Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heat transfer loop”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Pump, and earth-testable spacecraft capillary heat transport loop using augmentation pump and check valves

A spacecraft includes heat-generating payload equipment, and a heat transport system with a cold plate thermally coupled to the equipment and a capillary-wick evaporator, for evaporating coolant liquid to cool the equipment. The coolant vapor is coupled to a condenser and in a loop back to the evaporator. A heated coolant reservoir is coupled to the loop for pressure control. If the wick is not wetted, heat transfer will not begin or continue. A pair of check valves are coupled in the loop, and the heater is cycled for augmentation pumping of coolant to and from the reservoir. This augmentation pumping, in conjunction with the check valves, wets the wick. The wick liquid storage capacity allows the augmentation pump to provide continuous pulsed liquid flow to assure continuous vapor transport and a continuously operating heat transport system. The check valves are of the ball type to assure maximum reliability. However, any type of check valve can be used, including designs which are preloaded in the closed position. The check valve may use any ball or poppet material which resists corrosion. For optimum performance during testing on Earth, the ball or poppet would have neutral buoyancy or be configured in a closed position when the heat transport system is not operating. The ball may be porous to allow passage of coolant vapor.

Baker, David↗

Miniature Loop Heat Pipe with Multiple Evaporators for Thermal Control of Small Spacecraft

This paper presents an advanced miniature heat transport system for thermal control of small spacecraft. The thermal system consists of a loop heat pipe (LHP) with multiple evaporators and multiple deployable radiators for heat transfer, and variable emittance coatings on the radiators for performance enhancement. Thermoelectric coolers are used to control the loop operating temperature. The thermal system combines the functions of variable conductance heat pipes, thermal switches, thermal diodes, and the state-of-the-art LHPs into a single integrated thermal system. It retains all the performance characteristics of state-of-the-art LHPs and offers additional advantages to enhance the functionality, performance, versatility, and reliability of the system. Steady state and transient analytical models have been developed, and scaling criteria have also been established. A breadboard unit has been built for functional testing in laboratory and thermal vacuum environments. Experimental results show excellent performance of the thermal system and correlate very well with theoretical predictions.

Ku, Jentung↗

Operation Data from the UW Natural Circulation FLiBe Flow Loop

Operating measurements from three multi-week test campaigns of the natural circulation FLiBe loop. This system is investigating thermal hydraulic behavior of the molten salt BeF_2 -LiF (33 - 67 mol %). The system behaves in a stable fashion, but shows unusual local transients, such as flow break-down in the riser and thermal jumps at the cooler exit. Heat transfer shows promising trends that FLiBe will behave as a normal heat transfer fluid, as long as salt purity can be maintained. The most recent test shows heat transfer degradation that is likely a result of oxides and impurities. The data archive contains as-built dimensions, Matlab analysis codes, and the raw data files.

42 ENGINEERING↗

GEO2D - Two-Dimensional Computer Model of a Ground Source Heat Pump System

This file contains a zipped file that contains many files required to run GEO2D. GEO2D is a computer code for simulating ground source heat pump (GSHP) systems in two-dimensions. GEO2D performs a detailed finite difference simulation of the heat transfer occurring within the working fluid, the tube wall, the grout, and the ground. Both horizontal and vertical wells can be simulated with this program, but it should be noted that the vertical wall is modeled as a single tube. This program also models the heat pump in conjunction with the heat transfer occurring. GEO2D simulates the heat pump and ground loop as a system. Many results are produced by GEO2D as a function of time and position, such as heat transfer rates, temperatures and heat pump performance. On top of this information from an economic comparison between the geothermal system simulated and a comparable air heat pump systems or a comparable gas, oil or propane heating systems with a vapor compression air conditioner. The version of GEO2D in the attached file has been coupled to the DOE heating and cooling load software called ENERGYPLUS. This is a great convenience for the user because heating and cooling loads are an input to GEO2D. GEO2D is a user friendly program that uses a graphical user interface for inputs and outputs. These make entering data simple and they produce many plotted results that are easy to understand. In order to run GEO2D access to MATLAB is required. If this program is not available on your computer you can download the program MCRInstaller.exe, the 64 bit version, from the MATLAB website or from the Geothermal Data Repository. This is a free download which will enable you to run GEO2D.

