Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Radiative Heating in MSL Entry: Comparison of Flight Heating Discrepancy to Ground Test and Predictive Models

During the recent entry of the Mars Science Laboratory (MSL), the heat shield was equipped with thermocouple stacks to measure in-depth heating of the thermal protection system (TPS). When only convective heating was considered, the derived heat flux from gauges in the stagnation region was found to be underpredicted by as much as 17 W/sq cm, which is significant compared to the peak heating of 32 W/sq cm. In order to quantify the contribution of radiative heating phenomena to the discrepancy, ground tests and predictive simulations that replicated the MSL entry trajectory were performed. An analysis is carried through to assess the quality of the radiation model and the impact to stagnation line heating. The impact is shown to be significant, but does not fully explain the heating discrepancy.

MSL↗

The Role of Local Heating in the 2015 Indian Heat Wave

India faced a major heat wave during the summer of 2015. Temperature anomalies peaked in the dry period before the onset of the summer monsoon, suggesting that local land-atmosphere feedbacks involving desiccated soils and vegetation might have played a role in driving the heat extreme. Upon examination of in situ data, reanalysis, satellite observations, and land surface models, we find that the heat wave included two distinct peaks: one in late May, and a second in early June. During the first peak we find that clear skies led to a positive net radiation anomaly at the surface, but there is no significant sensible heat flux anomaly within the core of the heat wave affected region. By the time of the second peak, however, soil moisture had dropped to anomalously low levels in the core heat wave region, net surface radiation was anomalously high, and a significant positive sensible heat flux anomaly developed. This led to a substantial local forcing on air temperature that contributed to the intensity of the event. The analysis indicates that the highly agricultural landscape of North and Central India can reinforce heat extremes under dry conditions.

Debjani Ghatak↗

SEASONAL PERFORMANCE SIMULATION OF A GAS-FIRED CHEMISORPTION HEAT PUMP FOR RESIDENTIAL HEATING IN COLD CLIMATE

The gas-fired chemisorption heat pump (CSHP) is a promising technology for high-efficiency cold-climate residential heating. The CSHP utilizes the heat of reversible chemical reactions between sorbent and refrigerant to extract heat from cold ambient and supply high-temperature heat to the indoors. The efficiency of CSHP depends on the ambient and heat rejection temperatures. This study evaluates the seasonal performance of a CSHP by first develop a dynamic system model to generate a performance map for various ambient and heat-supply temperatures; then the bin method is used to evaluate the CSHP seasonal performance in two cold-climate locations for space and water heating.

Yang, Zhiyao↗

Modelling and Simulation of a Thermoelectric Heat Pump with Micro-Channel Heat Transfer

Thermoelectric heat pumps (TEHPs) have advantages of modularity and simple design for heating and cooling in some applications. Models of thermoelectric (TE) heat pumps are widely studied. Nevertheless, most existing modeling work focuses on the TE material or air-sourced TE modules. TEHP modeling, especially the relationship between modules and heat exchangers, has not been comprehensively conducted. This work presents a water-to-water TEHP modeling framework that combines Goldsmid’s approach for TE material performance, Gnielinski’s correlation for convective heat transfer, and thermal balance theory for heat exchange networks. This combined framework provides an accurate theoretical analysis of the water-to-water TEHP system. Subsequently, the framework was used to empirically determine TE material properties (electric resistivity, thermal conductivity, and Seebeck coefficient) that minimize modeling errors versus experimentally observed values from the literature. Finally, an additional set of experimental TEHP data was used to validate the model, all with relative absolute deviations of approximately 10% when predicting heating capacity and 10%–20% when forecasting cooling capacity at a 30 K temperature lift. For future work, people can further develop models of TEHPs with an air-based heat sink on one side and water channels on the other side.

