Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “high photon flux”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Observations of Cygnus X-3 above 50 keV

Cygnus X-3 was observed in the energy range 50-400 keV using a balloon-borne, actively collimated, NaI(Tl) scintillation detector. The observation was made from phase 0.45-0.91 of the 4.8 hour period. The photon number spectrum was well represented by a power law with index -2.2. The flux increased throughout the observation, consistent with a highly asymmetric light curve with a peak near phase 0.9.

Meegan, C. A.↗

Radiation transfer in gamma-ray bursts

We have calculated gamma-ray radiative transport in regions of high-energy density, such as gamma-ray burst source regions, using a discrete ordinate, discrete energy group method. The calculations include two-photon pair production and annihilation, as well as three-photon annihilation. The radiation fields itself acts as an absorbing medium, and the optical depth depends on its intensity, so the problem is intrinsically nonlinear. Spherical divergence produces effective collimation of the flux. At high optical depth the high energy (E is greater than 1 MeV) portion of the emergent spectrum assumes a nearly universal form. An approximate limit is derived for the high-energy flux from a gamma-ray burst source region of given size, and the implications of this limit for the distance to the 1979 March 5 event are briefly discussed. We discuss more generally the problem of very luminous bursts, and implications of Galactic halo distances for flare models.

Carrigan, B. J.↗

High precision real-time insertion device and monochromator synchronization at NSLS-II

We report that insertion devices have become the dominant photon source at synchrotron and free electron laser light source facilities the world over. Undulators, characterized by their small deflection parameter, exhibit a high degree of constructive interference in photon production from high energy charged particle beams leading to very high photon rates at specific harmonics of the fundamental frequency with relatively narrow spectral widths. Spectroscopic measurements of interest typically span several of these harmonic widths, which requires precision adjustment of an undulator’s magnetic gap to maintain peak flux within the much narrower bandwidth of a beamline monochromator at the desired energy. High precision insertion device controls are developed at NSLS-II including real-time linked control of monochromator hardware allowing for fast, high precision, hardware triggered, spectroscopic measurements. Furthermore, this fast fly scan method is described, compared statistically for self consistency, and shown to be far superior in both efficiency and accuracy as compared to standard step scan measurements.

36 MATERIALS SCIENCE↗

Study of perovskite CsPbBr 3 detector polarization and its mitigation with ultrahigh x-ray flux

High-flux capable semiconductor x-ray detectors are essential in various applications, but the detrimental effects of detector polarization limit their use in many cases. Here, for this work, we studied the polarization of perovskite CsPbBr 3 semiconductor detectors using ultrahigh flux synchrotron x rays (10 6 –10 12 photons s –1 mm –2 at 58.61 keV). The CsPbBr 3 detectors did not show immediate polarization prominently until a flux higher than 10 10 photons s –1 mm –2 . Using the pump-and-probe technique, we visualized the spatial and temporal effects of polarization. The polarized region, represented by reduced photocurrent, extended beyond the area under direct irradiation, and the reduced photocurrent persisted after potential de-polarization treatments. We found that stronger applied electric fields and fewer carrier traps can mitigate polarization, represented by less photocurrent deficit. By examining the detectors’ current response under controlled ambient light, low, and high-flux x rays, we studied the trap filling and release behavior of CsPbBr 3 . We discovered that the polarization is caused by partial detector damage due to deep defects generated by ultrahigh flux x-ray irradiation. Our work provides insight into CsPbBr 3 polarization under extremely intense x-ray radiation and shows that reducing crystal defects and increasing detector bias voltage are effective solutions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

FMX – the Frontier Microfocusing Macromolecular Crystallography Beamline at the National Synchrotron Light Source II

