Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image alignment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Alignment, orientation, and Coulomb explosion of difluoroiodobenzene studied with the pixel imaging mass spectrometry (PImMS) camera

Laser-induced adiabatic alignment and mixed-field orientation of 2,6-difluoroiodobenzene (C 6 H 3 F 2 I) molecules are probed by Coulomb explosion imaging following either near-infrared strong-field ionization or extreme-ultraviolet multi-photon inner-shell ionization using free-electron laser pulses. The resulting photoelectrons and fragment ions are captured by a double-sided velocity map imaging spectrometer and projected onto two position-sensitive detectors. The ion side of the spectrometer is equipped with a pixel imaging mass spectrometry camera, a time-stamping pixelated detector that can record the hit positions and arrival times of up to four ions per pixel per acquisition cycle. Thus, the time-of-flight trace and ion momentum distributions for all fragments can be recorded simultaneously. Finally, we show that we can obtain a high degree of one-and three-dimensional alignment and mixed-field orientation and compare the Coulomb explosion process induced at both wavelengths

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Synthetic Aperture Radar Image Geolocation Using Fiducial Images

Synthetic Aperture Radar (SAR) creates imagery of the earth’s surface from airborne or spaceborne radar platforms. However, the nature of any radar is to geolocate its echo data, i.e., SAR images, relative to its own measured radar location. Acceptable accuracy and precision of such geolocation can be quite difficult to achieve, and is limited by any number of parameters. However, databases of geolocated earth imagery do exist, often using other imaging modalities, with Google Earth being one such example. These can often be much more accurate than what might be achievable by the radar itself. Consequently, SAR images may be aligned to some higher accuracy database, thereby improving the geolocation of features in the SAR image. Examples offer anecdotal evidence of the viability of such an approach.

47 OTHER INSTRUMENTATION↗

Assessment of contrast enhanced respiration managed cone-beam CT for image guided radiotherapy of intrahepatic tumors

Purpose: Contrast enhancement and respiration management are widely used during image acquisition for radiotherapy treatment planning of liver tumors along with respiration management at the treatment unit. However, neither respiration management nor intravenous contrast is commonly used during cone-beam CT (CBCT) image acquisition for alignment prior to radiotherapy. In this study, the authors investigate the potential gains of injecting an iodinated contrast agent in combination with respiration management during CBCT acquisition for liver tumor radiotherapy. Methods: Five rabbits with implanted liver tumors were subjected to CBCT with and without motion management and contrast injection. The acquired CBCT images were registered to the planning CT to determine alignment accuracy and dosimetric impact. The authors developed a simulation tool for simulating contrast-enhanced CBCT images from dynamic contrast enhanced CT imaging (DCE-CT) to determine optimal contrast injection protocols. The tool was validated against contrast-enhanced CBCT of the rabbit subjects and was used for five human patients diagnosed with hepatocellular carcinoma. Results: In the rabbit experiment, when neither motion management nor contrast was used, tumor centroid misalignment between planning image and CBCT was 9.2 mm. This was reduced to 2.8 mm when both techniques were employed. Tumors were not visualized in clinical CBCT images of human subjects. Simulated contrast-enhanced CBCT was found to improve tumor contrast in all subjects. Different patients were found to require different contrast injections to maximize tumor contrast. Conclusions: Based on the authors’ animal study, respiration managed contrast enhanced CBCT improves IGRT significantly. Contrast enhanced CBCT benefits from patient specific tracer kinetics determined from DCE-CT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Design and alignment of an all-spherical unobscured four-mirror image relay for an ultra-broadband sub-petawatt laser

We describe the design and alignment of an unobscured reflective image relay for use in an ultra-broadband half-petawatt laser system in development at the University of Rochester’s Laboratory for Laser Energetics. The design consists of four spherical mirrors in an unobscured configuration. We show the theoretical basis for such a four-mirror design using first-order optical matrix methods and nodal aberration theory. We also describe the process of aligning this design in a test bed and show the results of this alignment method. We were able to achieve a diffraction-limited nominal design. Furthermore, upon aligning the design in our test bed, we were able to successfully align the design to achieve our target wavefront error of less than 0.3 waves p–v and 0.07 waves rms at the central laser-operating wavelength of 910 nm.

