Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “high rate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Plasma Mirrors For High Power Lasers: A new approach for high repetition rates combined with realistic PIC simulations

We describe a research program to develop high quality plasma mirrors for use with high repetition rate, high power laser facilities to greatly facilitate experiments in high energy density physics, particularly when using solid density targets. A system delivering ultrathin, free standing liquid crystal films that could handle PW class laser pulses was developed that preserved the laser beam image quality and improved pulse contrast by over two orders of magnitude. The pulse contrast improvement was measured using a high dynamic range cross-correlation. The system operated at a repetition rate of several PMs formed in situ per minute. Extension to 1 Hz repetition rates should be possible. As a practical application, a PM system was used to separate laser accelerated electrons from the ultrashort pulse drive laser so that the electron beam emittance could be directly measured. The 20 nm thick PMs did not contribute significantly to emittance degradation. It was also demonstrated that the films could operate in the difficult plasma and laser environment present for GeV laser based electron acceleration. PM operation is still not well understood and much work with PMs is done empirically. Accordingly, we also demonstrated a particle-in-cell based simulation technique that would model PM operation, tracking the PM operation from cold, neutral atoms to a hot dense plasma by accounting for multiphoton ionization, plasma collisionality, and the dynamically changing index of refraction. Simulations in 3D were compared to a 2D based approach that was comparable. Finally, we developed a simpler model that can predict the intensity at which a plasma mirror will have its peak reflectivity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Proof-of-concept Talbot–Lau x-ray interferometry with a high-intensity, high-repetition-rate, laser-driven K-alpha source

Talbot–Lau x-ray interferometry is a grating-based phase-contrast technique, which enables measurement of refractive index changes in matter with micrometric spatial resolution. The technique has been established using a variety of hard x-ray sources, including synchrotron, free-electron lasers, and x-ray tubes, and could be used in the optical range for low-density plasmas. The tremendous development of table-top high-power lasers makes the use of high-intensity, laser-driven K-alpha sources appealing for Talbot–Lau interferometer applications in both high-energy-density plasma experiments and biological imaging. To this end, we present the first, to the best of our knowledge, feasibility study of Talbot–Lau phase-contrast imaging using a high-repetition-rate laser of moderate energy (100 mJ at a repetition rate of 10 Hz) to irradiate a copper backlighter foil. The results from up to 900 laser pulses were integrated to form interferometric images. A constant fringe contrast of 20% is demonstrated over 100 accumulations, while the signal-to-noise ratio continued to increase with the number of shots. Phase retrieval is demonstrated without prior ex-situ phase stepping. Instead, correlation matrices are used to compensate for the displacement between reference acquisition and the probing of a PMMA target rod. The steps for improved measurements with more energetic laser systems are discussed. The final results are in good agreement with the theoretically predicted outcomes, demonstrating the applicability of this diagnostic to a range of laser facilities for use across several disciplines.

Bouffetier, V. (ORCID:0000000160791260)↗

On the Strain Rate Sensitivity Measured by Nanoindentation at High Strain Rates

The flow stress of a material can be strongly dependent on the rate of applied strain. Measuring the strain rate sensitivity can reveal key insights into the mechanisms that drive plastic deformation. Indentation techniques have been developed to measure the strain rate sensitivity at quasistatic strain rates, but accessing higher strain rate regimes has been saddled with experimental and technical challenges. With state-of-the-art indentation instrumentation now capable of recording load and displacement at data acquisition rates in excess of 1.25 MHz, we report how strain rate sensitivity testing methodologies, especially those aimed for higher indentation strain rates, may be validated using the well-studied time-dependent deformation behavior of tungsten. Here, the strain rate sensitivity for a (110) single crystal is shown to be consistent (m = 0.023 at 2 µm depth) across all tested strain rates and methods ranging from 10 -2 - 10 4 1/s.

