Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “homes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

DOE Zero Energy Ready Home Case Study HIA 2021: Martha Rose Construction, Abbot’s Alley Net Zero, Sedro Wooley, WA

Case study of a DOE 2021 Housing Innovation Award winning custom home in a marine climate that got a HERS -13 with PV, with 1,804 square feet, highly efficient construction; high-efficiency ductless minisplit heat pumps, appliances, and lighting; triple-pane windows; and 9.9 kW of solar panels on each of the monoplane roofs.

Building America, residential construction, home b↗

Home energy management under realistic and uncertain conditions: A comparison of heuristic, deterministic, and stochastic control methods

We report home energy management systems (HEMS) have been shown to reduce energy bills and to provide grid services including peak demand reduction and demand flexibility. However, uncertainty in residential energy systems is a significant issue and can reduce the benefits of a HEMS to the homeowner or grid operator. Sources of uncertainty include weather forecasts, predictions of energy-related occupant activities (e.g., hot water draws), and parameter estimation for the building envelope and energy-consuming equipment. This paper tackles the problem of uncertainty by developing a framework that simulates HEMS in uncertain conditions and evaluates the performance of multiple control strategies. A linear, reduced-order residential building model for model predictive control applications is derived and compared to a full-order model. Stochastic model predictive control is shown to perform better than deterministic and heuristic methods when considering realistic forecasts with uncertainty. The framework can evaluate the performance of HEMS in real-world applications, which can help de-risk HEMS deployment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Potential impact of work from home jobs on residential energy bills: A case study in phoenix, AZ, USA

Nearly one-third of U.S. households face challenges paying energy bills. During the day, many residents have routine access to cooled environments provided by others—employers, shopping centers, and other public buildings. The COVID-19 pandemic, however, has significantly shifted the cost burden of air conditioning in hot cities. Specifically, during the pandemic, many companies either laid off employees or put them in work-from-home (WFH) assignments. Large tech companies are already promoting WFH as a long-term option for their employees, even after the pandemic. This change in the nature of the workforce might reduce daily travel expenses for workers, but could also significantly increase residential energy bills, particularly during summer in very hot climates. Here, this study uses building energy simulations to quantify the potential residential energy bill penalties resulting from WFH for typical residences in Phoenix. Four building archetypes are used in this study to represent variations in building vintage, occupancy, and characteristics. The results show that, for some single-family residences in Phoenix, WFH can increase annual energy bills by more than $1100 (up to a 70% increase). The study also demonstrates that building performance enhancement retrofit measures have the potential to reduce this WFH energy bill penalty for the existing buildings substantially.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Empirical Validation of a Constrained Bin Packing Algorithm for a Home Energy Management System

The increasing number of intelligent electrical appliances and home energy management systems provide a big opportunity for demand response services from residential and small commercial buildings to the grid. Simultaneously, direct control of individual devices by utilities can cause communication bottlenecks, as well as coordination and privacy concerns. These challenges can be addressed by combining the constituent devices into a single house battery equivalent for the purposes of demand response, using Minkowski sum and a 2d bin packing problem. However, the well-studied traditional problems have not been tested in a real house, as implementation carries significant challenges of its own. We deploy the packing problem on residential devices in a controllable house. We report the barriers we found, such as charge forecast and scalability of the algorithm, and discuss our solutions. The study serves as an intermediate step between existing theoretical research and possible future steps, such as prototype deployments of systems that provide residential demand response.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Magnetotelluric Data from Mountain Home, ID

This dataset includes magnetotelluric transfer functions in the form of EDI files for 16 stations collected by the USGS and 40 stations collected by Quantec Geoscience for Lawerence Berkeley National Lab around the Mountain Home area in Idaho. A 3D electrical resistivity model is included that images resistive and conductive bodies in the subsurface that maybe important for geothermal characterization. The model was created using ModEM using the high performance computer Yeti at the USGS.

