Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “high performance building”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Smart building management vs. intuitive human control—Lessons learnt from an office building in Hungary

We report that smart building management and control are adopted nowadays to achieve zero-net energy use in buildings. However, without considering the human dimension, technologies alone do not necessarily guarantee high performance in buildings. An office building was designed and built according to state-of-the-art design and energy management principles in 2008. Despite the expectations of high performance, the owner was facing high utility bills and low user comfort in the building located in Budapest, Hungary. The objective of the project was to evaluate the energy performance and comfort indices of the building, to identify the causes of malfunction and to elaborate a comprehensive energy concept. Firstly, current building conditions and operation parameters were evaluated. Our investigation found that the state-of-the-art building management system was in good conditions but it was operated by building operators and occupants who are not aware of the building management practice. The energy consumption patterns of the building were simulated with energy modelling software. The baseline model was calibrated to annual measured energy consumption, using actual occupant behaviour and presence, based on results of self-reported surveys, occupancy sensors and fan-coil usage data. Realistic occupant behaviour models can capture diversity of occupant behaviour and better represent the real energy use of the building. This way our findings and the effect of our proposed improvements could be more reliable. As part of our final comprehensive energy concept, we proposed intervention measures that would increase indoor thermal comfort and decrease energy consumption of the building. A parametric study was carried out to evaluate and quantify energy, comfort and return on investment of each measure. It was found that in the best case the building could save 23% of annual energy use. Lastly, future work includes the follow-up of: occupant reactions to intervention measures, the realized energy savings, the measurement of occupant satisfaction and behavioural changes.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Raising the Rent Premium: Moving Green Building Research Beyond Certifications and Rent

Advocates for high-performing, energy efficient buildings understand the hurdles to proving the business case to spur development and investment decisions among commercial real estate owners and investors. Although there is significant evidence that green buildings exhibit increased financial performance via decreased operating expenses and non-energy benefits such as workplace comfort and employee productivity, green building practitioners still face an uphill battle when asked to prove the profits, most frequently pointing to rent premium as an indicator to attract investment. This paper documents a recently conducted literature review commissioned by the US Department of Energy (DOE) of 39 peer-reviewed and published academic papers pertaining to green or energy-related building attributes and financial performance. The review (first published here) indicated that 27 papers found a positive correlation between green building certifications and rents. If this is the case, then why are green building development and energy efficiency retrofits not the norm for the industry? This paper first synthesizes the recent literature review to illustrate that the existing body of empirical evidence supports green building investment. Next, it describes a workshop of leading academics in real estate sustainability and finance who met in late 2017 to discuss gaps in green building research and assess data challenges in their fields. Insights synthesized the workshop were used to drive new DOE led research that can provide value and understanding to investors and builders of high performing buildings. Finally, the paper offers insights into why the market is not properly pricing building efficiency, with factors ranging from improper mitigation of risks associated with energy and lack of transparency and responsibility felt by building end users, and what further steps are needed to transform green building investment practices in the commercial real estate industry.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

para -Azaquinodimethane: A Compact Quinodimethane Variant as an Ambient Stable Building Block for High-Performance Low Band Gap Polymers

Quinoidal structures incorporating expanded para-quinodimethane (p-QM) units have garnered great interest as functional organic electronic, optical, and magnetic materials. The direct use of the compact p-QM unit as an electronic building block, however, has been inhibited by the high reactivity conveyed by its biradical character. Herein, we introduce a stable p-QM variant, namely p-azaquinodimethane (p-AQM), that incorporates nitrogen atoms in the central ring and alkoxy substituents on the periphery to increase the stability of the quinoidal structure. The succinct synthesis from readily available precursors leads to regio- and stereospecific p-AQMs that can be readily integrated into the backbone of conjugated polymers. The quinoidal character of the p-AQM unit endows the resulting polymers with narrow band gaps and high carrier transport mobilities. The study of a series of copolymers employing different numbers of thiophene units revealed an unconventional trend in band gaps, which is distinct from the widely adopted donor-acceptor approach to tuning the band gaps of conjugated polymers. Theoretical calculations have shed light on the nature of this trend, which may provide a unique class of conjugated polymers with promising optical and electronic properties.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Charge carrier nonadiabatic dynamics in non-metal doped graphitic carbon nitride

