Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “hyperpolarization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

162 records · Page 9

Emphysema Quantification in Inflation-Fixed Lungs Using Low-Dose Computed Tomography and 3He Magnetic Resonance Imaging

Abstract: Objective: To evaluate the use of inflation-fixed lung tissue for emphysema quantification with CT and 3He MR diffusion imaging. Methods: Fourteen subjects representing a range of chronic obstructive pulmonary disease severity who underwent complete or lobar lung resection were studied. CT measurements of lung attenuation and MR measurements of the hyperpolarized 3He apparent diffusion coefficient (ADC) in resected specimens fixed in inflation with heated formalin vapor were compared with measurements obtained before fixation. Results: The mean CT emphysema index was 56% ± 17% before and 58% ± 19% after fixation (P=0.77;R=0.76). Index differences correlated with differences in lung volume (R2=0.47). The mean 3He ADC was 0.40 ± 0.15 cm2/sec before and 0.39 ± 0.14 cm2/sec after fixation (P=0.03, R=0.98). The CT emphysema index and the 3He ADC were correlated before (R=0.89) and after fixation (R=0.79). Conclusion: Concordance of CT and 3He MR imaging measurements in unfixed and inflation-fixed lungs supports the use of inflation-fixed lungs for quantitative imaging studies in emphysema.

60 APPLIED LIFE SCIENCES↗

Characterization of a low-pressure high-capacity {sup 129}Xe flow-through polarizer

We describe a low-pressure flow-through apparatus for generating hyperpolarized {sup 129}Xe and report its performance by examining both the output {sup 129}Xe polarization P{sub Xe} by NMR and the in situ Rb polarization profile by optically detected electron paramagnetic resonance. The polarizer is based on a previously presented design employing a long optical pumping cell, lean Xe mixture at low pressure, Rb presaturation, and counterflow of gas with respect to the direction of light propagation. The numerical model to which we compare the polarizer's performance includes the temperature dependence of the Rb-{sup 129}Xe spin-exchange rate, which has not previously been treated. The qualitative trends in the data mostly follow those in the model, although the model predicts P{sub Xe} to be up to a factor of two higher than observed. This discrepancy cannot be attributed to low Rb polarization: the model and the optically detected electron paramagnetic resonance data (acquired at six points along the length of the heated portion of the optical pumping cell) are in reasonable agreement and show typical values of 85%-95%, although measurements also reveal an anomalous region of depressed Rb polarization near the middle of the cell. The highest output {sup 129}Xe polarization P{sub Xe}=84+-16%, was recorded using approx =60 W of frequency-narrowed laser light at a Xe partial pressure (referenced to 20 deg. C) of 1.1+-0.2 mbar, flowing at 1 sccm of Xe; typical values were P{sub Xe}approx =20% flowing at 10 sccm of Xe with approx =30 W of laser light.

74 ATOMIC AND MOLECULAR PHYSICS↗

Measurement of spin-exchange and relaxation parameters for polarizing {sup 21}Ne with K and Rb

Hyperpolarized K-{sup 3}He comagnetometers have been used for tests of fundamental physics and inertial rotation sensing. These experiments will demonstrate increased sensitivity if the {sup 3}He buffer gas is replaced with {sup 21}Ne. We measure the parameters necessary to realize implementation of an alkali-metal-{sup 21}Ne comagnetometer for two promising alkali-metal species, Rb and K. The spin-exchange rate constant for K with {sup 21}Ne and Rb with {sup 21}Ne are measured using two different methods. We also make the first measurement of the K-{sup 21}Ne contact spin interaction. Measurements for the Rb-{sup 21}Ne contact spin interaction, as well as the spin-destruction coefficients for {sup 21}Ne with both alkali-metal species are consistent with previous measurements. Additionally the quadrupolar spin-relaxation rate of {sup 21}Ne is measured. Finally, the feasibility of utilizing polarized {sup 21}Ne for operation in a comagnetometer is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Limits on magnetically induced Faraday rotation from polarized He 3 atoms

Faraday rotation has become a powerful tool in a large variety of physics applications. Most prominently, Faraday rotation can be used in precision magnetometry. Here we report measurements of gyromagnetic Faraday rotation on a dense, hyperpolarized 3 He gas target. Here, theoretical calculations predict the rotations of linearly polarized light due to the magnetization of spin-1/2 particles on the scale of 10 –7 radians. To maximize the signal, a 3 He target designed to use with a multipass cavity is combined with a sensitive apparatus for polarimetry that can detect optical rotations on the order of 10 –8 radians. Although the expected results are well above the sensitivity for the given experimental conditions, no nuclear-spin-induced rotation was observed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Capturing membrane structure and function in lattice Boltzmann models