15 GEOTHERMAL ENERGY↗

Mutual Influence of Capillary Pumps in Heat-Pipe Systems with Different Evaporator Loads

Thermal management systems that are not hermetically sealed have been developed for use in spacecraft; in such systems, scientific equipment and instruments operate in open space. Accordingly, new methods of thermal regulation have been developed: axial and loop heat pipes; and honeycomb thermal panels with embedded axial heat pipes. Heat transfer in heating systems with heat pipes is based on evaporation and condensation in a two-phase loop. The working fluid moves under the action mainly of capillary forces that appear in capillary channels or honeycomb structures for axial heat pipes and in the porous heated medium (capillary pump) of the loop heat pipes.

42 ENGINEERING↗

Membrane-Based Gas Traps for Ammonia, Freon-21, and Water Systems to Simplify Ground Processing

Gas traps are critical for the smooth operation of coolant loops because gas bubbles can cause loss of centrifugal pump prime, interference with sensor readings, inhibition of heat transfer, and blockage of passages to remote systems. Coolant loops are ubiquitous in space flight hardware, and thus there is a great need for this technology. Conventional gas traps will not function in micro-gravity due to the absence of buoyancy forces. Therefore, clever designs that make use of adhesion and momentum are required for adequate separation, preferable in a single pass. The gas traps currently used in water coolant loops on the International Space Station are composed of membrane tube sets in a shell. Each tube set is composed of a hydrophilic membrane (used for water transport and capture of bubbles) and a hydrophobic membrane (used for venting of air bubbles). For the hydrophilic membrane, there are two critical pressures, the pressure drop and the bubble pressure. The pressure drop is the decrease in system pressure across the gas trap. The bubble pressure is the pressure required for air bubbles to pass across the water filled membrane. A significant difference between these pressures is needed to ensure complete capture of air bubbles in a single pass. Bubbles trapped by the device adsorb on the hydrophobic membrane in the interior of the hydrophilic membrane tube. After adsorption, the air is vented due to a pressure drop of approximately 1 atmosphere across the membrane. For water systems, the air is vented to the ambient (cabin). Because water vapor can also transport across the hydrophobic membrane, it is critical that a minimum surface area is used to avoid excessive water loss (would like to have a closed loop for the coolant). The currently used gas traps only provide a difference in pressure drop and bubble pressure of 3-4 psid. This makes the gas traps susceptible to failure at high bubble loading and if gas venting is impaired. One mechanism for the latter is when particles adhere to the hydrophobic membrane, promoting formation of a water layer about it that can blind the membrane for gas transport (Figure 1). This mechanism is the most probable cause for observed failures with the existing design. The objective of this project was to devise a strategy for choosing new membrane materials (database development and procedure), redesign of the gas trap to mitigate blinding effects, and to develop a design that can be used in ammonia and Freon-21 coolant loops.

Ritchie, Stephen M. C.↗

Ventilation Heat Exchanger / Flow Meter for xPLSS

The flow meter / heat exchanger (FMHX) in the ventilation loop of the exploration EMU cools the ventilation gas and measures the ventilation flow rate. The heat exchanger transfers heat from the ventilation gas to the thermal control loop via a miniature shell-and-tube heat exchanger. The flow meters calculate the flow rate of gas through the ventilation loop based on the pressure drop across the heat exchanger core. Creare has delivered four design validation test (DVT) heat exchangers and five DVT flow meters to NASA JSC to support development of the exploration portable life support system (xPLSS). This paper describes the design and performance of the DVT units.The heat exchangers are designed to cool the ventilation gas to a specified temperature with low pressure losses under the most challenging operating conditions. The measured performance of the DVT heat exchangers agrees well with design models and meets all performance requirements. The flow meters use a MEMS thermal flow sensor to produce a signal that is proportional to a small bypass flow around the heat exchanger core. They are designed to achieve high measurement accuracy across the full range of xPLSS operating conditions. We calibrated the flow meters in a special-purpose flow facility that simulates operation in the xPLSS ventilation loop. Calibration testing shows that DVT flow meters produce digital output for vent loop mass flow that meets NASA’s accuracy requirements across the range of xPLSS operating conditions. This paper reviews the design of the heat exchangers and flow meters and presents data from the final flow meter calibration testing, heat exchanger performance validation, and initial ground testing in NASA’s xPLSS.