Graphitic carbon nitride (GCN) has attracted significant attention due to its excellent performance in photocatalytic applications. Non-metal doping of GCN has been widely used to improve the efficiency of the material as a photocatalyst. Using a combination of time-domain density functional theory with nonadiabatic molecular dynamics, we study the charge carrier dynamics in oxygen and boron doped GCN systems. The reported simulations provide a detailed time-domain mechanistic description of the charge separation and recombination processes that are of fundamental importance while evaluating the photovoltaic and photocatalytic performance of the material. The appearance of smaller energy gaps due to the presence of dopant states improves the visible light absorption range of the doped systems. At the same time, the nonradiative lifetimes are shortened in the doped systems as compared to the pristine GCN. In the case of boron doped at a carbon (B–C–GCN), the charge recombination time is very long as compared to the other two doped systems owing to the smaller electron–phonon coupling strength between the valence band maximum and the trap state. The results suggest B–C–GCN as the most suitable candidate among three doped systems studied in this work for applications in photocatalysis. Finally, this work sheds light into the influence of dopants on quantum dynamics processes that govern GCN performance and, thus, guides toward building high-performance devices in photocatalysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Accelerating the Adoption of the Solid Panel Structural System

This report, "Accelerating the Adoption of the Solid Panel Structural System", explores the structural properties, capabilities, and applications for an innovative “studless” building system that uses a plate-like approach and “Perfect Wall” principles for an efficient, durable, and robust wall system. A comprehensive testing regime was completed to fully characterize the structural behavior of the Solid Panel Structural system. These results were used to develop an engineering guide that can be used by architects and engineers for design and code approval.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

LCC-based framework for building envelope and structure co-design considering energy efficiency and natural hazard performance

Herein, this paper presents a life-cycle cost (LCC) informed co-design framework for building structures and envelope systems, holistically considering the influences of energy and natural hazard performance. The proposed method is consisted of a two-stage design and decision-making process, aiming to provide a quantitative guideline for building's structural and envelope co-design based on the its geographic locations. First, the building's structural configuration and envelope type are selected based on the life cycle cost. Then, the long-term cost effectiveness of various energy-saving building envelope options (e.g., high-performance glazing and insulation) is evaluated to refine the envelope design. The proposed co-design framework was demonstrated through the case study of a medium-size office building archetype in three locations with distinct climate conditions and seismic activities (i.e., Los Angeles, Memphis, and Boston). The results highlighted the interplay between building's structural (seismic) performance and the cost-effectiveness of energy-saving design options – e.g., for buildings located in high-seismic regions, seismic enhancing designs greatly reduce the paybak period of high performance building envelope by reducing the seismic loss; whereas for buildings located in regions with cold climate and low seismic risk such as Boston, spatial frame with high insulation building envelope shows the lowest LCC.

42 ENGINEERING↗

SAME4HPC: A Promising Approach in Building a Scalable and Mobile Environment for High-Performance Computing

In this paper, an architecture for building Scalable And Mobile Environment For High-Performance Computing with spatial capabilities called SAME4HPC is described using cutting-edge technologies and standards such as Node.js, HTML5, ECMAScript 6, and PostgreSQL 9.4. Mobile devices are increasingly becoming powerful enough to run high-performance apps. At the same time, there exist a significant number of low-end and older devices that rely heavily on the server or the cloud infrastructure to do the heavy lifting. Our architecture aims to support both of these types of devices to provide high-performance and rich user experience. A cloud infrastructure consisting of OpenStack with Ubuntu, GeoServer, and high-performance JavaScript frameworks are some of the key open-source and industry standard practices that has been adopted in this architecture.

Karthik, Rajasekar↗

A novel lung-inspired 3D-printed desiccant-coated heat exchanger for high-performance humidity management in buildings