36 MATERIALS SCIENCE↗

Three-dimensional modeling and simulations of single-crystal and bi-crystal titanium for high-strain-rate loading conditions

High purity single crystal titanium (Ti) under shock wave loading is modeled under both one-dimensional and three-dimensional cylindrical conditions. Cylinder sizes of 10 μm and 20 μm radius are both considered in order to assess influence of boundary conditions. A thermodynamically consistent single crystal model for application to shock conditions is presented. The model accounts for the coupled non-linear elastic, dislocation slip, deformation twinning, and structural phase transformation response of the titanium material. Plate impact experiment results using a copper flyer are used to compare against the simulations for crystals oriented in [0001] and [10$\overline1$1] crystallographic directions. The one-dimensional and threedimensional simulations of the two differently oriented single crystals indicate differences between the one-dimensional and three-dimensional representation, especially for the [10$\overline1$1] oriented single crystal. This orientation breaks the relative orientation symmetry between the crystal and cylinder which otherwise exists for the [0001] oriented single crystal. A significant amount of heterogeneity in the field response of the[10$\overline1$1] oriented simulation was demonstrated due to the highly coupled nature of the deformation. A bi-crystal model composed of both the [0001] and [10$\overline1$1] orientations with the boundary between the two along the axis of the cylinder is also considered for a cylinder model size of 10 μm. The results indicate a strong interaction between the two grains that affects the ω phase volume fraction achieved relative to the single crystal calculations.

36 MATERIALS SCIENCE↗

Excellent cycling stability of sodium anode enabled by a stable solid electrolyte interphase formed in ether-based electrolytes

Sodium (Na)-ion batteries have been considered as one of the most promising power sources beyond Li-ion batteries. Although Na metal anode exhibits a high theoretical capacity of 1165 mAh g-1, its application on Na batteries is largely hindered by dendrite growth and low Coulombic efficiency. Herein, we demonstrate that an electrolyte consists of 1 M sodium tetrafluoroborate in Tetraglyme can enable excellent cycling efficiency (99.9 %) of Na metal anode for more than 1000 cycles. This high reversibility of Na anode can be attributed to a stable solid electrolyte interphase formed on Na surface as revealed by cryogenic transmission electron microscopy and X-ray photoelectron spectroscopy. These electrolytes also enabled excellent cycling stability of Na||hard carbon cells and Na||Na2/3Co1/3Mn2/3O2 cells at high rate with very high coulombic efficiencies.

sodium metal, TEGDME, solid electrolyte interphase↗

Ambient-temperature liquid jet targets for high-repetition-rate HED discovery science

High-power lasers can generate energetic particle beams and astrophysically relevant pressure and temperature states in the high-energy-density (HED) regime. Recently-commissioned high-repetition-rate (HRR) laser drivers are capable of producing these conditions at rates exceeding 1 Hz. However, experimental output from these systems is often limited by the difficulty of designing targets that match these repetition rates. To overcome this challenge, we have developed tungsten microfluidic nozzles, which produce a continuously replenishing jet that operates at flow speeds of approximately 10 m/s and can sustain shot frequencies up to 1 kHz. The ambient-temperature planar liquid jets produced by these nozzles can have thicknesses ranging from hundreds of nanometers to tens of micrometers. In this work, we illustrate the operational principle of the microfluidic nozzle and describe its implementation in a vacuum environment. Further, we provide evidence of successful laser-driven ion acceleration using this target and discuss the prospect of optimizing the ion acceleration performance through an in situ jet thickness scan. Future applications for the jet throughout HED science include shock compression and studies of strongly heated nonequilibrium plasmas. When fielded in concert with HRR-compatible laser, diagnostic, and active feedback technology, this target will facilitate advanced automated studies in HRR HED science, including machine learning-based optimization and high-dimensional statistical analysis.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Novel Bremsstrahlung Converter Designs for Ultra High Dose Rate Radiotherapy Systems

Ultra-high dose rates (UHDR) have been shown to improve the therapeutic index in the treatment of cancer using external beam radiotherapy in many preclinical settings by inducing the so-called “FLASH” effect [1]; however, the underlying biological and physical mechanism(s) are still unknown. Recent work has been to expand the energy range of photons used in UHDR studies from keV photons generated in synchrotron to photons less than 8 MeV produced by accelerated electrons undergoing the bremsstrahlung interaction [2]. This work is a part of the FLASH-Experimental X-ray small Animal Conformal Therapy (FLASH-EXACT) project is aimed at producing a preclinical system that induces the FLASH effect with photons >10 MeV.