15 GEOTHERMAL ENERGY↗

Honda Smart Home - Davis, CA

The Honda Smart Home demonstrates zero-carbon living and transportation capacity.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Residential Home Repairs, Energy Efficiency, and Electrification in the Hill District of Pittsburgh [Slides]

Through Communities LEAP, a community coalition focused on the Hill District neighborhood of Pittsburgh is working with a technical assistance provider network led by the National Renewable Energy Laboratory (NREL). The coalition includes community organizations, nonprofits, the city government, and the utility. Technical assistance provides analysis and information to support Hill District stakeholders in their goals to create informed residential energy efficiency and renewable energy transition strategies. This report summarizes the insights from stakeholder engagement with organizations that provide home repair services, weatherization, and residential energy efficiency in the Hill District as well as from a building analysis to characterize Hill District housing stock and the potential costs and benefits of energy efficiency and electrification measures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Efficiency Field Study: Influence of Key Measures in Home Rules States

The goal of the Energy Efficiency Field Study: Influence of Key Measures in Home Rule States project is to empower and support the states of Utah and Arizona in the successful implementation of their building energy codes. Employing the Department of Energy (DOE) Residential Building Energy Code Field Study Data Collection & Methodology, the research team evaluated real-world implementation status against a baseline, with a particular focus on the unique challenges presented by the dry, hot climates of Utah and Arizona.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Housing-Performance Atlas of Baltimore Row Homes: Archetype-Based Multi-Hazard Baseline of Energy, Heat, Survivability, and Durability

Baltimore’s historic row-home neighborhoods face escalating risks to energy, heat, and durability under intensifying climate stress. This study develops a Housing-Performance Atlas that quantifies multi-hazard performance for eight representative archetypes using DesignBuilder/EnergyPlus Version 7.3.1.003, under Baltimore TMY3 boundary conditions. Performance is evaluated across the following four adaptation domains: energy use intensity, passive survivability during 72 h outage events, roof overheating exposure (>150 °F exceedance hours), and material service life derived from ISO 15686 and synthesized into Lean and Full Deficit Indices for comparative resilience ranking. Results show that EUI ranged from 46.7 to 67.6 kBtu ft −2 ·yr −1 , survivability from 0 to 23 h, and roof temperatures exceeded 150 °F for 150–210 h, shortening roof service life by up to 10 years. Composite Lean and Full Deficit Indices ranged 7.8–92.4, ranking Model 5 (end-unit, flat roof, two-story with basement) as the most resilient configuration and Model 8 (end-unit, pitched roof, three-story above-grade) as the least resilient due to compounded overheating and energy losses. Heat-related domains accounted for nearly 70% of overall resilience deficits, confirming thermal safety and roof reflectivity as retrofit priorities. The Housing-Performance Atlas establishes a reproducible diagnostic framework linking simulation, service life, and resilience metrics to guide cost-effective, climate-responsive retrofits in Baltimore’s aging urban housing stock.

Housing-Performance atlas↗

Sensitivity-Informed Bayesian Inference for Home PLC Network Models with Unknown Parameters

Bayesian inference is used to calibrate a bottom-up home PLC network model with unknown loads and wires at frequencies up to 30 MHz. A network topology with over 50 parameters is calibrated using global sensitivity analysis and transitional Markov Chain Monte Carlo (TMCMC). The sensitivity-informed Bayesian inference computes Sobol indices for each network parameter and applies TMCMC to calibrate the most sensitive parameters for a given network topology. A greedy random search with TMCMC is used to refine the discrete random variables of the network. This results in a model that can accurately compute the transfer function despite noisy training data and a high dimensional parameter space. The model is able to infer some parameters of the network used to produce the training data, and accurately computes the transfer function under extrapolative scenarios.

42 ENGINEERING↗

Validation of HVAC Hardware-in-the-Loop Simulation for Advanced Control Strategies in Smart Homes: Preprint

Residences with smart thermostats can use advanced control strategies to manage their cooling/heating demand, but it is difficult to evaluate optimal control strategies for flexible heating, ventilation, and air conditioning (HVAC) systems in a traditional laboratory setting. The HVAC hardware-in-the-loop (HIL) system combines physical HVAC equipment and a physical thermostat with a simulated house to enable realistic operation of the hardware in any climate. This HIL platform allows researchers to evaluate advanced control strategies for homes with different construction or vintage types, as well as different climates and occupancy schedules. To demonstrate the capabilities of the HVAC HIL system, experimental results with a SEER 16, HSPF 9.5, 3 ton single-speed air source heat pump are validated against past field data collected from a heavily instrumented, unoccupied, retrofit house located in Sacramento, California. Three different cooling strategies are recreated in the HVAC HIL platform, including two different pre-cooling schedules that were designed to shift energy use away from the evening peak. The room temperatures, heat pump energy use, and run time show good agreement between the field data and HIL experimental results for three strategies.