Here, we develop a mesoscopic approach to model the nonequilibrium behavior of membranes at the cellular scale. Relying on lattice Boltzmann methods, we develop a solution procedure to recover the Nernst-Planck equations and Gauss's law. A general closure rule is developed to describe mass transport across the membrane, which is able to account for protein-mediated diffusion based on a coarse-grained representation. We demonstrate that our model is able to recover the Goldman equation from first principles and show that hyperpolarization occurs when membrane charging dynamics are controlled by multiple relaxation timescales. The approach provides a promising way to characterize non-equilibrium behaviors that arise due to the role of membranes in mediating transport based on realistic three-dimensional cell geometries.

59 BASIC BIOLOGICAL SCIENCES↗

Evaluation of Lattice Light Shift at Low 10 -19 Uncertainty for a Shallow Lattice Sr Optical Clock

A Wannier-Stark optical lattice clock has demonstrated unprecedented measurement precision for optical atomic clocks. Here, we present a systematic evaluation of the lattice light shift, a necessary next step for establishing this system as an accurate atomic clock. With precise control of the atomic motional states in the lattice, we report accurate measurements of the multipolar and the hyperpolar contributions and the operational lattice light shift with a fractional frequency uncertainty of 3.5×10 -19 .

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

MO-C-17A-08: Evaluation of Lung Deformation Using Three Dimensional Strain Maps

Purpose: To develop a systematic approach to generate three dimensional (3D) strain maps of lung using the displacement vector field (DVF) during the respiratory deformation, and to demonstrate its application in evaluating deformable image registration (DIR). Methods: A DVF based strain tensor at each voxel of interest (VOI) was calculated from the relative displacements between the VOI and each of the six nearest neighbors. The maximum and minimum stretches of a VOI can be determined by the principal strains (E{sub 1}, E{sub 2} and E{sub 3}), which are the eigenvalues and the corresponding strain tensors. Two healthy volunteers enrolled in this study under IRB-approved protocol, each was scanned using 3D Hyperpolarized He-3 tagging-MRI and 3D proton-MRI with TrueFISP sequence at the endof- inhalation (EOI) and the end-of-exhalation (EOE) phases. 3D DVFs of tagging- and proton-MRI were obtained by the direct measurements of the tagging grid trajectory and by the DIR method implemented in commercial software. Results: 3D strain maps were successfully generated for all DVFs. The principal strain E1s were calculated as 0.43±0.05 and 0.17±0.25 for tagging-MRI and proton-MRI, respectively. The large values of E{sub 1} indicate the predominant lung motion in the superior-inferior (SI) direction. Given that the DVFs from the tagging images are considered as the ground truth, the discrepancies in the DIR-based strain maps suggest the inaccuracy of the DIR algorithm. In the E{sub 1} maps of tagging-MRI for subject 1, the fissures were distinguishable by the larger values (0.49±0.02) from the adjacent tissues (0.41±0.03) due to the larger relative displacement between the lung lobes. Conclusion: We have successfully developed a methodology to generate DVF-based 3D strain maps of lung. It can potentially enable us to better understand the pulmonary biomechanics and to evaluate and improve the DIR algorithms for the lung deformation. We are currently studying more subjects to evaluate this tool.

60 APPLIED LIFE SCIENCES↗

WE-AB-BRA-11: Development of Physiological-Based Virtual Thorax Phantoms for Evaluation of Deformable Image Registration