61 RADIATION PROTECTION AND DOSIMETRY↗

Mechanical characterization of 304L-VAR stainless steel in tension with a full coverage of low, intermediate, and high strain rates

A 304L-VAR stainless steel is mechanically characterized in tension over a full range of strain rates from low, intermediate, to high using a variety of apparatuses. While low- and high-strain-rate tests are conducted with a conventional Instron and a Kolsky tension bar, the tensile tests at intermediate strain rates are conducted with a fast MTS and a Drop-Hopkinson bar. The fast MTS used in this study is able to obtain reliable tensile response at the strain rates up to 150 s -1 , whereas the lower limit for the Drop-Hopkinson bar is 100 s -1 . Combining the fast MTS and the Drop-Hopkinson bar closes the gap within the intermediate strain rate regime. Using these four apparatuses, the tensile stress-strain curves of the 304L-VAR stainless steel are obtained at strain rates on each order of magnitude ranging from 0.0001 to 2580 s -1 . All tensile stress-strain curves exhibit linear elasticity followed by significant work hardening prior to necking. After necking occurrs, the specimen load decreases, and the deformation becomes highly localized until fracture. The tensile stress-strain response of the 304L-VAR stainless steel exhibits strain rate dependence. The flow stress increases with increasing strain rate and is described with a power law. The strain-rate sensitivity is also strain-dependent, possibly due to thermosoftening caused by adiabatic heating at high strain rates. The 304L-VAR stainless steel shows significant ductility. The true strains at the onset of necking and at failure are determined. The results show that the true strains at both onset of necking and failure decrease with increasing strain rate. The true failure strains are approximately 200% at low strain rates but are significantly lower (~100%) at high strain rates. The transition of true failure strain occurs within the intermediate strain rate range between 10 -2 and 10 2 s -1 . A Boltzmann description is used to present the effect of nominal strain rate on true failure strain.

304L-VAR stainless Steel↗

Towards High-Repetition-Rate Fast Neutron Sources Using Novel Enabling Technologies

High-flux, high-repetition-rate neutron sources are of interest in studying neutron-induced damage processes in materials relevant to fusion, ultimately guiding designs for future fusion reactors. Existing and upcoming petawatt laser systems show great potential to fulfill this need. Here, we present a platform for producing laser-driven neutron beams based on a high-repetition-rate cryogenic liquid jet target and an adaptable stacked lithium and beryllium converter. Selected ion and neutron diagnostics enable monitoring of the key parameters of both beams. A first single-shot proof-of-principle experiment successfully implemented the presented platform at the Texas Petawatt Laser facility, achieving efficient generation of a forward-directed neutron beam. This work lays the foundation for future high-repetition-rate experiments towards pulsed, high-flux, fast neutron sources for radiation-induced effect studies relevant for fusion science and applications that require neutron beams with short pulse duration.

47 OTHER INSTRUMENTATION↗

High strain rate nanoindentation testing: Recent advancements, challenges and opportunities

Recent advancements in electronics have renewed the interest in high strain rate nanoindentation testing, resulting in the development of new high strain rate nanoindentation test equipment and test methodologies. Here, in this work, the current state-of-the-art in high strain rate nanoindentation testing is critically reviewed, with focus on three key aspects - the testing equipment's dynamic mechanical and electronic response, test methodology, and post-processing of raw data to obtain hardness and strain rate. The challenges in instrument hardware design and post-test data analysis are discussed, along with optimal strain rate window for accurate high strain rate measurements. Specific focus will be on instrumented high strain rate testing using self-similar indenters at strain rates in excess of 100 s -1 , wherein load and depth of penetration into the sample are both measured or applied.

36 MATERIALS SCIENCE↗

Monolithic Kerr and electro-optic hybrid microcombs

Microresonator-based soliton generation promises chip-scale integration of optical frequency combs for applications spanning from time keeping to frequency synthesis. Access to the soliton repetition rate is a prerequisite for those applications. While miniaturized cavities harness Kerr nonlinearity and enable terahertz soliton repetition rates, such high rates are not amenable to direct electronic detection. Here, we demonstrate hybrid Kerr and electro-optic microcombs using a lithium niobate thin film that exhibits both Kerr and Pockels nonlinearities. By interleaving the high-repetition-rate Kerr soliton comb with the low-repetition-rate electro-optic comb on the same waveguide, wide Kerr soliton mode spacing is divided within a single chip, allowing for direct electronic detection and feedback control of the soliton repetition rate. Our work establishes an integrated approach to electronically access terahertz solitons, paving the way for building chip-scale referenced comb sources.