spacesuit↗

Ventilation Heat Exchanger / Flow Meter for xPLSS

The flow meter / heat exchanger (FMHX) in the ventilation loop of the exploration EMU cools the ventilation gas and measures the ventilation flow rate. The heat exchanger transfers heat from the ventilation gas to the thermal control loop via a miniature shell-and-tube heat exchanger. The flow meters calculate the flow rate of gas through the ventilation loop based on the pressure drop across the heat exchanger core. Creare has delivered four design validation test (DVT) heat exchangers and five DVT flow meters to NASA JSC to support development of the exploration portable life support system (xPLSS). This paper describes the design and performance of the DVT units.The heat exchangers are designed to cool the ventilation gas to a specified temperature with low pressure losses under the most challenging operating conditions. The measured performance of the DVT heat exchangers agrees well with design models and meets all performance requirements. The flow meters use a MEMS thermal flow sensor to produce a signal that is proportional to a small bypass flow around the heat exchanger core. They are designed to achieve high measurement accuracy across the full range of xPLSS operating conditions. We calibrated the flow meters in a special-purpose flow facility that simulates operation in the xPLSS ventilation loop. Calibration testing shows that DVT flow meters produce digital output for vent loop mass flow that meets NASA’s accuracy requirements across the range of xPLSS operating conditions. This paper reviews the design of the heat exchangers and flow meters and presents data from the final flow meter calibration testing, heat exchanger performance validation, and initial ground testing in NASA’s xPLSS.

spacesuit↗

Code Validation of SAM Using Forced and Natural Circulation Data from NACIE-UP Benchmark

Heavy liquid metals (HLMs) are promising candidates as coolants of Generation IV fast reactors due to their thermophysical properties. In the last decade, experimental work has been proposed as part of research and development efforts to develop such systems. In this context, researchers from the Brasimone Research Center have conducted many experiments using the Natural Circulation Experiment Upgrade (NACIE-UP) facility to study the thermofluid dynamic behavior of HLMs in rod bundle configurations with or without wire wrappers. This facility consists of a rectangular loop operated with lead-bismuth eutectic. Sensors across the loop monitor relevant parameters, i.e. temperatures, heat transfer, and flow conditions. Here, in the present work, we carefully select published data from NACIE-UP to validate the System Analysis Module (SAM), a modern system analysis code developed at Argonne National Laboratory. We developed one SAM model using specifications of the facility geometry and materials existing in relevant papers and reports. On top of that, these references provided the boundary conditions for simulating natural circulation and forced convection experiments in either steady or transient conditions. The SAM model simulates five test cases with diverse operating conditions. Ultimately, the code is proven to predict temperatures and mass flow rates that closely match the experiments. The discrepancies between numerical predictions and diverse transients are limited to a few degrees Celsius, showcasing that SAM is well suited for analyzing nuclear systems relying on HLM coolants.

advanced reactors↗

Evaluation of advanced component concepts for an integrated environmental control/life support, resistojet control system

Flow restricting devices were studied for their suitability as liquid water propellant flow limiters for the biowaste resistojet. Flow limiting during the start-up transient is required to prevent thrustor instabilities and icing which could result in heater failure in the electrical resistance heated thrustor (resistojet). The study was directed toward simple devices which would function passively (i.e., without power except from the propellant flow itself), and would offer high reliability and simplicity. In addition to the flow limiting devices, a thermal pumping system was studied to determine whether CO2, desorbed from molecular sieves could be pumped thermally in a space station application. The thermal pump is considered a possible replacement for mechanical pumps. It involves a cyclic, constant volume cryopumping system which employs space radiators to achieve the cryotemperatures. The frozen CO2 would be vaporized periodically, using a waste heat loop, to attain sufficient pressure to transfer a large portion of the trapped CO2 to storage tanks.