Purpose: To develop a methodology of constructing physiological-based virtual thorax phantom based on hyperpolarized (HP) gas tagging MRI for evaluating deformable image registration (DIR). Methods: Three healthy subjects were imaged at both the end-of-inhalation (EOI) and the end-of-exhalation (EOE) phases using a high-resolution (2.5mm isovoxel) 3D proton MRI, as well as a hybrid MRI which combines HP gas tagging MRI and a low-resolution (4.5mm isovoxel) proton MRI. A sparse tagging displacement vector field (tDVF) was derived from the HP gas tagging MRI by tracking the displacement of tagging grids between EOI and EOE. Using the tDVF and the high-resolution MR images, we determined the motion model of the entire thorax in the following two steps: 1) the DVF inside of lungs was estimated based on the sparse tDVF using a novel multi-step natural neighbor interpolation method; 2) the DVF outside of lungs was estimated from the DIR between the EOI and EOE images (Velocity AI). The derived motion model was then applied to the high-resolution EOI image to create a deformed EOE image, forming the virtual phantom where the motion model provides the ground truth of deformation. Five DIR methods were evaluated using the developed virtual phantom. Errors in DVF magnitude (Em) and angle (Ea) were determined and compared for each DIR method. Results: Among the five DIR methods, free form deformation produced DVF results that are most closely resembling the ground truth (Em=1.04mm, Ea=6.63°). The two DIR methods based on B-spline produced comparable results (Em=2.04mm, Ea=13.66°; and Em =2.62mm, Ea=17.67°), and the two optical-flow methods produced least accurate results (Em=7.8mm; Ea=53.04°; Em=4.45mm, Ea=31.02°). Conclusion: A methodology for constructing physiological-based virtual thorax phantom based on HP gas tagging MRI has been developed. Initial evaluation demonstrated its potential as an effective tool for robust evaluation of DIR in the lung.

60 APPLIED LIFE SCIENCES↗

WE-FG-206-08: Pulmonary Functional Imaging Biomarkers of NSCLC to Guide and Optimize Functional Lung Avoidance Radiotherapy

Purpose: Functional lung avoidance radiotherapy promises optimized therapy planning by minimizing dose to well-functioning lung and maximizing dose to the rest of the lung. Patients with NSCLC commonly present with co-morbid COPD and heterogeneously distributed ventilation abnormalities stemming from emphysema, airways disease, and tumour burden. We hypothesized that pulmonary functional imaging methods may be used to optimize radiotherapy plans to avoid regions of well-functioning lung and significantly improve outcomes like quality-of-life and survival. To ascertain the utility of functional lung avoidance therapy in clinical practice, we measured COPD phenotypes in NSCLC patients enrolled in a randomized-controlled-clinical-trial prior to curative intent therapy. Methods: Thirty stage IIIA/IIIB NSCLC patients provided written informed consent to a randomized-controlled-clinical-trial ( http://clinicaltrials.gov/ct2/show/NCT02002052 ) comparing outcomes in patients randomized to standard or image-guided radiotherapy. Hyperpolarized noble gas MRI ventilation-defect-percent (VDP) (Kirby et al, Acad Radiol, 2012) as well as CT-emphysema measurements were determined. Patients were stratified based on quantitative imaging evidence of ventilation-defects and emphysema into two subgroups: 1) tumour-specific ventilation defects only (TSD), and, 2) tumour-specific and other ventilation defects with and without emphysema (TSD{sub VE}). Receiver-operating-characteristic (ROC) curves were used to characterize the performance of clinical measures as predictors of the presence of non-tumour specific ventilation defects. Results: Twenty-one out of thirty subjects (70%) had non-tumour specific ventilation defects (TSD{sub VE}) and nine subjects had ONLY tumour-specific defects (TSD). Subjects in the TSD{sub VE} group had significantly greater smoking-history (p=.006) and airflow obstruction (FEV{sub 1}/FVC) (p=.001). ROC analysis demonstrated an 87% classification rate for smoking pack-years, 90% for FEV{sub 1}/FVC, and 56% for tumour RECIST measurements for identifying patients with non-tumour and tumour-specific ventilation abnormalities. Conclusion: 70% of NSCLC patients had ventilation abnormalities stemming from emphysema, airways disease and tumour burden. Smoking-history and airflow obstruction, but not RECIST, identified NSCLC patients with ventilation abnormalities appropriate for functional lung avoidance therapy.

60 APPLIED LIFE SCIENCES↗

Numerical Simulation and Modeling of Hydrogen Gas Evolution on Planar and Microwire Array Electrodes

The impact of gas evolution on the electrochemical characteristics of planar electrodes and microwire array electrodes has been analyzed using modeling and simulation. The impacts can mainly be broken into three phenomena: a) a shift in the local reversible hydrogen electrode potential; b) hyperpolarization; and c) an increase in the solution resistance of the electrolyte. The local reversible hydrogen electrode potential shift was found to play the most important role, constituting >40% of the total potential drop between the cathode and reference electrode, following correction for cell resistance. Compared to planar electrodes, a microwire array structure reduces the impact of bubbles on the solution conductance, but the shift in the local reversible hydrogen electrode potential varies with distance from the actual electrode surface.

