High-voltage lithium metal batteries (LMBs) are promising for next-generation high-energy storage systems. Unfortunately, their implementation has been severely plagued by the interfacial instability between the high-voltage cathodes/lithium metal (LM) anodes and electrolytes. To tackle these challenges, a novel nitrile additive, 1,4-dicyanobenzene (DCB) (Synonyms: terephthalonitrile), is added to the in situ polymerized pentaerythritol tetraacrylate-based gel polymer electrolyte (GPE). The DCB additive, as demonstrated both theoretically and experimentally, plays a crucial role in altering the Li+ coordinated solvation structure within the GPE. This alteration leads to the formation of a pseudo-concentrated electrolyte with a tightly packed Li+ cluster, expanding the electrochemical stability window of the electrolyte. Moreover, the DCB-included GPE significantly improves its compatibility with both LM anode and high-voltage cathode, attributed to the modified solvation structure and the generated LiF-rich electrolyte/electrode interphases. Accordingly, the GPE enables stable cyclic performance of LMBs based on a 4.9 V LiNi 0.5 Mn 1.5 O 4 cathode at a low relative negative/positive ratio of 4, achieving a high reversible capacity of 123.8 mAh g -1 with a capacity retention of 87.7% over 500 cycles at 0.5 C. This work provides new insights into enhancing the cyclability of high-voltage LMBs via the synergistic effect of additives and GPE.
Analyte electrolysis using a repetitively pulsed high voltage ion source was investigated and compared to that using a regular, continuously operating direct current high voltage ion source in electrospray ionization mass spectrometry. The extent of analyte electrolysis was explored as a function of the length and frequency of the high voltage pulse using the model compound reserpine in positive ion mode. Using +5 kV as the maximum high voltage amplitude, reserpine was oxidized to its 2, 4, 6 and 8-electron oxidation products when direct current high voltage was employed. In contrast, when using a pulsed high voltage, oxidation of reserpine was eliminated by employing the appropriate high voltage pulse length and frequency. This effect was caused by inefficient mass transport of the analyte to the electrode surface during the duration of the high voltage pulse and the subsequent relaxation of the emitter electrode/ electrolyte interface during the time period when the high voltage was turned off. This mode of ESI source operation allows for analyte electrolysis to be quickly and simply switched on or off electronically via a change in voltage pulse variables.
Explore the source record for details and available documents.
High voltage cable for use in high intensity ionizing radiation fields
High-voltage insulators are disclosed that are capable of handling diverse requirements, such as providing high standoff voltages, high temperature cycling, and the ability to withstand flexural stress. One high-voltage insulator includes a first piece formed from a first material, a second piece formed from a second material, and an interface section where the first piece contacts with and forms a seal with the second piece. The interface includes a first groove located that accommodates a first gasket, sets of matching threads on the first and second pieces. The interface section further accommodates a second gasket. In this multi-piece high-voltage insulator, the first material can have a first set of flexural, heat resistance, and electrical standoff characteristics suitable for a first environment, and the second material can have a second set of flexural, heat resistance and electrical standoff characteristics suitable for a second environment.
High-voltage insulators are disclosed that are capable of handling diverse requirements, such as providing high standoff voltages, high temperature cycling, and the ability to withstand flexural stress. One high-voltage insulator includes a first piece formed from a first material, a second piece formed from a second material, and an interface section where the first piece contacts with and forms a seal with the second piece. The interface includes a first groove located that accommodates a first gasket, sets of matching threads on the first and second pieces. The interface section further accommodates a second gasket. In this multi-piece high-voltage insulator, the first material can have a first set of flexural, heat resistance, and electrical standoff characteristics suitable for a first environment, and the second material can have a second set of flexural, heat resistance and electrical standoff characteristics suitable for a second environment.
