Reusable Hot-Wire Cable Cutter

During the early development stage of balloon deployment systems for missions, nichrome wire cable cutters were often used in place of pyro-actuated cutters. Typically, a nichrome wire is wrapped around a bundle of polymer cables with a low melting point and connected to a relay-actuated electric circuit. The heat from the nichrome reduces the strength of the cable bundle, which quickly breaks under a mechanical load and can thus be used as a release mechanism for a deployment system. However, the use of hand-made heated nichrome wire for cutters is not very reliable. Often, the wrapped nichrome wire does not cut through the cable because it either pulls away from its power source or does not stay in contact with the cable being cut. Because nichrome is not readily soldered to copper wire, unreliable mechanical crimps are often made to connect the nichrome to an electric circuit. A self-contained device that is reusable and reliable was developed to sever cables for device release or deployment. The nichrome wire in this new device is housed within an enclosure to prevent it from being damaged by handling. The electric power leads are internally connected within the unit to the nichrome wire using a screw terminal connection. A bayonet plug, a quick and secure method of connecting the cutter to the power source, is used to connect the cutter to the power leads similar to those used in pyro-cutter devices. A small ceramic tube [0.25-in. wide 0.5-in. long (.6.4-mm wide 13-mm long)] houses a spiraled nichrome wire that is heated when a cable release action is required. The wire is formed into a spiral coil by wrapping it around a mandrel. It is then laid inside the ceramic tube so that it fits closely to the inner surface of the tube. The ceramic tube provides some thermal and electrical insulation so that most of the heat generated by the wire is directed toward the cable bundle in the center of the spiral. The ceramic tube is cemented into an aluminum block, which holds it in position. The leads of the nichrome wire are attached to screw terminals that connect them to power leads. A bayonet plug mounted at the bottom of the rectangular block connects the power leads to a relay circuit. A thin aluminum shell encloses the entire structure, leaving access points to attach to the bayonet plug and to feed a cable into the cylinder. The access holes for the deployment cable are a smaller diameter than the nichrome coil to prevent the cable from coming in direct contact with the nichrome when loaded. It uses the same general method of severing a cable with a heated wire as was used previously, but implements it in such a way that it is more reliable and less prone to failure. It creates a mechanism to create repeatability that was nonexistent in the previous method.

Pauken, Michael T.↗

Analysis of Hot-Wire Probe Ice Water Content Measurements in High Ice Water Content Conditions

During the 2022 High Ice Water Content (HIWC) Flight Campaign, ice water content (IWC) measurements were made at various locations on the NASA DC-8 Airborne Science Laboratory using the Isokinetic Probe Version 2 (IKP2), Ice Crystal Detectors (ICD), and Robust Probe. Correlations of a wing mounted ICD to IKP2 were made to determine the collision/retention efficiency of the ICD total water content (TWC) element in glaciated conditions. Similarly, correlations of a nose mounted ICD near the pitot probes were made to the IKP2 and to the wing-mounted ICD to estimate the ice concentration factor near the DC-8 pitot probes. Results from the 2022 flight campaign were compared to results from the HIWC RADAR II flight campaign in 2018. There was an apparent reduction in the ICD TWC collision/retention efficiency during the 2022 flight campaign. Although reasons for this discrepancy were explored, more analyses are needed to fully understand the causes. However, it was concluded that an estimated ice concentration factor at the nose of 2.5 was consistent between the two flight campaigns. Additionally, a correlation model was developed to relate measurements from a Nose ICD to freestream IWC as measured by the IKP2 to support IWC measurements from the 2022 Convective Processes Experiment - Cabo Verde (CPEX-CV) flight campaign.

Icing↗

Analysis of Hot-Wire Probe Ice Water Content Measurements in High Ice Water Content Conditions

During the 2022 High Ice Water Content (HIWC) Flight Campaign, ice water content (IWC) measurements were made at various locations on the NASA DC-8 Airborne Science Laboratory using the Isokinetic Probe Version 2 (IKP2), Ice Crystal Detectors (ICD), and Robust Probe. Correlations of a wing mounted ICD to IKP2 were made to determine the collision/retention efficiency of the ICD total water content (TWC) element in glaciated conditions. Similarly, correlations of a nose mounted ICD near the pitot probes were made to the IKP2 and to the wing-mounted ICD to estimate the ice concentration factor near the DC-8 pitot probes. Results from the 2022 flight campaign were compared to results from the HIWC RADAR II flight campaign in 2018. There was an apparent reduction in the ICD TWC collision/retention efficiency during the 2022 flight campaign. Although reasons for this discrepancy were explored, more analyses are needed to fully understand the causes. However, it was concluded that an estimated ice concentration factor at the nose of 2.5 was consistent between the two flight campaigns. Additionally, a correlation model was developed to relate measurements from a Nose ICD to freestream IWC as measured by the IKP2 to support IWC measurements from the 2022 Convective Processes Experiment - Cabo Verde (CPEX-CV) flight campaign.