47 OTHER INSTRUMENTATION↗

Fielding of a time-resolved tomographic diagnostic

A diagnostic instrument has been developed for the acquisition of high-speed time-resolved images at the Dual-Axis Radiographic Hydrodynamic Test (DARHT) Facility at Los Alamos National Laboratory. The instrument was developed in order to create time histories of the electron beam. Four discrete optical subsystems view Cerenkov light generated at an X-ray target inside of a vacuum envelope. Each system employs cylindrical optics to image light in one direction and collapse light in the orthogonal direction. Each of the four systems images and collapses in unique axes, thereby capturing unique information. Light along the imaging axis is relayed via optical fiber to streak cameras. A computer is used to reconstruct the original image from the four optically collapsed images. Due to DARHT’s adverse environment, the instrument can be operated remotely to adjust optical parameters and contains a subsystem for remote calibration. The instrument was deployed and calibrated, and has been used to capture and reconstruct images. Matters of alignment, calibration, control, resolution, adverse conditions and maintenance will be discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

PROPERTIES OF A SOLAR FLARE KERNEL OBSERVED BY HINODE AND SDO

Flare kernels are compact features located in the solar chromosphere that are the sites of rapid heating and plasma upflow during the rise phase of flares. An example is presented from a M1.1 class flare in active region AR 11158 observed on 2011 February 16 07:44 UT for which the location of the upflow region seen by EUV Imaging Spectrometer (EIS) can be precisely aligned to high spatial resolution images obtained by the Atmospheric Imaging Assembly (AIA) and Helioseismic and Magnetic Imager (HMI) on board the Solar Dynamics Observatory (SDO). A string of bright flare kernels is found to be aligned with a ridge of strong magnetic field, and one kernel site is highlighted for which an upflow speed of Almost-Equal-To 400 km s{sup -1} is measured in lines formed at 10-30 MK. The line-of-sight magnetic field strength at this location is Almost-Equal-To 1000 G. Emission over a continuous range of temperatures down to the chromosphere is found, and the kernels have a similar morphology at all temperatures and are spatially coincident with sizes at the resolution limit of the AIA instrument ({approx}<400 km). For temperatures of 0.3-3.0 MK the EIS emission lines show multiple velocity components, with the dominant component becoming more blueshifted with temperature from a redshift of 35 km s{sup -1} at 0.3 MK to a blueshift of 60 km s{sup -1} at 3.0 MK. Emission lines from 1.5-3.0 MK show a weak redshifted component at around 60-70 km s{sup -1} implying multi-directional flows at the kernel site. Significant non-thermal broadening corresponding to velocities of Almost-Equal-To 120 km s{sup -1} is found at 10-30 MK, and the electron density in the kernel, measured at 2 MK, is 3.4 Multiplication-Sign 10{sup 10} cm{sup -3}. Finally, the Fe XXIV {lambda}192.03/{lambda}255.11 ratio suggests that the EIS calibration has changed since launch, with the long wavelength channel less sensitive than the short wavelength channel by around a factor two.

79 ASTRONOMY AND ASTROPHYSICS↗

Extracting flat-field images from scene-based image sequences using phase correlation

Flat-field image processing is an essential step in producing high-quality and radiometrically calibrated images. Flat-fielding corrects for variations in the gain of focal plane array electronics and unequal illumination from the system optics. Typically, a flat-field image is captured by imaging a radiometrically uniform surface. The flat-field image is normalized and removed from the images. There are circumstances, such as with remote sensing, where a flat-field image cannot be acquired in this manner. For these cases, we developed a phase-correlation method that allows the extraction of an effective flat-field image from a sequence of scene-based displaced images. The method uses sub-pixel phase correlation image registration to align the sequence to estimate the static scene. The scene is removed from sequence producing a sequence of misaligned flat-field images. An average flat-field image is derived from the realigned flat-field sequence.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compact Kirkpatrick–Baez microscope mirrors for imaging laser-plasma x-ray emission

Compact Kirkpatrick–Baez microscope mirror components for use in imaging laser-plasma x-ray emission have been manufactured, coated, and tested. A single mirror pair has dimensions of 14 × 7 × 9 mm and a best resolution of ~5 μm. The mirrors are coated with Ir providing a useful energy range of 2-8 keV when operated at a grazing angle of 0.7°. The mirrors can be circularly arranged to provide 16 images of the target emission a configuration best suited for use in combination with a custom framing camera. As a result, an alternative arrangement of the mirrors would allow alignment of the images with a fourstrip framing camera.