Abstract The development of high‐voltage LiCoO 2 is essential for achieving lithium‐ion batteries with high volumetric energy density, however, it faces a great deal of challenges owing to the materials, structure and interfacial instability issues. In this work, a strategy is developed, through heat annealing a precoated surface layer to in situ form a high‐voltage‐stable surface coating layer, which is demonstrated to be highly effective to improve the high‐voltage performance of LiCoO 2 . It is discovered that LiCoO 2 reacts with Li 1.5 Al 0.5 Ti 1.5 (PO 4 ) 3 (LATP) at 700 °C to form exclusively spinel phases in addition to Li 3 PO 4 , which are structurally coherent to the layered lattice of LiCoO 2 . The heat annealing of the precoated thin layer of LATP enables the formation of a high‐quality surface layer. Spinel phases possess high‐voltage‐stable structures with much weaker oxidizing ability of lattice oxygen than layered structure. In addition, the Li 3 PO 4 is a good lithium‐ion conductor with excellent chemical stability at high voltages. All these benefits contribute to the construction of a uniform and conformal high‐voltage‐stable surface layer with favorable lithium conducting kinetics at the LiCoO 2 surface. The modified LiCoO 2 shows excellent 4.6 V high‐voltage cycle performance at both room temperature and 45 °C. The thermal stability is greatly enhanced as well.
High voltage divider system for attenuating high voltages to convenient levels suitable for introduction to measuring circuits
Many space missions proposed for the time period from 1985 to 2000 will require large spacecraft to support the onboard loads. In some cases, large electrical power systems will be needed to supply the electrical/electronic equipment loads. These electronic systems will be used for communications, radar, and experimental equipment for aid to earth's overcrowded communication systems, exploration of new energy resources, space exploration, and eventually to supplement terrestrial electric power utilities. For the near term (1985-1990), some of these systems have power levels to 50 kW. The long-term programs, 1990 to post-2000, could possibly have demands in the order of multimegawatts. The problems which have to be solved to construct the required high-voltage power supply systems are considered. Data and conceptual designs generated are found to indicate that grounding and bonding for high power systems can be accomplished in spacecraft by using either manual or automatic joining of the structural members.
Three high temperature films, polyimide, Teflon perfluoroalkoxy and poly-P-xylene, were evaluated for possible use in high voltage power electronic applications, such as in high energy density capacitors, cables and microelectronic circuits. The dielectric properties, including permittivity and dielectric loss, were obtained in the frequency range of 50 Hz to 100 kHz at temperatures up to 200 C. The dielectric strengths at 60 Hz were determined as a function of temperature to 250 C. Confocal laser microscopy was performed to diagnose for voids and microimperfections within the film structure. The results obtained indicate that all films evaluated are capable of maintaining their high voltage properties, with minimal degradation, at temperatures up to 200 C. However, above 200 C, they lose some of their electrical properties. These films may therefore become viable candidates for high voltage power electronic applications at high temperatures.
The National Aeronautics and Space Administration (NASA) Science Mission Directorate In-Space Propulsion Technology office is sponsoring NASA Glenn Research Center to develop a 4 kW-class Hall thruster propulsion system for implementation in NASA science missions. A study was conducted to assess the impact of varying the facility background pressure on the High Voltage Hall Accelerator (HiVHAc) thruster performance and voltage-current characteristics. This present study evaluated the HiVHAc thruster performance in the lowest attainable background pressure condition at NASA GRC Vacuum Facility 5 to best simulate space-like conditions. Additional tests were performed at selected thruster operating conditions to investigate and elucidate the underlying physics that change during thruster operation at elevated facility background pressure. Tests were performed at background pressure conditions that are three and ten times higher than the lowest realized background pressure. Results indicated that the thruster discharge specific impulse and efficiency increased with elevated facility background pressure. The voltage-current profiles indicated a narrower stable operating region with increased background pressure. Experimental observations of the thruster operation indicated that increasing the facility background pressure shifted the ionization and acceleration zones upstream towards the thruster's anode. Future tests of the HiVHAc thruster are planned at background pressure conditions that are expected to be two to three times lower than what was achieved during this test campaign. These tests will not only assess the impact of reduced facility background pressure on thruster performance, voltage-current characteristics, and plume properties; but will also attempt to quantify the magnitude of the ionization and acceleration zones upstream shifting as a function of increased background pressure.
