sensor. It determines the positions of all extended-scene image cells relative to a reference cell in the same frame using an FFT-based iterative image-shifting algorithm. It works with both point-source spot images as well as extended scene images. We have demonstrated previously based on some measured images that the ACC algorithm can determine image shifts with as high an accuracy as 0.01 pixel for shifts as large 3 pixels, and yield similar results for both point source spot images and extended scene images. The shift estimate accuracy of the ACC algorithm depends on illumination level, background, and scene content in addition to the amount of the shift between two image cells. In this paper we investigate how the performance of the ACC algorithm depends on the quality and the frequency content of extended scene images captured by a Shack-Hatmann camera. We also compare the performance of the ACC algorithm with those of several other approaches, and introduce a failsafe criterion for the ACC algorithm-based extended scene Shack-Hatmann sensors.

wave-front sensing and control↗

MO-AB-210-00: Diagnostic Ultrasound Imaging Quality Control and High Intensity Focused Ultrasound Therapy Hands-On Workshop

The goal of this ultrasound hands-on workshop is to demonstrate advancements in high intensity focused ultrasound (HIFU) and to demonstrate quality control (QC) testing in diagnostic ultrasound. HIFU is a therapeutic modality that uses ultrasound waves as carriers of energy. HIFU is used to focus a beam of ultrasound energy into a small volume at specific target locations within the body. The focused beam causes localized high temperatures and produces a well-defined regions of necrosis. This completely non-invasive technology has great potential for tumor ablation and targeted drug delivery. At the workshop, attendees will see configurations, applications, and hands-on demonstrations with on-site instructors at separate stations. The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. At the workshop, an array of ultrasound testing phantoms and ultrasound scanners will be provided for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations of the techniques. Target audience: Medical physicists and other medical professionals in diagnostic imaging and radiation oncology with interest in high-intensity focused ultrasound and in diagnostic ultrasound QC. Learning Objectives: Learn ultrasound physics and safety for HIFU applications through live demonstrations Get an overview of the state-of-the art in HIFU technologies and equipment Gain familiarity with common elements of a quality control program for diagnostic ultrasound imaging Identify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools List of supporting vendors for HIFU and diagnostic ultrasound QC hands-on workshop: Philips Healthcare Alpinion Medical Systems Verasonics, Inc Zonare Medical Systems, Inc Computerized Imaging Reference Systems (CIRS), Inc. GAMMEX, Inc., Cablon Medical BV Steffen Sammet: NIH/NCI grant 5R25CA132822, NIH/NINDS grant 5R25NS080949 and Philips Healthcare research grant C32.

60 APPLIED LIFE SCIENCES↗

Evoluation of Landsat-4 image quality for the interpretation of forest, agricultural and soil resources

Landsat-4 Multispectral Scanner (MSS) and Thematic Mapper (TM) sensor performance is being evaluated through the analysis of images generated by computer-compatible tape data and commercially available film products. Natural targets are used to evaluate spectral variability, spatial resolution, radiometric sensitivity, and geometric fidelity. Spectral characteristics are being evaluated through the interpretation of the image tone and texture variability of known features, while spatial characteristics are evaluated through lineal and areal estimates of similar features and the plotting and analysis of residual errors derived from regressions between relative image coordinates and map coordinates.

Degloria, S. D.↗

Evaluation of image quality

This presentation outlines in viewgraph format a general approach to the evaluation of display system quality for aviation applications. This approach is based on the assumption that it is possible to develop a model of the display which captures most of the significant properties of the display. The display characteristics should include spatial and temporal resolution, intensity quantizing effects, spatial sampling, delays, etc. The model must be sufficiently well specified to permit generation of stimuli that simulate the output of the display system. The first step in the evaluation of display quality is an analysis of the tasks to be performed using the display. Thus, for example, if a display is used by a pilot during a final approach, the aesthetic aspects of the display may be less relevant than its dynamic characteristics. The opposite task requirements may apply to imaging systems used for displaying navigation charts. Thus, display quality is defined with regard to one or more tasks. Given a set of relevant tasks, there are many ways to approach display evaluation. The range of evaluation approaches includes visual inspection, rapid evaluation, part-task simulation, and full mission simulation. The work described is focused on two complementary approaches to rapid evaluation. The first approach is based on a model of the human visual system. A model of the human visual system is used to predict the performance of the selected tasks. The model-based evaluation approach permits very rapid and inexpensive evaluation of various design decisions. The second rapid evaluation approach employs specifically designed critical tests that embody many important characteristics of actual tasks. These are used in situations where a validated model is not available. These rapid evaluation tests are being implemented in a workstation environment.

Pavel, M.↗

SU-F-J-117: Impact of Motion Artifacts On Image Quality and Accuracy of Tumor Motion Reconstruction in 4D CT-On-Rails and MV-CBCT Scans: A Phantom Study