Wan, Hanlong↗

Compliant heat exchangers, heat pipes and methods for making same

A method for fabricating heat exchangers using additive manufacturing technologies. Additive manufacturing enables the manufacture of heat exchangers with complex geometries and/or with internal and external integral surface features. Additive manufacture also facilitates the manufacture of heat exchangers with regional variations, such as changes in size, shape and surface features. In one embodiment, the present invention provides a heat exchanger with a helicoidal shape that provides axial elastic compliance. In one embodiment, the internal channel of the heat exchanger varies along its length. The internal channel may have a cross-sectional area that increases progressively from one end to the other. In one embodiment, the external shape of the tubular structure may be non-circular to optimize heat transfer with an external heat transfer fluid. In one embodiment, the present invention provides a heat pipe with an internal wicking structure formed as an integral part of the additive manufacturing process.

Lara-Curzio, Edgar↗

Heat Exchangers Circuitry Optimization using Low-GWP Refrigerants in Reversible Heat Pump Applications

Tube-fin heat exchangers (TFHX) are widely used in heat pump applications. Circuitry optimization can improve system performance. Previous optimizations focus on improving component-level performance under a specific operating condition, i.e., the TFHX either works as a condenser or an evaporator. The optimal circuitry obtained under air conditioning (AC) mode cannot guarantee optimal performance when used in heat pump (HP) mode. This study implements a bi-objective formulation to achieve optimal system performance in both AC and HP modes. An integer permutation-based Genetic Algorithm is integrated with Heat Pump Design Model (HPDM) to perform heat pump optimization. Six refrigerants, i.e., R410A, R452B, R454B, R32, D2Y60 and L41a are investigated. Case studies show that optimal heat exchangers yield 2.1%-6.1% EER improvement under AC mode and 1.9%-8.5% COP improvement under HP mode. Use of this design approach can help assure a preferable performance of reversible heat pumps during both cooling and heating mode usage.

Li, Zhenning↗

Metal foam heat exchangers for air and gas cooling and heating applications

Improved heat exchangers according to several embodiments are provided. The heat exchangers provide improved heat transfer for air flow in wet and dry operating conditions, while minimizing pressure drop across the heat exchanger in some applications. According to one embodiment, an improved heat exchanger includes a plurality of metal foam fins between adjacent heat exchange conduits, the heat exchange conduits being arranged parallel to each other to define parallel flow paths between an inlet header and an outlet header. The metal foam fins occupy a cross-flow region between adjacent conduits, the fins having a fixed angular orientation or being rotatable in unison to vary the thermal capacitance of the heat exchanger.

Nawaz, Kashif↗

Field Test and Thermal Performance Comparison of a Novel Underground Thermal Battery with a Single U-tube Borehole Heat Exchanger for Geothermal Heat Pump Application

Geothermal Heat Pumps (GHP) are a proven technology to electrify and decarbonize space heating and cooling by utilizing the thermally consistent underground as a heat sink or source. However, the high drilling costs of conventional borehole heat exchangers (BHEs) associated with GHP systems and subsurface heterogeneity have been two major challenges to their widespread adoption. In this paper, we present results from a field-scale pilot of an Underground Thermal Battery (UTB) as a potential alternative to a conventional BHE. To benchmark the UTB performance, a side-by-side field test was conducted to compare the UTB with a conventional BHE installed at the same site. The UTB was installed in a 7.01-meter-deep borehole having a diameter of 0.9 meter, whereas the conventional BHE (with single U-tube loop) is in a borehole with 36.6-meter depth and 0.15-meter diameter. Both are integrated into a GHP system to meet the thermal energy demands of office space at the Illinois Energy Farm on the University of Illinois Urbana-Champaign campus. The system’s performance is compared in terms of heat transfer rate, outlet temperatures, and contributions to the overall thermal power of the GHP system under varying thermal demands and in different heat pump operation modes: heating only, cooling only, and hybrid (alternative, diurnal heating and cooling). Results to date indicate that the UTB delivers a more consistent response under during a time period of varying thermal demands. Its operational performance is better during short-term with higher thermal demands, while the conventional BHE performs better under continuous, long-term thermal demands.