Offering an independent humidity management method for buildings, desiccant-coated heat exchangers (DCHXs) are deemed a promising approach to improve the overall energy efficiency of air conditioning (AC) systems. State-of-the-art DCHXs, however, are bound with conventional HX topologies either providing limited desiccant-air interfacial areas or introducing excessive pressure drop penalties. In this paper a novel 3D-printed DCHX concept inspired by the bronchi arrangement of a human lung is introduced to address the shortcomings inherent in existing DCHX designs. The proposed lung-inspired DCHX utilizes two intertwined bicontinuous flow networks enabling highly efficient heat and mass transfer characteristics for augmented adsorption and regeneration processes at low pressure drop penalties. While the first network evenly distributes an incoming air stream through the entire volume of the lung-inspired DCHX, the second network volumetrically splits a cooling water stream within and through the first network. Effects of various parameters including air flow rate, outdoor air humidity ratio, and regeneration temperature on dehumidification performance and energy efficiency of the proposed lung-inspired DCHX were investigated. Experimental results indicated the proposed lung-inspired 3D-printed DCHX outperforms existing DCHX systems by demonstrating an excellent balance between a high volumetric adsorption rate and a low pressure drop penalty. The volumetric adsorption rate of the proposed lung-inspired DCHX technology is 54.8 g/m 3 -s, a more than two-fold improvement compared with state-of-the-art DCHX systems. Additionally, the lung-inspired DCHX offers high thermal energy efficiency of 56% at a low regeneration temperature of 40 °C. Therefore, the proposed lung-inspired 3D-printed DCHX offers a new solid-desiccant-based air dehumidification pathway for next-generation high-performance AC systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Guiding Principles for Sustainable Existing Buildings: Radiochemical Processing Laboratory

In 2006, the United States (U.S.) Department of Energy (DOE) signed the Federal Leadership in High Performance and Sustainable Buildings Memorandum of Understanding (MOU), along with 21 other agencies. Pacific Northwest National Laboratory (PNNL) is exceeding this requirement and, currently, about 25 percent of its buildings are High Performance and Sustainable Buildings. The pages that follow document the Guiding Principles conformance effort for the Radiochemical Processing Laboratory (RPL) at PNNL. The RPL effort is part of continued progress toward a building inventory that is 100 percent compliant with the Guiding Principles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-Performance Integrated Window and Façade Solutions for California

The researchers developed a new generation of high-performance façade systems and supporting design and management tools to support industry in meeting California’s greenhouse gas reduction targets, reduce energy consumption, and enable an adaptable response to minimize real-time demands on the electricity grid. The project resulted in five outcomes: (1) The research team developed an R-5, 1-inch thick, triplepane, insulating glass unit with a novel low-conductance aluminum frame. This technology can help significantly reduce residential cooling and heating loads, particularly during the evening. (2) The team developed a prototype of a windowintegrated local ventilation and energy recovery device that provides clean, dry fresh air through the façade with minimal energy requirements. (3) A daylight-redirecting louver system was prototyped to redirect sunlight 15–40 feet from the window. Simulations estimated that lighting energy use could be reduced by 35–54 percent without glare. (4) A control system incorporating physics-based equations and a mathematical solver was prototyped and field tested to demonstrate feasibility. Simulations estimated that total electricity costs could be reduced by 9-28 percent on sunny summer days through adaptive control of operable shading and daylighting components and the thermostat compared to state-of-the-art automatic façade controls in commercial building perimeter zones. (5) Supporting models and tools needed by industry for technology R&D and market transformation activities were validated. Attaining California’s clean energy goals require making a fundamental shift from today’s ad-hoc assemblages of static components to turnkey, intelligent, responsive, integrated building façade systems. These systems offered significant reductions in energy use, peak demand, and operating cost in California.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Tailored Assemblies of Rod-Coil Poly(3-hexylthiophene)-b-Polystyrene Diblock Copolymers: Adaptable Building Blocks for High-Performance Organic Field-Effect Transistors

The self-assembly process and resulting structure of a series of conductive diblock copolymer thin films of Poly(3-hexylthiophene)-b-Polystyrene (P3HT-b-PS) have been studied by TEM, SAED, GIXD and AFM and additionally by first principles modeling and simulation. By varying the molecular weight of the P3HT segment, these block copolymers undergo microphase separation and self-assemble into nanostructured sphere, lamellae, nanofiber, and nanoribbon in the films. Within the diblock copolymer thin film, the convalently bonded PS blocks segregated to form amorphous domains, however, the conductive P3HT blocks were crystalline, exhibiting highly-ordered molecular packing with their alkyl side chains aligned along to the normal to the substrate and the - stacking direction of the thiophene rings aligned parallel to the substrate. The conductive P3HY block copolymers exhibited significant improvements in organic feild-effect transistor (OFET) performance and environmental stability as compared to P3HT homopolymers, with up to a factor of two increase in measured moblity (0.08 cm2/Vs ) for the P4 (85 wt% P3HT). Overall, this work demonstrates that the high degree of molecular order induced by bock copolymer phase separation can improve the transport properties and stability of conductive polymer critical for high-performance OFET s.

36 MATERIALS SCIENCE↗