Halbach, C. R.↗

Review of convectively cooled structures for hypersonic flight

Resurgent interest in development of Aerospace Plane and Orient Express type vehicles promises to stretch structural technology for hypersonic flight vehicles to the uppermost limits. Significant portions of the structure may require active cooling of some type to survive hostile environments. Despite a lack of recent research activity for cooled structures, a significant body of unclassified knowledge exists concerning such structures. Contractual and in-house research conducted mainly by NASA's Langley Research Center during the 60's and 70's on vehicles very similar to the proposed Orient Express has provided a substantial data base for convectively cooled hypersonic flight structures. Specifically, results are presented for regeneratively cooled structural concepts which have a relatively high heat flux capability and use the hydrogen fuel directly as a coolant; and for structural concepts which use a secondary coolant loop to absorb incident heating and then transfer the absorbed heat to the liquid hydrogen fuel as it flows to the engines. Results are presented to indicate application regions in terms of heat flux capability for various concepts and benefits for each concept. Experience gained and costs are discussed in terms of heat flux capability for various concepts and benefits for each concept. Additionally, experience gained and cost involved with design, fabrication, and testing of full-scale convectively cooled structures are discussed.

Shore, Charles P.↗

Pressurized-Flat-Interface Heat Exchanger

High thermal conductance obtained without leakage between loops. Heat-exchanger interface enables efficient transfer of heat between two working fluids without allowing fluids to intermingle. Interface thin, flat, and easy to integrate into thermal system. Possible application in chemical or pharmaceutical manufacturing when even trace contamination of process stream with water or other coolant ruins product. Reduces costs when highly corrosive fluids must be cooled or heated.

Voss, F. E.↗

Nonazeotropic Heat Pump

Heat pump collects heat from water circulating in heat-rejection loop, raises temperature of collected heat, and transfers collected heat to water in separate pipe. Includes sealed motor/compressor with cooling coils, evaporator, and condenser, all mounted in outer housing. Gradients of temperature in evaporator and condenser increase heat-transfer efficiency of vapor-compression cycle. Intended to recover relatively-low-temperature waste heat and use it to make hot water.

Ealker, David H.↗

Tests characterizing bioprocessor hardware for analytical modeling

The tests outlined in this paper were used to characterize the hardware components of the Salad Machine, a small NASA-developed bioprocessor. The data from these tests are presented, and the methods by which this data can be integrated into system mathematical models are briefly discussed. The subsystems and physical processes discussed include the lighting system, the air loop (condensing heat exchanger and the blower), heat transfer to the surroundings, and leakage. Through this effort it was learned that in the development of a test protocol, care should be taken to order the tests such that environmental parameters, particularly humidity, require as few large adjustments as possible. Sensor calibration and installation take a substantial amount of time, which should be built into the test schedule. Two properties were particularly hard to quantify: the air flow rate and the energy from the lighting system entering into the growth volume. Flow rate can be measured using the appropriate device for the system configuration and airflow. Lighting system radiation level was measured using three methods. The results of these methods varied substantially, putting off conclusive quantification of this value.