Two new macromolecular crystallography (MX) beamlines at the National Synchrotron Light Source II, FMX and AMX, opened for general user operation in February 2017 [Schneider et al. (2013). J. Phys. Conf. Ser. 425 , 012003; Fuchs et al. (2014). J. Phys. Conf. Ser. 493 , 012021; Fuchs et al. (2016). AIP Conf. Proc. SRI2015 , 1741 , 030006]. FMX, the micro-focusing Frontier MX beamline in sector 17-ID-2 at NSLS-II, covers a 5–30 keV photon energy range and delivers a flux of 4.0 × 10 12 photons s −1 at 1 Å into a 1 µm × 1.5 µm to 10 µm × 10 µm (V × H) variable focus, expected to reach 5 × 10 12 photons s −1 at final storage-ring current. This flux density surpasses most MX beamlines by nearly two orders of magnitude. The high brightness and microbeam capability of FMX are focused on solving difficult crystallographic challenges. The beamline's flexible design supports a wide range of structure determination methods – serial crystallography on micrometre-sized crystals, raster optimization of diffraction from inhomogeneous crystals, high-resolution data collection from large-unit-cell crystals, room-temperature data collection for crystals that are difficult to freeze and for studying conformational dynamics, and fully automated data collection for sample-screening and ligand-binding studies. FMX's high dose rate reduces data collection times for applications like serial crystallography to minutes rather than hours. With associated sample lifetimes as short as a few milliseconds, new rapid sample-delivery methods have been implemented, such as an ultra-high-speed high-precision piezo scanner goniometer [Gao et al. (2018). J. Synchrotron Rad. 25 , 1362–1370], new microcrystal-optimized micromesh well sample holders [Guo et al. (2018). IUCrJ , 5 , 238–246] and highly viscous media injectors [Weierstall et al. (2014). Nat. Commun. 5 , 3309]. The new beamline pushes the frontier of synchrotron crystallography and enables users to determine structures from difficult-to-crystallize targets like membrane proteins, using previously intractable crystals of a few micrometres in size, and to obtain quality structures from irregular larger crystals.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ultraviolet variability of NGC 5548 - Dynamics of the continuum production region and geometry of the broad-line region

Data from the 1989-1990 IUE monitoring of the Seyfert galaxy NGC 5548 are used here to analyze the continuum variability properties of the galaxy and to derive the structure or its emission-line region. The mean shape of the UV continuum is well fit by an accretion disk model with a given black hole mass and an additional component required to reproduce the observed soft X-ray flux. The continuum fluctuation power spectrum is very steep, with most of the variance coming from about 1 yr time scales. The entire optical/UV continuum rises and falls almost simultaneously, so that the logarithmic slope of the power spectrum is nearly the same for all bands, but the flux at higher photon frequencies varies with larger amplitude. The emission-line material around the nucleus may best be described by a highly ionized inner zone of high and nearly constant pressure that stretches about 4-14 light-days from the center and an outer, more weakly ionized zone of considerably lower ionization at least 20-30 light-days out.

Krolik, J. H.↗

Polycapillary X-Ray Optics for X-Ray Astronomy

High-energy x-ray spectrometry from astronomical sources is difficult due to low flux rates and high background. Polycapillary x-ray optics can be used to increase the signal-to-noise ratio by focusing photons onto a small energy dispersive detector. Two optics, both designed for x-ray astronomy, have been built and tested as collimating optics with a microfocus x-ray source for x-ray energies up to 70 keV and as focusing optics with parallel x-rays up to 50 keV. Results from these tests show that polycapillary x-ray optics have transmission efficiencies ranging from 5% to 40% and signal gains ranging from 5 to over 100 for energies up to 50 keV. Furthermore the results show that these optics have potential for use up to 100 keV. The experimental results as well as simulations for the measured and for optimized optics will be discussed.

Russell, C. H.↗

Comparison of Nitrogen Incorporation in Tholins Produced by FUV Irradiation and Spark Discharge