Icing↗

Single-wire swirl flow turbulence measurements

A six-orientation, single wire hot wire technique is used to investigate nonswirling and swirling nonreacting flow in an axisymmetric test section with expansion ratio (test section/inlet nozzle diameter) = 2, which may be equipped with a strong contraction nozzle of area ratio 4 at a contraction nozzle downstream distance/test section diameter value = 2. The flowfield contains corner and central recirculation zones typical of gas turbine and ramjet combustion chambers. Swirl may be imparted to the incoming flow by means of a variable angle vane swirler. The effect of swirl on time mean velocities and complete Reynolds stress tensor is investigated, and extensive results are given for swirl vane angles of zero (swirler removed), 38, 45, 60 and 70 deg. The data are being used to aid in the evolution of turbulence models for these complex flow situations. A directional sensitivity analysis is included, which determines the relative accuracy of the measurement technique to approach velocity orientation.

Lilley, D. G.↗

A critical analysis of transverse vorticity measurements in a large plane shear layer

An evaluation is made of the roles played in four-wire hot wire probe arrays by the influence of (1) the transverse velocity component on pitch angle measurement; (2) the instantaneous spatial gradient of the pitch angle on transverse vorticity computation; (3) the uncertainties in the magnitude of instantaneous pitch angle spatial gradient in the transverse vorticity computation; and (4) the spatial dimension of the microcirculation domain and the evaluation of transverse vorticity. Attention is given to the probe configuration and its computation algorithm.

Foss, J. F.↗

Flow quality measurements in compressible subsonic flows

The purpose is to re-examine the heat transfer from a hot-wire probe in the compressible subsonic flow regime; describe the three-wire hot-wire probe calibration and data reduction techniques used to measure the velocity, density, and total temperature fluctuation; and present flow quality results obtained in the Langley 0.3 meter Transonic Cryogenic Wind Tunnel and in flight with the NASA JetStar from the same three-wire hot-wire probe.

Stainback, P. Calvin↗

Analysis of wake vortex flight test data behind a T-33 aircraft

Measurements of the vortex system behind a T-33 aircraft were obtained by a Learjet equipped with a boom carrying a three-wire, hot-wire anemometry probe and other instrumentation. Analysis of the measurements using a computerized geometric method indicated the vortices had a core radius of approximately 0.11 meter with a maximum velocity of 25 meters per second. The hot-wire anemometer was found to be a practical and sensitive instrument for determining in-flight vortex velocities. No longitudinal instabilities, buoyant effects or vortex breakdowns were evident in the data which included vortex wake cross sections from 0.24 to 5.22 kilometers behind the T-33.

Kuhn, G. D.↗

Developments in the large angle oblique jet impingement flow investigation

Single-wire (hot-wire) measurements are presented of the mean velocity and turbulence quantities near the impact plate for a 45-degree impingement flow responsible for acoustic noise production. These results are summarized along with the conclusions which shaped the subsequent direction of the study of large angle oblique jet impingement flow. The development of a unique signal processing circuit for finding the instantaneous transverse vorticity from an array of four hot-wires is discussed.

Foss, J. F.↗

Instrument for Aircraft-Icing and Cloud-Physics Measurements

The figure shows a compact, rugged, simple sensor head that is part of an instrumentation system for making measurements to characterize the severity of aircraft-icing conditions and/or to perform research on cloud physics. The quantities that are calculated from measurement data acquired by this system and that are used to quantify the severity of icing conditions include sizes of cloud water drops, cloud liquid water content (LWC), cloud ice water content (IWC), and cloud total water content (TWC). The sensor head is mounted on the outside of an aircraft, positioned and oriented to intercept the ambient airflow. The sensor head consists of an open housing that is heated in a controlled manner to keep it free of ice and that contains four hot-wire elements. The hot-wire sensing elements have different shapes and sizes and, therefore, exhibit different measurement efficiencies with respect to droplet size and water phase (liquid, frozen, or mixed). Three of the hot-wire sensing elements are oriented across the airflow so as to intercept incoming cloud water. For each of these elements, the LWC or TWC affects the power required to maintain a constant temperature in the presence of cloud water.

Lilie, Lyle↗

Measuring the Liquid Content of a Gas

Instrument is adaptation of hot-wire anemometer. Hot-wire anemometer detects liquid droplets entrained in flowing gas. Droplets impinge on probe and carry away heat as vaporized. Power required to maintain probe at constant resistance and elevated temperature gives measure of amount of liquid present. Instrument used in steam turbines to check for condensation and detect fog at airports and highways, generating control signal to turn on fog lights.

Beekman, D. H.↗

Comparison of hot wire/laser velocimeter turbulence intensity measurements

The question of whether a random measure of particle velocities yields a good statistical estimate of the stationary condition of the turbulence flow field was investigated by comparing hot-wire and laser velocimeter turbulence intensity measurements. Great care was taken to insure that the instrument precision of both the laser velocimeter and hot wire was maximized. In this attempt to reduce the measurement uncertainties in the hot wire, direct digitization of the analog output signal was performed with point-by-point conversion to velocity through a spline fit calibration curve and the turbulence intensity function was calculated statistically. Frequent calibrations of the hot wire were performed using the laser velocimeter as the velocity standard to account for the presence of the small seed particles in the air flow and signal drift in the hot wire.