Gustavino, S.↗

Development and Transient Analysis of a Helical-coil Steam Generator for High Temperature Reactors

A high temperature gas-cooled reactor (HTGR) is under development by the Next Generation Nuclear Plant (NGNP) Project at the Idaho National Laboratory (INL). Its design emphasizes electrical power production which may potentially be coupled with process heat for hydrogen production and other industrial applications. NGNP is considering a helical-coil steam generator for the primary heat transport loop heat exchanger based on its increased heat transfer and compactness when compared to other steam generators. The safety and reliability of the helical-coil steam generator is currently under evaluation as part of the development of NGNP. Transients, such as loss of coolant accidents (LOCA), are of interest in evaluating the safety of steam generators. In this study, a complete steam generator inlet pipe break (double ended pipe break) LOCA was simulated by an exponential loss of primary side pressure. For this analysis, a model of the helical-coil steam generator was developed using RELAP5-3D, an INL inhouse systems analysis code. The steam generator model behaved normally during the transient simulating the complete steam generator inlet pipe break LOCA. Further analysis is required to comprehensively evaluate the safety and reliability of the helical-coil steam generator design in the NGNP setting.

08 HYDROGEN↗

The Effect of Nanofluids on the Heat-Transfer Capacity of Miniature Thermosyphons for Electronics Cooling

Stable nanofluids based on DG-100 grade carbon black and carbon nanotubes have been prepared, and their influence on the maximum heat-transfer capacity and thermal resistance of closed-loop two-phase thermosyphons (TPTs) intended for electronics cooling have been studied. A more than twofold increase in the critical heat flux of these TPTs as compared to those filled with water has been obtained along with a sharp decrease in their thermal resistance. It is suggested that this effect is not only due to the high thermal conductivity of the proposed nanofluids, but is also related to the formation of a specific porous structure hindering the appearance of a vapor film and enhancing the boiling process.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Fuel Cell Thermal Management Through Conductive Cooling Plates

An analysis was performed to evaluate the concept of utilizing conductive cooling plates to remove heat from a fuel cell stack, as opposed to a conventional internal cooling loop. The potential advantages of this type of cooling system are reduced stack complexity and weight and increased reliability through the reduction of the number of internal fluid seals. The conductive cooling plates would extract heat from the stack transferring it to an external coolant loop. The analysis was performed to determine the required thickness of these plates. The analysis was based on an energy balance between the thermal energy produced within the stack and the heat removal from the cooling plates. To accomplish the energy balance, the heat flow into and along the plates to the cooling fluid was modeled. Results were generated for various numbers of cells being cooled by a single cooling plate. The results provided cooling plate thickness, mass, and operating temperature of the plates. It was determined that utilizing high-conductivity pyrolitic graphite cooling plates can provide a specific cooling capacity (W/kg) equivalent to or potentially greater than a conventional internal cooling loop system.

Colozza, Anthony J.↗

Selection of an Alternate Biocide for the ISS Internal Thermal Control System Coolant, Phase 2

The ISS (International Space Station) ITCS (Internal Thermal Control System) includes two internal coolant loops that utilize an aqueous based coolant for heat transfer. A silver salt biocide had previously been utilized as an additive in the coolant formulation to control the growth and proliferation of microorganisms within the coolant loops. Ground-based and in-flight testing demonstrated that the silver salt was rapidly depleted, and did not act as an effective long-term biocide. Efforts to select an optimal alternate biocide for the ITCS coolant application have been underway and are now in the final stages. An extensive evaluation of biocides was conducted to down-select to several candidates for test trials and was reported on previously. Criteria for that down-select included: the need for safe, non-intrusive implementation and operation in a functioning system; the ability to control existing planktonic and biofilm residing microorganisms; a negligible impact on system-wetted materials of construction; and a negligible reactivity with existing coolant additives. Candidate testing to provide data for the selection of an optimal alternate biocide is now in the final stages. That testing has included rapid biocide effectiveness screening using Biolog MT2 plates to determine minimum inhibitory concentration (amount that will inhibit visible growth of microorganisms), time kill studies to determine the exposure time required to completely eliminate organism growth, materials compatibility exposure evaluations, coolant compatibility studies, and bench-top simulated coolant testing. This paper reports the current status of the effort to select an alternate biocide for the ISS ITCS coolant. The results of various test results to select the optimal candidate are presented.

Wilson, Mark E.↗