The discovery of very heavy ions (Coates et al., 2007) in Titan's thermosphere has dramatically altered our understanding of the processes involved in the formation of the complex organic aerosols that comprise Titan's characteristic haze. Before Cassini's arrival, it was believed that aerosol production began in the stratosphere where the chemical processes were predominantly initiated by FUV radiation. This understanding guided the design of Titan atmosphere simulation experiments. However, the energy environment of the thermosphere is significantly different than the stratosphere; in particular there is a greater flux of EUV photons and energetic particles available to initiate chemical reactions, including the destruction of N2. in the upper atmosphere. Using a High Resolution Time-of-Flight Aerosol Mass Spectrometer (HR-ToF-AMS), we have obtained in situ composition measurements of aerosol particles (so'called "tholins") produced in CH4/N2 gas mixtures subjected to either FUV radiation (deuterium lamp, 115-400 nm) (Trainer et al., 2012) or a spark discharge. A comparison of the composition of tholins produced using the two different energy sources will be presented, in particular with regard to the variation in nitrogen content of the two types of tholin. Titan's aerosols are known to contain significant amounts of nitrogen (Israel et al., 2005) and therefore understanding the role of nitrogen in the aerosol chemistry is important to further our knowledge of the formation and evolution of aerosols in Titan's atmosphere.

Horst, S. M.↗

High energy neutrinos from primary cosmic rays accelerated in the cores of active galaxies

The spectra and high-energy neutrino fluxes are calculated from photomeson production in active galactic nuclei (AGN) such as quasars and Seyfert galaxies using recent UV and X-ray observations to define the photon fields and an accretion-disk shock-acceleration model for producing ultrahigh-energy cosmic rays in the AGN. Collectively AGN should produce the dominant isotropic neutrino background between 10 exp 4 and 10 exp 10 GeV. Measurement of this background could be critical in determining the energy-generation mechanism, evolution, and distribution of AGN. High-energy background spectra and spectra from bright AGN such as NGC4151 and 3C273 are predicted which should be observable with present detectors. High energy AGN nus should produce a sphere of stellar disruption around their cores which could explain their observed broad-line emission regions.

Stecker, F. W.↗

Distinct Kinetic Signatures of Photodesorption from Metal Nanoparticles

Visible photon fluxes can influence the rate and selectivity of heterogeneously catalyzed reactions on metal nanoparticle surfaces. Models describing the influence of photon fluxes have typically introduced photon flux dependent apparent thermal kinetic parameters (reaction orders, activation energies, binding energies, etc.). This has relied on empirical fitting of reaction rate data, making mechanistic interpretations of how photon fluxes influence elementary step rates challenging and inconsistent with fundamental descriptions of photochemistry on metal surfaces developed from surface science studies. Using the CO adsorption–desorption quasi-equilibrium reaction on Pt/Al 2 O 3 catalysts as a model system, we measured steady state adsorbed CO (CO*) coverages under isothermal and isobaric (1 mbar CO) conditions as a function of temperature (473–573 K) and of 440 nm photon flux ((0.1–5.2) × 10 3 # hv Pt site –1 s –1 ) using in situ IR spectroscopy. Steady state CO* coverage on Pt was photon flux dependent with increasing photon flux causing decreasing coverage, consistent with photons driving CO* desorption rates faster than thermal CO* desorption rates. However, photon flux dependent CO* coverages were essentially temperature independent, inconsistent with models that describe photon effects using perturbations to apparent thermal kinetic parameters. Instead, 120 steady state CO* coverages as a function of temperature and photon flux are quantitatively described by a kinetic model in which the overall desorption rate is a summation of independent thermal and photon induced CO* desorption rates. Site-resolved analysis reveals distinct kinetic parameters for photon driven desorption of CO* from well-coordinated, under-coordinated, and highly under-coordinated Pt sites, with temperature-dependent apparent quantum efficiencies (AQE) consistent with temperature dependence of vibrational quanta distribution of adsorbed CO. The rigorous kinetic rate laws for independent photon and thermal driven pathways allow for predictive modeling of the influence of photon fluxes on the rates of CO* desorption under catalytic conditions. Further, the analysis provides evidence that steady state continuous wave photon fluxes can drive desorption/adsorption reactions on metal surfaces out of thermal equilibrium, reconciling surface science observations of molecular photodesorption with applied catalysis. The work establishes a general kinetic framework to be considered for photon driven processes on metals, and defines catalyst, reaction, and photon flux characteristic design principles for breaking Sabatier limitations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spectroscopic Demarcation of Emergent Photons and Spinons in a Dipolar-Octupolar Quantum Spin Liquid