Purpose: To compare and quantify respiratory motion artifacts in images from free breathing 4D-CT-on-Rails(CTOR) and those from MV-Cone-beam-CT(MVCB) and facilitate respiratory motion guided radiation therapy. Methods: 4D-CTOR: Siemens Somatom CT-on-Rails system with Anzai belt loaded with pressure sensor load cells. 4D scans were performed in helical mode, pitch 0.1, gantry rotation time 0.5s, 1.5mm slice thickness, 120kVp, 400 mAs. Normal and fast breathing (>12rpm) scanning protocols were investigated. Helical scan, AIP(average intensity projection) and MIP(maximum intensity projection) were generated from 4D-CTOR scans with amplitude sorting into 10 phases.MVCB: Siemens Artiste diamond view(1MV)MVCB was performed with 5MU thorax protocol with 60 second of full rotation.Phantom: Anzai AZ-733V respiratory phantom. The settings were set to normal and resp. modes with repetition rates at 15 rpm and 10 rpm. Surgical clips, acrylic, wooden, rubber and lung density, total six mock-ups were scanned and compared in this study.Signal-to-noise ratio(SNR), contrast-to-noise ratio(CNR) and reconstructed motion volume were compared to different respiratory setups for the mock-ups. Results: Reconstructed motion volume was compared to the real object volume for the six test mock-ups. It shows that free breathing helical in all instances underestimates the object excursions largest to −67.4% and least −6.3%. Under normal breathing settings, MIP can predict very precise motion volume with minimum 0.4% and largest −13.9%. MVCB shows underestimate of the motion volume with −1.11% minimum and −18.0% maximum. With fast breathing, AIP provides bad representation of the object motion; however, the MIP can predict the motion volume with −2.0% to −11.4% underestimate. Conclusion: Respiratory motion guided radiation therapy requires good motion recording. This study shows that regular CTOR helical scans provides bad guidance, 4D CTOR AIP cannot represent the fast breathing pattern, MIP can represent the best motion volume, MVCBCT can only be used for normal breathing with acceptable uncertainties.

60 APPLIED LIFE SCIENCES↗

Computational and human observer image quality evaluation of low dose, knowledge-based CT iterative reconstruction

Purpose: Aims in this study are to (1) develop a computational model observer which reliably tracks the detectability of human observers in low dose computed tomography (CT) images reconstructed with knowledge-based iterative reconstruction (IMR™, Philips Healthcare) and filtered back projection (FBP) across a range of independent variables, (2) use the model to evaluate detectability trends across reconstructions and make predictions of human observer detectability, and (3) perform human observer studies based on model predictions to demonstrate applications of the model in CT imaging. Methods: Detectability (d′) was evaluated in phantom studies across a range of conditions. Images were generated using a numerical CT simulator. Trained observers performed 4-alternative forced choice (4-AFC) experiments across dose (1.3, 2.7, 4.0 mGy), pin size (4, 6, 8 mm), contrast (0.3%, 0.5%, 1.0%), and reconstruction (FBP, IMR), at fixed display window. A five-channel Laguerre–Gauss channelized Hotelling observer (CHO) was developed with internal noise added to the decision variable and/or to channel outputs, creating six different internal noise models. Semianalytic internal noise computation was tested against Monte Carlo and used to accelerate internal noise parameter optimization. Model parameters were estimated from all experiments at once using maximum likelihood on the probability correct, P{sub C}. Akaike information criterion (AIC) was used to compare models of different orders. The best model was selected according to AIC and used to predict detectability in blended FBP-IMR images, analyze trends in IMR detectability improvements, and predict dose savings with IMR. Predicted dose savings were compared against 4-AFC study results using physical CT phantom images. Results: Detection in IMR was greater than FBP in all tested conditions. The CHO with internal noise proportional to channel output standard deviations, Model-k4, showed the best trade-off between fit and model complexity according to AIC{sub c}. With parameters fixed, the model reasonably predicted detectability of human observers in blended FBP-IMR images. Semianalytic internal noise computation gave results equivalent to Monte Carlo, greatly speeding parameter estimation. Using Model-k4, the authors found an average detectability improvement of 2.7 ± 0.4 times that of FBP. IMR showed greater improvements in detectability with larger signals and relatively consistent improvements across signal contrast and x-ray dose. In the phantom tested, Model-k4 predicted an 82% dose reduction compared to FBP, verified with physical CT scans at 80% reduced dose. Conclusions: IMR improves detectability over FBP and may enable significant dose reductions. A channelized Hotelling observer with internal noise proportional to channel output standard deviation agreed well with human observers across a wide range of variables, even across reconstructions with drastically different image characteristics. Utility of the model observer was demonstrated by predicting the effect of image processing (blending), analyzing detectability improvements with IMR across dose, size, and contrast, and in guiding real CT scan dose reduction experiments. Such a model observer can be applied in optimizing parameters in advanced iterative reconstruction algorithms as well as guiding dose reduction protocols in physical CT experiments.

60 APPLIED LIFE SCIENCES↗

Characterization of LANDSAT-4 TM and MSS Image Quality for the Interpretation of California's Agricultural Resources

The quality of LANDSAT-4 MSS and TM data was determined by analyzing TM spectral and spatial performance in terms of spectral variability of natural targets and the TM-ground instantaneous field-of-view (IFOV) variability in level and mountainous terrain; and by assessing the suitability of TM and MSS image products for characterizing renewable resourse features. The TM data should be extremelly valuable for crop type and area proportion estimation; undating agricultural land use survey maps at 1:24,000 scale and smaller, field boundary definition; and determining the size and location of individual farmsteads. Ongoing research activities are focused on making spectral and spatial analyses of both MSS and TM analytical film products. The improved spectral, spatial, and radiometric quality of the TM data, should promote a renewed emphasis and interest in direct visual interpretation of these image products, both for updating and improving land stratification in support of resource inventory and for enhancing the image analyst's contribution to computer-assisted analysis procedures.

Degloria, S. D.↗

Image Quality on the KAO

Three flights of the Kuiper Airborne Observatory (KAO) were taken to study the cause of the point spread function (PSF) degradation. The preliminary conclusions are: (1) the KAO point spread function decreases in size with elapsed time at altitude; (2) image motion is occasionally comparable to the size of the image, but is usually a sub-arcsecond effect; and (3) star images show small scale internal structural changes on a 200 microsecond timescale.

Dunham, E. W.↗