Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “humidity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Mechanisms of degradation in adhesive joint strength: Glassy polymer thermoset bond in a humid environment

The degradation in the strength of napkin-ring (NR) joints bonded with an epoxy thermoset is evaluated in a humid environment. While adherend composition (stainless steel and aluminum) and surface preparation (polished, grit blasted, primed, coupling agent coated) do not affect virgin (time=0) joint strength, they can significantly affect the role of moisture on the strength of the joint. Adherend surface abrasion and corrosion processes are found to be key factors in determining the reliability of joint strength in humid environments. In cases where surface specific joint strength degradation processes are not active, decreases in joint strength can be accounted for by the glass transition temperature, T g , depression of the adhesive associated with water sorption. Under these conditions, joint strength can be rejuvenated to virgin strength by drying. In addition, the decrease in joint strength associated with water sorption can be predicted by the Simplified Potential Energy Clock (SPEC) model by shifting the adhesive reference temperature, T ref , by the same amount as the T g depression. When surface specific degradation mechanisms are active, they can reduce joint strength below that associated with adhesive T g depression, and joint strength is not recoverable by drying. Furthermore, a critical relative humidity (or, potentially, critical water sorption concentration), below which the surface specific degradation does not occur, appears to exist for the polished stainless steel joints.

36 MATERIALS SCIENCE↗

Humidity’s impact on greenhouse gas emissions from air conditioning

We report that the increasing need to cool the air in our built environment is both a cause and an effect of climate change. Air conditioning accounts for a large portion of global greenhouse gas emissions today, which we estimate at 3.9%; however, the role that humidity plays in these emissions is often overlooked. Here, we show that the emissions associated with reducing air humidity (i.e., removing water vapor from air) are larger than emissions associated with reducing air temperature (i.e., cooling air). We calculate these emissions for today and 2050 and show how dramatically humidity-related emissions will increase with rising cooling demand around the world. We also calculate the minimum separation energy for removing water vapor from air and find that this is at least an order of magnitude less than the processes used today.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improving the humidity sensing below 30% RH of TiO2 with GO modification

Highlights: • Rutile phase TiO{sub 2} aggregates were prepared via thermal oxidation of pure Ti-discs, which is simple and inexpensive method. • TiO{sub 2} aggregates with submicron particles based sensor exhibited ultra-high response (R{sub A}/R{sub H{sub 2O}} > 10{sup 6}) to 90% RH. • Sensors based on TiO{sub 2} modified with GO exhibited improved sensitivity, stability and reproducibility. - Abstract: The development of cost-effective, robust, and reliable humidity monitoring system is nowadays in high demand. To this context, humidity sensors based on rutile TiO{sub 2} aggregates were prepared via thermal oxidation of pure Ti-discs at 1000 °C. The sensors based on only TiO{sub 2} aggregates exhibited the ultra-high response of about six orders of magnitude (R{sub A}/R{sub %RH} ∼ 10{sup 6}) to 90% RH with a response time of 28 s and excellent stability. However, these sensors showed no response to RH below 30%, which limits their use in practical applications for such RH level monitoring. Although with a reduced response in high RH, the TiO{sub 2} modified with GO showed potential to overcome this drawback. To understand their functionality, the TiO{sub 2} aggregates and TiO{sub 2}/GO were further characterized by XRD, SEM, TEM, Raman and FT-IR spectroscopy. The presented results are of high interest in terms of wide range humidity monitoring, low-cost and simple synthesis route, and high stability.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effect of humidity of build chamber in hybrid manufacturing systems on part performance

Here hybrid manufacturing combines additive with subtractive machining operations which often require the use of a coolant, that can increase the humidity of the build chamber. The water vapor can be adsorbed on the powder surfaces and subsequently dissociate into hydrogen and oxygen during melting and can be absorbed by part during solidification. Here, we investigated the effect of build chamber humidity during hybrid manufacturing on the part quality on two most common classes of steels i.e., austenitic (316L) and ferritic (grade 91). We report that the humidity increase has a negligible effect on part performance of both classes of steels.