The identification of fractionalized excitations in quantum spin liquids (QSLs) remains a central challenge in condensed matter physics. In dipolar-octupolar (DO) pyrochlores, such as Ce 2⁢ Zr 2 ⁢O 7 , the candidate 𝜋-flux quantum spin ice (QSI) state is predicted to host both gapless emergent photons and a continuum of spinons. However, resolving these modes at zero field is complicated by their spectral overlap and the presence of nonmagnetic scattering near zero energy. Here, in this study, we report neutron scattering experiments on Ce 2 ⁢Zr 2 ⁢O 7 under a magnetic field along the [1, 1, 1] direction. In contrast to previous unpolarized studies at zero field that relied on high-temperature subtraction, we use a same-temperature high-field subtraction protocol to isolate the photon and spinon modes. Leveraging the selective coupling of the magnetic field to the dipolar degrees of freedom, we demonstrate the spectroscopic demarcation of these excitations. We observe that weak fields (≈ 0.15 T) suppress the low-energy photon weight while leaving the high-energy spinon continuum robust, albeit hardened. Our results, supported by gauge mean-field theory and exact diagonalization calculations, provide strong evidence for the 𝜋-flux QSI state and introduce a powerful field-tuning protocol for investigating DO-QSLs.

Gao, Bin [Rice University, Houston, TX (United Sta↗

Low-temperature deposition of low resistivity ZnSe films by reactive sputtering

The use of reactive dc magnetron cosputtering of Zn and the dopant In in an H2Se/Ar gaseous mixture is described. It is observed that initial deposition using pure Zn targets produced yellowish transparent ZnSe films on glass with a film resistivity of 10 to the 8th ohms cm and deposition using a Zn target doped with a fixed 1 percent of In produced ZnSe films with resistivities of about 10,000 ohms cm. The improvement of film conductivity by optimizing the In content in the ZnSe films is discussed; the ZnSe resistivity dependence on In flux is studied. Optical absorption/transmission measurements reveal a photon energy band gap of 2.65 eV at room temperature and X-ray diffraction show highly oriented polycrystalline films on glass with the c axis parallel to the plane of the film. Compositional analysis was performed and the Zn/Se ratio is measure as 48.8/49.0 with an In concentration of 1.16 percent. ZnSe films deposited on glass and conducting SnO2-coated glass substrates with a resistance of 20 ohms cm and a substrate temperature of 120 C have been fabricated.

Stirn, R. J.↗

Effects of radiation quality, intensity, and duration on photosynthesis and growth

Differences in radiation quality from the six most common electric lamps have little effect on photosynthetic rate. Radiation quality primarily alters growth because of changes in branching or internode elongation, which change radiation absorption. Growth and yield in wheat appear to be insensitive to radiation quality. Growth and yield in soybeans can be slightly increased under high pressure sodium (HPS) lamps compared to metal halide lamps, in spite of greatly reduced chlorophyll concentrations under HPS lamps. Daily integrated photosynthetic photon flux (mol m(exp -2)d(exp -1)) most directly determines leaf anatomy and growth. Photosynthetic photon flux (PPF) levels of 800 (mu)mol m(exp -2)s(exp -1) are adequate to simulate field daily-integrated PPF levels for both short and long day plants, but plant canopies can benefit from much higher PPF levels.

Bugbee, Bruce↗

Efficient bidirectional quantum frequency conversion between telecom and visible bands using adaptively phase-matched III-V nanophotonic waveguides

Quantum frequency conversion (QFC) is essential for interfacing quantum systems operating at different wavelengths and for realizing scalable quantum networks. Despite extensive progress, achieving QFC with simultaneous high efficiency, low pump power, minimal noise, broad bandwidth, and pump-wavelength flexibility remains challenging. Here, we demonstrate efficient, low-noise, and bidirectional QFC between the telecom (1550-nm) and visible (780-nm) bands using unpoled indium gallium phosphide (InGaP) χ (2) nanophotonic waveguides, eliminating the need for a long-wavelength pump. Leveraging the large nonlinear susceptibility of InGaP together with adaptive phase-matching control, we obtain 27% (55%) internal efficiency in a 6-mm (2.5-mm)-long waveguide with a low pump power of 20 mW (50 mW) and a noise flux spectral density of 10 −4 counts per second per hertz at signal–pump detuning of 20 nm. These results mark a significant advance in integrated nonlinear photonics for high-performance QFC, facilitating the development of versatile and scalable quantum networks.