42 ENGINEERING↗

Validating corrosion models: A comparison of governing equations

Experimental validation of Finite Element Method (FEM) models varying electrochemical governing equations, inclusion of chemical reactions, and time on the resultant damage profile for two galvanic couples is explored. Two anode materials (Magnesium AZ31 and Carbon Steel) in contact with a cathode (Stainless Steel 304 L) were modeled in/exposed to NaCl (1 and 0.1 M respectively for the anode materials) for up to one week. The physics approach, inclusion of chemical reactions, and the boundary conditions required to accurately represent the damage profile in FEM models depended on the galvanic couple materials and, ultimately, the corrosion rate. For high rates of corrosion (i.e., magnesium anode), the Nernst-Planck equation with Electroneutrality was sufficient to describe the damage, while, for low rates of corrosion (i.e., carbon steel anode), the Laplace equation was sufficient. In all cases, the most complete governing equation (Nernst-Planck-Poisson Equation) was not necessary to accurately describe the damage. Precipitation reactions in solution also played a critical role in the predicted damage profile, especially for high corrosion rate systems. Finally, for short time periods (< 6 h), the choice of governing equations does not significantly influence damage profile results. Overall, the choice of physics to reduce error in simulations relies on the boundary conditions, geometry, conductivity of the solution, electrochemical potential differences, and time of exposure. The above results are discussed with regard to accuracy and computational savings.

Carbon steel↗

Optimizing the sensitivity of high repetition rate broadband transient optical spectroscopy with modified shot-to-shot detection

A major limitation of transient optical spectroscopy is that relatively high laser fluences are required to enable broadband, multichannel detection with acceptable signal-to-noise levels. Under typical experimental conditions, many condensed phase and nanoscale materials exhibit fluence-dependent dynamics, including higher order effects such as carrier–carrier annihilation. With the proliferation of commercial laser systems, offering both high repetition rates and high pulse energies, have come new opportunities for high sensitivity pump-probe measurements at low pump fluences. However, experimental considerations needed to fully leverage the statistical advantage of these laser systems have not been fully described. Here, we demonstrate a high repetition rate, broadband transient spectrometer capable of multichannel shot-to-shot detection at 90 kHz. Importantly, we find that several high-speed cameras exhibit a time-domain fixed pattern noise resulting from interleaved analog-to-digital converters, which is particularly detrimental to the conventional “ON/OFF” modulation scheme used in pump-probe spectroscopy. Using a modified modulation and data processing scheme, we achieve a noise level of 10−5 in 4 s for differential transmission, an order of magnitude lower than for commercial 1 kHz transient spectrometers for the same acquisition time. We leverage the high sensitivity of this system to measure the differential transmission of monolayer graphene at low pump fluence. We show that signals on the order of 10−6 OD can be measured, enabling a new data acquisition regime for low-dimensional materials.

47 OTHER INSTRUMENTATION↗

A Field-Enhanced Conduction-Cooled Superconducting Cavity for High-Repetition-Rate Ultrafast Electron Bunch Generation

High-repetition-rate sources of bright electron bunches have a wide range of applications. They can directly be employed as probes in electron-scattering setups, or serve as a backbone for the generation of radiation over a broad range of the electromagnetic spectrum. This paper describes the development of a compact sub-Mega-electronvolt (sub-MeV) electron-source setup capable of operating at MHz repetition rates and forming sub-picosecond electron bunches with transverse emittance below 20 nm. The setup relies on a conduction-cooled superconducting single-cell resonator with its geometry altered to enhance the field at the surface of the emitter. The system is designed to accommodate cooling using a 2 W pulse-tube cryogen-free cryocooler operated at 4.2 K. Although we focus on the case of a photoemitted electron bunch, the scheme could be adapted to other emission mechanisms.

43 PARTICLE ACCELERATORS↗

Solenoid actuated driver valve for high repetition rate shock tubes

A high speed, high pressure solenoid actuated valve has been developed for use as a driver section for automated shock tubes. The valve is based on a prior design, and significant improvements in the design of the valve are described in this paper. The new design retains the performance of prior versions of the valve and creates very reproducible reaction conditions in the shock tube, which are illustrated by several thousand experiments. Additionally, the longevity of the valve is improved, failures are reduced, and the maintenance and manufacture of the valve are simplified.

47 OTHER INSTRUMENTATION↗