Not Available
The National Aeronautics and Space Administration (NASA) Science Mission Directorate In-Space Propulsion Technology office is sponsoring NASA Glenn Research Center to develop a 4 kW-class Hall thruster propulsion system for implementation in NASA science missions. A study was conducted to assess the impact of varying the facility background pressure on the High Voltage Hall Accelerator (HiVHAc) thruster performance and voltage-current characteristics. This present study evaluated the HiVHAc thruster performance in the lowest attainable background pressure condition at NASA GRC Vacuum Facility 5 to best simulate space-like conditions. Additional tests were performed at selected thruster operating conditions to investigate and elucidate the underlying physics that change during thruster operation at elevated facility background pressure. Tests were performed at background pressure conditions that are three and ten times higher than the lowest realized background pressure. Results indicated that the thruster discharge specific impulse and efficiency increased with elevated facility background pressure. The voltage-current profiles indicated a narrower stable operating region with increased background pressure. Experimental observations of the thruster operation indicated that increasing the facility background pressure shifted the ionization and acceleration zones upstream towards the thrusters anode. Future tests of the HiVHAc thruster are planned at background pressure conditions that are expected to be two to three times lower than what was achieved during this test campaign. These tests will not only assess the impact of reduced facility background pressure on thruster performance, voltage-current characteristics, and plume properties; but will also attempt to quantify the magnitude of the ionization.
High-voltage (>4.0 V) rechargeable lithium (Li) metal batteries face huge obstacles due to the high reactivity of Li metal with traditional organic carbonate electrolytes. It is generally accepted that ether-based electrolytes are unstable above 4.0 V and thus unsuitable for high voltage applications, despite of their good compatibility with Li metal. Here we report a concentrated ether electrolyte that could be used under high voltage up to 4.5 V with the formation of a unique cathode/electrolyte interphase enriched in LiF, which effectively preserves the cathode crystalline structural integrity. Employing this high concentration ether electrolyte, Li metal batteries with a moderately high cathode loading of 1.5 mAh cm-2 can have a capacity retention of 92% after 500 cycles at 4.3 V and demonstrate nearly 100% cycling efficiency even at 4.5 V.
An improved high-voltage stepping supply, for space instrumentation is described where low power consumption and fast settling time between steps are required. The high-voltage stepping supply, utilizing an average power of 750 milliwatts, delivers a pair of mirror images with 64 level logarithmic outputs. It covers a four decade range of + or - 2500 to + or - 0.29 volts having an output stability of + or - 0.5 percent or + or - 20 millivolts for all line load and temperature variations. The supply provides a typical step setting time of 1 millisecond with 100 microseconds for the lower two decades. The versatile design features of the high-voltage stepping supply provides a quick response staircase generator as described or a fixed voltage with the option to change levels as required over large dynamic ranges without circuit modifications. The concept can be implemented up to + or - 5000 volts. With these design features, the high-voltage stepping supply should find numerous applications where charged particle detection, electro-optical systems, and high voltage scientific instruments are used.
High current photoguns require high power laser light, but only a small portion of the laser light illuminating the photocathode produces electron beam. Most of the laser light (? 65\%) simply serves to heat the photocathode, which leads to evaporation of the chemicals required to create the negative electron affinity condition necessary for photoemission. Photocathode cooling techniques have been employed to address this problem, but active cooling of the photocathode is complicated because the cooling apparatus must float at high voltage. This work evaluates the field emission characteristics of cathode electrodes manufactured from materials with high thermal conductivity: aluminum and copper. These electrodes could serve as effective heat sinks, to passively cool the photocathode that resides within such a structure. However, literature suggests ``soft'' materials like aluminum and copper are ill suited for photogun applications, due to excessive field emission when biased at high voltage. This work provides an evaluation of aluminum and copper electrodes inside a high voltage field emission test stand, before and after coating with titanium nitride (TiN), a coating that enhances surface hardness.