Meyers, J. F.↗

Spacecraft Cabin Ventilation Fan: Wake Measurements Results

Quiet, efficient fans with minimal vibrations are required for revitalization system fans used for human support system in long duration space exploration missions. A spacecraft cabin ventilation fan suitable for aerodynamic and acoustic ground tests was designed in NASA Glenn research center. Two copies of the fan assembly were fabricated and tested for aerodynamic performance and acoustic levels in the NASA Glenn Research Center Acoustical Testing Laboratory. A new test rig for small axial flow fans was designed to accommodate the instrumentation and back-pressure adjustments. Measurements acquired were from: static pressures for measuring performance, a 72-channel in-duct microphone array, external microphone measurements for acoustics, and inter-stage hot-wire measurements of the fan wake. Hot-wire measurements were obtained by radially traversing a x-wire probe downstream of the rotor. This report documents the phase-locked wake velocity, flow angle and turbulence measurements from the hot-wire surveys as part of a series of reports.

Hotwire Measurement↗

Review of experimental work on transonic flow in turbomachinery

The review is primarily concerned with modern experimental techniques of high response and laser supported instrumentation. The considered techniques make it possible to obtain detailed data of steady and unsteady processes occurring inside transonic blade rows and in the vicinity of the rows. Such data are needed for the verification of computer codes used for the study of the operational characteristics of turbomachinery. Attention is given to high response transducers, hot wire probes, hot film gages, laser Doppler velocimeter systems, laser fluorescence, and laser holography.

Mcnally, W. D.↗

An experimental study of the noise generating mechanisms in supersonic jets

Flow fluctuation measurements with normal and X-wire hot-wire probes and acoustic measurements with a traversing condenser microphone were carried out in small air jets in the Mach number range from M = 0.9 to 2.5. One of the most successful studies involved a moderate Reynolds number M = 2.1 jet. The large scale turbulence properties in the jet, and the noise radiation were characterized. A parallel study involved similar measurements on a low Reynolds number M = 0.9 jet. These measurements show that there are important differences in the noise generation process of the M = 0.9 jet in comparison with low supersonic Mach number (M = 1.4) jets. Problems encounted while performing X-wire measurements in low Reynolds number jets of M = 2.1 and 2.5, and in installing a vacuum pump are discussed.

Mclaughlin, D. K.↗

Investigations of flowfields found in typical combustor geometries

Measurements and computations are being applied to an axisymmetric swirling flow, emerging from swirl vanes at angle phi, entering a large chamber test section via a sudden expansion of various side-wall angles alpha. New features are: the turbulence measurements are being performed on swirling as well as nonswirling flow; and all measurements and computations are also being performed on a confined jet flowfield with realistic downstream blockage. Recent activity falls into three categories: (1) Time-mean flowfield characterization by five-hole pitot probe measurements and by flow visualization; (2) Turbulence measurements by a variety of single- and multi-wire hot-wire probe techniques; and (3) Flowfield computations using the computer code developed during the previous year's research program.

Lilley, D. G.↗

Preliminary measurements of velocity, density and total temperature fluctuations in compressible subsonic flow

The heat transfer characteristics of a three-wire hot-wire probe operated with a constant temperature anemometer were investigated in the subsonic compressible flow regime. The sensitivity coefficients, with respect to velocity, density and total temperature, were measured and the results were used to calculate the velocity, density, and total temperature fluctuations in the test section of the Langley 0.3-m Transonic Cryogenic Tunnel (TCT). These results were extended to give estimates for fluctuations due to vorticity, sound, and entropy. In addition, attempts were made to determine the major source of disturbances in the 0.3-m TCT.

Stainback, P. C.↗

Swirl, confinement and nozzle effects on confined turbulent flow

Predictions of swirl, confinement and nozzle effects on confined turbulent flow are exhibited and compared with five-hole pitot-probe time-mean velocity measurements. Two sets of computations are given, one using the standard k-epsilon turbulence model and the other using a C sub mu formulation model deduced from recent six-orientation single-wire hot-wire measurements. Results confirm that the accuracy of the latter model is superior. To highlight the effects of confinement and exit nozzle area on this flow, three expansion ratios and two contraction ratios are used. Predictions are given for a full range of swirl strengths using measured inlet conditions for axial, radial and swirl velocity profiles. The predicted velocity profiles illustrate the large-scale effects of inlet swirl on flowfields. It appears that a strong contraction nozzle has a pronounced effect, on swirl flow cases, with discouragement of central recirculation zones, and forward flow in highly swirled vortex core regions. The expansion ratio value has large-scale effects on the size and location of the recirculation zones.

Abujelala, M. T.↗