316L stainless steel↗

Mitigating humidity interference in chemiresistive hydrogen sensors through hydrophobic surface functionalization

Chemiresistive gas sensors based on semiconductor metal oxides, such as tin dioxide (SnO₂), are indispensable for detecting and monitoring toxic gases and pollutants, making them critical components in industrial and environmental applications. To enhance their performance, the metal oxides are loaded with noble metals such as palladium (Pd). However, ambient humidity poses a significant challenge to their performance. The presence of adsorbed water molecules on the oxide surface can considerably impair sensor sensitivity and overall performance. To address this issue, in this paper, we report on the application of an ultrathin, hydrophobic layer of hexamethyldisilazane to the surface of a Pd/SnO 2 sensor. This study investigates the influence of hydrophobic surface modifications on the metal oxide interface, focusing on their impact on sensor sensitivity and selectivity. The resulting sensor exhibits superior hydrogen sensing capabilities, operating effectively at low temperatures even in high humidity environments. Furthermore, the hydrophobic modification reduces the sensor’s susceptibility to interfering gases, thus enhancing its selectivity. The combined enhancements in moisture resistance and selectivity achieved through HMDS surface modification, along with the superior sensitivity of Pd/SnO₂ sensors, facilitate the development of gas sensors with enhanced humidity tolerance and broader applications.

Chemiresistive gas sensors↗

Adhesion mechanisms on solar glass: Effects of relative humidity, surface roughness, and particle shape and size

To better understand and quantify soiling rates on solar panels, we are investigating the adhesion mechanisms between dust particles and solar glass. In this work, we report on two of the fundamental adhesion mechanisms: van der Waals and capillary adhesion forces. The adhesion was determined using force versus distance (F-z) measurements performed with an atomic force microscope (AFM). To emulate dust interacting with the front surface of a solar panel, we measured how oxidized AFM tips, SiO 2 glass spheres, and real dust particles adhered to actual solar glass. The van der Waals forces were evaluated by measurements performed with zero relative humidity in a glove box, and the capillary forces were measured in a stable environment created inside the AFM enclosure with relative humidity values ranging from 18% to 80%. To simulate topographic features of the solar panels caused by factors such as cleaning and abrasion, we induced different degrees of surface roughness in the solar glass. As a result, we were able to 1) identify and quantify both the van der Waals and capillary forces, 2) establish the effects of surface roughness, relative humidity, and particle size on the adhesion mechanisms, and 3) compare adhesion forces between well-controlled particles (AFM tips and glass spheres) and real dust particles.

14 SOLAR ENERGY↗

Brittle-to-Ductile Transitions of Polyelectrolyte Complexes: Humidity, Temperature, and Salt

Polyelectrolyte complexation is an entropically driven, associative phase separation that results in a polymer-rich polyelectrolyte complex (PEC) and a polymer-poor supernatant. PECs show promise as a new class of sustainable materials since they can be processed using aqueous solutions rather than organic solvents. Previous reports have looked at the mechanical properties and glass transitions of PECs as a function of temperature, relative humidity (rH), and salt concentration (CS), but establishing a universal understanding of how these parameters affect PEC mechanics has yet to be achieved. We examined the effects of temperature, rH, and CS on the mechanical properties of PECs formed from poly(methacrylic acid) and poly(trimethyl aminoethyl methacrylate) with a goal of establishing design rules for their mechanical response. Relative humidity was shown to have the most dramatic effect on the mechanical properties, with temperature and salt concentration having far less of an impact. Furthermore, we observed that the glass transition of PECs is tied to both temperature and relative humidity, creating a glass transition rH g /T g line that can be modulated by added salt. Finally, we looked at the thermodynamics behind the glass transition of PECs, which yielded similar energies as the condensation of water. Here, we propose the use of water and/or salt as a low energy and efficient method of processing PECs for various applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Elimination of Response to Relative Humidity Changes in Chemical-Sensitive Field-Effect Transistors

Detecting accurate concentrations of gas in environments with dynamically changing relative humidity conditions has been a challenge in gas sensing technology. Here, we report a method to eliminate effects of humidity response in chemical-sensitive field-effect transistors using microheaters. Using a hydrogen gas sensor with Pt/FOTS active material as a test case, we demonstrate that a sensor response of 3844% to a relative humidity change of 50 to 90% at 25 °C can be reduced to a negligible response of 11.6% by utilizing microheaters. We also show the advantage of this technique in maintaining the same sensitivity in changing ambient temperatures and its application to the nitrogen dioxide gas sensors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Insights into Sustainable Nitrogen Fixation by Gas-phase Spectroscopic Measurements and Global Modeling of Reaction Intermediates in Humid Nitrogen Plasma

