At least 163 records · Page 9

Low-noise video amplifiers for imaging CCD's

Various techniques were developed which enable the CCD (charge coupled device) imaging array user to obtain optimum performance from the device. A CCD video channel was described, and detector-preamplifier interface requirements were examined. A noise model for the system was discussed at length and laboratory data presented and compared to predicted results.

Scinicariello, F.↗

A CCD System for Photometry of Direct and Spectroscopic Images

A charge-coupled device (CCD) for direct imagery at the focus of a ground-based telescope and for high dispersion spectroscopy of stars is evaluated. The CCD is an RCA SID 53612 thinned, buried channel array of 512x320 30-micron square pixels that are back-illuminated and refrigerated to about -60 C in a rugged, RF-shielded vacuum housing. The double-correlated sampling (integrator) readout system, the Z80 microprocessor readout control system, and the data collection system are described. The readout noise is 120 electron-hole pairs (ehp) per pixel per readout, the thermal dark current is 50 ehp/pixel/sec, and the scale of the 12-bit analog-to-digital converter is 25 ehp/AD unit. Unique features of this system are compared to other astronomical implementations of the same model of CCD.

Frecker, J. E.↗

SAW-Modulated Image Device

Imaging device uses surface-acoustic-wave (SAW) charge transfer for image readout. Spatial resolution of image changed electronically by changing frequency of applied signal. Surface acoustic waves create traveling longitudinal electric fields. These fields create potential wells that carry along stored charges. Charges injected into wells by photoelectric conversion when light strikes device.

Benz, H. F.↗

Physics and design of advanced IR bolometers and photoconductors

The state-of-the-art in photoconductors and bolometers is reviewed, centering on the materials development and concepts of extrinsic Si and Ge devices. It is suggested that in the field of 2-D detector arrays the hybrid circuits containing a photoconductor or a photodiode array, bonded with In solder to a switched MOS readout device with up to 60 x 60 elements, will produce superior performance. Other systems discussed include charge-coupled devices, developed for visible-light imaging and adapted to IR imaging, and charge-injection devices, a monolithic combination of a standard photoconductor and a metal-insulator-semiconductor capacitor. Finally, it is pointed out that a nonequilibrium theory of bolometer noise demonstrates the possibility of reducing the traditionally accepted noise limits by 60 percent for Johnson noise and 30 percent for the noise from phonons in the thermal link of the bolometer.

Haller, E. E.↗

A large imaging array CCD program

Test results on charge coupled device (CCD) imaging arrays (100 x 160 pixel and 400 x 400 pixel) employed as imaging detectors are reported, along with expected low light level (LLL) performance. Reasons for selection of a thinned backside-illuminated buried-channel three-phase CCD variant are indicated. The LLL performance and long storage time capability of the CCD imaging array recommend it for stellar photometry, detection and tracking of faint objects, and other astronomical applications.

Vescelus, F. E.↗

Measuring Tracking Accuracy of CCD Imagers

Tracking accuracy and resolution of charge-coupled device (CCD) imaging arrays measured by instrument originally developed for measuring performance of star-tracking telescope. Operates by projecting one or more artifical star images on surface of CCD array, moving stars in controlled patterns, and comparing star locations computed from CCD outputs with those calculated from step coordinates of micropositioner.

Stanton, R. H.↗

Discovery of Charge Order and Corresponding Edge State in Kagome Magnet FeGe

Kagome materials often host exotic quantum phases, including spin liquids, Chern gap, charge density wave, and superconductivity. Existing scanning microscopy studies of the kagome charge order have been limited to nonkagome surface layers. Here, we tunnel into the kagome lattice of FeGe to uncover features of the charge order. Our spectroscopic imaging identifies a 2×2 charge order in the magnetic kagome lattice, resembling that discovered in kagome superconductors. Spin mapping across steps of unit cell height demonstrates the existence of spin-polarized electrons with an antiferromagnetic stacking order. We further uncover the correlation between antiferromagnetism and charge order anisotropy, highlighting the unusual magnetic coupling of the charge order. Finally, we detect a pronounced edge state within the charge order energy gap, which is robust against the irregular shape fluctuations of the kagome lattice edges. Here, we discuss our results with the theoretically considered topological features of the kagome charge order including unconventional magnetism and bulk-boundary correspondence.