47 OTHER INSTRUMENTATION↗

Robust methods for automatic image-to-world registration in cone-beam CT interventional guidance

Purpose: Real-time surgical navigation relies on accurate image-to-world registration to align the coordinate systems of the image and patient. Conventional manual registration can present a workflow bottleneck and is prone to manual error and intraoperator variability. This work reports alternative means of automatic image-to-world registration, each method involving an automatic registration marker (ARM) used in conjunction with C-arm cone-beam CT (CBCT). The first involves a Known-Model registration method in which the ARM is a predefined tool, and the second is a Free-Form method in which the ARM is freely configurable. Methods: Studies were performed using a prototype C-arm for CBCT and a surgical tracking system. A simple ARM was designed with markers comprising a tungsten sphere within infrared reflectors to permit detection of markers in both x-ray projections and by an infrared tracker. The Known-Model method exercised a predefined specification of the ARM in combination with 3D-2D registration to estimate the transformation that yields the optimal match between forward projection of the ARM and the measured projection images. The Free-Form method localizes markers individually in projection data by a robust Hough transform approach extended from previous work, backprojected to 3D image coordinates based on C-arm geometric calibration. Image-domain point sets were transformed to world coordinates by rigid-body point-based registration. The robustness and registration accuracy of each method was tested in comparison to manual registration across a range of body sites (head, thorax, and abdomen) of interest in CBCT-guided surgery, including cases with interventional tools in the radiographic scene. Results: The automatic methods exhibited similar target registration error (TRE) and were comparable or superior to manual registration for placement of the ARM within {approx}200 mm of C-arm isocenter. Marker localization in projection data was robust across all anatomical sites, including challenging scenarios involving the presence of interventional tools. The reprojection error of marker localization was independent of the distance of the ARM from isocenter, and the overall TRE was dominated by the configuration of individual fiducials and distance from the target as predicted by theory. The median TRE increased with greater ARM-to-isocenter distance (e.g., for the Free-Form method, TRE increasing from 0.78 mm to 2.04 mm at distances of {approx}75 mm and 370 mm, respectively). The median TRE within {approx}200 mm distance was consistently lower than that of the manual method (TRE = 0.82 mm). Registration performance was independent of anatomical site (head, thorax, and abdomen). The Free-Form method demonstrated a statistically significant improvement (p= 0.0044) in reproducibility compared to manual registration (0.22 mm versus 0.30 mm, respectively). Conclusions: Automatic image-to-world registration methods demonstrate the potential for improved accuracy, reproducibility, and workflow in CBCT-guided procedures. A Free-Form method was shown to exhibit robustness against anatomical site, with comparable or improved TRE compared to manual registration. It was also comparable or superior in performance to a Known-Model method in which the ARM configuration is specified as a predefined tool, thereby allowing configuration of fiducials on the fly or attachment to the patient.