In this article, there is growing interest in reacting molecular nitrogen and water to sustainably synthesize fixed forms of nitrogen such as ammonia. In particular, low-temperature plasmas can activate these relatively inert feedstocks at or near room temperature without a catalyst. However, because of the enhanced reactivity and nonequilibrium chemistry, a diverse range of products is formed, and the underlying reaction mechanisms are exceedingly complex. In this work, we studied a simplified reactor consisting of a gaseous plasma containing controlled mixtures of nitrogen gas and water vapor. Densities of key chemical species such as N, H, OH, NH, and NO were measured by emission and laser-based spectroscopy as a function of the relative humidity. A global model was constructed and the reaction network was validated by comparing calculated species densities with experiments. We discover that N, a key initial intermediate for ammonia, strongly decreases in the presence of water vapor, and as a result, ammonia formation becomes limited at high relative humidity. This decrease is surprisingly not because N itself reacts, but because one of its main sources, an excited molecular nitrogen state, is reacted away. In addition, oxidation pathways for nitrogen, which lead to NO and related products, are found to be favored over reduction pathways because the corresponding reverse reactions are less significant. Together, this understanding helps explain previously reported observations of selectivity toward nitrogen oxides over ammonia, particularly at higher relative humidities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Gelatin as a new humidity sensing material: Characterization and limitations

The goal of this work is to assert the utility of collagen and its denatured counterpart gelatin as cost-effective alternatives to existing sensing layers comprised of polymers. Rather than producing a material that will need to be discarded or recycled, collagen, as a by-product of the meat and leather industry, could be repurposed. This work examines the feasibility of using collagen as a sensing layer. Planar electrodes were patterned with lift-off process to work with the natural characteristics of gelatin by utilizing metal vapor deposition, spin coating, and photolithography. Characterization methods have also been optimized through the creation of specialized humidity chambers that isolate specific characteristics such as response time, accuracy, and hysteresis. Collagen-based sensors are found to have a sensitivity to moisture in the range of 0.065 pF/%RH. Diffusion characteristics were also analyzed with the diffusion coefficient found to be 2.5 × 10{sup −5} cm{sup 2}/s. Absorption and desorption times were found to be 20 seconds and 8 seconds, respectively. Hysteresis present in the data is attributed to temperature cross-sensitivity. Ultimately, the utility of collagen as a dielectric sensing material is, in part, due to its fibrous macrostructures as well its hydrophilic sites along the peptide chains. Gelatin was patterned between and below interdigitated copper electrodes and tested as a relative humidity sensor. This work shows that gelatin, which is inexpensive, widely available, and easy to process, can be an effective dielectric sensing polymer for capacitive-type relative humidity sensors.

36 MATERIALS SCIENCE↗

Measurement of the radon diffusion through a nylon foil for different air humidities

The dependency of the radon penetration through a nylon foil on air humidity was measured. Such information is needed for the tracking part of the SuperNEMO detector, which is planned to be shielded against radon by nylon foil and in which the air humidity is not negligible. The long term measurements of radon penetration through nylon foils for different air humidities were performed with the radon diffusion setup constructed at the IEAP, CTU in Prague. The setup consists of two stainless steel hemispheres with Si detector in each of them. Both hemispheres are separated by the tested foil. While the left hemisphere contains high Rn activity, the right part contains only activity caused by the radon penetration through the tested foil. Obtained results of this study with a nylon foil with the thickness of 50 µm are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low-noise humidity controller for imaging water mediated processes in atomic force microscopy