36 MATERIALS SCIENCE↗

Sonoluminescence Bubble Measurements using Vision-Based Algorithms

Vision-based measurement methods were used to measure bubble sizes in this sonoluminescence experiment. Bubble imaging was accomplished by placing the bubble between a bright light source and a microscope-CCD camera system. A collimated light-emitting diode was operated in a pulsed model with an adjustable time delay with respect to the piezo-electric transducer drive signal. The light-emitting diode produced a bubble shadowgraph consisting of a multiple exposure made by numerous light pulses imaged onto a charge-couple device camera. Each image was transferred from the camera to a computer-controlled machine vision system via a frame grabber. The frame grabber was equipped with on-board memory to accomodate sequential image buffering while images were transferred to the host processor and analyzed. This configuration allowed the host computer to perform diameter measurements, centroid position measurements and shape estimation in "real-time" as the next image was being acquired. Bubble size measurement accuracy with an uncertainty of 3 microns was achieved using standard lenses and machine vision algorithms. Bubble centroid position accuracy was also within the 3 micron tolerance of the vision system. This uncertainty estimation accounted for the optical spatial resolution, digitization errors and the edge detection algorithm accuracy. The vision algorithms include camera calibration, thresholding, edge detection, edge position determination, distance between two edges computations and centroid position computations.

Hall, Nancy R.↗

Maturing Electron Multiplying Charge Coupled Device Photon-Counting with Variable Multiplication Gain Imaging for a Coronagraphic Instrument

This is an introduction to a US Government Program that conducted high-contrast imaging experiments with an Electron Multiplying Charge Coupled Device (EMCCD) in an interferometric coronagraph. This report will introduce the concepts of “Charge Blooming” and “Starlight Saturation” in the context of high-contrast astronomical imaging. These phenomena adversely affect the performance of high-contrast photon-counting instruments that do not use a mask to physically block starlight in the science channel of the coronagraph. The problems will be presented with the help of images taken with a commercial EMCCD camera in the Visible Nulling Coronagraph at the Goddard Space Flight Center (GSFC). A new clocking scheme for EMCCDs – Variable Multiplication Gain Clocking – will be proposed as a means for suppressing horizontal blooming and starlight saturation in an astronomical camera. This opening report from the program will conclude with an introduction to a new controller for high-contrast imaging with EMCCDs in coronagraphs. This controller is being designed to allow a single frame from an EMCCD to be scanned in multiple modes – photon counting and digitization – to enable direct imaging of an exo-planet and wavefront control of a coronagraph, simultaneously.

Udayan Mallik↗

Space-Charge Aberrations in Single-Shot Time-Resolved Transmission Electron Microscopy

In this paper, we discuss effects of space-charge fields on imaging performance in a single-shot time-resolved transmission electron microscope. Using a Green’s function perturbation method, we derive analytical estimates for the effects of space-charge nonlinearity on the image formation process and the associated aberration coefficients. The dependence of these coefficients on the initial beam phase space distribution is elucidated. The results are validated by particle tracking simulations and provide fundamental scaling laws for the trade-off between temporal and spatial resolutions in single-shot time-resolved transmission electron microscopy.

43 PARTICLE ACCELERATORS↗

Measuring Pixel-Position Errors On CCD Imagers

Deviations of positions of pixels on charge-coupled-device (CCD) image detector from nominal rectangular grid pattern measured by method in which coherent-light interference fringes used as reference pattern. Conceived for use in determining pixel-position errors in astrometric cameras flown aboard spacecraft. Also applied to determination of similar errors in (and calibration of) terrestrial CCD cameras used as position sensors; for example, position-measuring cameras that are parts of robotic systems.