60 APPLIED LIFE SCIENCES↗

Co-Registration of MEG and ULF MRI using a 7 channel low-Tc SQUID system

In human brain imaging, e.g. pre-surgical mapping, it is highly desired to obtain images with high spatial and temporal resolution. However, no single imaging device is capable of producing both a high spatial resolution anatomical image and a high temporal resolution functional image. During the last couple of years significant efforts have been directed towards magnetic resonance imaging (MRI) in fields comparable to the Earth's field, i.e. microtesla fields, or lower fields. The fields in this range are called ultra-low fields (ULF). Interestingly, the idea of magnetic resonance at microtesla fields is more than 50 years old. In ULF MR it is essential to use pre-polarization to increase the signal-to-noise ratio of the signal from the precessing spins, since the magnetization from the measurement field alone is very small. Even with the present level of prepolarization the ULF images are not as highly resolved as their high-field counterparts. By using a 7 channel system equipped with low transition temperature (T{sub c}) Superconducting QUantum Interference Devices (SQUIDs) to perform both ULF MRI and magnetoencephalography (MEG), it is possible to coregister a lower resolution ULF MR image and an MEG image obtained during one run. Thereby, the MEG data is aligned to the ULF MR image after performing a calibration run with a phantom. The ULF MR image can then be used to align the MEG data onto a high-field MR image. Recently, our group presented the first brain images obtained by ULF MRI. The MR imaging was combined with an MEG session performed a posteriori. The subject's head was moved in between the MRI run and the MEG run and no reference coils were used to quantify the translation. The main reason for the translation of the head was to improve the coverage of the auditory evoked response. In this paper, we report interleaved ULF MRI and MEG measurements co-registered in the same system.

42 ENGINEERING↗

TU-FG-201-04: Computer Vision in Autonomous Quality Assurance of Linear Accelerators

Purpose: Routine quality assurance (QA) of linear accelerators represents a critical and costly element of a radiation oncology center. Recently, a system was developed to autonomously perform routine quality assurance on linear accelerators. The purpose of this work is to extend this system and contribute computer vision techniques for obtaining quantitative measurements for a monthly multi-leaf collimator (MLC) QA test specified by TG-142, namely leaf position accuracy, and demonstrate extensibility for additional routines. Methods: Grayscale images of a picket fence delivery on a radioluminescent phosphor coated phantom are captured using a CMOS camera. Collected images are processed to correct for camera distortions, rotation and alignment, reduce noise, and enhance contrast. The location of each MLC leaf is determined through logistic fitting and a priori modeling based on knowledge of the delivered beams. Using the data collected and the criteria from TG-142, a decision is made on whether or not the leaf position accuracy of the MLC passes or fails. Results: The locations of all MLC leaf edges are found for three different picket fence images in a picket fence routine to 0.1mm/1pixel precision. The program to correct for image alignment and determination of leaf positions requires a runtime of 21– 25 seconds for a single picket, and 44 – 46 seconds for a group of three pickets on a standard workstation CPU, 2.2 GHz Intel Core i7. Conclusion: MLC leaf edges were successfully found using techniques in computer vision. With the addition of computer vision techniques to the previously described autonomous QA system, the system is able to quickly perform complete QA routines with minimal human contribution.

60 APPLIED LIFE SCIENCES↗

Fabrication of nanoscale patterns in lithium fluoride crystal using a 13.5 nm Schwarzschild objective and a laser produced plasma source

Lithium fluoride (LiF) crystal is a radiation sensitive material widely used as EUV and soft x-ray detector. The LiF-based detector has high resolution, in principle limited by the point defect size, large field of view, and wide dynamic range. Using LiF crystal as an imaging detector, a resolution of 900 nm was achieved by a projection imaging of test meshes with a Schwarzschild objective operating at 13.5 nm. In addition, by imaging of a pinhole illuminated by the plasma, an EUV spot of 1.5 {mu}m diameter in the image plane of the objective was generated, which accomplished direct writing of color centers with resolution of 800 nm. In order to avoid sample damage and contamination due to the influence of huge debris flux produced by the plasma source, a spherical normal-incidence condenser was used to collect EUV radiation. Together with a description of experimental results, the development of the Schwarzschild objective, the influence of condenser on energy density and the alignment of the imaging system are also reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Alignment and position visualization methods for the biomedical imaging and therapy (BMIT) MRT lift

The Microbeam Radiation Therapy (MRT) Lift is an eight stage positioning and scanning system at the Canadian Light Source’s BMIT Facility. Alignment of the sample with the beam using the MRT Lift is a time consuming and challenging task. The BMIT Group has developed a Python-based MRT Lift positioning and control program that uses a combination of computational and iterative methods to independently adjust the sample’s X, Y, Z, pitch and roll positions. The program offers “1-Click” alignment of the sample to the beam. Use of a wireframe visualization technique enables even minute movements to be illustrated. Proposed movements and the resulting MRT Lift position can be manually verified before being applied. Optional integration with the SolidWorks modelling platform allows high quality renderings of the MRT Lift in its current or proposed position to be displayed in real time. Human factors principles are incorporated into the program with the objective of delivering easy to use controls for this complex device.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An Experimental Feasibility Study on Applying Neutron Tomography to Encapsulated Spent Nuclear Fuel - 20050