We demonstrate the construction of a novel low-noise continuous flow humidity controller and its integration with a commercial variable-temperature atomic force microscope fluid cell, allowing precise control of humidity and temperature at the sample during nanoscale measurements. Based on wet and dry gas mixing, the design allows a high mechanical stability to be achieved by means of an ultrasonic atomiser for the generation of water-saturated gas, improving upon previous bubbler-based architectures. Water content in the flow is measured both at the inflow and outflow of the fluid cell, enabling the monitoring of water condensation and icing, and allowing controlled variation of the sample temperature independently of the humidity. To benchmark the performance of the controller, the results of detailed noise studies and time-based imaging of the formation of ice layers on highly oriented pyrolytic graphite are shown.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Humidity Bias and Effect on Simulated Aerosol Optical Properties during the Ganges Valley Experiment

The radiosonde humidity profiles available during the Ganges Valley Experiment were compared to those simulated from the regional Weather Research and Forecasting (WRF) model coupled with a chemistry module (WRF -Chern) and the global reanalysis datasets. Large biases were revealed. On a monthly mean basis at Nainital, located in northern India, the WRFChern model simulates a large moist bias in the free troposphere (up to +20%) as well as a large dry bias in the boundary layer (up to -30%). While the overall pattern of the biases is similar, the magnitude of the biases varies from time to time and from one location to another. At Thiruvananthapuram, the magnitude of the dry bias is smaller, and in contrast to Nainital, the higher-resolution regional WRF -Chern model generates larger moist biases in the upper troposphere than the global reanalysis data. Furthermore, the humidity biases in the upper troposphere, while significant, have little impact on the model estimation of column aerosol optical depth (AOD). The frequent occurrences of the dry boundary-layer bias simulated by the large-scale models tend to lead to the underestimation of AOD. It is thus important to quantify the humidity vertical profiles for aerosol simulations over South Asia.

aerosol extinction↗

Humidity Data for 9975 Shipping Packages with Softwood Fiberboard

The 9975 surveillance program is developing a technical basis to support extending the storage period of 9975 packages in K-Area Complex beyond the currently approved 15 years. A key element of this effort is developing a better understanding of degradation of the fiberboard assembly under storage conditions. This degradation is influenced greatly by the moisture content of the fiberboard, which is not well characterized on an individual package basis. Direct measurements of humidity and fiberboard moisture content have been made on two test packages with softwood fiberboard and varying internal heat levels from 0 up to 19W. Comparable measurements with cane fiberboard have been reported previously. With an internal heat load, a temperature gradient in the fiberboard assembly leads to varying relative humidity in the air around the fiberboard. However, the absolute humidity tends to remain approximately constant throughout the package, especially at lower heat loads.

42 ENGINEERING↗

Relative humidity threshold for oxygen generation by high-purity plutonium dioxides in 3013 containers

High-purity plutonium dioxide with adsorbed water in a sealed container can generate oxygen, but oxygen will not be generated in low water loading conditions. A threshold for oxygen generation has been observed in the hydrogen generation rate normalized by the specific power for high-purity plutonium dioxide. Normalized hydrogen generation rates above this threshold generate oxygen and below the threshold consume oxygen. The threshold rate is determined by the amount of water adsorbed onto the surface of the oxide. The relative humidity of the atmosphere that the oxide is in equilibrium with determines the amount of physisorbed water adsorbed on the surface. We calculate the relative humidity corresponding to the threshold rate as a function of mass and specific surface area of material stored in 3013 containers. Exceeding the calculated relative humidity may result in flammable gas mixtures of hydrogen and oxygen at some time during storage.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Moisture Performance of Unvented Attics With Vapor Diffusion Ports and Buried Ducts in Hot, Humid Climates

Energy efficiency measures, such as cool roofs, radiant barriers, interior radiative control coatings, and buried ducts are increasing in popularity and are promoted by energy codes because of their energy-saving potential. However, these strategies can also pose moisture risks in attics by lowering surface temperatures and increasing condensation potential and moisture accumulation. Of particular concern in hot-humid climates is dripping condensation on cold air-conditioning ductwork in the summer - commonly referred to as duct "sweating" - which threatens the attic floor with conditions conducive to mold growth and rot. One strategy to mitigate these moisture issues is to wrap ductwork in thicker duct-wrap insulation with an integrated exterior vapor barrier, but thick duct wrap can be difficult to come by, expensive, and unwieldy to work with. This study explores an alternative strategy of reducing moisture issues while embracing energy efficiency by using unvented attics with vapor diffusion ports and buried ductwork in hot-humid climates. Vapor diffusion ports have been studied so far in a wide range of U.S. climates, mostly in the context of conditioned attics. In this study, the strategy is implemented in the novel context of hot-humid climates with ductwork sitting atop blown-in attic floor insulation in unconditioned attics. Using a combination of field experiments and hygrothermal modeling, the findings of this project indicate that an unvented attic with vapor diffusion ports and buried ducts may be a key part of a successful low-cost method for reducing the attic moisture load by venting excess moisture out of the attic, keeping duct-jacket surfaces above dew point temperature, and keeping the roof deck safe from winter moisture accumulation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field Testing Unvented Roofs with Asphalt Shingles in Cold and Hot-humid Climates