Hu, Jierui [Univ. of Illinois at Urbana-Champaign,↗

HEAO 1 observations of high-energy X-rays from 3C273

The first detection of high energy (13 to 120 keV) X rays from the quasar 3C273, made by the HEAO 1 satellite, is reported. Observations were made with the 13 to 180 keV slat collimated detectors of the high energy X-ray and low energy gamma-ray (A4) experiment during December 1977-January 1978 and June-July 1978. Results are consistent with the previously observed X-ray flux variability on a scale of months. Photon count rates are presented for each of five energy bands and count rate and photon spectra for the June through July 1978 observations are derived. A comparison of the data obtained with that at lower X-ray energies and higher gamma-ray energies indicates that there is an overall spectral steepening from low to high energies and a possible break near 20 keV, which may be due to the gamma rays originating from a different region than that of the X rays.

Primini, F. A.↗

Solar Ultraviolet Spectral Irradiance Monitor (SUSIM)

The solar ultraviolet spectral irradiance monitor (SUSIM) measures the ultraviolet flux from the entire Sun with high absolute accuracy over the wavelength range 120 to 400 nm with a resolution of 0.1 nm. SUSIM consists of two identical double dispersion scanning spectrometers with 5 photodiodes, 2 photon counters, and a deuterium lamp calibration source, all sealed in a canister pressurized to 1.1 atmosphere of argon. One spectrometer is used almost continuously during sunlight, the other is used once per day as a calibration check. The observations will yield improved absolute measurements of the ultraviolet solar fluxes, provide an accurate reference for studies of variability of the solar fluxes on the time scales of the solar cycle and longer, and measure shorter term changes as well. These measurements complement the active cavity radiometer (ACR) measurements of the total solar irradiance. The data will be used to study the physical behavior of the Sun and the Earth's atmosphere, weather, and climate.

Moore, R. L.↗

Solar Ultraviolet Spectral Irradiance Monitor (SUSIM)

The solar ultraviolet spectral irradiance monitor (SUSIM) measures the ultraviolet flux from the entire Sun with high absolute accuracy over the wavelength range 120 to 400 nm with a resolution of 0.1 nm. SUSIM consists of two identical double dispersion scanning spectrometers with 5 photodiodes, 2 photon counters, and a deuterium lamp calibration source, all sealed in a canister pressurized to 1.1 atmosphere of argon. One spectrometer is used almost continuously during sunlight, the other is used once per day as a calibration check. The observations will yield improved absolute measurements of the ultraviolet solar fluxes, provide an accurate reference for studies of variability of the solar fluxes on the time scales of the solar cycle and longer, and measure shorter term changes as well. These measurements complement the ACR measurements of the total solar irradiance. The data will be used to study the physical behavior of the Sun and the Earth's atmosphere, weather, and climate.

Moore, R.↗

Model atmospheres and radiation of magnetic neutron stars: Anisotropic thermal emission

We investigate the anisotropy of the thermal radiation emitted by a surface element of a neutron star atmosphere (e.g., by a polar cap of a radio pulsar). Angular dependences of the partial fluxes at various photon energies, and spectra at various angles are obtained for different values of the effective temperature T(sub eff) and magnetic field strength B, and for different directions of the magnetic field. It is shown that the local radiation of the magnetized neutron star atmospheres is highly anisotropic, with the maximum flux emitted in the magnetic field direction. At high B the angular dependences in the soft X-ray range have two maxima, a high narrow peak along B and a lower and broader maximum at intermediate angles. The radiation is strongly polarized, the modulation of the degree of polarization due to the rotation of the neurtron star may be much higher than that for the radiative flux. The results obtained are compared with recent ROSAT observations of the thermal-like radiation from the radio pulsars PSR 1929+10 and PSR J0437-4715.

Pavlov, G. G.↗