Visual inspection makes easier to ensure the integrity and safety of spent nuclear fuel (SNF) than any classical techniques. Various classical techniques have been applied but there are no reliable methods to qualitatively and quantitatively verify spent fuel in dry storage. Thus, the present authors have developed the prototype safeguards apparatus for dry storage employing the array of He-4 gas scintillation detectors (S670E, Arktis Radiation Detectors Ltd., Switzerland), newly designed to simultaneously measure thermal and fast neutrons without any moderators. The S670E detector has a cylindrical shape with a diameter of 52 mm and active length of 600 mm (total length: 875 mm). The detector is filled by He-4 gas with an approximate pressure of 180 bar for fast neutron detection, and its inner wall is coated by Li-6 for thermal neutron detection. The scintillation lights generated via Li-6 nuclear reaction and elastic scattering are collected by 24 SiPMs linearly paired at the center of the detector. The detector delivers a TTL (Transistor-Transistor Logic) output for pulse readout and UART (Universal Asynchronous Receiver Transmitter) for device control. In order to assess feasibility of the apparatus, an experimental system has been designed, built, and optimized via computational studies. Cf-252 neutron sources and linearly arrayed detectors, working as a single detector, were occupied for this study due to the difficulties in working with SNF. The laboratory scale cask (diameter: 0.67 m, height: 1.5 m), minimized by a factor of 10 compared to the actual thickness of a commercial TN-32 cask, was also manufactured. The detector array was designed to rotate the lab-scale cask and obtain 36 image profiles at every 10 degrees. All profiles were aligned in single frame image called a sinogram, and the cross-sectional image was then fabricated by the inverse radon transform algorithm. These experiments have been repeated with different configurations and numbers of sources. Some gamma-ray sources were also measured with neutron sources in order to distinguish between neutron and gamma-ray pulses. Basically, a He-4 detector is designed to run on Linux OS so it is difficult to directly apply to Windows-based equipment widely used in S. Korea. Therefore, a new data acquisition board working on Windows OS was designed and built. The board mainly consists of FPGA (Field Programmable Gate Array) and SoC (System on Chip) for TTL pulse readout, sorting measured data, and transferring data to a user interface. In conclusion, the tomographic system at lab-scale has shown considerable potential to detect a partial or gross defect of encapsulated assemblies in dry storage. Next steps of this study will be to 1) repeatedly carry out experiments to demonstrate scientific reliability and validity, and 2) numerically integrate signals with weight factors to enhance the image quality since the suggested system based on passive interrogation method requires longer measurement time. Finally, the system will apply to a commercial dry storage phased out soon in S. Korea. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

HINODE/EIS SPECTROSCOPIC VALIDATION OF VERY HOT PLASMA IMAGED WITH THE SOLAR DYNAMICS OBSERVATORY IN NON-FLARING ACTIVE REGION CORES

We use coronal imaging observations with the Solar Dynamics Observatory/Atmospheric Imaging Assembly (AIA), and Hinode/Extreme-ultraviolet Imaging Spectrometer (EIS) spectral data to explore the potential of narrowband EUV imaging data for diagnosing the presence of hot (T {approx}> 5 MK) coronal plasma in active regions. We analyze observations of two active regions (AR 11281, AR 11289) with simultaneous AIA imaging and EIS spectral data, including the Ca XVII line (at 192.8 A), which is one of the few lines in the EIS spectral bands sensitive to hot coronal plasma even outside flares. After careful co-alignment of the imaging and spectral data, we compare the morphology in a three-color image combining the 171, 335, and 94 A AIA spectral bands, with the image obtained for Ca XVII emission from the analysis of EIS spectra. We find that in the selected active regions the Ca XVII emission is strong only in very limited areas, showing striking similarities with the features bright in the 94 A (and 335 A) AIA channels and weak in the 171 A band. We conclude that AIA imaging observations of the solar corona can be used to track hot plasma (6-8 MK), and so to study its spatial variability and temporal evolution at high spatial and temporal resolution.