Shaklan, Stuart B.↗

Experience with 800 x 800 virtual phase and 500 x 500 three-phase CCD imagers

A description of the Galileo/Institute for Astronomy charge-coupled device (CCD) imaging system and its initial operation has been presented previously. Originally designed to operate a 500 x 500 backside illuminated three-phase CCD, the system has been modified to allow use of either the 500 x 500 sensor or the TI 800 x 800 virtual phase CCD. The modifications for the operation of the virtual phase CCD and current system performance with each type of sensor are discussed. A description is given of the implementation of various techniques discovered at the Jet Propulsion Laboratory that improve imager performance. These techniques include tri-level clocking of the virtual phase CCD to eliminate spurious charge generation in the serial register, the use of ultraviolet light flood with the backside thinned 500 x 500 three-phase device to dramatically improve the quantum efficiency in the blue, and the practical elimination of deferred charge in the three-phase device. Results of astronomical observations with each sensor are presented.

Hlivak, R. J.↗

Measurement of Photons Emitted by High-Energy Charged Particles as Background in Single-Photon Resolving Image Sensors

This work introduces an advanced technique optimized for detecting photons generated by charged particles, leveraging Skipper charge coupled device (Skipper-CCD) image sensors. By analyzing background sources and detection efficiencies, the technique achieves strong agreement between experimental results and Cherenkov-based simulations. It also provides a robust framework for investigating secondary photon production in environments with high fluxes of ionizing particles, such as those anticipated in space-based astronomical instruments. These secondary photons present a critical challenge as background noise for next-generation single-photon resolving imagers used to study faint celestial objects. Furthermore, the method exhibits significant potential for broader applications, including exploring photon generation in various substrate materials and examining their transport through multiple interfaces.

Fernandez Moroni, Guillermo [Fermilab; Chicago U.,↗

Imaging performance of a CCD area array at 200 K

The performance of a 100 x 100 charge coupled device imager was evaluated in the vicinity of 200 K. A set of operating conditions was determined which permits satisfactory operation of the imager from 300 K to 150 K while assuring maximum tolerance to ionizing radiation. Good imaging has been obtained for integration times in excess of 10 seconds at 200 K. Preliminary results on image storage indicate that storage times of many seconds are possible at 200 K.

Baker, W. D.↗

Aligning Astronomical Telescopes via Identification of Stars

A proposed method of automated, precise alignment of a ground-based astronomical telescope would eliminate the need for initial manual alignment. The method, based on automated identification of known stars and other celestial objects in the telescope field of view, would also eliminate the need for an initial estimate of the aiming direction. The method does not require any equipment other than a digital imaging device such as a charge-coupled-device digital imaging camera and control computers of the telescope and camera, all of which are standard components in professional astronomical telescope systems and in high-end amateur astronomical telescope systems. The method could be implemented in software running in the telescope or camera control computer or in an external computer communicating with the telescope pointing mount and camera control computers.

Whorton, Mark↗

Dynamic Deformation Measurements of an Aeroelastic Semispan Model

The techniques used to acquire, reduce, and analyze dynamic deformation measurements of an aeroelastic semispan wind tunnel model are presented. Single-camera, single-view video photogrammetry (also referred to as videogrammetric model deformation, or VMD) was used to determine dynamic aeroelastic deformation of the semispan 'Models for Aeroelastic Validation Research Involving Computation' (MAVRIC) model in the Transonic Dynamics Tunnel at the NASA Langley Research Center. Dynamic deformation was determined from optical retroreflective tape targets at five semispan locations located on the wing from the root to the tip. Digitized video images from a charge coupled device (CCD) camera were recorded and processed to automatically determine target image plane locations that were then corrected for sensor, lens, and frame grabber spatial errors. Videogrammetric dynamic data were acquired at a 60-Hz rate for time records of up to 6 seconds during portions of this flutter/Limit Cycle Oscillation (LCO) test at Mach numbers from 0.3 to 0.96. Spectral analysis of the deformation data is used to identify dominant frequencies in the wing motion. The dynamic data will be used to separate aerodynamic and structural effects and to provide time history deflection data for Computational Aeroelasticity code evaluation and validation.

Graves, Sharon S.↗