Pokhrel, Sajjan [ORNL] (ORCID:0000000228523749)↗

Performance Assessment of a Heat Pump Integrated with Thermal Energy Storage in Cooling & Heating Modes

Thermal Energy Storage (TES) systems have demonstrated significant potential to manage the fluctuating nature of energy demand and shifting peak loads. This technology has made significant recent advances, including new research on the integration of TES with residential and commercial Heating, Ventilation, and Air-Conditioning (HVAC) systems. In this paper, we present the use of a novel laboratory assessment framework for a prototype heat pump system integrated with latent heat phase change material-based TES. The assessment framework consists of 22 total test points (11 heating, 11 cooling) using psychrometric conditions from AHRI Standard 210/240 and includes transient conditions to evaluate TES charging and discharging modes. In addition, both continuous mode and cyclic mode were evaluated for charging and discharging to explore the benefits to TES heat transfer from repeated transient operation. The ambient conditions evaluated include heating mode charging at cold-climate heat pump conditions when winter-peaking utilities may most require demand reduction (H4Full conditions, 5°F/-15°C) and cooling mode charging at high ambient temperature that may occur during times of day when excess solar power generation results in low-cost electricity (105°F/40.6°C). The work demonstrates the demand reduction capabilities of integrating TES with HVAC, including up to 44% in cooling mode and 60% in heating mode compared to conventional HVAC equipment without TES.

25 ENERGY STORAGE↗

A novel 3-D pulsating heat pipe module for high heat-flux applications

This study proposed a novel pulsating heat pipes (PHP) for high-flux thermal module. According to the open literature, the maximum value of the heat flux is 23.7 W∙cm –2 handled by PHP, which is far behind industry requirements. Therefore, the present study proposes a novel 3D PHP suitable for high heat-flux applications. The PHP were experimentally tested for different working fluids, including methanol and water. Furthermore, the experiments were performed to analyze the influence of various operating parameters, such as filling ratio (25–60%), heat load (100–800 W), and air flow rate 100–250 cubic feet per minute (CFM). In this work, the results showed that this PHP can sustain a heat flux up to 70 W∙cm –2 with the maximum case temperature under 80 °C, which is approximately three times higher than the available literature. Furthermore, the performance of the PHP module was compared against the commercial module with wicked heat pipe. The PHP exhibited about 7% higher heat dissipation compared to the commercial module. Since the proposed module uses simple copper tubes in its construction over the wicked structure used in commercial module, the novel 3D PHP module provides additional economic and mass production capability.

3D pulsating heat pipe↗

Experimental study of a thermal energy storage-integrated heat pump system for load shifting in space cooling and heating

This study experimentally investigates an all-season thermal energy storage-integrated heat pump (TES-HP) system developed to enhance building energy efficiency and support grid-interactive operation through load shifting in both cooling and heating. A 4-ton commercial rooftop air-source heat pump was modified by integrating a hydronic thermal energy storage (TES) unit containing a phase change material (PCM) with a melting temperature of 22.0 °C. The system employs two reversing valves and three electronic expansion valves to enable six operating modes, including normal, TES charging, and TES discharging in both cooling and heating seasons. A subcooling-controlled electronic expansion valve was implemented to mitigate refrigerant maldistribution caused by unequal internal volumes among the heat exchangers. Compared with a baseline heat pump, the TES-HP reduced power consumption by 30–50% during cooling at an ambient temperature of 40.6 °C, and by up to 60% during heating at −15.0 °C, while maintaining high performance under cold-climate conditions. Additionaly to experimental evaluation, a simplified annualized on-peak analysis was conducted to compare the TES-HP with the baseline system, indicating an on-peak electricity reduction of approximately 876 kWhₑ per unit per year and associated on-peak cost savings under time-of-use pricing. These results demonstrate that the TES-HP effectively decouples HP operation from adverse ambient conditions, improving flexibility, resilience, and energy efficiency. This work advances prior research by experimentally proving the integration of PCM-based TES for a year-round, load-flexible HVAC operation.