79 ASTRONOMY AND ASTROPHYSICS↗

Fielding of a Time-Resolved Tomographic Diagnostic

A diagnostic instrument has been developed for the acquisition of high-speed time-resolved images at the Dual-Axis Radiographic Hydrodynamic Test (DARHT) Facility at Los Alamos National Laboratory. The instrument was developed in order to create time histories of the electron beam. Four discrete optical subsystems view Cerenkov light generated at an x-ray target inside of a vacuum envelope. Each system employs cylindrical optics to image light in one direction and collapse light in the orthogonal direction. Each of the four systems images and collapses in unique axes, thereby capturing unique information. Light along the imaging axis is relayed via optical fiber to streak cameras. A computer is used to reconstruct the original image from the four optically collapsed images. Due to DARHT’s adverse environment, the instrument can be operated remotely to adjust optical parameters and contains a subsystem for remote calibration. The instrument was deployed and calibrated, and has been used to capture and reconstruct images. Matters of alignment, calibration, control, resolution, and adverse conditions will be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Imaging arrangement and microscope

An embodiment of the present invention is an imaging arrangement that includes imaging optics, a fiducial light source, and a control system. In operation, the imaging optics separate light into first and second tight by wavelength and project the first and second light onto first and second areas within first and second detector regions, respectively. The imaging optics separate fiducial light from the fiducial light source into first and second fiducial light and project the first and second fiducial light onto third and fourth areas within the first and second detector regions, respectively. The control system adjusts alignment of the imaging optics so that the first and second fiducial light projected onto the first and second detector regions maintain relatively constant positions within the first and second detector regions, respectively. Another embodiment of the present invention is a microscope that includes the imaging arrangement.

42 ENGINEERING↗

Non parametric denoising methods based on wavelets: Application to electron microscopy images in low exposure time

The 3D reconstruction of the Cryo-Transmission Electron Microscopy (Cryo-TEM) and Energy Filtering TEM images (EFTEM) hampered by the noisy nature of these images, so that their alignment becomes so difficult. This noise refers to the collision between the frozen hydrated biological samples and the electrons beam, where the specimen is exposed to the radiation with a high exposure time. This sensitivity to the electrons beam led specialists to obtain the specimen projection images at very low exposure time, which resulting the emergence of a new problem, an extremely low signal-to-noise ratio (SNR). This paper investigates the problem of TEM images denoising when they are acquired at very low exposure time. So, our main objective is to enhance the quality of TEM images to improve the alignment process which will in turn improve the three dimensional tomography reconstructions. We have done multiple tests on special TEM images acquired at different exposure time 0.5s, 0.2s, 0.1s and 1s (i.e. with different values of SNR)) and equipped by Golding beads for helping us in the assessment step. We herein, propose a structure to combine multiple noisy copies of the TEM images. The structure is based on four different denoising methods, to combine the multiple noisy TEM images copies. Namely, the four different methods are Soft, the Hard as Wavelet-Thresholding methods, Bilateral Filter as a non-linear technique able to maintain the edges neatly, and the Bayesian approach in the wavelet domain, in which context modeling is used to estimate the parameter for each coefficient. To ensure getting a high signal-to-noise ratio, we have guaranteed that we are using the appropriate wavelet family at the appropriate level. So we have chosen âĂIJsym8âĂİ wavelet at level 3 as the most appropriate parameter. Whereas, for the bilateral filtering many tests are done in order to determine the proper filter parameters represented by the size of the filter, the range parameter and the spatial parameter respectively. The experiments reported in this paper demonstrate the performance of the Bilateral Filtering and the Bayesian approaches in terms of improving the SNRout and the image quality. Taken together, these results suggest that the Bayesian process has a potential to outperform all the used methods, where in the multiple noisy copies structure it gave us the best SNRout without change of the golden beads diameter. The Bayesian approach yielded enhanced average image without needing a huge amount of copies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