cooling strategies↗

Energy Efficiency and Renewable Energy for New Home Construction in Maui

For residential property owners preparing to rebuild homes in Maui, this fact sheet, produced by the National Renewable Energy Laboratory (NREL), a national laboratory of the U.S. Department of Energy (DOE), provides a brief introduction to the topics of renewable energy and energy efficiency for new residential construction, presents a few high-level considerations and key concepts, and provides a sampling of information on rebates, incentives, certification programs, standards, and relevant policies. This fact sheet is not intended to be comprehensive nor to replace local resources.

appliances↗

Excessive radon-based radiation in indoor air caused by soil building materials in traditional homes on Đồng Văn karst plateau, northern Vietnam

Radon-based radiation from natural soil building materials is an important factor likely influencing residents’ health as a contributing source of natural radiation. This work aims to quantify the nuclide-specific α-radiation of isotopes 222 Rn and 220 Rn in common types of houses in a region of northern Vietnam, Ɖông Văn karst plateau, to preliminarily (i) evaluate the total annual effective dose rates and (ii) assess the relative risk of cancer induction from indoor α-radiation for inhabitants. The average 222 Rn concentrations in all house types were lower than 100 Bq m -3 , but 220 Rn abundances were far higher than 222 Rn, even up to >1000 Bq m -3 in air close to a wall of unfired-soil bricks. The estimated total annual effective dose rates from indoor 222 Rn and 220 Rn and their progenies to residents with daily exposure of 13 h in the various types of houses range from 3.1 to 4.3 mSv a -1 for houses constructed with modified materials, but up to higher than 6 mSv a -1 in houses with raw building materials. The average risk of developing lung cancer as a consequence of a lifetime exposure to indoor α-radiation in affected homes ranges from 3.9% to 14.6%. 220 Rn and its metallic progenies contribute more than 80% of the total average lung cancer risk from total radon, being responsible for a range of 2.7–14.6% of the risk of developing lung cancer.

54 ENVIRONMENTAL SCIENCES↗

Long-Term field testing of the accuracy and HVAC energy savings potential of occupancy presence sensors in A Single-Family home

The energy-saving potential of occupancy-centric smart thermostats has been extensively explored in simulations but lacked field testing for energy savings quantification and sensor performance assessment in real buildings. This paper presents a long-term field study conducted in a single-family home in Texas, U.S. to evaluate the performance of occupancy-centric controls (OCC) of HVAC (heating, ventilation, and air-conditioning) system in terms of energy savings, sensor accuracy, and impact on electric peak demand. The test site was equipped with a commercial off-the-shelf (COTS) smart thermostat and multiple occupancy presence sensors for OCC implementation. Additionally, a sub-metering system was installed to monitor electricity consumption of various end-use equipment, including the HVAC system. A supplementary device was installed to track the ground-truth occupancy for the accuracy evaluation of the occupancy presence sensor. Scenarios of baseline and OCC controls were alternated weekly over the 20-month testing period. The results indicated an effective OCC execution, as evidenced by indoor temperature profiles. During the 2023 cooling season, OCC achieved total energy savings of 1,958 kWh, corresponding to a 17.6% energy savings ratio. Under certain conditions, daily HVAC energy savings reached as high as 17 kWh, with a savings ratio of 35%. Sensor performance showed an overall accuracy of 83.8%, a False Positive Rate (FPR) of 12.8%, and a False Negative Rate (FNR) of 47.4%. A key limitation was the sensor’s inability to detect stationary occupants during sleep, leading to a midnight FNR of nearly 100% and significantly compromising thermal comfort. Additionally, the implementation of OCC resulted in extended periods of high electricity demand on summer afternoons, affecting occupant’s thermal comfort and posing potential challenges to community-level grid operations if OCC were widely adopted. Furthermore, this study addresses a critical research gap by empirically investigating energy-saving potential and occupancy sensor performance in residential buildings. Through a comprehensive field-testing study, the research examines the interrelationship between sensor accuracy, energy savings, and thermal comfort, an area that has received limited attention in the current literature.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Single High-Dose Radiation Enhances Dendritic Cell Homing and T Cell Priming by Promoting Reactive Oxygen Species-Induced Cytoskeletal Reorganization

Radiation therapy (RT) affects tumor-infiltrating immune cells, cooperatively driving tumor growth inhibition. However, there is still no absolute consensus on whether the homing ability of dendritic cells (DCs) is affected by direct x-ray irradiation. Most importantly, the underlying mechanisms are poorly understood.

62 RADIOLOGY AND NUCLEAR MEDICINE↗