BSC TO5 Task 7.1 Field Testing Unvented Roofs with Asphalt Shingles in Cold Climates - Bolingbrook, IL 60440 BSC TO5 Task 7.1 Field Testing Unvented Roofs with Asphalt Shingles in Hot-Humid Climates - Friendswood, TX 77546 To understand the long-term moisture performance of unvented roof assemblies with fibrous insulation, the U.S. Department of Energy's Building America team Building Science Corporation built and monitored test roofs in two climates: a cold-climate test house in Bolingbrook, Illinois (Chicago area; zone 5A), and a hot-humid test house in Friendswood, Texas (Houston area, zone 2A). The Chicago-area test bed had seven parallel experimental rafter bays. The assemblies included a control vented compact (cathedral) roof, a dense-pack cellulose unvented roof, and an unvented roof with a "diffusion vent" (a strip of vapor-permeable gypsum sheathing at the ridge to allow drying). The interior finish was gypsum wallboard (GWB) with latex paint. The other four bays were top vent roof assemblies, which have a polypropylene breather mesh between the roof sheathing and the asphalt shingles to allow ventilation drying of the assembly from underneath the vapor-impermeable shingles. Two of the four "top vent" roofs were fiberglass batt and two were dense-pack cellulose roofs with either interior GWB or open to the interior. Wintertime moisture-related failure was accelerated by providing interior humidification (22.2 degree C [72 degree F]/50% relative humidity [RH]), which is known to be an extreme interior loading). Data were captured over 8 months, including a winter and the following spring and early summer.

Array↗

Accuracy of Vaisala RS41 and RS92 Upper Tropospheric Humidity Compared to Satellite Hyperspectral Infrared Measurements

Radiosondes are important for calibrating satellite sensors and assessing sounding retrievals. Vaisala RS41 radiosondes have mostly replaced RS92 in the Global Climate Observing System (GCOS) Reference Upper Air Network (GRUAN) and the conventional network. This study assesses RS41 and RS92 upper tropospheric humidity (UTH) accuracy by comparing with Infrared Atmospheric Sounding Interferometer (IASI) upper tropospheric water vapor absorption spectrum measurements. Using single RS41 and RS92 soundings at three GRUAN and DOE Atmospheric Radiation Measurement (ARM) sites and dual RS92/RS41 launches at three additional GRUAN sites, collocated with cloud-free IASI radiances (OBS), we compute Line-by-Line Radiative Transfer Model radiances for radiosonde profiles (CAL). We analyze OBS-CAL differences from 2015 to 2020, for daytime, nighttime, and dusk/dawn separately if data is available, for standard (STD) RS92 and RS41 processing, and RS92 GRUAN Data Processing (GDP; RS41 GDP is in development). We find that daytime RS41 (even without GDP) has ~1% smaller UTH errors than GDP RS92. RS41 may still have a dry bias of 1–1.5% for both daytime and nighttime, and a similar error for nighttime RS92 GDP, while standard RS92 may have a dry bias of 3–4%. These sonde humidity biases are probably upper limits since “cloud-free” scenes could still be cloud contaminated. Radiances computed from European Centre for Medium-Range Weather Forecasts (ECMWF) analyses match better than radiosondes with IASI measurements, perhaps because ECMWF assimilates IASI measurements. Relative differences between RS41 STD and RS92 GDP, or between radiosondes and ECMWF humidity profiles obtained from the radiance analysis, are consistent with their differences obtained directly from the RH measurements.

54 ENVIRONMENTAL SCIENCES↗