42 ENGINEERING↗

Effect of Urban Heat Island and Global Warming Countermeasures on Heat Release and Carbon Dioxide Emissions from a Detached House

Urban air temperature rises induced by the urban heat island (UHIE) effect or by global warming (GW) can be beneficial in winter but detrimental in summer. The SCIENCE-Outdoor model was used to simulate changes to sensible heat release and CO 2 emissions from buildings yielded by four UHIE countermeasures and five GW countermeasures. This model can evaluate the thermal condition of building envelope surfaces, both inside and outside. The results showed that water-consuming UHIE countermeasures such as evaporative space cooling and roof water showering provided positive effects (decreasing sensible heat release and CO 2 emissions related to space conditioning) in summer. Additionally, they had no negative (unwanted cooling) effects in winter since they can be turned off in the heating season. Roof greening can provide the greatest space- conditioning CO 2 emissions reductions among four UHIE countermeasures, and it reduces the amount of heat release slightly in the heating season. Since the effect on reducing carbon dioxide (CO 2 ) emissions by UHIE countermeasures is not very significant, it is desirable to introduce GW countermeasures in order to reduce CO 2 emissions. The significance of this study is that it constructed the new simulation model SCIENCE-Outdoor and applied it to show the influence of countermeasures upon both heat release and CO 2 emissions.

54 ENVIRONMENTAL SCIENCES↗

Minimizing Auxiliary Heat Use for Cold Climate Operation of Air-Source Heat Pumps

This paper investigates the auxiliary heat use for air-source heat pumps (ASHPs) operating in cold climate conditions. Twelve variable-capacity, central ducted ASHPs installed in single-family homes in cold climate regions (eleven in northwest United States and one in Denver suburb) were monitored for an entire winter season to collect data at cold temperatures. The methodology employed airside and power measurements that were taken every five-seconds, to calculate heat pump's capacity, coefficient of performance (COP), and auxiliary heat energy consumption. This paper provides valuable insights into the practical implications of auxiliary heat utilization in centrally ducted ASHPs and suggests opportunities to mitigate the usage of auxiliary heat, improving the overall system efficiency during cold climate operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Minimizing Auxiliary Heat Use for Cold Climate Operation of Air Source Heat Pumps: Preprint

This paper investigates the auxiliary heat use for air-source heat pumps (ASHPs) operating in cold climates. Twelve variable-capacity, central ducted ASHPs installed in single-family homes in cold climate regions (eleven in the northwest United States and one in a Denver suburb) were monitored for an entire winter season to collect data at cold temperatures. The methodology employed airside and power measurements that were taken every five seconds, to calculate the heat pump’s capacity, coefficient of performance (COP), and auxiliary heat energy consumption. This paper provides insights into the practical implications of auxiliary heat utilization in centrally ducted ASHPs and suggests opportunities to mitigate the usage of auxiliary heat, improving overall system efficiency during cold climate operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced absorber heat integration via heat exchange packings

A rate-based model of an absorption column was developed and used to analyze several intercooling strategies utilizing “heat exchange packings.” These packings are capable of removing heat from the column and transferring it to a cooling fluid within the packing. For absorption of CO 2 into aqueous monoethanolamine under industrial conditions, intercooling via heat exchange packings placed along 10–20% of the column could reduce the column height by ~15%. The height of these columns was close to the minimum theoretical value, calculated by numerically optimizing the temperature profile. Effective intercooling could also be achieved by using the cool, rich solvent as the cooling fluid. This reduces the cooling load and facilitates recovery of waste heat. Heat exchange packings could also be used to redistribute heat within the column, reducing the column height with no net cooling load. However, this approach requires larger heat transfer coefficients than have been experimentally observed.