25 ENERGY STORAGE↗

Photochemically Triggered Para-Hydrogen-Induced Polarization in a Diplatinum Trihydride Complex

Transition metal complexes containing platinum(II) are of substantial interest for their rich photophysics, biomedical applications, and catalytic function. Nuclear magnetic resonance (NMR) spectra of the spin-1/2 isotope, 195Pt, offer detailed insights into the molecular structures of closed-shell Pt(II) complexes, including solvent effects. However, the sensitivity of 195Pt NMR is mediocre, and its NMR spectra are typically complex. As a result, 1H NMR spectra are used as the primary characterization tool for Pt(II)-based molecules, relying on J-coupling to the 195Pt nucleus to provide structural information from the resulting satellite peaks. In efforts to significantly improve the information content from 1H NMR spectroscopy in a Pt(II)-containing molecule, we utilize [Pt2H2(μ-H)(μ-dppm)2]PF6, where dppm is bis(diphenylphosphino)methane, and leverage its established photoactivity with UV light and H2 for para-hydrogen-induced polarization (PHIP) to enhance the resultant NMR signals, revealing numerous 195Pt J-couplings. Moreover, we investigate direct solvent hyperpolarization effects, as well as the indirect effects of solvent on the various observed J-coupling constants in the Pt species, demonstrating correlations with both Lewis basicity and dielectric constant.

Brown, Emily E. [Department of Chemistry; North Ca↗

CryoEM structures of the human CLC-2 voltage-gated chloride channel reveal a ball-and-chain gating mechanism

CLC-2 is a voltage-gated chloride channel that contributes to electrical excitability and ion homeostasis in many different tissues. Among the nine mammalian CLC homologs, CLC-2 is uniquely activated by hyperpolarization, rather than depolarization, of the plasma membrane. The molecular basis for the divergence in polarity of voltage gating among closely related homologs has been a long-standing mystery, in part because few CLC channel structures are available. Here, we report cryoEM structures of human CLC-2 at 2.46 – 2.76 Å, in the presence and absence of the selective inhibitor AK-42. AK-42 binds within the extracellular entryway of the Cl – -permeation pathway, occupying a pocket previously proposed through computational docking studies. In the apo structure, we observed two distinct conformations involving rotation of one of the cytoplasmic C-terminal domains (CTDs). In the absence of CTD rotation, an intracellular N-terminal 15-residue hairpin peptide nestles against the TM domain to physically occlude the Cl – -permeation pathway. This peptide is highly conserved among species variants of CLC-2 but is not present in other CLC homologs. Previous studies suggested that the N-terminal domain of CLC-2 influences channel properties via a “ball-and-chain” gating mechanism, but conflicting data cast doubt on such a mechanism, and thus the structure of the N-terminal domain and its interaction with the channel has been uncertain. Through electrophysiological studies of an N-terminal deletion mutant lacking the 15-residue hairpin peptide, we support a model in which the N-terminal hairpin of CLC-2 stabilizes a closed state of the channel by blocking the cytoplasmic Cl – -permeation pathway.

59 BASIC BIOLOGICAL SCIENCES↗

Structural Basis for the cAMP-dependent Gating in the Human HCN4 Channel

Hyperpolarization-activated cAMP-regulated (HCN) channels play important physiological roles in both cardiovascular and central nervous systems. Among the four HCN isoforms, HCN2 and HCN4 show high expression levels in the human heart, with HCN4 being the major cardiac isoform. The previously published crystal structure of the mouse HCN2 (mHCN2) C-terminal fragment, including the C-linker and the cyclic-nucleotide binding domain (CNBD), has provided many insights into cAMP-dependent gating in HCN channels. However, structures of other mammalian HCN channel isoforms have been lacking. Here we used a combination of approaches including structural biology, biochemistry, and electrophysiology to study cAMP-dependent gating in HCN4 channel. First we solved the crystal structure of the C-terminal fragment of human HCN4 (hHCN4) channel at 2.4 {angstrom}. Overall we observed a high similarity between mHCN2 and hHCN4 crystal structures. Functional comparison between two isoforms revealed that compared with mHCN2, the hHCN4 protein exhibited marked different contributions to channel function, such as a {approx}3-fold reduction in the response to cAMP. Guided by structural differences in the loop region between {beta}4 and {beta}5 strands, we identified residues that could partially account for the differences in response to cAMP between mHCN2 and hHCN4 proteins. Moreover, upon cAMP binding, the hHCN4 C-terminal protein exerts a much prolonged effect in channel deactivation that could have significant physiological contributions.

59 BASIC BIOLOGICAL SCIENCES↗

A Rabbit Irradiation Platform for Outcome Assessment of Lung Stereotactic Radiosurgery

Purpose: To evaluate a helical tomotherapy-based rodent radiosurgery platform that reproduces human image-guided radiosurgery treatment to study radiobiologic effects of stereotactic radiosurgery on lung tissues using functional magnetic resonance imaging (MRI). Methods and Materials: Hypofractionated radisourgery (20 Gy x 3) was delivered to the right lung of three New Zealand rabbits using Helical TomoTherapy with MVCT image guidance. Contrast-enhanced MR perfusion, hyperpolarized helium-3 MR ventilation, and CT were obtained before radiation and monthly for 4 months after radiation. All MRI was performed on a 1.5-T whole-body scanner with broad-band capabilities. Results: Precise dose delivery to 1.6 cc of the lower right lung was achieved without additional immobilization. No deficits were detected at baseline with respect to perfusion and ventilation. Lung perfusion deficits in the irradiated lung regions began at 2 months after radiation and worsened with time. No ventilation deficits were observed after radiation. Decrease in lung CT density in irradiated regions was observed after radiation, but the changes were less significant than those in perfusion MRI. Conclusions: We demonstrated that highly conformal radiation can be reproducibly delivered to a small volume of rodent lung on a widely available clinical unit. The radiation-induced lung injury can be detected as early as 2 months after radiation with perfusion MRI. The primary pattern of injury agrees with previously reported endothelial damage to radiosurgical radiation doses. This experimental design provides a cost-effective methodology for producing radiosurgical injuries in rodents that reproduces current human treatments for studying radiation injury and agents that might affect it.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Temperature response of 129Xe depolarization transfer and its application for ultra-sensitive NMR detection

Temporary trapping of atomic xenon in functionalized cryptophane cages makes the high sensitivity of hyperpolarized (hp) 129Xe available for highly specific NMR detection of biomolecules like proteins in solution. Here, we study the signal transfer onto a reservoir of unbound hp xenon by gating the residence time of the nuclei in the cage through the temperature-dependent exchange rate. Temperature changes were detectable immediately as an altered reservoir signal and yielded a sensitivity of 0.6 K. The temperature response is adjustable with lower concentrations of caged xenon providing more sensitivity at higher temperatures and allows ultra-sensitive detection of such molecular cages at 310 K. Functionalized cryptophane could be detected at concentrations as low as 10nM which corresponds to a 4000-fold sensitivity enhancement compared to conventional detection. This sensitivity makes hp-NMR capable of detecting such constructs in concentrations far belowthe detection limit by UV-visible light absorbance.

36 MATERIALS SCIENCE↗

Dynamic Nuclear Polarization Enhanced Nuclear Spin Optical Rotation

Here, nuclear spin optical rotation (NSOR) has been investigated as a magneto-optical effect, which holds the potential for applications, including hybrid optical-nuclear magnetic resonance (NMR) spectroscopy and gradientless imaging. The intrinsic nature of NSOR renders its detection relatively insensitive, which has prevented it moving from a proof of concept to a method supporting chemical characterizations. In this work, the dissolution dynamic nuclear polarization technique is introduced to provide nuclear spin polarization, increasing the signal-to-noise ratio by several thousand times. NSOR signals of 1 H and 19 F nuclei are observed in a single scan for diluted compounds, which has made this effect suitable for the determination of electronic transitions from a specific nucleus in a large molecule.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Dynamic nuclear polarization solid-state NMR in heterogeneous catalysis research

In this study, a revolution in solid-state nuclear magnetic resonance (SSNMR) spectroscopy is taking place, attributable to the rapid development of high-field dynamic nuclear polarization (DNP), a technique yielding sensitivity improvements of 2–3 orders of magnitude . This higher sensitivity in SSNMR has already impacted materials research, and the implications of new methods on catalytic sciences are expected to be profound.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