20 FOSSIL-FUELED POWER PLANTS↗

Studies of the influence of heat pipe model and coupling strategy in heat pipe microreactor simulations using Sockeye

This work demonstrates various modeling approaches for thermally coupling heat pipes to a graphite monolithic block in a microreactor context, accounting for the presence of a gap. We show that heat pipe model selection has a significant impact on the transient behavior of a three-dimensional coupled microreactor assembly problem by comparing results obtained using different heat pipe models from the heat pipe code Sockeye. Additionally, we show that the choice of coupling strategy has significant consequences for both accuracy and performance. Furthermore, we found that our heat flux transfer strategy exhibited greater accuracy than our temperature transfer strategy, even when comparing a loose coupling of the heat flux transfer strategy to a tight coupling of the temperature transfer strategy. Although this research uses only theoretical test problems, it provides important insights in modeling thermal fluids phenomena in heat pipe microreactors.

Direwolf↗

Cool rooms for indoor heat resilience: Evaluating affordable cooling strategies in heat-stressed California homes

Extreme heat conditions pose significant indoor survivability challenges for resource-constrained communities, which often lack access to cooling, have poorly insulated homes, and face compounding socioeconomic vulnerabilities. Moreover, concurrent power outages worsen health risks and heat-related illnesses. It is therefore crucial to develop innovative and affordable cooling approaches to protect vulnerable populations. This study assesses the efficacy of “cool rooms”– a designated space within a home equipped with passive and low-power active cooling measures to maintain safe indoor temperatures during extreme heat events and power disruptions. Using a physics-based building energy modeling approach, we evaluate the efficacy of various retrofit packages in maintaining thermal safety within the cool room under recent extreme heat conditions. The results indicate that passive measures can reduce 64% of hours with unmet standard effective temperatures, while the combination of passive and low-power active measures with built-in batteries further cuts this to 86%. Nevertheless, these strategies remain insufficient to maintain indoor thermal safety during extended outages. In contrast, integrating a solar-powered mini-split heat pump, whose technical potential was evaluated in this study, reduces indoor air temperatures below the 28 °C overheating threshold and significantly improves indoor habitability. The localized cool room strategy also offers potential for grid resilience by reducing peak electricity demand by up to 70% compared to whole house cooling during heat waves. The findings can inform the development of actionable heat mitigation plans and retrofit policies for residential communities with relatively low adoption of air conditioning such as warm marine climates.

Cool room↗

Heat pulse propagation and anomalous electron heat transport measurements on the optimized stellarator W7-X

The optimized stellarator Wendelstein 7-X (W7-X) is designed to have an approximately quasi-isodynamic magnetic configuration with reduced neoclassical transport in comparison to a classical stellarator, and turbulent transport is expected to be a significant source of anomalous heat transport across the plasma minor radius. The ion temperature gradient driven mode and the trapped electron mode (TEM) are thought to be responsible for the ion-scale turbulence in W7-X plasmas with volume averaged pressure below 1%. In this work, the electron temperature gradient driven turbulence is shown to be a good candidate for the explanation of the observed electron heat flux, in the inner plasma region where the density gradient is weak (in the outer region, a relatively stronger density gradient would drive additional TEM turbulence). Further, the experimental electron heat transport measured during electron cyclotron resonant heating power and plasma density scans is compared to neoclassical predictions, and the stiffness in the electron heat transport measured during transient transport experiments is presented in three common magnetic configurations of W7-X. In low-(β) plasma discharges, the stiffness in the electron heat flux, quantified by the ratio of the heat pulse to power balance diffusivity, ${\chi }_{\mathrm{e}}^{\mathrm{H}\mathrm{P}}/{\chi }_{\mathrm{e}}^{\mathrm{P}\mathrm{B}}$, is measured to be less than 2, and trend downwards with increasing collisionality.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